Characterization of Encapsulated Corrosion Inhibitors for Environmentally Friendly Smart Coatings

The NASA Kennedy Space Center's Corrosion Technology Lab at the Kennedy Space Center in Florida, U.S.A. has been developing multifunctional smart coatings based on the microencapsulation of environmentally friendly corrosion indicators, inhibitors and self-healing agents. This allows the incorporation of autonomous corrosion control functionalities, such as corrosion detection and inhibition as well as the self-healing of mechanical damage, into coatings. This paper presents technical details on the characterization of inhibitor-containing particles and their corrosion inhibitive effects using electrochemical and mass loss methods. Three organic environmentally friendly corrosion inhibitors were encapsulated in organic microparticles that are compatible with desired coatings. The release of the inhibitors from the microparticles in basic solution was studied. Fast release, for immediate corrosion protection, as well as long-term release for continued protection, was observed. The inhibition efficacy of the inhibitors, incorporated directly and in microparticles, on carbon steel was evaluated. Polarization curves and mass loss measurements showed that, in the case of 2MBT, its corrosion inhibition effectiveness was greater when it was delivered from microparticles.

Corrosion↗

Release Properties and Electrochemical Characterization of Encapsulated Corrosion Inhibitors for Environmentally Friendly Smart Coatings

The NASA Kennedy Space Center's Corrosion Technology Lab at the Kennedy Space Center in Florida, U.S.A. has been developing multifunctional smart coatings based on the microencapsulation of environmentally friendly corrosion indicators, inhibitors and self-healing agents. This allows for the incorporation of autonomous corrosion control functionalities, such as corrosion detection and inhibition as well as the self-healing of mechanical damage, into coatings. This paper presents technical details on the characterization of inhibitor-containing particles and their corrosion inhibitive effects using electrochemical and mass loss methods. Three organic environmentally friendly corrosion inhibitors were encapsulated in organic microparticles that are compatible with desired coatings. The total inhibitor content and the release of one of the inhibitors from the microparticles in basic solution was measured. Particles with inhibitor contents of up 60 wt% were synthesized. Fast release, for immediate corrosion protection, as well as long-term release for continued protection, was observed. The inhibition efficacy of the inhibitors, both as the pure materials and in microparticles, on carbon steel was evaluated. Polarization curves and mass loss measurements showed that, in the case of 2MBT, its corrosion inhibition effectiveness was greater when it was delivered from microparticles.

Coatings↗

Long-Term Corrosivity at NASA Kennedy Space Center as a Function of Distance and Time from the Atlantic Ocean

Long-term data to record both seasonal and notional bounding values for corrosivity at multiple sites at NASA Kennedy Space Center was needed to make better materials choices for NASA-based ground and spaceflight programs. The data was valuable for two key reasons, 1) to measure corrosion rate and chloride concentration as a function of time and distance from the Atlantic Ocean, and 2) compare the corrosivity at launchpad and site-specific areas to the more accelerated conditions at the KSC Beachside Atmospheric Corrosion Test Site for coating and materials performance prediction. Sites were chosen from 45 meter (150 feet) to 8 kilometers (5 miles) from the Atlantic Ocean and corrosion variables at each site were measured throughout each year from June 2017 to April 2023, except the Beachside site, which includes data from November 2010. The summary includes corrosivity data and coating performance comparisons at select sites, which will be used as the updated NASA corrosivity standard for corrosion control requirements.

NASA↗

Corrosion Inhibition of Cold-rolled Low Carbon Steel with Pulse Fiber Laser Ablation in Water

This study aims at the use of a fiber laser for modifying the surface properties of cold-rolled low carbon steel via a pulse laser ablation technique in water. The effect on the corrosion behavior of the fiber laser-treated metal surface was investigated in NaCl and HCl environments. Electrochemical tests showed significant improvement in the corrosion resistance of the laser-treated sample in NaCl, with an increase in open-circuit potential (OCP) from − 0.65 to − 0.60 V and an inhibition efficiency of 89.22% as obtained from the impedance study. Such improvement was less significant in an acidic environment. Lower corrosion rates of 20.9 mpy and 5.819 × 10{sup 3} mpy were obtained for the laser-treated samples in neutral and acidic electrolytes, respectively, than the corrosion rates obtained for the as-received samples (33.2 mpy and 11.98 × 10{sup 3} mpy). Morphological analysis indicated a passive film built by spherical grains of regular size on the metal surface after laser treatment. The corrosion inhibition effects in NaCl were evident by the nonexistence of the common corrosion products of lepidocrocite and crystalline structures that were seen on as-received samples; only polyhedral crystals with micrograins grown on them were seen covering the laser-treated surface. Therefore, the laser treatment using a fiber laser source improved the corrosion resistance of cold-rolled low carbon steel.

36 MATERIALS SCIENCE↗

Corrosion Performance of Fe-Based Alloys in Simulated Oxy-Fuel Environment

The long-term corrosion of Fe-based alloys in simulated oxy-fuel environment at 1023 K (750 A degrees C) was studied. Detailed results are presented on weight change, scale thickness, internal penetration, microstructural characteristics of the corrosion products, and the cracking of scales for the alloys after exposure at 1023 K (750 A degrees C) for up to 3600 hours. An incubation period during which the corrosion rate was low was observed for the alloys. After the incubation period, the corrosion accelerated, and the corrosion process followed linear kinetics. Effects of alloy, CaO-containing ash, and gas composition on the corrosion rate were also studied. In addition, synchrotron nanobeam X-ray analysis was employed to determine the phase and chemical composition of the oxide layers on the alloy surface. Results from these studies are being used to address the long-term corrosion performance of Fe-based alloys in various coal-ash combustion environments and to develop methods to mitigate high-temperature ash corrosion.

36 MATERIALS SCIENCE↗

Effect of Temper Condition on the Corrosion and Fatigue Performance of AA2219 Aluminum Alloy

The effect of temper condition and corrosion on the fatigue behavior of alloy AA2219 has been investigated in different temper conditions (T87 and T851). Corrosion testing was performed by exposing the tensile specimens to 3.5% NaCl solution for different time periods, and the corrosion damage was quantified using a 3D profilometer. The exposure-tested specimens were subjected for fatigue testing at different stress levels, and the reduction in fatigue life was measured along with detailed fracture morphology variations. The results indicated that the alloy in both tempers suffers localized corrosion damage and the measured corrosion depth was 120 and 1200 µm, respectively, for T87 and T851 conditions. The loss in fatigue strength was found to be high for T851 (67%) when compared to that of T87 temper condition (58%) for a pre-corrosion time of 15 days. In both cases, fatigue crack initiation is associated with corrosion pits, which act as stress raisers. However, the crack propagation was predominantly transgranular for T87 and a mixed transgranular and intergranular fracture in the case of T851 temper condition. This was shown to be due to the heterogeneous microstructure due to the thermomechanical working and the delay in quench time imposed on the alloy forging in T851 temper condition. The findings in this paper present useful information for the selection of appropriate heat treatment condition to facilitate control of the corrosion behavior which is of great significance for their fatigue performance.

36 MATERIALS SCIENCE↗

Effect of Nickel on the Adhesion and Corrosion Ability of Pseudomonas aeruginosa on Stainless Steel

Microbial colonization of metal surfaces or adhesion of bacteria on metal surfaces is a crucial step in initiating microbiologically influenced corrosion. As the substrate is essential in the development of a biofilm, an understanding of how substrate properties affect adhesion of bacterial cells, including the mechanism of bacterial adhesion, may assist in designing or modifying substrates to inhibit bacterial adhesion and prevent the corrosion of materials. A study was carried out to investigate the effect of nickel on the adhesion and corrosion ability of stainless steels with the same chromium content in nutrient-rich simulated seawater containing Pseudomonas aeruginosa. These stainless steels were 201, 316, 304 and 430 stainless steels. In addition, a carbon steel sample with fully nickel coated was included for comparison. The hydrophobicity of different materials was evaluated by measuring the contact angles made by the water, glycerol and formaldehyde. The number of bacteria adhering to the material surface after short-term immersion was counted by fluorescence microscopy. For corrosion study, the corrosion rates and pitting morphology were studied after 42 days of immersion. The corrosion behavior of the samples was also observed by scanning electron microscope (SEM) coupled with energy-dispersive x-ray spectroscopy (EDX) and inductively coupled plasma mass spectrometry (ICPMS). It was found that the nickel-coated sample had the highest level of bacteria attachment and offered poor corrosion resistance under artificial seawater with Pseudomonas aeruginosa strain. Higher nickel content in stainless steel resulted in a higher level of bacteria attachment. It was found that stainless steel with molybdenum exhibited better corrosion resistance in artificial seawater containing bacteria.

36 MATERIALS SCIENCE↗

Chloride-induced corrosion of steel in cracked concrete – Part I: Experimental studies under accelerated and natural marine environments

Parallel corrosion experiments were carried out for 2¼ years by exposing one half of 210 beam specimens (120 × 130 × 375 mm long) to accelerated laboratory corrosion (cyclic wetting and drying) while the other half underwent natural corrosion in a marine tidal zone. Experimental variables were crack width w{sub cr} (0, incipient crack, 0.4, 0.7 mm), cover c (20, 40 mm), binder type (PC, PC/GGBS, PC/FA) and w/b ratio (0.40, 0.55). Results show that corrosion rate (i{sub corr}) was affected by the experimental variables in the following manner: i{sub corr} increased with increase in crack width, and decreased with increase in concrete quality and cover depth. The results also show that the corrosion performance of concretes in the field under natural corrosion cannot be inferred from its performance in the laboratory under accelerated corrosion. Other factors such as corrosion process should be taken into account.

36 MATERIALS SCIENCE↗

Dynamic and static corrosion of chromium-alumina refractory in simulated nuclear waste glass

Monofrax® K-3, a chromium–alumina refractory, is widely used in nuclear waste glass melters due to its high durability. However, aggressive vitrification conditions still lead to corrosion that limits melter lifespan. Here, this study investigates two key corrosion modes, subsurface and melt-line corrosion, under static and dynamic conditions, using a custom setup enabling precise control of melt velocity and temperature. Experimental results, interpreted using diffusion-limited dissolution models, show that (i) subsurface corrosion increases by approximately 10% per mm/s increase in melt velocity, while melt-line corrosion remains virtually unaffected, (ii) corrosion rate dependence on temperature is inversely proportional to melt viscosity, and (iii) glass composition affects both corrosion modes similarly, based on Cr 2 O 3 , Al 2 O 3 , and alkali contents. The experimental data also allowed the determination of diffusion coefficients of major dissolving species, which were found to be consistent between the melt-line and subsurface corrosion models, indicating their suitability for future CFD studies.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Corrosion characteristics of Mo and TZM alloy for plasma facing components in molten lithium at 623 K

Here, in this study, the corrosion behaviours of molybdenum (Mo) and a Mo-based alloy (TZM) were investigated using a static immersion corrosion technique. Weight loss, surface microstructure, and corrosion depth of Mo and the TZM alloy were correlated with elements. The compatibility of Mo and the TZM alloy in static liquid Li was suitable. Mo demonstrated uniform corrosion with a homogenous dissolution of free C and Mo, and TZM alloy exhibited a nonuniform corrosion behaviour with a preferential grain boundary attack caused by the selective dissolution of free C, Ti, and Zr. When the surface oxidation layer of the samples was consumed, free C from Mo and TZM diffused into molten Li to form Li 2 C 2 and then was captured by Zr, Ti, and Mo to form thermodynamically stable carbides, which resulted in the enrichment of the C layer near the sample surfaces. In addition, Ti and Zr acted as N-trappers in liquid Li; the formation of Zr and Ti nitrides resulted in the enrichment of N, Ti, and Zr elements on the surface and led to TZM corrosion increase. Thus, Zr and Ti depletion, pitting, and grain boundary corrosion were problematic for TZM under long-term exposure to liquid Li. Reducing the content of free C and nonmetallic N and increasing the amount of Ti and Zr carbides on the surface of and inside the raw TZM alloy helped improve the corrosion resistance of TZM in liquid Li.

36 MATERIALS SCIENCE↗

Hot corrosion behavior of 304 & P91 graded composite transition joint under molten sulfate salts

A novel graded composite transition joint (GCTJ) between AISI 304 stainless steel and ASTM A335 P91 steel, has been demonstrated remarkablely superior creep performance compared to the conventional dissimilar metal weldment (DMW) under equivalent conditions. However, this advance is challenged by hot corrosion under salt deposition at elevated temperatures. Here, this study investigates the hot corrosion behavior of 304&P91 GCTJ exposed to sulfate salts at 700°C. Compared to the 304 steel, corrosion attacks initiate in the P91 triangle, where the dual-phase microstructure of ferrite and tempered martensite significantly influences pitting initiation. Anodic dissolution mainly occurs within the tempered martensite due to more vulnerable sites within the tempered martensite. With prolonged exposure, corrosion propagates across both phases, and the corrosion depth within the P91 triangle is related to the exposed surface area ratio between 304 and P91. Electrochemical analysis reveals the occurrence of galvanic corrosion between the 304 and P91, with a positive linear relationship between anodic dissolution current density (I a ) and the exposed surface area ratio between 304 and P91 in molten salts, further emphasizing the critical impact of this ratio on the corrosion severity in the P91 triangle. These findings underscore the importance of transition zone design optimization in mitigating localized corrosion.

Galvanic corrosion↗

In situ corrosion analysis of Al-Zn-In-Mg-Ti-Ce sacrificial anode alloy

The corrosion behaviour of Al-5Zn-0.02In-1Mg-0.05Ti-0.5Ce (wt.%) alloy has been investigated by immersion test, scanning electron microscopy, energy dispersive X-ray detector, electrochemical impedance spectroscopy and electrochemical noise. The results show that there exist different corrosion types of the alloy in 3.5% NaCl solution with the immersion time. At the initial stage of immersion, pitting due to the precipitates predominates the corrosion with a typical inductive loop at low frequencies in electrochemical impedance spectroscopy. The major precipitates of the alloy are MgZn{sub 2} and Al{sub 2}CeZn{sub 2} particles. The corrosion potentials of the bulk MgZn{sub 2} and Al{sub 2}CeZn{sub 2} alloys are negative with respect to that of {alpha}-Al, so the MgZn{sub 2} and Al{sub 2}CeZn{sub 2} precipitates can act as activation centre and cause the pitting. In the late corrosion, a relative uniform corrosion predominates the corrosion process controlled by the dissolution/precipitation of the In ions and characterized by a capacitive loop at medium-high frequencies in electrochemical impedance spectroscopy. The potential noise of the pitting shows larger amplitude fluctuation and lower frequency, but the potential noise of the uniform corrosion occurs with smaller amplitude fluctuation and higher frequency.

36 MATERIALS SCIENCE↗

Synergistic Effects of Molten Salt Corrosion and Proton Irradiation on Grain Boundary Strength in Ni-20Cr

Nickel-based alloys are leading contenders for use as structural materials in molten salt reactors. While there have been extensive studies on the impact of fluoride/chloride-based molten salt corrosion on the microstructural evolution of various nickel-based alloys, the effects of simultaneous molten salt corrosion and radiation on the mechanical integrity of grain boundaries (GBs) remain underexplored. In this study, we use a Ni-20Cr model alloy to investigate this issue, subjecting it to simultaneous molten fluoride salt corrosion and proton irradiation. We performed cross-sectional and chemically-sensitive electron microscopy characterization of the microstructures of these materials, identifying the characteristic corrosion-induced microstructure and local chemical heterogeneity near GBs. After developing a sample preparation method for reliable characterization of GB strength, we assess the mechanical degradation of GBs using in situ push-to-pull micro tensile tests. Our findings reveal that voids induced by corrosion are the primary influence on the failure mode of GBs, regardless of whether proton irradiation is present. For materials that exhibit ductile fracture, those subjected to simultaneous corrosion and radiation exhibit lower yield strengths than those exposed to corrosion alone, which may be linked to the previously observed phenomenon of proton irradiation-decelerated intergranular corrosion in molten salt.

36 - MATERIALS SCIENCE↗

Novel textured surfaces for superior corrosion mitigation in molten carbonate salts for concentrating solar power

Corrosion of metals in contact with molten salts used for thermal energy storage and heat transport at high temperatures is a serious impediment to the development of next-generation concentrating solar thermal systems. Toward addressing this limitation, novel multiscale fractal-textured Ni coatings on a variety of substrate alloys are presented in this study for exceptional corrosion mitigation in molten carbonate salts at a high temperature. Strongly adherent, durable, single-layer, and double-layer multiscale fractal coatings were fabricated using the electrodeposition method. Corrosion performance of the coatings on SS310, SS316, SS347, and In800H was studied in molten carbonate salt (32% Li 2 CO 3 +33% Na 2 CO 3 +35% K 2 CO 3 ) at 750 °C. Single-layer coatings are stable up to 300 h immersion, whereas double-layer coatings are stable beyond 750 h. The corrosion rate of double-layer Ni coatings on ferrous alloys was reduced by as much as 60% from that of uncoated surfaces and was about 18% below that of higher cost, high Ni content Ha230. The study represents the first-ever report of corrosion characteristics of alloys in carbonate salts at 750 °C and the first demonstration of a means of dramatically reducing corrosion in carbonate salts at a high temperature. The article is significant in that it provides a viable approach for low-cost structural alloys to be corrosion-resistant to molten carbonate heat transfer fluids and storage media in high-temperature concentrating solar thermal applications. Furthermore, the corrosion-resistant coatings provide opportunities for the use of low-cost, ferritic alloys instead of the expensive nickel-based alloys in practice.

14 SOLAR ENERGY↗

Electrodeposited nickel coatings for exceptional corrosion mitigation in industrial grade molten chloride salts for concentrating solar power

Molten chloride salt eutectics are attractive candidates for use as thermal energy storage media and heat transfer fluids in generation-three concentrating solar thermal power (Gen3 CSP) plants. However, corrosion of alloys in molten chloride salts, especially at high temperatures, is an extremely challenging problem that studies focus on lower temperatures, shorter durations, or analytical grade, and high-purity, salts. To date, there has been no study on corrosion or corrosion mitigation in an industrial-grade salt at a high temperature such as 750 °C. To alleviate this knowledge gap, the study presents new multiscale fractal-textured Ni coatings on various alloy surfaces for effective corrosion mitigation at 750 °C in molten chloride salts. Using the electrodeposition method, durable double-layer textured coatings were formed on stainless steel alloys (SS316, SS310, and SS347) and In800H. The corrosion performance of the coatings is investigated in both analytical-grade purity and, for the first time, practically relevant industrial-grade chloride salts. Ni-coated ferrous alloys showed an exceptionally reduced corrosion rate in the range of 350–480 μm/y in analytical-grade salts, and between 450 and 490 μm/y in purified industrial-grade salts at 750 °C. Ni coatings on ferrous alloys reduced corrosion rates by as much as 70% compared to uncoated surfaces and were comparable to the expensive Ha230 alloy with a high Ni content. As a result, by the use of innovative fractal corrosion mitigation coatings, for the first time, low-cost structural alloys are rendered viable for use with industrial-grade chloride salts, which is profoundly beneficial in practical systems.

14 SOLAR ENERGY↗

Electrochemical techniques and mechanisms for the corrosion of metals and alloys in sub- and supercritical aqueous systems

Corrosion has become a decisive factor hindering supercritical water technologies' long-cycle, safe implementation. Electrochemical experiments performed in supercritical aqueous systems can capture essential, real-time information about the micro/nanoscale processes of corrosion and their kinetics. As a starting point, this paper first summarizes the critical chemical properties of supercritical aqueous systems and analyzes their role in determining the duality of corrosion mechanisms (whether electrochemical or chemical micro-processes predominate). Next, it reviews the available electrochemical techniques such as pH sensors, electrochemical noise measurements, and related applications for quantitatively elaborating the corrosion issues in supercritical aqueous systems. With thick and heavy colors, a series of mechanistic models, such as the mixed potential model and the coupled environment models were introduced from the fundamental theories to the related applications, which have been applied widely in ambient and subcritical aqueous systems and exhibit great values and potential to be employed in high-density supercritical water environments. The passivity, depassivation, and passivity breakdown of metals and alloys in terms of the Point Defect Model (PDM) were also successfully implemented and discussed. Further, the newly built SCW_PDM describes the film growth kinetics at the atomic level of metals and alloys in supercritical water and is being developed to quantitatively analyze and resolve a series of corrosion issues such as the passivity breakdown and the stress corrosion cracking that occur in supercritical aqueous systems. This review is helpful by promoting the development of the electrochemical corrosion theory in supercritical aqueous systems and by identifying corrosion prevention and control methods for the safe implementation of relevant supercritical water technologies.

36 MATERIALS SCIENCE↗

Corrosion resistance of MCrAlX coatings in a molten chloride for thermal storage in concentrating solar power applications

Corrosion evaluations of Incoloy 800 H (In800H) and stainless steel AISI 310 (310SS), in bare and coated conditions, were performed in 34.42 wt% NaCl – 55.47 wt% KCl at 700 °C in a nitrogen atmosphere. This NaCl–KCl composition has a melting point of 657 °C, which makes it suitable for latent-heat thermal energy storage in concentrating solar power applications. Several nickel-based MCrAlX coatings were tested, where M = Ni and/or Co and X = Y, Ta, Hf, and/or Si. Electrochemical testing was carried out to determine corrosion rates. The bare In800H and 310SS alloys corroded rapidly (~2500 and 4500 µm/yr, respectively, assuming uniform corrosion). Concentrating solar power plants need containment materials with a lifetime of at least 30 years; thus, these corrosion rates are excessive. Corrosion mitigation approaches are being investigated to obtain degradation on the order of 20 µm/yr or lower. The lowest corrosion rate of 190 µm/yr was obtained for atmospheric plasma spray NiCoCrAlY coatings pre-oxidized in air at 900 °C for 24 h with a heating/cooling rate of 0.5 °C/min. Metallographic characterization of the corroded surfaces showed that the formation of a uniform thin alumina scale before exposure to the molten chloride system considerably reduced the corrosion of the alloy. However, the rates of corrosion determined herein are considerable, highlighting the relevance of testing materials durability in solar power applications.

14 SOLAR ENERGY↗

Localized corrosion of low-carbon steel at the nanoscale

Abstract Mitigating corrosion remains a daunting challenge due to localized, nanoscale corrosion events that are poorly understood but are known to cause unpredictable variations in material longevity. Here, the most recent advances in liquid-cell transmission electron microscopy were employed to capture the advent of localized aqueous corrosion in carbon steel at the nanoscale and in real time. Localized corrosion initiated at a triple junction formed by a solitary cementite grain and two ferrite grains and then continued at the electrochemically-active boundary between these two phases. With this analysis, we identified facetted pitting at the phase boundary, uniform corrosion rates from the steel surface, and data that suggest that a re-initiating galvanic corrosion mechanism is possible in this environment. These observations represent an important step toward atomically defining nanoscale corrosion mechanisms, enabling the informed development of next-generation inhibition technologies and the improvement of corrosion predictive models.