Examination, evaluation and repair of laminated wood blades after service on the Mod-OA wind turbine

Laminated wood blades were designed, fabricated, and installed on a 200-KW wind turbine (Mod-OA). The machine uses a two-blade rotor with a diameter of 38.1 m (125 ft). Each blade weights less than 1361 kg (3000 lb). After operating in the field, two blade sets were returned for inspection. One set had been in Hawaii for 17 months (7844 hr of operation) and the other had been at Block Island, Rhode Island, for 26 months (22 months operating - 7564 hr). The Hawaii set was returned because of one of the studs that holds the blade to the hub had failed. This was found to be caused by a combination of improper installation and inadequate corrosion protection. No other problems were found. The broken stud (along with four others that were badly corroded) was replaced and the blades are now in storage. The Block Island set of blades was returned at the completion of the test program, but one blade was found to have developed a crack in the leading edge along the entire span. This crack was found to be the result of a manufacturing process problem but was not structurally critical. When a load-deflection test was conducted on the cracked blade, the response was identical to that measured before installation. In general, the laminate quality of both blade sets was excellent. No significant internal delamination or structural defects were found in any blade. The stud bonding process requires close tolerance control and adequate corrosion protection, but studs can be removed and replaced without major problems. Moisture content stabilization does not appear to be a problem, and laminated wood blades are satisfactory for long-term operation on Mod-OA wind turbines.

Faddoul, J. R.↗

Mechanism of strength degradation for hot corrosion of alpha-SiC

Sintered alpha SiC was corroded by thin films of Na2SO4 and Na2CO3 molten salts at 1000%. This hot corrosion attack reduced room temperature strengths by as much as 50%. Strength degradation was porportional to the degree and uniformity of corrosion pitting attack as controlled by the chemistry of the molten salt. Extensive fractography identified corrosion pits as the most prevalent source of failure. A fracture mechanics treatment of the strength/pit depth relationship produced an average K sub IC equal to 2.6 MPa sub m 1/2, which is consistent with published values.

Smialek, J. L.↗

Mechanism of strength degradation for hot corrosion of alpha-SiC

Sintered alpha SiC was corroded by thin films of Na2SO4 and Na2CO3 molten salts at 1000 percent. This hot corrosion attack reduced room temperature strengths by as much as 50 percent. Strength degradation was proportional to the degree and uniformity of corrosion pitting attack as controlled by the chemistry of the molten salt. Extensive fractography identified corrosion pits as the most prevalent source of failure. A fracture mechanics treatment of the strength/pit depth relationship produced an average K sub IC equal to 2.6 MPa sub m 1/2, which is cnsistent ith published values.

Smialek, James L.↗

NASA Tech Briefs, November 2010

Topics covered include: Portable Handheld Optical Window Inspection Device; Salience Assignment for Multiple-Instance Data and Its Application to Crop Yield Prediction; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems ; Predicting Long-Range Traversability from Short-Range Stereo-Derived Geometry; Browser-Based Application for Telemetry Monitoring of Robotic Assets; Miniature Low-Noise G-Band I-Q Receiver; Methods of Using a Magnetic Field Response Sensor Within Closed, Electrically Conductive Containers; Differential Resonant Ring YIG Tuned Oscillator; Microfabricated Segmented-Involute-Foil Regenerator for Stirling Engines; Reducing Seal Adhesion in Low Impact Docking Systems; Optimal Flow Control Design; Corrosion-Resistant Container for Molten-Material Processing; Reusable Hot-Wire Cable Cutter; Deployment of a Curved Truss; High-Volume Airborne Fluids Handling Technologies to Fight Wildfires; Modeling of Alkane Oxidation Using Constituents and Species; Fabrication of Lanthanum Telluride 14-1-11 Zintl High-Temperature Thermoelectric Couple; A Computer Model for Analyzing Volatile Removal Assembly; Analysis of Nozzle Jet Plume Effects on Sonic Boom Signature; Optical Sidebands Multiplier; Single Spatial-Mode Room-Temperature-Operated 3.0 to 3.4 micrometer Diode Lasers; Self-Nulling Beam Combiner Using No External Phase Inverter; Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis; Maximum Likelihood Time-of-Arrival Estimation of Optical Pulses via Photon-Counting Photodetectors; Handheld White Light Interferometer for Measuring Defect Depth in Windows; Decomposition Algorithm for Global Reachability on a Time-Varying Graph; Autonomous GN and C for Spacecraft Exploration of Comets and Asteroids; Efficient Web Services Policy Combination; Using CTX Image Features to Predict HiRISE-Equivalent Rock Density; Isolation of the Paenibacillus phoenicis, a Spore-Forming Bacterium; Monolithically Integrated, Mechanically Resilient Carbon-Based Probes for Scanning Probe Microscopy; Cell Radiation Experiment System; Process to Produce Iron Nanoparticle Lunar Dust Simulant Composite; Inversion Method for Early Detection of ARES-1 Case Breach Failure; Use of ILTV Control Laws for LaNCETS Flight Research;and Evaluating Descent and Ascent Trajectories Near Non-Spherical Bodies.

Source record↗

Corrosion Electrochemistry of Chromium in Molten FLiNaK Salt at 600 °C

The manuscript revisits the corrosion behavior of pure Cr in molten FLiNaK salt at 600 °C from the perspective of corrosion electrochemistry. In this work, the potential-dependent, rate-limiting charge-transfer, and salt film-mediated mass-transport controlled regimes of Cr corrosion in FLiNaK at 600 °C are investigated. The kinetic and thermodynamic parameters that limit electrodissolution and the consideration of grain orientation on these regimes are elucidated. At low Cr(III) concentrations, the corrosion process is governed by charge transfer control at low overpotentials and is crystal orientation dependent. However, when Cr(III) concentrations are high or when there is a high overpotential, the formation of a metal fluoride salt film on the Cr surface shifts the kinetic behavior to be governed by mass transport control at all anodic potentials with a surface morphology controlled by salt film deposition location and identity. Evan’s diagrams were developed to consolidate and elucidate these observations. These findings were supported by an examination of the post-corrosion microstructure, X-ray diffraction of solidified salts, and thermo-kinetics analysis in each corrosion regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Overview of Liquid Fluoride Salt Heat Transport Systems

Heat transport is central to all thermal-based forms of electricity generation. The ever increasing demand for higher thermal efficiency necessitates power generation cycles transitioning to progressively higher temperatures. Similarly, the desire to provide direct thermal coupling between heat sources and higher temperature chemical processes provides the underlying incentive to move toward higher temperature heat transfer loops. As the system temperature rises, the available materials and technology choices become progressively more limited. Superficially, fluoride salts at {approx}700 C resemble water at room temperature being optically transparent and having similar heat capacity, roughly three times the viscosity, and about twice the density. Fluoride salts are a leading candidate heat-transport material at high temperatures. Fluoride salts have been extensively used in specialized industrial processes for decades, yet they have not entered widespread deployment for general heat transport purposes. This report does not provide an exhaustive screening of potential heat transfer media and other high temperature liquids such as alkali metal carbonate eutectics or chloride salts may have economic or technological advantages. A particular advantage of fluoride salts is that the technology for their use is relatively mature as they were extensively studied during the 1940s-1970s as part of the U.S. Atomic Energy Commission's program to develop molten salt reactors (MSRs). However, the instrumentation, components, and practices for use of fluoride salts are not yet developed sufficiently for commercial implementation. This report provides an overview of the current understanding of the technologies involved in liquid salt heat transport (LSHT) along with providing references to the more detailed primary information resources. Much of the information presented here derives from the earlier MSR program. However, technology has evolved over the intervening years, and this report also describes more recently developed technologies such as dry gas seals. This report also provides a high-level, parametric evaluation of LSHT loop performance to allow general intercomparisons between heat-transport fluid options as well as provide an overview of the properties and requirements for a representative loop. A compilation of relevant thermophysical properties of useful fluoride salts is also included for salt heat transport systems. Fluoride salts can be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report includes an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize corrosion issues. Salt chemistry control technology, however, remains at too low a level of understanding for widespread industrial usage. Loop operational issues such as start-up procedures and system freeze-up vulnerability are also discussed. Liquid fluoride salts are a leading candidate heat transport medium for high-temperature applications. This report provides an overview of the current status of liquid salt heat transport technology. The report includes a high-level, parametric evaluation of liquid fluoride salt heat transport loop performance to allow intercomparisons between heat-transport fluid options as well as providing an overview of the properties and requirements for a representative loop. Much of the information presented here derives from the earlier molten salt reactor program and a significant advantage of fluoride salts, as high temperature heat transport media is their consequent relative technological maturity. The report also includes a compilation of relevant thermophysical properties of useful heat transport fluoride salts. Fluoride salts are both thermally stable and with proper chemistry control can be relatively chemically inert. Fluoride salts can, however, be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report also provides an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize salt corrosion as well as providing a general discussion of heat transfer loop operational issues such as start-up procedures and freeze-up vulnerability.

heat transfer↗

Effects of Amines on the Surface Charge Poperties of Iron Oxides.

Specific studies detailing the effects of amines, used as pH control agents for corrosion inhibition in power plants, on the surface charge of iron oxides provide data to assess the mechanism of how these amines impact deposition rate. The current study was undertaken in order to determine accurately the dissociation constants of the relevant amines at Pressurized Water Reactor (PWR) operating conditions and to investigate the effect of sorption of two of these amines (morpholine and dimethylamine) by magnetite. The acid-dissociation equilibria of morpholine (MOR), dimethylamine (DMA) and ethanolamine (ETA) were measured potentiometrically with a hydrogen-electrode concentration cell (HECC) from 0 to 290 C in sodium trifluoromethanesulfonate (NaTr) solutions at ionic strengths up to 1 mol {center_dot} kg{sup -1}. Magnetite surface titrations were performed at an ionic strength of 0.03 mol {center_dot} kg{sup -1} (NaTr medium) in the presence or absence of morpholine and dimethylamine buffers over a wide range of pH and total amine concentrations at 150-250 C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High performance III-V photoelectrodes for solar water splitting via synergistically tailored structure and stoichiometry

Abstract Catalytic interface of semiconductor photoelectrodes is critical for high-performance photoelectrochemical solar water splitting because of its multiple roles in light absorption, electrocatalysis, and corrosion protection. Nevertheless, simultaneously optimizing each of these processes represents a materials conundrum owing to conflicting requirements of materials attributes at the electrode surface. Here we show an approach that can circumvent these challenges by collaboratively exploiting corrosion-resistant surface stoichiometry and structurally-tailored reactive interface. Nanoporous, density-graded surface of ‘black’ gallium indium phosphide (GaInP 2 ), when combined with ammonium-sulfide-based surface passivation, effectively reduces reflection and surface recombination of photogenerated carriers for high efficiency photocatalysis in the hydrogen evolution half-reaction, but also augments electrochemical durability with lifetime over 124 h via strongly suppressed kinetics of corrosion. Such synergistic control of stoichiometry and structure at the reactive interface provides a practical pathway to concurrently enhance efficiency and durability of semiconductor photoelectrodes without solely relying on the development of new protective materials.

14 SOLAR ENERGY↗

Pit growth kinetics in aluminum: effects of salt loading and relative humidity

Abstract The growth kinetics of localized corrosion, e.g. pits, in corrosive environments often controls the service life of metallic components. Yet, our understanding of these kinetics is largely based on coupon-level, e.g. mass-loss, studies which provide limited insights into the evolution of individual damage events. It is critical to relate observed cumulative loss trends, such as links between changing humidity and mass loss rates, to the growth kinetics of individual pits. Towards this goal, we leverage in-situ X-ray computed tomography to measure the growth rates of over sixty pits in aluminum in four different humid, chloride environments over ≈3 days of exposure. Pit growth rates and final volumes increased with increasing droplet volume, which was observed to increase with increasing humidity and salt loading. Two factors, droplet spreading and oxide jacking, dramatically increased pit growth rates and final volumes.

Noell, Philip J. (ORCID:0000000346998999)↗

Improved High-Alkali Low-Activity Waste Formulations. VSL-15R3290-1, Rev. 0 (Final Report)

The Office of River Protection is examining options to optimize the Low Activity Waste (LAW) Facility and LAW glass waste form. One option under evaluation is to enhance the waste processing rate of the vitrification plant currently under construction. It is likely that the capacity of the LAW vitrification plant can be increased incrementally by implementation of a variety of low-risk, high-probability changes, either separately or in combination. The Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) and EnergySolutions, Inc. have evaluated several of these potential incremental improvements for ORP in support of its evaluation of WTP LAW facility optimization. The present work was conducted using a Hanford LAW composition with low sulfur-to-sodium ratio with the objective of determining the maximum waste loading that can be achieved without Cr 2 O 3 addition by employing alternatives to control K-3 corrosion. LAW from Hanford Tank AN-105 and the glass formulation ORPLA20, which was previously developed to treat this waste, were selected as the base compositions for this study. As shown in Table 1.1, the ORPLA20 glass composition has a waste loading of 31.5 wt% and a sodium content of 24 wt% Na 2 O. Other major components contributed by the waste are Al 2 O 3 , SO 3 , Cl and K 2 O at concentrations of 5.55, 0.70, 0.67 and 0.53 wt%, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of commercial equipment and instrumentation for Spacelab payloads. Volume 3: Design analysis and trade studies

A detailed analysis is presented of each selected equipment item, and suitability and cost analyses were documented by equipment item. Tradeoffs of alternative specification requirements are presented which include possible relaxation of vibration, material control, fungus and corrosion requirements for experiment equipment. An additional tradeoff was performed to determine whether it is cost effective to modify experiment equipment to be compatible with a 28-volt dc power source rather than the conventional 110-volt ac source. Programmatic analysis data are given which were used as the basis for the extension of results from the analyses of specific equipment items to the entire spacelab experiment program.

Source record↗

Ozone inhibits corrosion in cooling towers

Commercially available corona discharge ozone generator, fitted onto industrial cooling tower, significantly reduces formation of scales (calcium carbonate) and corrosion. System also controls growth of algae and other microorganisms. Modification lowers cost and improves life of cooling system.

French, K. R.↗

Potential Alternatives Report for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes

Identifying and selecting alternative materials and technologies that have the potential to reduce the identified HazMats and hazardous air pollutants (HAPs), while incorporating sound corrosion prevention and control technologies, is a complicated task due to the fast pace at which new technologies emerge and rules change. The alternatives are identified through literature searches, electronic database and Internet searches, surveys, and/or personal and professional contacts. Available test data was then compiled on the proposed alternatives to determine if the materials meet the test objectives or if further)laboratory or field-testing will be required. After reviewing technical information documented in the PAR, government representatives, technical representatives from the affected facilities, and other stakeholders involved in the process will select the list of viable alternative coatings for consideration and testing under the project's Joint Test Protocol entitled Joint Test Protocol for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes and Field Test Plan entitled Field Evaluations Test Plan for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes, both prepared by ITB. Test results will be reported in a Joint Test Report upon completion oftesting. The selection rationale and conclusions are documented in this PAR. A cost benefit analysis will be prepared to quantify the estimated capital and process costs of coating alternatives and cost savings relative to the current coating processes, however, some initial cost data has been included in this PAR. For this coatings project, isocyanates, as found in aliphatic isocyanate polyurethanes, were identified as the target HazMat to be eliminated. Table 1-1 lists the target HazMats, the related process and application, current specifications, and affected programs.

Lewis, pattie↗

First-Principles Modeling of the Repassivation of Corrosion Resistant Alloys: Part I. O and Cl Adsorption Energy

To understand the mechanism of repassivation, a key process that controls the performance of corrosion resistant alloys (CRAs), it is useful to obtain some fundamental parameters that describe the atomistic processes. Oxygen and chlorine adsorption energies were systematically calculated with density functional theory for Ni-22Cr alloys with seven different solute elements: Co, Cu, Fe, Mn, Mo, Ru and W. All elements other than Cu enhance both O and Cl adsorption to alloy surfaces. Cr has the strongest effect among these elements. Surface configurations that give stronger O adsorption also tend to give stronger Cl adsorption. While this makes it difficult to differentiate the effect of these solute elements on the oxidation/repassivation tendency of alloys, these fundamental properties provide the foundation for higher scale models that could be used to study the oxidation process during corrosion and potentially inform the design of CRAs. Bader charge analysis reveals a strong relationship between the adatom adsorption energy and the Bader charges of both O and Cl adatom. In conclusion, the work function of alloy surfaces is increased by O while decreased by Cl, suggesting that Cl adsorption can have an intrinsic negative impact on corrosion resistance by decreasing the barrier to electron transfer.

36 MATERIALS SCIENCE↗

Controlled thermal pre-treatment of ZMG232G10® for corrosion mitigation under simulated SOFC interconnect exposure conditions

The IT-SOFC candidate interconnect material ZMG232G10® was thermally pre-treated in air and in H 2 – 3% H 2 O to mitigate dual atmosphere corrosion. Bare and pre-treated steel samples were exposed to a dual atmosphere exposure condition (dry air/metal/4% H 2 – N 2 (bal.) + 3% H 2 O) for 500h at 600°C. Corrosion products and oxide morphology developed on the air-exposed surfaces were analyzed. Pre-treatments of the metal in oxidizing (air) and reducing (H 2 – 3% H 2 O) gas atmospheres provide improved passivation against dual atmosphere corrosion compared to bare steel. Further, the uniform and iron-free oxide scale developed during the pre-treatment of alloy in the low pO 2 H 2 – 3% H 2 O gas atmosphere provides an effective diffusion barrier against the outward transport of cations and oxidation of iron observed under dual atmosphere conditions.

36 MATERIALS SCIENCE↗

Micro-Continuum Modeling of Nuclear Waste Glass Corrosion

The purpose of this contribution is to report on preliminary nano-continuum scale modeling of nuclear waste glass corrosion. The focus of the modeling is an experiment involving a French glass SON68 specimen leached for 25 years in a granitic environment (Guittonneau et al., 2011; Gin et al., 2011; Gin et al., 2013). The 25 year experiment carried out by French scientists offers a unique opportunity to examine the controls on the rate of nuclear glass corrosion under controlled experimental conditions using a borosilicate glass of the kind widely considered for nuclear waste storage. The long term experiment makes it possible to move beyond the initial rate stage, with direct measurements of the longer term, residual rates of corrosion. Important in this regard is whether the rate of corrosion shows a parabolic dependence on time, as would be expected from a conventional diffusion model in which the reaction products (amorphous silica-rich gel) create a diffusion barrier that grows in width over time, or whether the time dependence is linear (Guittonneau et al., 2011). A linear dependence on time would call into question the model of a Passive Reactive Interface (PRI) presented by Cailleteau et al. (2008), although it does not entirely preclude such a model if the interface maintains a constant width over time (forming at the leading edge next to the pristine glass and dissolving at the trailing edge). The leachate concentration measurements collected every 56 days over 25 years by Guittonneau et al. (2011) provide data to constrain the long term corrosion rate and its time dependence.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GNF fuel and channel performance: 2016 update

GNF2 is an advanced 10*10 BWR fuel design that was initially introduced in reload quantities in 2008. It has now replaced GE14 as the fuel design with the largest number of bundles in the operating fleet. Utilities are reaping the benefits of improved nuclear and thermal performance as well as high reliability. Transition to GNF2 fuel in the fleet is nearly complete with only three plants continuing to receive GE14 fuel in 2016. GNF2 reload bundles are now being discharged, and inspections have been completed on GNF2 bundles operated to over 61 GWd/MT and over 7.5 years. For both GE14 and GNF2, 2015 was a challenging year in terms of fuel reliability, with an increase in debris-related failures. The failures are concentrated in pumped-forward drain plants (that have long showed increased susceptibility to debris issues), plants with histories of recurrent debris failures, and in some cases in plants that had component failures or unusual or extensive maintenance or modifications. There have been no failures from causes other than debris. In GNF2, there are no failures due to manufacturing, PCI-type, dryout, or any form related to crud or corrosion. Operating experience in 2015 (and over the past decade) is discussed in terms of Failed Fuel Management, or operation with fuel failures in the core, and channel - control blade interference. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗