Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTROL SIMULATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing and Implementing the Data Mining Algorithms in RAVEN

The RAVEN code is becoming a comprehensive tool to perform probabilistic risk assessment, uncertainty quantification, and verification and validation. The RAVEN code is being developed to support many programs and to provide a set of methodologies and algorithms for advanced analysis. Scientific computer codes can generate enormous amounts of data. To post-process and analyze such data might, in some cases, take longer than the initial software runtime. Data mining algorithms/methods help in recognizing and understanding patterns in the data, and thus discover knowledge in databases. The methodologies used in the dynamic probabilistic risk assessment or in uncertainty and error quantification analysis couple system/physics codes with simulation controller codes, such as RAVEN. RAVEN introduces both deterministic and stochastic elements into the simulation while the system/physics code model the dynamics deterministically. A typical analysis is performed by sampling values of a set of parameter values. A major challenge in using dynamic probabilistic risk assessment or uncertainty and error quantification analysis for a complex system is to analyze the large number of scenarios generated. Data mining techniques are typically used to better organize and understand data, i.e. recognizing patterns in the data. This report focuses on development and implementation of Application Programming Interfaces (APIs) for different data mining algorithms, and the application of these algorithms to different databases.

97 MATHEMATICS AND COMPUTING↗

Biaxial constitutive equation development for single crystals

Current gas turbine engines utilize large single crystal superalloy components in the hot section. Structural analysis of these components requires a valid stress strain temperature constitutive equation. The goal of the program described is to create one or more models and verify these models. A constitutive equation based on an assumed slip behavior of a single slip system was formulated, programmed, and debugged. Specifically, the basic theory for a model based on aggravating slip behavior on individual slip systems was formulated and programmed and some simulations were run using assumed values of constants. In addition, a formulation allowing strain controlled simulations was completed. An approach to structural analysis of the specimen was developed. This approach uses long tube consistancy conditions and finite elements specially formulated to take advantage of the symmetry of 100 oriented specimens.

Jordan, E. H.↗

Human-Automation Cooperation for Separation Assurance in Future NextGen Environments

A 2012 Human-In-The-Loop air traffic control simulation investigated a gradual paradigm-shift in the allocation of functions between operators and automation. Air traffic controllers staffed five adjacent high-altitude en route sectors, and during the course of a two-week experiment, worked traffic under different function-allocation approaches aligned with four increasingly mature NextGen operational environments. These NextGen time-frames ranged from near current-day operations to nearly fully-automated control, in which the ground systems automation was responsible for detecting conflicts, issuing strategic and tactical resolutions, and alerting the controller to exceptional circumstances. Results indicate that overall performance was best in the most automated NextGen environment. Safe operations were achieved in this environment for twice todays peak airspace capacity, while being rated by the controllers as highly acceptable. However, results show that sector operations were not always safe; separation violations did in fact occur. This paper will describe in detail the simulation conducted, as well discuss important results and their implications.

air traffic control↗

Parabolic Deformable Mirror Testbed for the ExoSpec Project

The ExoSpec Project is a NASA Headquarters directed work package that links four different tasks at Goddard Space Flight Center to enable future missions to more efficiently characterize directly imaged exoplanets. One of the tasks is the development of parabolic deformable mirrors to improve on the current state-of-the-art wavefront sensing and control implementations, which are baselined to have two flat deformable mirrors (DMs) with high actuator count. To effectively control both amplitude and phase aberrations, the flat DMs need to have a large separation, which poses packaging challenges to missions designed to image rocky exoplanets. To eliminate this large separation, the parabolic DM architecture makes the off-axis imaging elements in the optical train controllable. Simulations also show performance enhancements with the architecture change; larger bandwidths have been shown to be controllable with the parabolic DMs and the number of required actuators can be reduced. With a 32×32 pupil flat DM and two 16x16 parabolic DMs, we could obtain a 5 - 12λ/D dark hole at 35%bandwidth. In addition to addressing the packaging challenge faced by future coronagraph missions, reducing the number of actuators reduces both cost and risk of having the entire coronagraph instrument’s performance depend on two high-actuator count DMs. To test these simulations, Goddard is building a testbed and has a vendor developing the parabolic DM. Here we present these simulations, the current testbed performance, and the development plan to incorporate and test the parabolic DMs

Coronagraph↗

Modeling and Simulation Supporting Material Control and Accounting for Advanced Reactors: Task 2: Safeguards Modeling and Simulation Assessment

Commercial interest in advanced reactors for power production in the United States is increasing. A variety of advanced reactor designs are being developed, and many of them use non-traditional fuel forms. Therefore, the material control and accounting (MC&A) methods that will be required for these advanced reactor systems also need to be developed to ensure that the necessary safeguards are implemented. To provide information that can be leveraged to explore different MC&A approaches, three representative advanced reactor types were evaluated from a technical safeguards perspective. These reactor designs were selected to encompass common materials and configurations that could affect safeguards considerations. The three designs evaluated were a molten salt reactor (MSR), a gas-cooled reactor (GCR), and a heat pipe-cooled microreactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feasibility study of a procedure to detect and warn of low level wind shear

A Doppler radar system which provides an aircraft with advanced warning of longitudinal wind shear is described. This system uses a Doppler radar beamed along the glide slope linked with an on line microprocessor containing a two dimensional, three degree of freedom model of the motion of an aircraft including pilot/autopilot control. The Doppler measured longitudinal glide slope winds are entered into the aircraft motion model, and a simulated controlled aircraft trajectory is calculated. Several flight path deterioration parameters are calculated from the computed aircraft trajectory information. The aircraft trajectory program, pilot control models, and the flight path deterioration parameters are discussed. The performance of the computer model and a test pilot in a flight simulator through longitudinal and vertical wind fields characteristic of a thunderstorm wind field are compared.

Turkel, B. S.↗

Steady-state simulation program for attitude control propulsion systems

The formulation and the engineering equations employed in the steady state attitude control propulsion system simulation program are presented. The objective of this program is to aid in the preliminary design and development of propulsion systems used for spacecraft attitude control. The program simulates the integrated operation of the many interdependent components typically comprising an attitude control propulsion system. Flexibility, generality, ease of operation, and speed consistent with adequate accuracy were overriding considerations during the development of this program. Simulation modules were developed representing the various types of fluid components typically encountered in an attitude control propulsion system. These modules are basically self-contained and may be arranged by the program user into desired configuration through the program input data.

Heinmiller, P. J.↗

Proceedings of the 3rd Annual Conference on Aerospace Computational Control, volume 1

Conference topics included definition of tool requirements, advanced multibody component representation descriptions, model reduction, parallel computation, real time simulation, control design and analysis software, user interface issues, testing and verification, and applications to spacecraft, robotics, and aircraft.

Bernard, Douglas E.↗

L2 Earth Atmosphere Observatory: Formation Guidance, Metrology and Control Synthesis

The Earth Observatory Formation at L2, a Lagrange libration point, is a unique large aperture (25 m diameter) space telescope concept that will improve the knowledge and understanding of dynamic, chemical and radiative mechanisms that cause changes in the atmosphere, and can lead to the development of models and techniques to predict short and long-term climate changes. The results of this concept definition study show that the telescope concept is feasible, and can have technology readiness in the 2020 time frame. Further advanced development in several subsystems is needed, such as higher efficiency Xenon ion thrusters with throttling, and optical quality large membrane mirror with active shape control. It presents an analysis and solution of guidance, sensing, control, and propulsion problems for a formation of two spacecraft on the Sun-Earth line in the neighborhood of the Sun-Earth L2 point, that observes Earth s atmosphere during continuous solar occultation by the Earth. A system architecture is described for the observatory, and its components that include unique mission specific metrology. The formation must follow a powered trajectory with strictly limited fuel use to observe solar occultation. A configuration of ion thrusters and reaction wheels for translation and attitude control is designed along with algorithms for orbit following and formation control. Simulation results of the orbital and formation dynamics are presented that verify performance of the control systems.

Earth Atmosphere Observatory Formation↗

Generic Airspace Concepts and Research

The purpose of this study was to evaluate methods for reducing the training and memorization required to manage air traffic in mid-term, Next Generation Air Transportation System (NextGen) airspace. We contrasted the performance of controllers using a sector information display and NextGen automation tools while working with familiar and unfamiliar sectors. The airspace included five sectors from Oakland and Salt Lake City Centers configured as a "generic center" called "West High Center." The Controller Information Tool was used to present essential information for managing these sectors. The Multi Aircraft Control System air traffic control simulator provided data link and conflict detection and resolution. There were five experienced air traffic controller participants. Each was familiar with one or two of the five sectors, but not the others. The participants rotated through all five sectors during the ten data collection runs. The results addressing workload, traffic management, and safety, as well as controller and observer comments, supported the generic sector concept. The unfamiliar sectors were comparable to the familiar sectors on all relevant measures.

Mogford, Richard H.↗

Sampling the ENSO response to tropical volcanic eruptions in the GISS-E2-1 model: physical & biogeochemical ocean effects

Despite observational evidence that an El-Niño is likely to follow tropical volcanic eruptions (Predybaylo et al, 2017), modelling studies have so far reached no consensus on either the sign or physical mechanism of El Niño response to volcanism (Khodri et al, 2017) . A previous modelling study found that following the Pinatubo eruption, the tropical Pacific developed El Niño-like conditions that triggered a decrease in the upwelling of DIC and increased carbon uptake (Eddebbar et al., 2019). However, the carbon cycle response to volcanisms as it depends on ENSO phase remains unclear. Here we perform thirty ensemble control simulations using the GISS-E2-1-G model to sample the pre-industrial control ENSO cycle and thirty more to superimpose a Pinatubo-like volcanic eruption. We find that the model tends to favor the development of a weak El-Niño following the volcanic eruption only in the case of a volcano that erupts at the start of a neutral ENSO phase. In response to the weak El-Niño, some anomalies have the same sign as those that develop from a strong El-Niño, such as weaker winds, shallower mixed layer depths, less direct but more diffuse radiation at the surface of the ocean, less nitrate, and lower primary productivity. However, other anomalies show the opposite sign as those from a strong El-Niño, such as more precipitation, less surface DIC, and less surface ocean pCO 2 . In contrast to the neutral phase, the volcanic response during positive ENSO and negative ENSO phases are swamped by the model’s internal variability.

ENSO↗

HYTESS 2: A Hypothetical Turbofan Engine Simplified Simulation with multivariable control and sensor analytical redundancy

A hypothetical turbofan engine simplified simulation with a multivariable control and sensor failure detection, isolation, and accommodation logic (HYTESS II) is presented. The digital program, written in FORTRAN, is self-contained, efficient, realistic and easily used. Simulated engine dynamics were developed from linearized operating point models. However, essential nonlinear effects are retained. The simulation is representative of the hypothetical, low bypass ratio turbofan engine with an advanced control and failure detection logic. Included is a description of the engine dynamics, the control algorithm, and the sensor failure detection logic. Details of the simulation including block diagrams, variable descriptions, common block definitions, subroutine descriptions, and input requirements are given. Example simulation results are also presented.

Merrill, W. C.↗

Neuroevolution Application to Collaborative and Heuristics-Based Connected and Autonomous Vehicle Cohort Simulation at Uncontrolled Intersection

Artificial intelligence is gaining tremendous attractiveness and showing great success in solving various problems, such as simplifying optimal control derivation. This work focuses on the application of Neuroevolution to the control of Connected and Autonomous Vehicle (CAV) cohorts operating at uncontrolled intersections. The proposed method implementation’s simplicity, thanks to the inclusion of heuristics and effective real-time performance are demonstrated. The resulting architecture achieves nearly ideal operating conditions in keeping the average speeds close to the speed limit. It achieves twice as high mean speed throughput as a controlled intersection, hence enabling lower travel time and mitigating energy inefficiencies from stop-and-go vehicle dynamics. Low deviation from the road speed limit is hence continuously sustained for cohorts of at most 50 m long. This limitation can be mitigated with additional lanes that the cohorts can split into. The concept also allows the testing and implementation of fast-turning lanes by simply replicating and reconnecting the control architecture at each new road crossing, enabling high scalability for complex road network analysis. The controller is also successfully validated within a high-fidelity vehicle dynamic environment, showing its potential for driverless vehicle control in addition to offering a new traffic control simulation model for future autonomous operation studies.

Jacquelin, Frederic (ORCID:0000000183154344)↗

Demonstration of a Balloon Borne Arc-Second Pointer Design

Many designs for utilizing stratospheric balloons as low-cost platforms on which to conduct space science experiments have been proposed throughout the years. A major hurdle in extending the range of experiments for which these vehicles are useful has been the imposition of the gondola dynamics on the accuracy with which an instrument can be kept pointed at a celestial target. A significant number of scientists have sought the ability to point their instruments with jitter in the arc-second range. This paper presents the design and analysis of a stratospheric balloon borne pointing system that is able to meet this requirement. The test results of a demonstration prototype of the design with similar ability are also presented. Discussion of a high fidelity controller simulation for design analysis is presented. The flexibility of the flight train is represented through generalized modal analysis. A multiple controller scheme is utilized for coarse and fine pointing. Coarse azimuth pointing is accomplished by an established pointing system, with extensive flight history, residing above the gondola structure. A pitch-yaw gimbal mount is used for fine pointing, providing orthogonal axes when nominally on target. Fine pointing actuation is from direct drive dc motors, eliminating backlash problems. An analysis of friction nonlinearities and a demonstration of the necessity in eliminating static friction are provided. A unique bearing hub design is introduced that eliminates static friction from the system dynamics. A control scheme involving linear accelerometers for enhanced disturbance rejection is also presented. Results from a linear analysis of the total system and the high fidelity simulation are given. Results from a generalized demonstration prototype are presented. Commercial off-the-shelf (COTS) hardware was used to demonstrate the efficacy and performance of the pointer design for a mock instrument. Sub-arcsecond pointing ability from a ground hang test setup is shown from the testing results. This paper establishes that the proposed control strategy can be made robustly stable with significant design margins. Also demonstrated is the efficacy of the proposed system in rejecting disturbances larger than those considered realistic. The system is implemented and demonstrates sub arc second pointing ability using COTS hardware. Finally, we see that sub arc-second pointing stability can be achieved for a large instrument pointing at an inertial target.

DeWeese, Keith D.↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

Impacts of WRF Physics and Measurement Uncertainty on California Wintertime Model Wet Bias

The Weather and Research Forecast (WRF) model version 3.0.1 is used to explore California wintertime model wet bias. In this study, two wintertime storms are selected from each of four major types of large-scale conditions; Pineapple Express, El Nino, La Nina, and synoptic cyclones. We test the impacts of several model configurations on precipitation bias through comparison with three sets of gridded surface observations; one from the National Oceanographic and Atmospheric Administration, and two variations from the University of Washington (without and with long-term trend adjustment; UW1 and UW2, respectively). To simplify validation, California is divided into 4 regions (Coast, Central Valley, Mountains, and Southern California). Simulations are driven by North American Regional Reanalysis data to minimize large-scale forcing error. Control simulations are conducted with 12-km grid spacing (low resolution) but additional experiments are performed at 2-km (high) resolution to evaluate the robustness of microphysics and cumulus parameterizations to resolution changes. We find that the choice of validation dataset has a significant impact on the model wet bias, and the forecast skill of model precipitation depends strongly on geographic location and storm type. Simulations with right physics options agree better with UW1 observations. In 12-km resolution simulations, the Lin microphysics and the Kain-Fritsch cumulus scheme have better forecast skill in the coastal region while Goddard, Thompson, and Morrison microphysics, and the Grell-Devenyi cumulus scheme perform better in the rest of California. The effect of planetary boundary layer, soil-layer, and radiation physics on model precipitation is weaker than that of microphysics and cumulus processes for short- to medium-range low-resolution simulations. Comparison of 2-km and 12-km resolution runs suggests a need for improvement of cumulus schemes, and supports the use of microphysics schemes in coarser-grid applications.

54 ENVIRONMENTAL SCIENCES↗

Simulation study of the operational effects of fuel-conservative approaches

Fuel-conservative procedures have been investigated using real-time air traffic control simulations linked to two piloted simulators. The fuel-conservative procedures studied were profile descents and two types of landing approaches, delayed flap and IATA. The investigation determined the effect of these procedures on the ATC system operation. It examined the mixing of aircraft executing fuel-conservative approaches with those executing conventional approaches. The most difficult approach type mix of traffic was found to be 50% conventional and 50% delayed flap. However, for the test scenario chosen, arrival rates of at least 30 aircraft per hour were feasible and resulted in a net average fuel saving, even for the most difficult mix. Also, there is a fuel savings and reduced controller workload for the profile descent procedures.

Tobias, L.↗