Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Rapid Assessment of Contaminants and Interferences in Mass Spectrometry Data Using Skyline

Proper sample preparation in proteomic workflows is essential to the success of modern mass spectrometry experiments. Complex workflows often require reagents which are incompatible with MS analysis (e.g., detergents) necessitating a variety of sample cleanup procedures. Efforts to understand and mitigate sample contamination are a continual source of disruption with respect to both time and resources. To improve the ability to rapidly assess sample contamination from a diverse array of sources, I developed a molecular library in Skyline for rapid extraction of contaminant precursor signals using MS1 filtering. This contaminant template library is easily managed and can be modified for a diverse array of mass spectrometry sample preparation workflows. Utilization of this template allows rapid assessment of sample integrity and indicates potential sources of contamination. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acetonitrile contamination in the cathode of proton exchange membrane fuel cells and cell performance recovery

Acetonitrile contamination in an operating cell and performance recovery are investigated in detail by a series of electrochemical characterizations, including constant current operation, electrochemical impedance spectroscopy, cyclic voltammetry, linear scanning voltammetry and chronoamperometry. We demonstrate that 20 ppm of acetonitrile in the air stream causes an approximate 40% reduction in cell performance at 1 A cm -2 ; however, the neat air operation completely restores the single cell. Cell performance degradation and recovery display two distinguishable periods that correspond to the effect of catalyst activity and electrolyte proton conductivity, respectively. The potential effect on acetonitrile contamination is also studied in a non-operating H 2 /N 2 cell. The results indicate that low and high potentials cause a larger proton conductivity effect than a medium potential. Two recovery methods were conducted to restore cell performance after contamination in N 2 at different potentials. The neat air operation completely mitigated the poisoning effect in approximately 5 h regardless of contamination history; however, the N 2 purge and subsequent potential scans, even scanning up to 1.5 V vs hydrogen reference electrode, did not affect the poisoned cell. The liquid water generated in catalyst layers may play an important role during the recovery from acetonitrile contamination in a proton exchange membrane fuel cell.

25 ENERGY STORAGE↗

Influence of surface contamination on the wettability of heat transfer surfaces

In this study, the wettability of heat transfer surfaces plays an important role in liquid–vapor phase change phenomena, including boiling incipience, the critical heat flux, the Leidenfrost transition, and condensation. The influence of adsorbed surface contamination at the nanoscale, though seldom considered, can have a profound impact on wetting behavior. This study quantitatively investigates the impact of contaminant layer thickness on wettability. Various cleaning treatments are explored on zirconium and 6061 aluminum to determine the effect on contaminant and oxide layer thickness. Angle-resolved X-ray photoelectron spectroscopy can be used to measure the thickness of oxide and contaminant layers, which is then correlated to wettability by measuring the equilibrium contact angle. Results indicate that even after solvent cleaning, the contact angle of water on practical heat transfer surfaces is dominated by a hydrocarbon contaminant overlayer around five nanometers thick.

36 MATERIALS SCIENCE↗

Geophysical signatures of soil AFFF contamination from spectral induced polarization and low field nuclear magnetic resonance methods

Few field methods are available for characterizing source zones contaminated with aqueous film forming foam (AFFF). Non-invasive geophysical characterization of AFFF source zone contamination in situ could assist with the delineation and characterization of these sites, allowing for more informed sampling regimes aimed at quantifying subsurface poly- and perfluoroalkyl substances (PFAS) contamination. In this study, we present initial results from the investigation of the sensitivity of two existing surface and borehole-deployable geophysical technologies, spectral induced polarization (SIP), and low field nuclear magnetic resonance (NMR), to soils impacted with AFFF. To investigate the sensitivity of these methods to AFFF-impacted soil, bench-scale column experiments were conducted on samples consisting of natural and synthetic soils and groundwater. While our findings do not show strong evidence of NMR sensitivity to soil PFAS contamination, we do find evidence that SIP has sufficient sensitivity to detect PFAS sorption to soils. This finding is based on evidence that AFFF constituents associated with the pore surface produce a measurable polarization response in both freshly contaminated synthetic soils and in soils historically impacted with AFFF.

54 ENVIRONMENTAL SCIENCES↗

Comparison of potential drinking water source contamination across one hundred U.S. cities

Abstract Drinking water supplies of cities are exposed to potential contamination arising from land use and other anthropogenic activities in local and distal source watersheds. Because water quality sampling surveys are often piecemeal, regionally inconsistent, and incomplete with respect to unregulated contaminants, the United States lacks a detailed comparison of potential source water contamination across all of its large cities. Here we combine national-scale geospatial datasets with hydrologic simulations to compute two metrics representing potential contamination of water supplies from point and nonpoint sources for over a hundred U.S. cities. We reveal enormous diversity in anthropogenic activities across watersheds with corresponding disparities in the potential contamination of drinking water supplies to cities. Approximately 5% of large cities rely on water that is composed primarily of runoff from non-pristine lands (e.g., agriculture, residential, industrial), while four-fifths of all large cities that withdraw surface water are exposed to treated wastewater in their supplies.

54 ENVIRONMENTAL SCIENCES↗

Influence of base pressure and atmospheric contaminants on a-Si:H solar cell properties

The influence of atmospheric contaminants oxygen and nitrogen on the performance of thin-film hydrogenated amorphous silicon (a-Si:H) solar cells grown by plasma-enhanced chemical vapor deposition at 13.56 MHz was systematically investigated. The question is addressed as to what degree of high base pressures (up to 10{sup -4} Torr) are compatible with the preparation of good quality amorphous silicon based solar cells. The data show that for the intrinsic a-Si:H absorber layer exists critical oxygen and nitrogen contamination levels (about 2x10{sup 19} atoms/cm{sup 3} and 4x10{sup 18} atoms/cm{sup 3}, respectively). These levels define the minimum impurity concentration that causes a deterioration in solar cell performance. This critical concentration is found to depend little on the applied deposition regime. By enhancing, for example, the flow of process gases, a higher base pressure (and leak rate) can be tolerated before reaching the critical contamination level. The electrical properties of the corresponding films show that increasing oxygen and nitrogen contamination results in an increase in dark conductivity and photoconductivity, while activation energy and photosensitivity are decreased. These effects are attributed to nitrogen and oxygen induced donor states, which cause a shift of the Fermi level toward the conduction band and presumably deteriorate the built-in electric field in the solar cells. Higher doping efficiencies are observed for nitrogen compared to oxygen. Alloying effects (formation of SiO{sub x}) are observed for oxygen contaminations above 10{sup 20} atoms/cm{sup 3}, leading to an increase in the band gap.

36 MATERIALS SCIENCE↗

Dynamic measurements of ultraviolet-enhanced silica contamination by photoluminescence-based diagnostic

The ultraviolet-enhanced (UV-enhanced) contamination of optical components leads to an untimely aging of sealed laser systems, photolithography, and synchrotron installations. The laser-induced deposition of organic films on silica substrates and coatings significantly reduces their transmission and degrades their optical functions. In this paper, measurements of organic contaminant films growth under 213 nm laser irradiation performed on silica Corning 7980 grade ArF are reported. We present an in situ contaminant layer growth diagnostic based on silica photoluminescence measurements. The purpose was to determine the photodeposition kinetics as a function of controlled environmental conditions and fluence and to find out the experimental conditions in which the growth of contamination films was significantly reduced. We then demonstrated that with a low partial pressure of oxygen, the growth of carbonaceous films is drastically reduced during UV laser irradiation whereas with water and nitrogen it was not the case. We also proposed a physical modeling of the UV-enhanced silica contamination processes.

36 MATERIALS SCIENCE↗

Use of Source Term and Air Dispersion Modeling in Planning Demolition of Highly Alpha-Contaminated Buildings

The current cleanup of structures related to cold-war production of nuclear materials includes the need to demolish a number of highly alpha-contaminated structures. The process of planning for the demolition of such structures includes unique challenges related to ensuring the protection of both workers and the public. Pre-demolition modeling analyses were conducted to evaluate potential exposures resulting from the proposed demolition of a number of these structures. Estimated emission rates of transuranic materials during demolition are used as input to an air-dispersion model. The climatological frequencies of occurrence of peak air and surface exposures at locations of interest are estimated based on years of hourly meteorological records. The modeling results indicate that downwind deposition is the main operational limitation for demolition of a highly alpha-contaminated building. The pre-demolition modeling directed the need for better contamination characterization and/or different demolition methods—and in the end, provided a basis for proceeding with the planned demolition activities. Post-demolition modeling was also conducted for several contaminated structures, based on the actual demolition schedule and conditions. Comparisons of modeled and monitoring results are shown. Recent monitoring data from the demolition of a UO3 plant shows increments in concentrations that were previously identified in the pre-demolition modeling predictions; these comparisons confirm the validity and value of the pre-demolition source-term and air dispersion computations for planning demolition activities for other buildings with high levels of radioactive contamination.

air exposure↗

SU-E-T-238: Deriving Electron Contamination Spectra From Pure and Clinical Photon Beams

Purpose: To extract the electron contamination energy spectra for an Elekta Precise Linac, based on pure photon and measured clinical beam percentage depth dose data. And to include this as an additional source in isource 4 in DOSXYZnrc. Methods: A pure photon beam was simulated for the Linac using isource 4 in the DOSXYZnrc Monte Carlo (MC) code. Percentage depth dose (PDD) data were extracted afterwards for a range of field sizes (FS). These simulated dose data were compared to actual measured dose PDD data, with the data normalized at 10 cm depth. The resulting PDD data resembled the electron contamination depth dose. Since the dose fall-off is a strictly decreasing function, a method was adopted to derive the contamination electron spectrum. Afterwards this spectrum was used in a DOSXYZnrc MC simulation run to verify that the original electron depth dose could be replicated. Results: Various square aperture FS’s for 6, 8 and 15 megavolt (MV) photon beams were modeled, simulated and compared to their respective actual measured PDD data. As FS increased, simulated pure photon depth-dose profiles shifted deeper, thus requiring electron contamination to increase the surface dose. The percentage of electron weight increased with increase in FS. For a FS of 15×15 cm{sup 2}, the percentage electron weight is 0.1%, 0.2% and 0.4% for 6, 8 and 15 MV beams respectively. Conclusion: From the PDD results obtained, an additional electron contamination source was added to the photon source model so that simulation and measured PDD data could match within 2 % / 2 mm gamma-index criteria. The improved source model could assure more accurate simulations of surface doses. This research project was funded by the South African Medical Research Council (MRC) with funds from National Treasury under its Economic Competitiveness and Support package.

60 APPLIED LIFE SCIENCES↗

Isotopic Studies of Contaminant Transport at the Hanford Site, Washington.

Processes of fluid flow and chemical transport through the vadose zone can be characterized through the isotopic systematics of natural soils, minerals, pore fluids and groundwater. In this contribution, we first review our research using measured isotopic variations, due both to natural and site related processes, of the elements H, O, N, Sr and U, to study the interconnection between vadose zone and groundwater contamination at the Hanford Site in south-central Washington. We follow this brief review with a presentation of new data pertaining to vadose zone and groundwater contamination in the WMA T-TX-TY vicinity. Uranium (U) isotopic data for the C3832 core (WMA TX) indicates the involvement of processed natural U fuel, and links the observed U contamination to the nearby single shelled tank TX-104. The data also precludes contamination from an early 1970’s TX-107 leak. In the case of the C4104 core (WMA T), the U isotopic data indicates a mixture of processed natural and enriched U fuels consistent with the major leak from T-106 in 1973. Uranium and Strontium isotopic data for the cores also provides direct evidence for chemical interaction between high-pH waste fluid and sediment. Isotopic data for groundwater nitrate contamination in the vicinity of WMA-T strongly suggests high-level tank waste (most likely from T-106) as the source of very high 99Tc concentrations recently observed at the NE corner of WMAT.

54 ENVIRONMENTAL SCIENCES↗

Coupling Sorption to Soil Weathering During Reactive Transport: Impacts of Mineral Transformation and Sorbent Aging on Contaminant Speciation and Mobility

This project aimed for a predictive-mechanistic understanding of the coupling between mineral weathering and contaminant (Cs, Sr, I) transport/fate in caustic waste-impacted sediments. Based on our prior studies of model clay mineral systems, we postulated that contaminant uptake to Hanford sediments would reflect concurrent adsorption and co-precipitation effects. Our specific objectives were: (1) to assess the molecular-scale mechanisms responsible for time-dependent sequestration of contaminants (Cs, Sr and I) during penetration of waste-induced weathering fronts; (2) to determine the rate and extent of contaminant release from the sorbed state; (3) to develop a reactive transport model based on molecular mechanisms and macroscopic flow experiments [(1) and (2)] that simulates adsorption, aging, and desorption dynamics. Progress toward achieving each of these objectives is discussed below. We observed unique molecular mechanisms for sequestration of Sr, Cs and I during native silicate weathering in caustic waste. Product solids, which included poorly crystalline aluminosilicates and well-crystallized zeolites and feldspathoids, accumulate contaminant species during crystal growth.

54 ENVIRONMENTAL SCIENCES↗

Geochemical Characterization of Chromate Contamination in the 100 Area Vadose Zone at the Hanford Site - Part 2

At the Hanford Site, chromate was used throughout the 100 Areas (100-B, 100-C, 100-D/DR, 100-F, 100-H, and 100 K) as a corrosion inhibitor in reactor cooling water. Chromate was delivered in rail cars, tanker trucks, barrels, and local pipelines as dichromate granular solid or stock solution. In many occasions, chromate was inevitably discharged to surface or near-surface ground through spills during handling, pipeline leaks, or during disposal to cribs. The composition of the liquids that were discharged is not known and it is quite possible that Cr(VI) fate and transport in the contaminated sediments would be a function of the chemical composition of the waste fluids. The major objectives of this investigation which was limited in scope by the financial resources available, were to 1) determine the leaching characteristics of hexavalent chromium [Cr(VI)] from contaminated sediments collected from 100-D Area spill sites; 2) elucidate possible Cr(VI) mineral and/or chemical associations that may be responsible for Cr(VI) retention in the Hanford Site 100 Areas through the use of macroscopic leaching studies, and microscale characterization of contaminated sediments; and 3) provide information to construct a conceptual model of Cr(VI) geochemistry in the Hanford 100 Area vadose zone that can be used for developing options for environmental remediation. The information gathered from this research effort will help to further improve our understanding of Cr(VI) behavior in the vadose zone and will also help in accelerating the 100 Area Columbia River Corridor cleanup by providing valuable information to develop remedial action based on a fundamental understanding of Cr(VI) vadose zone geochemistry. A series of column experiments were conducted with contaminated sediments to study Cr(VI) desorption patterns. Column experiments used the field size fraction of the sediment samples and a simulated Hanford Site groundwater solution. Periodic stop flow events were applied to evaluate the change in elemental concentration during time periods of no flow and greater fluid residence time. Sediments were characterized for the spatial and mineralogical associations of the contamination using some microscale techniques such as X-ray diffraction, scanning electron microscopy, energy dispersive spectroscopy, X-ray photoelectron spectroscopy, and Mössbauer spectroscopy.

54 ENVIRONMENTAL SCIENCES↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2018

Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) as a result of storm runoff. This activity supports U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collects air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters are recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station are also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2018. During the FY2018 reporting period, the warmest months were June, July, and August and the coldest were December through March. Solar radiation showed the same seasonal trend. Monthly mean wind speeds were highest in the spring (March through May) and early summer (June). Winds were generally from the west during the summer and from the north throughout the fall and winter. The monthly average relative humidity ranged from the mid-teens to approximately 50 percent. Humidity was lowest in the fall and highest in the winter. Monthly total precipitation ranged from 0 in October, December, and June to approximately 1.38 inches (in) (35.05 millimeters [mm]) in July. Total precipitation for FY2018 was 3.86 in (98.04 mm). During the reporting period, two runoff events were recorded at the flume. One occurred on July 14, 2018, in response to precipitation earlier the same day. This event produced a peak water depth of 11.26 in (28.60 centimeters [cm]) in the flume, which is equivalent to a discharge of 1.86 cubic feet per second (cfs) (0.05 cubic meters per second [cm/s]) and a velocity of 3.97 feet per second (fps) (1.21 meters per second [m/s]) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 1.29 fps (0.39 m/s), which is sufficient to transport silts and fine sands. The second flow event occurred in response to earlier precipitation on September 4, 2018. This event produced a peak water depth of 0.78 in (1.98 cm) in the flume, which is equivalent to a discharge of 0.03 cfs (0.001 cm/s) and a velocity of 1.17 fps (0.36 m/s) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 0.03 fps (0.01 m/s). Although neither runoff event produced sufficient flow velocities through the natural channel to cause local erosion and transport of coarser bedload materials, the velocity of the first runoff event was sufficient to transport silts and fine sands, which have been shown to be preferentially associated with radionuclide contaminants. Therefore, a sampling event was planned after the first flow event in conjunction with a periodic maintenance inspection. As no suspended load sampling is available at this location, bedload samples were collected from the vicinity of the flume on August 7, 2018. The collected sediment was separated into three particle size fractions and each fraction was analyzed for americium-241 (Am-241), plutonium-238 (Pu-238), and plutonium-239/240 (Pu-239/240) by alpha spectrometry. The two smaller particle size fractions had higher concentrations of all three radionuclides than the largest particle size fraction. Additionally, Pu-239/240 had the highest concentration and Pu-238 had the lowest concentration in all samples. The same relationship between the concentrations of Pu-238 and Pu-239/240 was seen in samples reported in FY2013 and FY2014. Observation of meteorological and environmental conditions that lead to storm runoff will help identify parameters and threshold conditions that should be incorporated into postclosure monitoring plans for this and similar sites as well as aid in determining appropriate closure strategies for other Soils CAUs.

54 ENVIRONMENTAL SCIENCES↗

Conceptual Models for Migration of Key Groundwater Contaminants Through the Vadose Zone and Into the Upper Unconfined Aquifer Below the B-Complex

The B-Complex contains 3 major crib and trench disposal sites and 3 SST farms that have released nearly 346 mega-liters of waste liquids containing the following high groundwater risk drivers: ~14,000 kg of CN, 29,000 kg of Cr, 12,000 kg of U and 145 Ci of Tc-99. After a thorough review of available vadose zone sediment and pore water, groundwater plume, field gamma logging, field electrical resistivity studies, we developed conceptual models for which facilities have been the significant sources of the contaminants in the groundwater and estimated the masses of these contaminants remaining in the vadose zone and currently present in the groundwater in comparison to the totals released. This allowed us to make mass balance calculations on how consistent our knowledge is on the current deep vadose zone and groundwater distribution of contaminants. Strengths and weaknesses of the conceptual models are discussed as well as implications on future groundwater and deep vadose zone remediation alternatives. Our hypothesized conceptual models attribute the source of all of the cyanide and most of the Tc-99 currently in the groundwater to the BY cribs. The source of the uranium is the BX-102 tank overfill event and the source of most of the chromium is the B-7-A&B and B-8 cribs. Our mass balance estimates suggest that there are much larger masses of U, CN, and Tc remaining in the deep vadose zone within ~20 ft of the water table than is currently in the groundwater plumes below the B-Complex. This hypothesis needs to be carefully considered before future remediation efforts are chosen. The masses of these groundwater risk drivers in the the groundwater plumes have been increasing over the last decade and the groundwater plumes are migrating to the northwest towards the Gable Gap. The groundwater flow rate appears to flucuate in response to seasonal changes in hydraulic gradient. The flux of contaminants out of the deep vadose zone from the three proposed sources also appears to be transient such that the evolution of the contaminant plumes is transient.

54 ENVIRONMENTAL SCIENCES↗

Reactant Carrier Microfoam Technology for In-Situ Remediation of Radionuclide and Metallic Contaminants in Deep Vadose Zone

The U.S. Department of Energy (DOE) is currently developing advanced remedial technologies for addressing metal and radionuclide (Cr, Tc, and U) contamination in deep vadose zone environments. One of the transformational technology alternatives being considered by the DOE Office of Environmental Management, is the use of Reactant Carrier Microfoams (RCM) as a minimally invasive method for delivery and emplacement of reagents for in-situ immobilization of contaminants. Penetration of low permeability zones deep within the subsurface for Enhance Oil Recovery (EOR) has been well-established. Use of surfactant foams have also been explored for mobilizing DNAPL from sediments. So far, the concept of using RCM for immobilizing labile metal and long-lived radionuclide contaminants in the deep vadose zone has not been explored. We, at the Pacific Northwest National Laboratory (PNNL), conducted studies to develop stable foams as a means to deliver reductive and/or precipitating reactants to the deep subsurface. To test the feasibility of this approach, we developed a preliminary foam formulation consisting of a mixture of an anionic and a nonionic surfactant with a reactant consisting of a 9:1 blend of tripoly- and orthophosphate. The MSE Technology Applications, Inc (MSE) in collaboration with PNNL, conducted a scale-up test to evaluate the efficacy of this reactant carrier foam for in-situ immobilization of U containing sediment zones in a heterogenous sediment matrix. The data indicated that successful immobilization of U contamination is feasible using specifically tailored reactant carrier foam injection technology. Studies are continuing for developing more robust optimized RCM for highly mobile contaminants such as Cr (VI), Tc (VII) in the deep vadose zone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Denitrifying bacteria from the genus Rhodanobacter dominate bacterial communities in the highly contaminated subsurface of a nuclear legacy waste site

The effect of long-term mixed-waste contamination, particularly uranium and nitrate, on the microbial community in the terrestrial subsurface was investigated at the field scale at the Oak Ridge Integrated Field Research Challenge (ORIFRC) site in Oak Ridge, TN. The abundance, community composition, and distribution of groundwater microorganisms were examined across the site during two seasonal sampling events. At representative locations, subsurface sediment was also examined from two boreholes, one sampled from the most heavily contaminated area of the site and another from an area with low contamination. A suite of DNA- and RNA-based molecular tools were employed for community characterization, including quantitative PCR of ribosomal RNA and nitrite reductase genes, community composition fingerprinting analysis, and high-throughput pyrotag sequencing of rRNA genes. The results demonstrate that pH is a major driver of the subsurface microbial community structure, and denitrifying bacteria from the genus Rhodanobacter (class Gammaproteobacteria) dominate at low pH. The relative abundance of bacteria from this genus was positively correlated with lower pH conditions, and these bacteria were abundant and active in the most highly contaminated areas. Other factors, such as concentration of nitrogen species, oxygen and sampling season did not appear to strongly influence the distribution of Rhodanobacter. Results indicate that these organisms are acid-tolerant denitrifiers, well suited to the acidic, nitrate-rich subsurface conditions, and pH is confirmed as a dominant driver of bacterial community structure in this contaminated subsurface environment.

54 ENVIRONMENTAL SCIENCES↗

Source and Fate of Inorganic Soil Contamination Around the Abandoned Phillips Sulfide Mine Hudson Highlands New York

The abandoned Phillips sulfide mine in the critical Highlands watershed in New York has been shown to produce strongly acidic mine drainage (AMD) with anomalous metal contaminants in first-order streams that exceeded local water standards by up to several orders of magnitude (Gilchrist et al., 2009). The metal-sulfide-rich tailings also produce contaminated soils with pH < 4, organic matter < 2.5% and trace metals sequestered in soil oxides. A geochemical transect to test worst-case soil contamination showed that Cr, Co and Ni correlated positively with Mn, (r = 0.72, r = 0.89, r = 0.80, respectively), suggesting Mn-oxide sequestration and that Cu and Pb correlated with Fe (r = 0.76, r = 0.83, respectively), suggesting sequestration in goethite. Ubiquitous, yellow coating on the mine wastes, including jarosite and goethite, is a carrier of the metals. Geochemical and {mu}-SXRF analyses determined Cu to be the major soil contaminant, {mu}-SXRF also demonstrated that the heterogeneous nature of the soil chemistry at the micro-meter scale is self-similar to those in the bulk soil samples. Generally metals decreased, with some fluctuations, rapidly downslope through suspension of fines and dissolution in AMD leaving the area of substantial contamination << 0.5 km from the source.

54 ENVIRONMENTAL SCIENCES↗

Subsoil contaminant Cr fate and transport: The complex reality of the Hanford subsurface

Chromium-contaminated subsurface sites are common throughout the globe. In this chapter the discussion will be focused on one Cr-contaminated, i.e., Hanford site, WA, USA. The chapter summarizes the work conducted at this site to study contaminant Cr6+ fate and behavior under conditions imposed by different waste chemistries ranging from acidic to hyperalkaline. The objectives of this chapter are to present an overview of different aspects of Cr interaction with minerals; present evidence of similar and contrasting Cr6+ reactions, processes and attenuation mechanisms operating in subsurface environments under different conditions imposed by acidic, neutral and alkaline waste liquids; provide inputs to conceptual Cr geochemical models (either site specific or general and suitable for many contaminated sites); present ideas on potential remedial measures. The insights presented and discussed in this chapter should be useful for other Cr contaminated sites across the world.

Hanford subsurface↗