Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONSULTANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Assessing the Value of an Optional Radiation Oncology Clinical Rotation During the Core Clerkships in Medical School

Purpose: Few medical students are given proper clinical training in oncology, much less radiation oncology. We attempted to assess the value of adding a radiation oncology clinical rotation to the medical school curriculum. Methods and Materials: In July 2010, Jefferson Medical College began to offer a 3-week radiation oncology rotation as an elective course for third-year medical students during the core surgical clerkship. During 2010 to 2012, 52 medical students chose to enroll in this rotation. The rotation included outpatient clinics, inpatient consults, didactic sessions, and case-based presentations by the students. Tests of students' knowledge of radiation oncology were administered anonymously before and after the rotation to evaluate the educational effectiveness of the rotation. Students and radiation oncology faculty were given surveys to assess feedback about the rotation. Results: The students' prerotation test scores had an average of 64% (95% confidence interval [CI], 61-66%). The postrotation test scores improved to an average of 82% (95% CI, 80-83%; 18% absolute improvement). In examination question analysis, scores improved in clinical oncology from 63% to 79%, in radiobiology from 70% to 77%, and in medical physics from 62% to 88%. Improvements in all sections but radiobiology were statistically significant. Students rated the usefulness of the rotation as 8.1 (scale 1-9; 95% CI, 7.3-9.0), their understanding of radiation oncology as a result of the rotation as 8.8 (95% CI, 8.5-9.1), and their recommendation of the rotation to a classmate as 8.2 (95% CI, 7.6-9.0). Conclusions: Integrating a radiation oncology clinical rotation into the medical school curriculum improves student knowledge of radiation oncology, including aspects of clinical oncology, radiobiology, and medical physics. The rotation is appreciated by both students and faculty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

18F-fluorodeoxyglucose Positron Emisson Tomography/Computed Tomography Guided Conformal Brachytherapy for Cervical Cancer

Purpose: To evaluate the feasibility of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT)-guided conformal brachytherapy treatment planning in patients with cervical cancer. Methods and Materials: Pretreatment FDG-PET/CT was performed for 12 patients with cervical cancer. Brachytherapy simulation was performed after an external-beam radiation therapy median dose of 4140 cGy. Patients underwent FDG-PET/CT scans with placement of tandem and ovoid applicators. The gross tumor volume (GTV) was determined by adjusting the window and level to a reasonable value and outlining the edge of the enhancing area, which was done in consultation with a nuclear medicine physician. A standardized uptake value profile of the tumor margin was taken for each patient relative to the maximum uptake value of each tumor and analyzed. The plan was designed to deliver 400 cGy to point A (point A plan) or to cover the clinical target volume (CTV) (PET/CT plan). Results: The median dose that encompassed 95% of the target volume (D95) of the CTV was 323.0 cGy for the point A plan vs 399.0 cGy for the PET/CT plan (P=.001). The maximum standardized uptake values (SUV{sub max}) of the tumors were reduced by a median of 57% (range, 13%-80%). All but 1 patient presented with discernable residual uptake within the tumors. The median value of the thresholds of the tumors contoured by simple visual analysis was 41% (range, 23%-71%). Conclusions: In this study, the PET/CT plan was better than the conventional point A plan in terms of target coverage without increasing the dose to the normal tissue, making optimized 3-dimensional brachytherapy treatment planning possible. In comparison with the previously reported study with PET or CT alone, we found that visual target localization was facilitated by PET fusion on indeterminate CT masses. Further studies are needed to characterize the metabolic activity detected during radiation therapy for more reliable targeting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Contouring Variability on Dosimetric Parameters for Brain Metastases Treated With Stereotactic Radiosurgery

Purpose: To quantify the effect of contouring variation on stereotactic radiosurgery plan quality metrics for brain metastases. Methods and Materials: Fourteen metastases, each contoured by 8 physicians, formed the basis of this study. A template-based dynamic conformal 5-arc dose distribution was developed for each of the 112 contours, and each dose distribution was applied to the 7 other contours in each patient set. Radiation Therapy Oncology Group (RTOG) plan quality metrics and the Paddick conformity index were calculated for each of the 896 combinations of dose distributions and contours. Results: The ratio of largest to smallest contour volume for each metastasis varied from 1.25 to 4.47, with a median value of 1.68 (n=8). The median absolute difference in RTOG conformity index between the value for the reference contour and the values for the alternative contours was 0.35. The variation of the range of conformity index for all contours for a given tumor varied with the tumor size. Conclusions: The high degree of interobserver contouring variation strongly suggests that peer review or consultation should be adopted to standardize tumor volume prescription. Observer confidence was not reflected in contouring consistency. The impact of contouring variability on plan quality metrics, used as criteria for clinical trial protocol compliance, was such that the category of compliance was robust to interobserver effects only 70% of the time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Study of {sup 18}FDG-PET With CT Coregistration for Radiation Treatment Planning of Lymphomas and Other Hematologic Malignancies

Purpose: This prospective single-institution study examined the impact of positron emission tomography (PET) with the use of 2-[{sup 18}F] fluoro-2-deoxyglucose and computed tomography (CT) scan radiation treatment planning (TP) on target volume definition in lymphoma. Methods and Materials: 118 patients underwent PET/CT TP during June 2007 to May 2009. Gross tumor volume (GTV) was contoured on CT-only and PET/CT studies by radiation oncologists (ROs) and nuclear medicine physicians (NMPs) for 95 patients with positive PET scans. Treatment plans and dose-volume histograms were generated for CT-only and PET/CT for 95 evaluable sites. Paired t test statistics and Pearson correlation coefficients were used for analysis. Results: 70 (74%) patients had non-Hodgkin lymphoma, 10 (11%) had Hodgkin lymphoma, 12 (10%) had plasma-cell neoplasm, and 3 (3%) had other hematologic malignancies. Forty-three (45%) presented with relapsed/refractory disease. Forty-five (47%) received no prior chemotherapy. The addition of PET increased GTV as defined by ROs in 38 patients (median, 27%; range, 5%-70%) and decreased GTV in 41 (median, 39.5%; range, 5%-80%). The addition of PET increased GTV as defined by NMPs in 27 patients (median, 26.5%; range, 5%-95%) and decreased GTV in 52 (median, 70%; range, 5%-99%). The intraobserver correlation between CT-GTV and PET-GTV was higher for ROs than for NMPs (0.94, P<.01 vs 0.89, P<.01). On the basis of Bland-Altman plots, the PET-GTVs defined by ROs were larger than those defined by NMPs. On evaluation of clinical TPs, only 4 (4%) patients had inadequate target coverage (D95 <95%) of the PET-GTV defined by NMPs. Conclusions: Significant differences between the RO and NMP volumes were identified when PET was coregistered to CT for radiation planning. Despite this, the PET-GTV defined by ROs and NMPs received acceptable prescription dose in nearly all patients. However, given the potential for a marginal miss, consultation with an experienced PET reader is highly encouraged when PET/CT volumes are delineated, particularly for questionable lesions and to assure complete and accurate target volume coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considerations for Observational Research Using Large Data Sets in Radiation Oncology

The radiation oncology community has witnessed growing interest in observational research conducted using large-scale data sources such as registries and claims-based data sets. With the growing emphasis on observational analyses in health care, the radiation oncology community must possess a sophisticated understanding of the methodological considerations of such studies in order to evaluate evidence appropriately to guide practice and policy. Because observational research has unique features that distinguish it from clinical trials and other forms of traditional radiation oncology research, the International Journal of Radiation Oncology, Biology, Physics assembled a panel of experts in health services research to provide a concise and well-referenced review, intended to be informative for the lay reader, as well as for scholars who wish to embark on such research without prior experience. This review begins by discussing the types of research questions relevant to radiation oncology that large-scale databases may help illuminate. It then describes major potential data sources for such endeavors, including information regarding access and insights regarding the strengths and limitations of each. Finally, it provides guidance regarding the analytical challenges that observational studies must confront, along with discussion of the techniques that have been developed to help minimize the impact of certain common analytical issues in observational analysis. Features characterizing a well-designed observational study include clearly defined research questions, careful selection of an appropriate data source, consultation with investigators with relevant methodological expertise, inclusion of sensitivity analyses, caution not to overinterpret small but significant differences, and recognition of limitations when trying to evaluate causality. This review concludes that carefully designed and executed studies using observational data that possess these qualities hold substantial promise for advancing our understanding of many unanswered questions of importance to the field of radiation oncology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Patient Education Videos and Knowledge of Radiation Treatment

Patient knowledge of radiation therapy (RT) before consult is typically limited, with many having misconceptions or fears. There exists a need to improve patient education in RT. Our purpose was to study the impact of patient education videos on patient-reported knowledge of RT, anxiety/fear, and satisfaction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Oncology in the Land of the Pyramids: How Sudan Continues to Push the Frontiers of Cancer Care in Eastern Africa

When faced with illness, Sudanese patients have traditionally relied primarily on folklore healers. In the recent past, Sudan increased its health care spending and placed ever-greater importance on medical education. Although traditional remedies still play an important role, Sudanese patients increasingly consult conventional medicine. Not only infectious diseases but also a rising burden of noncommunicable conditions, including cancer, represent major health care challenges. Therefore, Sudan will need to make the best out of the limited resources available and further increase investment in health care to confront these trends successfully. Sudan was one of the first African countries to recognize the importance of radiation oncology in multidisciplinary cancer care and began investing in it in the 1960s. Today, there are 4 comprehensive cancer centers in the country, which offer radiation therapy and employ 10 radiation therapy machines for a population of about 45 million people. This proportion is an indication that Sudan still has an underfunded health care system with a lack of infrastructure and human resources. The present manuscript intends to provide a well-rounded overview of radiation oncology in Sudan today.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Access Palliative Radiation Therapy Clinics: The Evidence Is There, but Where Are the Clinics? An Australian and New Zealand Perspective

First developed in Canada in the 1990s, Rapid Access Palliative Radiation Therapy (RAPRT) clinics have subsequently spread internationally to expedite treatment for near end-of-life patients, sparing them the need for multiple visits to the department. A “classical” RAPRT clinic is herein defined as “a dedicated clinic specifically established to enable (ideally) same day consultation, planning for, and delivery of palliative radiation treatment.” The aim of this work was to determine the current status of these clinics in Australia and New Zealand (ANZ).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for the Safe Storage, Handling, and Disposal of Pyrophoric Liquids and Solids in the Laboratory

Due to the inherent nature of pyrophoric substances to ignite spontaneously upon exposure to air, special precautions must be taken to ensure their safe handling and use. Pyrophoric gases (such as diborane, dichloroborane, phosphine, etc.) are typically the easiest class of pyrophoric substances to handle since the gas can be plumbed directly to the application and used remotely. Pyrophoric solids and liquids, however, require the user to physically manipulate them when transferring them from one container to another. Failure to follow proper safety precautions could result in serious injury or unintended consequences to laboratory personnel.12 Because of this danger, pyrophorics should be handled only by experienced personnel. Users with limited experience must be trained on how to handle pyrophoric reagents and consult with a knowledgeable staff member prior to performing the experimental task. The purpose of this article is three fold: 1) to provide guidelines and general safety precautions to avoid accidents, 2) describe proper techniques on how to successfully handle, store, and dispose of pyrophoric liquids and solids, and 3) illustrate best practices for working with this class of reactants in a laboratory environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating commercial feasibility of a new tall wind tower design concept using a stochastic levelized cost of energy model

Wind power generation has seen a dramatic increase in the 21st century and the Department of Energy (DOE) envisions that wind energy will become a much larger part of overall power generation in the U.S. by 2050. Wind turbines have continued to grow in size during the last few decades with towers commonly built at a height of 80 m for typical utility-scale turbines in the Unites States, and this is accompanied by certain transportation and logistics challenges. The newly proposed tall tower technology has been designed to be cost-effective in assembling towers as high as 140 m from precast concrete module components that are capable of transport on the U.S. road system. This paper presents an alternative wind tower design with potential for reducing the overall levelized cost of energy (LCOE); it evaluates a hexagonal precast concrete wind tower solution that facilitates use of a taller wind turbine generator for harvesting stronger, steadier, and more frequent wind resources to increase wind energy production and lower the overall LCOE. An integrated team of industry experts was consulted to support development of a stochastic life cycle cost model using a parametric estimate of the cost and fabrication and assembly schedules of this new wind tower design concept as well as forecasting the projected revenue to be created by the new technology. The study concludes that this new design concept is a commercially viable solution, with an estimated LCOE savings ranging from 2% to 4% compared with the typical 80 m turbine deployed in the United States, and it also provides wind power potential to previously untapped regions in the country. This article helps to inform energy developers, manufacturers, and policy makers, both regionally and nationally, of a possible economically feasible wind tower design solution.

17 WIND ENERGY↗

Reducing the cost of home energy upgrades in the US: An industry survey

Decarbonizing the US residential building stock requires a substantial acceleration in home energy upgrades. Numerous barriers exist to accelerating adoption of efficient and electric building technologies, but foremost among these is high upfront costs. This study uses an industry survey delivered to a sample of home energy professionals to examine promising cost reduction strategies across a range of project types, including HVAC, water heating, and envelope/insulation projects. The survey included quantitative and qualitative questions to collect evidence on the estimated cost reduction potential of these strategies and their likelihood of use in the construction industry. The 167 survey respondents included contractors, energy consultants, architects, manufacturers, and others with experience in delivering energy upgrades in single-family and multifamily buildings in the US. Results show that significant cost reductions are achievable by minimizing additional infrastructure costs (such as replacing electric panels), streamlining project planning/management, and deploying innovations that simplify installation. We find that for a typical deep retrofit project, including heat pumps for space and water heating in addition to envelope upgrades, the strategies could result in a total installed cost reduction of nearly 50%, dramatically improving the customer economics of such a project. This research makes a novel contribution to the literature on strategies to reduce the costs of residential retrofits. We discuss how our study's insights on the highest-value cost reduction strategies for home energy upgrades can further accelerate their uptake in the US housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fabric controls on fracture surface roughness of an architected rock material

Fluid flow through fractures is intimately linked to the fracture surfaces that define the void geometry through which fluids flow. Thus, an understanding of what controls fracture surface roughness is essential to the development of models for predicting fluid transport through fractured rock. The difficulty in predicting surface roughness arises from the complexity of rock which is inherently heterogeneous and nonuniform in composition, fabric, and structural components, even when samples are acquired from the same rock mass. Here, a benchmarked-simulation approach motivated from geo-architected 3D printed synthetic gypsum rocks is used to provide insight into the competing contributions from fabric and layering on fracture roughness formation. Simulation results from a discrete element model (Particle Flow Code, Itasca Consulting Group, Inc.) clearly indicate that the relative orientation between mineral layers and in-layer mineral fabric, and the variability in mineral bonding strengths determine whether anisotropic corrugated surfaces or isotropic surfaces are formed. Weak mineral layers oriented perpendicular to the applied load resulted in strong roughness anisotropy. Peak failure loads were found to vary up to 30% depending on the strength of the mineral fabric at the location of fracture initiation, which provides insight into the observed high variability in strength values of natural rock. The uniqueness of induced fracture roughness and peak failure load is intimately linked to layering, mineral fabric, and their distribution in the rock. These findings have important implications for any architected material fabricated through serial printing of layers with local compositional heterogeneity.

3D printed rock↗

Developments of the EXFOR Database: Possible New Formats

The EXFOR database is a collection of experimental nuclear reaction data, maintained by the IAEA on behalf of the International Network of Nuclear Reaction Data Centres (NRDC). The format for the storage of such data was first described in 1969 and while there have been many incremental changes over the years so that the format is now capable of containing a very wide range of measurement results, there is a growing realisation that a major change is required. Consequently the IAEA Nuclear Data Section (NDS) organised a Consultant's Meeting on ‘Further Development of EXFOR’ in 2012. This was an opportunity for a range of international experts to discuss ways of improving EXFOR and while this focused on new formats there was also discussion on ways of storing new data, new output formats and software tools such as editors. This paper will discuss recent and proposed changes to enable new quantities to be stored (such as coincidence measurements and covariances), the range of output formats available (e.g. C4 and X4+) which make interaction with the data more user friendly and the possible use of XML to modernise the database.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 182

Nuclear spectroscopic information for known nuclides of mass number 182 (Yb,Lu,Hf,Ta,W,Re,Os,Ir,Pt,Au, Hg,Tl,Pb) with Z=70 to 82 and N=112 to 100 have been evaluated and presented together with adopted energies and Jπ of levels in these nuclei. No excited state data are yet available for {sup 182}Y and {sup 182}Lu, while only limited structure information is available for {sup 182}Pb and {sup 182}Tl. Rotational band structures are known for {sup 182}Hg and {sup 182}Au but spin–parity assignments remain largely tentative. The decays of {sup 182}Lu, {sup 182}Hg, {sup 182}Au and {sup 182}Tl are not well established. The {sup 182}Hf isotope is of geophysical and astrophysical interest. This evaluation supersedes previous full evaluations of A = 182 published by 2010Si13, 1988Fi05 and 1975Sc13, and a selected (mainly high–spin) update of A = 182 published by 1995Si04. Only the Adopted properties of levels and gamma rays are presented in NDS, consult the ENSDF database at (www.nndc.bnl.gov/ensdf/) for details of individual reaction and decay datasets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Structure and Decay Data for A=71 Isobars

Experimental nuclear spectroscopic data are evaluated for 12 known nuclides of mass number=71 (Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Kr). Detailed compiled and evaluated information is presented for each reaction and decay experiment. The β – n decay of 72 Co to 71 Ni is included in this work, while for β – n decay of 71 Co to 70 Ni, consult Nuclear Data Sheets for A=70 (2016Gu11) or the ENSDF database for 70 Ni. Combining all the available data, recommended values are provided for energies, spins and parities, and half-lives of levels, with energies, branching ratios and multipolarities of γ radiations, and characteristics of β and α radiations in radioactive decays. Excited-states have not yet been identified in 71 Mn, 71 Fe, and 71 Kr, with the ground-state half-life remaining unknown only for 71 Mn; data for excited states in 71 Co and 71 Ni are very limited; 71 Ga, 71 Ge and 71 As are the most extensively studied nuclides via various reactions and decays, followed by 71 Cu, 71 Zn, 71 Se, and 71 Br, however, except for 71 Ge, the decay schemes of all other nuclides are considered as incomplete due to a large gap between the decay Q-value and the highest observed level. Lastly, this work supersedes earlier evaluations of A=71 by 2011Ab01.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Structure and Decay Data for A=167 Isobars

Experimental nuclear spectroscopic data are compiled and evaluated for 17 known nuclides of mass 167 (Sm, Eu, Gd, Tb, Dy, Ho, Er Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt), 23 years after the previous full evaluation by 2000Ba65. Detailed information is presented for each reaction and decay experiment. Combining all the available data, recommended values are provided for energies, spins and parities, and half-lives of levels, with energies, branching ratios and multipolarities of γ radiations, and characteristics of β and α radiations in radioactive decays. Here, the α decays of A=171 nuclei to A=167 daughters are included in this work, while for α decays of A=167 nuclei to A=163 daughters, consult Nuclear Data Sheets (2010Re03) or the ENSDF database for A=163. 167 Er, 167 Tm, 167 Yb, 167 Lu and 167 Ta are among the most extensively studied nuclides via decay and high-spin gamma-ray spectroscopy measurements, followed by 167 Ho, 167 Hf, 167 W, and 167 Os. Information for excited states in 167 Dy, 167 Re, and 167 Ir are limited; no excited states have yet been identified in 167 Sm, 167 Eu, 167 Gd, 167 Tb and 167 Pt, with the ground-state half-life of 167 Sm remaining unknown. This work supersedes the earlier evaluation of A=167 nuclei by 2000Ba65.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electrodeposition of U and Pu on Thin C and Ti Substrates

Physics experiments aimed at deducing key parameters for use in a variety of programs critical to the mission of the National Laboratories require actinide targets placed onto various substrates. The target material quantity and the substrate desired depend upon the type of experiment being designed. The physicist(s) responsible for the experimental campaign will consult with the radiochemistry staff as to the feasibility of producing a desired target/substrate combination. In this report they discuss the production of U and Pu targets on very thin C and Ti substrates. The techniques used, plating cells designed for, tips, and limits is discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comments on extracting the resonance strength parameter from yield data

The F(α,n) reaction is the focus of on-going research in part because it is an important source of neutrons in the nuclear fuel cycle which can be exploited to assay nuclear materials, especially uranium in the form of UF 6 . At the present time there remains some considerable uncertainty (of the order of ± 20%) in the thick target integrated over angle (α,n) yield from 19 F (100% natural abundance) and its compounds as discussed. An important thin target cross-section measurement is that of Wrean and Kavanagh who explore the region from below threshold (2.36 MeV) to approximately 3.1 MeV with fine energy resolution. Integration of their cross-section data over the slowing down history of a stopping α-particle allows the thick target yield to be calculated for incident energies up to 3.1 MeV. This trend can then be combined with data from other sources to obtain a thick target yield curve over the wider range of interest to the fuel cycle (roughly threshold to 10 MeV to include all relevant α-emitters). To estimate the thickness of the CaF 2 target they used, Wrean and Kavanagh separately measured the integrated yield of the 6.129 MeV γ-rays from the resonance at 340.5 keV (laboratory α-particle kinetic energy) in the 19 F(p,αγ) reaction. To interpret the data they adopted a resonance strength parameter of (22.3 ± 0.8) eV based on a determination by Becker et al. The value and its uncertainty directly affects the thickness estimate and the extracted (α,n) cross-section values. In their citation to Becker et al's work, Wrean and Kavanagh comment that they did not make use of an alternative value of (23.7±1.0) eV reported by Croft because they were unable to reproduce the value from the data given in that paper. The value they calculated for the resonance strength from the thick target yield given by Croft was 21.4 eV. The purpose of this communication is to revisit the paper by Croft published in this journal and specifically to explain the origin of the reported resonance strength. Fortunately the original notes spanning the period 12 January 1988 to 16 January 1990 were available to consult. Finally, in hindsight there is certainly a case of excessive brevity to rectify. In essence the step requiring explanation is how to compute the resonance strength, ω γ , from the reported thick target resonance yield Y.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗