Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CRYOGENIC FLUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Tank Pressure Control Experiment on the Space Shuttle

The tank pressure control experiment is a demonstration of NASA intent to develop new technology for low-gravity management of the cryogenic fluids that will be required for future space systems. The experiment will use freon as the test fluid to measure the effects of jet-induced fluid mixing on storage tank pressure and will produce data on low-gravity mixing processes critical to the design of on-orbit cryogenic storage and resupply systems. Basic data on fluid motion and thermodynamics in low gravity is limited, but such data is critical to the development of space transfer vehicles and spacecraft resupply facilities. An in-space experiment is needed to obtain reliable data on fluid mixing and pressure control because none of the available microgravity test facilities provide a low enough gravity level for a sufficient duration to duplicate in-space flow patterns and thermal processes. Normal gravity tests do not represent the fluid behavior properly; drop-tower tests are limited in length of time available; aircraft low-gravity tests cannot provide the steady near-zero gravity level and long duration needed to study the subtle processes expected in space.

Source record↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Pumping and Depressurizing of Insulation Materials

The Fluids Testing and Technology Branch is a group that researches and tests efficient ways to use various Cryogenic Fluids, such as Liquid Nitrogen or Liquid Helium, in ground and space systems. Their main goal is to develop new technologies involving Cryogenic temperatures as well as making sure the existing technologies are understood. During my time here a lot of insulation testing has been done which is where insulation systems are tested for cryogenic systems that are in space for long durations.

Porter, Amber↗

Quick attach and release fluid coupling assembly is self-aligning, self-sealing

Fluid coupling assembly that is self-aligning, self-sealing and contains a bellow ball and socket coupling for quick attach and release is highly reliable and can handle cryogenic fluids where icing is encountered. The fluid coupling assembly is used in many fluid systems but is particularly applicable to cryogenic systems.

Herold, C. P.↗

Updated, expanded, fluid properties handbook

Revised handbook presents quantitative data, in the form of graphs and charts, pertaining to thermodynamic properties of specific cryogenic fluids and several metals. References to sources of data are cited.

Gershman, R.↗

Foil bearing performance in liquid nitrogen and liquid oxygen

Space transfer vehicles and other power and propulsion systems require long-life turbopumps. Rolling-element bearings used in current turbopumps do not have sufficient life for these applications. Process fluid foil bearings have established long life, with exceptional reliability, over a wide range of temperatures and fluids in many high-speed turbomachinery applications. However, actual data on bearing performance in cryogenic fluids has been minimal. The National Aeronautics and Space Administration (NASA) and AlliedSignal Aerospace Systems and Equipment (ASE) have attempted to characterize the leaf-type compliant foil bearing in oxygen and nitrogen. The work performed under a joint internal research and development program between Marshall Space Flight Center (MSFC) and ASE demonstrated that the foil bearing has load capacities of at least 266 psi in liquid oxygen and 352 psi in liquid nitrogen. In addition, the bearing demonstrated a direct damping coefficient of 40 to 50 lb-sec/in. with a damping ratio of .7 to 1.4 in. liquid nitrogen using a bearing sized for upper-stage turbopumps. With the results from this testing and the years of successful use in air cycle machines and other applications, leaf-type compliant foil bearings are ready for testing in liquid oxygen turbopumps.

Genge, Gary G.↗

Liquefied Natural Gas Transfer

Chicago Bridge & Iron Company's tanks and associated piping are parts of system for transferring liquefied natural gas from ship to shore and storing it. LNG is a "cryogenic" fluid meaning that it must be contained and transferred at very low temperatures, about 260 degrees below Fahrenheit. Before the LNG can be pumped from the ship to the storage tanks, the two foot diameter transfer pipes must be cooled in order to avoid difficulties associated with sharp differences of temperature between the supercold fluid and relatively warm pipes. Cooldown is accomplished by sending small steady flow of the cryogenic substance through the pipeline; the rate of flow must be precisely controlled or the transfer line will be subjected to undesirable thermal stress.

Source record↗

A Review of Superconducting Electric Machines with On-Board Cryocoolers

This paper reviews the evolution and emerging direction of superconducting electric machines that employ onboard cryocoolers integrated directly into the rotor, eliminating the need for cryogenic fluid coupling and, in some cases, rotary seals. Traditional low-temperature superconducting (LTS) machines relied on external cryogenic systems and liquid helium transfer couplers, which introduced excessive complexity, poor reliability, and significant parasitic energy losses. The advent of high-temperature superconductors (HTS) has enabled compact, closed-cycle cryocoolers that support self-contained, fluid-free refrigeration architectures suitable for rotating applications. This paper examines the key technological challenges associated with on-board cryocooler integration and reviews three representative efforts by KAIST, NASA, and Hinetics, each illustrating distinct strategies and milestones toward practical implementation. KAIST demonstrated early proof-of-concept for rotating machines with on-board cryocoolers, NASA developed a shaft-integrated Stirling-type pulse tube cryocooler for a 1.4 MW hybrid-electric motor, and Hinetics achieved full-scale validation of a self-contained HTS rotor incorporating a commercial Stirling cryocooler and spoke-suspension torque tube. Collectively, these achievements confirm the technical feasibility of on-board cryogenic refrigeration and highlight steady progress toward compact and efficient superconducting rotating systems across various applications. Embedding cryocoolers directly within the rotor enables practical, efficient, and commercially viable superconducting propulsion technologies.

Cryogenics↗

Connector seals fluid lines at cryogenic temperatures and high vacuums

A connector that will serve as a seal for fluids at cryogenic temperatures and in high vacuums was constructed by installing a metal disk between two sets of mating serrations to form two sealing surfaces. Compression on both sealing surfaces is ensured by spring action of the disk.

Kitts, W. T.↗

Effect of ice contamination of liquid-nitrogen drops in film boiling

Previously reported vaporization time data of liquid nitrogen drops in film boiling on a flat plate are about 30 percent shorter than predicted from standard laminar film boiling theory. This theory, however, had been found to successfully correlate the data for conventional fluids such as water, ethanol, benzene, or carbon tetrachloride. Experimental evidence that some of the discrepancy for cryogenic fluids results from ice contamination due to condensation is presented. The data indicate a fairly linear decrease in droplet evaporation time with the diameter of the ice crystal residue. After correcting the raw data for ice contamination along with convection, a comparison of theory with experiment shows good agreement.

Schoessow, G. J.↗

Liquid Nitrogen Testing of an Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

RCS↗

Liquid Nitrogen Testing of An Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

RCS↗

Vent System Analysis for the Cryogenic Propellant Storage Transfer Ground Test Article

To test and validate key capabilities and technologies required for future exploration elements such as large cryogenic propulsion stages and propellant depots, NASA is leading the efforts to develop and design the Cryogenic Propellant Storage and Transfer (CPST) Cryogenic Fluid Management (CFM) payload. The primary objectives of CPST payload are to demonstrate: 1) in-space storage of cryogenic propellants for long duration applications; and 2) in-space transfer of cryogenic propellants. The Ground Test Article (GTA) is a technology development version of the CPST payload. The GTA consists of flight-sized and flight-like storage and transfer tanks, liquid acquisition devices, transfer, and pressurization systems with all of the CPST functionality. The GTA is designed to perform integrated passive and active thermal storage and transfer performance testing with liquid hydrogen (LH2) in a vacuum environment. The GTA storage tank is designed to store liquid hydrogen and the transfer tank is designed to be 5% of the storage tank volume. The LH2 transfer subsystem is designed to transfer propellant from one tank to the other utilizing pressure or a pump. The LH2 vent subsystem is designed to prevent over-pressurization of the storage and transfer tanks. An in-house general-purpose computer program was utilized to model and simulate the vent subsystem operation. The modeling, analysis, and the results will be presented in the final paper.

Hedayat, A↗

Effect of ice contamination on liquid-nitrogen drops in film boiling

Previously reported vaporization time data of liquid nitrogen drops in film boiling on a flat plate are about 30 percent shorter than predicted from standard laminar film boiling theory. This theory, however, had been found to successfully correlate the data for conventional fluids such as water, ethanol, benzene, or carbon tetrachloride. This paper presents experimental evidence that some of the discrepancy for cryogenic fluids results from ice contamination due to condensation. The data indicate a fairly linear decrease in droplet evaporation time with the diameter of the ice crystal residue. After correcting the raw data for ice contamination along with convection, a comparison of theory with experiment shows good agreement.

Schoessow, G. J.↗

Solar Thermal Upper Stage Liquid Hydrogen Pressure Control Testing

High-energy cryogenic propellant is an essential element in future space exploration programs. Therefore, NASA and its industrial partners are committed to an advanced development/technology program that will broaden the experience base for the entire cryogenic fluid management community. Furthermore, the high cost of microgravity experiments has motivated NASA to establish government/aerospace industry teams to aggressively explore combinations of ground testing and analytical modeling to the greatest extent possible, thereby benefitting both industry and government entities. One such team consisting of ManTech SRS, Inc., Edwards Air Force Base, and Marshall Space Flight Center (MSFC) was formed to pursue a technology project designed to demonstrate technology readiness for an SRS liquid hydrogen (LH2) in-space propellant management concept. The subject testing was cooperatively performed June 21-30, 2000, through a partially reimbursable Space Act Agreement between SRS, MSFC, and the Air Force Research Laboratory. The joint statement of work used to guide the technical activity is presented in appendix A. The key elements of the SRS concept consisted of an LH2 storage and supply system that used all of the vented H2 for solar engine thrusting, accommodated pressure control without a thermodynamic vent system (TVS), and minimized or eliminated the need for a capillary liquid acquisition device (LAD). The strategy was to balance the LH2 storage tank pressure control requirements with the engine thrusting requirements to selectively provide either liquid or vapor H2 at a controlled rate to a solar thermal engine in the low-gravity environment of space operations. The overall test objective was to verify that the proposed concept could enable simultaneous control of LH2 tank pressure and feed system flow to the thruster without necessitating a TVS and a capillary LAD. The primary program objectives were designed to demonstrate technology readiness of the SRS concept at a system level as a first step toward actual flight vehicle demonstrations. More specific objectives included testing the pressure and feed control system concept hardware for functionality, operability, and performance. Valuable LH2 thermodynamic and fluid dynamics data were obtained for application to both the SRS concept and to future missions requiring space-based cryogen propellant management.

Moore, J. D.↗

Progress on the Reduced Gravity Cryogenic Transfer (RGCT) Project

Reduced gravity transfer of cryogenic propellants is crucial to being able to perform planned extended-duration space exploration missions. However, the transfer of cryogenic propellants under reduced gravity conditions has never been demonstrated in a mass-efficient fashion. Efficient cryogenic fluid transfer methods will reduce the transfer time or amount of propellant consumed for chilldown of transfer lines and tanks and ensure successful engine restart or fill of a customer receiver tank. The purpose of the Reduced Gravity Cryogenic Transfer (RGCT) project is to enhance line chilldown, tank chilldown, and tank fill/transfer in a reduced gravity environment through (1) ground and reduced gravity cryogenic testing and (2) numerical model development and validation, which includes empirical, lumped capacitance, and computational fluid dynamics modeling. Technologies developed, data gathered, and models developed and validated under RGCT have played a critical role in enabling longer duration in-space missions. This presentation will provide a description of the ongoing cryogenic propellant transfer ground and reduced gravity testing, numerical modeling, and technology development to-date.

Boiling↗