Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Corrosion of rebar in concrete. Part III: Artificial Neural Network analysis of chloride threshold data

Active corrosion of carbon steel in reinforced concrete occurs when the chloride ion concentration exceeds the chloride threshold (CT). CT is affected by many physical and chemical parameters including primary variables (pH, corrosion potential, breakdown potential, and temperature) and secondary variables (cemenet composition, concreete porosity, and water/cement ratio). A Kohonen-self organized map (KSOM) and regression artificial neural network (ANN) coupled methodology was developed to find the missing values of independent variables in the sparse database and for quantitatively evaluating the effects of these variables on CT values that are expressed in %TotalCl/cem (or %FreeCl/cem), and [Cl - ]/[OH - ].

36 MATERIALS SCIENCE↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Boosting Hydrogen Evolution in Neutral Medium by Accelerating Water Dissociation with Ru Clusters Loaded on Mo 2 CTx MXene

Abstract Electrocatalytic hydrogen evolution reaction (HER) in mild neutral medium is a compelling goal for environmentally sustainable energy conversion, but its development is greatly limited by slow kinetics. Platinum group noble metals exhibit ultra‐high HER activities, but their scarcity and performance instability restrict wide application. Herein, taking advantage of excellent catalyst carrier properties of 2D‐layered transition metal carbides (MXenes), highly dispersed of Ru clusters anchored on Mo 2 CT x MXene are demonstrated as a superior HER electrocatalyst, which is prepared by a facile in situ reduction strategy. The as‐prepared Ru/Mo 2 CT x catalyst exhibits a very low overpotential of 73 mV to achieve a current density of −10 mA cm −2 and Tafel slope of 57 mV dec −1 in neutral medium, surpassing performance of most previously reported MXene‐based catalysts. In addition, Ru/Mo 2 CT x catalyst also presents superior stability compared to commercial Pt/C. Experimental results and theoretical calculations indicate that the interaction between Ru clusters modulates the electronic structure of active sites and promotes H 2 O dissociation and hydrogen desorption.

Wu, Yanze↗

Responsive Interfacial Assemblies Based on Charge‐Transfer Interactions

Abstract Charge transfer (CT) interactions have been widely used to construct supramolecular systems, such as functional nanostructures and gels. However, to date, there is no report on the generation of CT complexes at the liquid–liquid interface. Here, by using an electron‐deficient acceptor dissolved in water and an electron‐rich donor dissolved in oil, we present the in situ formation and assembly of CT complex surfactants (CTCSs) at the oil–water interface. With time, CTCSs can assemble into higher‐order nanofilms with exceptional mechanical properties, allowing the stabilization of liquids and offering the possibility to structure liquids into nonequilibrium shapes. Moreover, due to the redox‐responsiveness of the electron‐deficient acceptor, the association and dissociation of CTCSs can be reversibly manipulated in a redox process, leading to the switchable assembly and disassembly of the resultant constructs.

Sun, Shuyi↗

Responsive Interfacial Assemblies Based on Charge‐Transfer Interactions

Abstract Charge transfer (CT) interactions have been widely used to construct supramolecular systems, such as functional nanostructures and gels. However, to date, there is no report on the generation of CT complexes at the liquid–liquid interface. Here, by using an electron‐deficient acceptor dissolved in water and an electron‐rich donor dissolved in oil, we present the in situ formation and assembly of CT complex surfactants (CTCSs) at the oil–water interface. With time, CTCSs can assemble into higher‐order nanofilms with exceptional mechanical properties, allowing the stabilization of liquids and offering the possibility to structure liquids into nonequilibrium shapes. Moreover, due to the redox‐responsiveness of the electron‐deficient acceptor, the association and dissociation of CTCSs can be reversibly manipulated in a redox process, leading to the switchable assembly and disassembly of the resultant constructs.

Sun, Shuyi↗

The Wormholes Within: A Study of 1, 3, 5–Triamino–2, 4, 6–Trinitrobenzene Crystal Morphology by Micro and Nano–Scale X–Ray Computed Tomography and its Effects Upon the Shock Sensitivity of Detonation

We report that we understand heterogeneous-explosive detonation only to the extent that we can first measure the salient chemical and microstructural features. Barring an inordinate amount of trial and error, we can tailor the detonation properties of our HE formulations only to the extent that we understand (at least qualitatively) the same effects. As an insensitive high explosive, 1, 3, 5-triamino-2, 4, 6-trinitrobenzene (TATB) burns more heterogeneously than conventional high explosives, making its detonation properties sensitive to microstructure. The Benziger route can produce various grain morphologies depending on the amount of water used in the amination step. So-called dry-aminated (DA) TATB crystals are riddled with a void structure called wormholes, which are washed out ammonium chloride (NH4Cl) inclusions that form during synthesis. So-called wet-aminated (WA) TATB crystals do not contain NH 4 Cl inclusions but possess a very convoluted external structure. Using both micro and nano-scale CT, we explore three DA-TATB lots that reflect evolutionary processing changes, plus one WA-TATB material. Micro CT imaged crystal collections show the exterior grain structure, revealing its roughness and providing a crude particle size measurement. The DA-TATB lots that test most sensitively in the LANL ECOT corner-turning test are roughest, having the appearance of being “corroded”. Nano-scale CT reveals both internal NH 4 Cl inclusions and void structures. The DA-TATB lots that tested intermediate and high sensitivity in ECOT exhibited similar wormhole structures, which were more extensive than that of the low-sensitivity lot. The least sensitive DA-TATB lot also retained more NH 4 Cl, consistent with reduced connectivity of voids to the surface.

1, 3, 5-triamino-2,4↗

Tomographic X-ray particle tracking velocimetry

We investigate the feasibility of in-laboratory tomographic X-ray particle tracking velocimetry (TXPTV) and consider creeping flows with nearly density matched flow tracers. Specifically, in these proof-of-concept experiments we examined a Poiseuille flow, flow through porous media and a multiphase flow with a Taylor bubble. For a full 360° computed tomography (CT) scan we show that the specially selected 60 micron tracer particles could be imaged in less than 3 seconds with a signal-to-noise ratio between the tracers and the fluid of 2.5, sufficient to achieve proper volumetric segmentation at each time step. In the pipe flow, continuous Lagrangian particle trajectories were obtained, after which all the standard techniques used for PTV or PIV (taken at visible wave lengths) could also be employed for TXPTV data. And, with TXPTV we can examine flows inaccessible with visible wave lengths due to opaque media or numerous refractive interfaces. In the case of opaque porous media we were able to observe material accumulation and pore clogging, and for flow with Taylor bubble we can trace the particles and hence obtain velocities in the liquid film between the wall and bubble, with thickness of liquid film itself also simultaneously obtained from the volumetric reconstruction after segmentation. While improvements in scan speed are anticipated due to continuing improvements in CT system components, we show that for the flows examined even the presently available CT systems could yield quantitative flow data with the primary limitation being the quality of available flow tracers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Out-of-Distribution Detection and Radiological Data Monitoring Using Statistical Process Control

Abstract Machine learning (ML) models often fail with data that deviates from their training distribution. This is a significant concern for ML-enabled devices as data drift may lead to unexpected performance. This work introduces a new framework for out of distribution (OOD) detection and data drift monitoring that combines ML and geometric methods with statistical process control (SPC). We investigated different design choices, including methods for extracting feature representations and drift quantification for OOD detection in individual images and as an approach for input data monitoring. We evaluated the framework for both identifying OOD images and demonstrating the ability to detect shifts in data streams over time. We demonstrated a proof-of-concept via the following tasks: 1) differentiating axial vs. non-axial CT images, 2) differentiating CXR vs. other radiographic imaging modalities, and 3) differentiating adult CXR vs. pediatric CXR. For the identification of individual OOD images, our framework achieved high sensitivity in detecting OOD inputs: 0.980 in CT, 0.984 in CXR, and 0.854 in pediatric CXR. Our framework is also adept at monitoring data streams and identifying the time a drift occurred. In our simulations tracking drift over time, it effectively detected a shift from CXR to non-CXR instantly, a transition from axial to non-axial CT within few days, and a drift from adult to pediatric CXRs within a day—all while maintaining a low false positive rate. Through additional experiments, we demonstrate the framework is modality-agnostic and independent from the underlying model structure, making it highly customizable for specific applications and broadly applicable across different imaging modalities and deployed ML models.

Zamzmi, Ghada↗

Application of unsupervised deep learning to image segmentation and in-situ contact angle measurements in a CO 2 -water-rock system

Rock surface wettability is a critical property that regulates multiphase flows in porous media, which can be quantified using the surface contact angle (CA). X-ray micro-computed tomography (μCT) provides an effective approach to in-situ measurements of surface CAs. However, the CA measurement accuracy depends significantly on the quality of CT image segmentation, which is the clustering of CT pixels into separate phases. Inspired by this, we developed a deep learning (DL)-based CA measurement workflow. Motivated by the recent tremendous progress in unsupervised learning techniques and aiming to avoid expensive manual data annotations, an unsupervised DL pipeline for CT image segmentation was proposed and implemented, which includes unsupervised model training and post-processing. The unsupervised model training was driven by a novel loss function constrained with feature similarity and spatial continuity and implemented by iterative forward and backward paths; the former clustered the pixel-wise feature vectors extracted by convolution neural networks, whereas the latter updated the parameters using gradient descent. An over-segmentation strategy was adopted for model training. The post-processing steps based on agglomerative hierarchical clustering (AHC) were implemented to further merge the over-segmented model output to the desired cluster number, which is intended to improve the efficiency of image segmentation. The developed unsupervised DL pipeline was compared with other commonly-used image segmentation methods using pixel-wise and physics-based evaluation metrics on a synthetic raw-image dataset, which had a known ground truth. The unsupervised DL pipeline showed the best performance. Next, the segmented images were input to an automatic CA measurement tool, and the results were validated by comparisons with manual measurements. The CA values from the manual and automatic measurements showed similar distributions and statistical properties. The automatic measurement demonstrated a wider spectrum because of the much larger number of measurement data points. The primary novelty of the unsupervised DL pipeline developed in this study lies in the novel loss function and the over-segmentation strategy associated with AHC post-processing. Finally, the workflow has been proven an efficient tool for pore-scale wettability characterization, which has a wide range of applications in fundamental studies of multiphase flows in natural porous media, which have critical implications to geological carbon sequestration, hydrocarbon energy recovery, and contaminant transport in groundwater.

42 ENGINEERING↗

Engineering a photoenzyme to use red light

Photoenzymatic reactions involving flavin-dependent “ene”-reductases (EREDs) rely on protein-templated charge transfer (CT) complexes between the cofactor and substrate for radical initiation. These complexes typically absorb in the blue region of the electromagnetic spectrum. Here, we engineered an ERED to form CT complexes that absorb red light. Mechanistic studies indicate that red-light activity is due to the growth of a red-absorbing shoulder off the previously identified cyan absorption feature. Molecular dynamics simulations, docking, and excited-state calculations suggest that the cyan feature involves a π→π* transition on flavin, whereas the red-light absorption is a π→π* transition between flavin and the substrate. Furthermore, differences in the electronic transition are due to changes in the substrate-binding conformation and allosteric tuning of the electronic structure of the cofactor-substrate complex. Microenvironment tuning of the CT complex for red-light activity is observed with other engineered photoenzymatic reactions, highlighting this effect’s generality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-scale imaging of high-pressure hydrogen induced damage in EPDM rubber using X-ray microcomputed tomography, helium-ion microscopy and transmission electron microscopy

Ethylene propylene diene (EPDM) rubber has gained increasing interest for use in hydrogen infrastructure due to its excellent sealing performance and low temperature properties. However, severe structural damage has been observed in EPDM O-rings after exposure to high-pressure hydrogen. The origination and propagation mechanisms of this damage are poorly understood. Here, to address this knowledge gap, multi-scale imaging leveraging X-ray micro-computed tomography (micro-CT), helium ion microscopy (HeIM), and transmission electron microscopy (TEM) were used in this work to study a series of sulfur-cured ethylene propylene diene (EPDM) rubber materials with varying additives that were exposed to different hydrogen environments. Micro-CT captured the substantial structural damage due to hydrogen exposure; it revealed an association between zinc oxide (ZnO) particles and damage initiation. Further studies by TEM and scanning TEM with energy dispersive X-ray spectroscopy (EDS) were focused on these particles at the micro-to nano-scale range. TEM indicated that hydrogen causes void formation at the interface between ZnO and the rubber matrix. HeIM enabled imaging of surface morphology of the material at high resolution pre- and post-hydrogen exposure while providing information on chemical composition and that cannot be captured by either micro-CT or TEM.

08 HYDROGEN↗

Comparison of three measurement modalities for 3D characterization of manufactured features and process-induced porosity in titanium alloy additively manufactured parts

Nondestructive characterization of internal features and defects within complex components is vital for many industrial applications, particularly with the advent of additive manufacturing (AM) technologies. However, community understanding of the limitations of nondestructive methods such as X-ray Computed Tomography (CT) can be limited in certain industrial sectors as these may be emergent applications. In this paper, we investigate the limits of X-ray CT measurements and compare extracted data with mechanical polishing serial sectioning (MPSS) and confocal laser scanning microscopy (CLSM). The test object is an additively manufactured titanium alloy disk that contains both process-induced porosity and machined features, including focused ion beam milled features designed to probe the resolution limits of X-ray CT. Results show that each of these characterization techniques has advantages and disadvantages. We compare data acquisition times, spatial resolution, geometric measurement accuracy and defect visualization fidelity across these modalities to establish a practical framework.

Additive manufacturing↗

Diabatization with Electrostatic Embedding for Studying Photophysics in Organic Molecular Crystals

Highly emissive organic molecular crystals find applications in several areas, such as organic electronics, solar cells, and sensors. Understanding the excited-state mechanisms underlying these applications is essential for optimizing and controlling them effectively. Exciton models coupled with nonadiabatic dynamics, particularly quantum dynamics, provide crucial insights into photochemical and photophysical processes in molecular crystals. Nevertheless, there remains a lack of general tools and automated workflows to facilitate such simulations. In this paper, we present a computational strategy to investigate the photoactivated dynamics of organic molecular crystals, bridging methodologies traditionally used for molecular systems and materials science, with a particular focus on the interplay between local excitations and charge transfer (CT) processes. We have implemented an interface between the fromage and Overdia programs, enabling the construction of vibronic Hamiltonians for molecular crystals within an excited-state ONIOM(QM:QM′) framework, incorporating long-range electrostatics through a RESP-based Ewald summation. Fragment-based diabatization provides a route to quantum dynamics simulations in weak-to-intermediate coupling regimes. The method was applied to the photophysics of dibenzo[g,p]chrysene (DBC) crystals using time-dependent DFT. The fromage/ Overdia interface was employed to compute the couplings of local excitations and CT states for 18 unique DBC dimers in the crystal and to quantify the influence of electrostatic embedding, which was found to be modest (10−20%). Simulations on π-stacked dimers reproduced the small red shift observed experimentally from solution to crystal, attributed to electronic interactions among fixed monomers rather than crystal electrostatics. Quantum dynamics simulations revealed ultrafast population transfer from bright local excitations to CT states. This approach establishes a robust framework linking molecular and solid-state excited-state dynamics, with potential applications for studying excitations, defects, and impurities in molecular crystals.

Crystals↗

Photoinduced Charge Transfer and Vibronic Coherence in CdSe Quantum Dots with Methyl Viologen Acceptors

We show herein that photoinduced charge transfer from CdSe quantum dots (QDs) to surface-bound methyl viologen (MV 2+ ) acceptors is mediated by a vibronically coherent, nonadiabatic mechanism. Broadband multidimensional electronic spectra and an analysis of coherences show that a mixed QD–MV charge-transfer (CT) state is populated on the <50 fs time scale after optical preparation of the X3 (1P 3/2 –1P e ) state, well prior to the appearance of the one-electron photoreduced ground state (MV +• ). A partial redistribution of charge from the core of the QD to the acceptor is revealed by excited-state coherences of an out-of-plane vibrational mode local to MV 2+ and of a low-frequency mode mixing a MV 2+ mode with the longitudinal optical (LO) phonon of the QD core. The ultrafast damping of these coherences indicates that excited-state wavepackets travel from the optically prepared, Franck–Condon structure through a conical intersection to reach the CT state. These results suggest that vibronically coherent processes generating CT intermediates can be exploited to improve the efficiency of QD-based solar cells and photocatalysts.

Cadmium selenide↗

Ultrafast Interlayer Charge Transfer between Bilayer PtSe 2 and Monolayer WS 2

Interlayer charge transfer (CT) between PtSe 2 and WS 2 is studied experimentally. Layer-selective pump–probe and photoluminescence quenching measurements reveal ultrafast interlayer CT in the heterostructure formed by bilayer PtSe 2 and monolayer WS 2 , confirming its type-II band alignment. The CT facilitates the formation of the interlayer excitons with a lifetime of several hundred ps to 1 ns, a diffusion coefficient of 0.9 cm 2 s –1 , and a diffusion length reaching 200 nm. Furthermore, these results demonstrate the integration of PtSe 2 with other materials in van der Waals heterostructures with novel charge-transfer properties and help develop fundamental understanding on the performance of various optoelectronic devices based on heterostructures involving PtSe 2 .

36 MATERIALS SCIENCE↗