A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Skin-integrated stretchable actuators toward skin-compatible haptic feedback and closed-loop human-machine interactions

Abstract Skin-integrated haptic interfaces that can relay a wealth of information from the machine to the human are of great interest. However, existing haptic devices are not yet able to produce haptic cues that are compatible with the skin. In this work, we present the stretchable soft actuators for haptic feedback, which can match the perception range, spatial resolution, and stretchability of the skin. Pressure-amplification structures are fabricated using a scalable self-assembly process to ensure an output pressure beyond the skin perception threshold. Due to the minimized device size, the actuator array can be fabricated with a sufficiently high spatial resolution, which makes the haptic device applicable for skin locations with the highest spatial acuity. A haptic feedback system is demonstrated by employing the developed soft actuators and highly sensitive pressure sensors. Two proof-of-concept applications are developed to illustrate the capability of transferring information related to surface textures and object shapes acquired at the robot side to the user side.

Chen, Si↗

Silicon compatible Sn-based resistive switching memory

Large banks of cheap, fast, non-volatile, energy efficient, scalable solid-state memories are an increasingly essential component for today's data intensive computing. Conductive-bridge random access memory (CBRAM) – which involves voltage driven formation and dissolution of Cu or Ag filaments in a Cu (or Ag) anode/dielectric (HfO 2 or Al 2 O 3 )/inert cathode device – possesses the necessary attributes to fit the requirements. Cu and Ag are, however, fast diffusers and known contaminants in silicon microelectronics. In this paper, employing a criterion for electrode metal selection applicable to cationic filamentary devices and using first principles calculations for estimating diffusion barriers in HfO 2 , we identify tin (Sn) as a rational, silicon CMOS compatible replacement for Cu and Ag anodes in CBRAM devices. We then experimentally fabricate Sn based CBRAM devices and demonstrate very fast, steep-slope memory switching as well as threshold switching, comparable to Cu or Ag based devices. Furthermore, time evolution of the cationic filament formation along with the switching mechanism is discussed based on time domain measurements (I vs. t) carried out under constant voltage stress. Finally, the time to threshold is shown to be a function of both the voltage stress (V stress ) as well as the initial leakage current (I 0 ) through the device.

42 ENGINEERING↗

Critical role of acceptor dopants in designing highly stable and compatible proton-conducting electrolytes for reversible solid oxide cells

Proton-conducting electrolytes are receiving increasing attention due to their high ionic conductivity at intermediate temperatures, enabling the operation of solid oxide cells with high energy efficiency at low cost. However, the effect of B-site dopants on the properties of doped barium hafnate-cerate electrolyte materials, especially in single cells under operating conditions, has not been systematically studied. Here we report our findings in the development of a series of proton-conducting electrolytes with a general formula of BaHf 0.1 Ce 0.7 R 0.2 O 3–δ (BHCR172, R = Yb, Er, Y, Gd, Sm). Here, the results reveal that electrical conductivity, ionic transference number, chemical stability against steam and CO 2 , and compatibility with NiO during sintering are all closely correlated with the dopant size. In particular, the reaction with NiO is found to strongly affect the properties of the electrolytes and hence cell performance. Among all tested compositions, BaHf 0.1 Ce 0.7 Yb 0.2 O 3–δ (BHCYb172) shows excellent chemical stability and minimal reactivity towards NiO, as predicted from density functional theory (DFT)-based calculations and confirmed by experimental results. In addition, proton-conducting reversible solid oxide cells (P-ReSOCs) based on the optimized electrolyte composition, BHCYb172, demonstrate exceptional performance and stability, achieving a remarkable peak power density of 1.74 W cm –2 (O 2 as the oxidant) at 600 °C in the fuel cell mode and a high current density of 2.0 A cm –2 at 1.3 V and 600 °C in the steam electrolysis mode while maintaining excellent durability for over 1000 h.

25 ENERGY STORAGE↗

Nuclear corrections in {nu}A DIS and their compatibility with global NPDF analyses

We perform a global {chi}{sup 2}-analysis of nuclear parton distribution functions using data from charged current neutrino--nucleus({nu}A) deep inelastic scattering (DIS), charged-lepton--nucleus (l{sup {+-}A}) DIS, and the Drell-Yan (DY) process. We show that the nuclear corrections in {nu}A DIS are not compatible with the predictions derived from l{sup {+-}A} DIS and DY data. We quantify this result using a hypothesis-testing criterion based on the {chi}{sup 2} distribution which we apply to the total {chi}{sup 2} as well as to the {chi}{sup 2} of the individual data sets. We find that it is not possible to accommodate the data from {nu}A and l{sup {+-}A} DIS by an acceptable combined fit. Our result has strong implications for the extraction of both nuclear and proton PDFs using combined neutrino and charged lepton data sets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An (ultra) high-vacuum compatible sputter source for oxide thin film growth

A miniaturised CF-38 mountable sputter source for oxide and metal thin film preparation with enhanced high-vacuum and ultra-high-vacuum compatibility is described. The all home-built sputtering deposition device allows a high flexibility also in oxidic sputter materials, suitable deposition rates for preparation of films in the nm- and the sub-monolayer regime and excellent reliability and enhanced cleanliness for usage in UHV chambers. For a number of technologically important – yet hardly volatile – materials, the described source represents a significant improvement over thermal deposition techniques like electron-beam- or thermal evaporation, as especially the latter are no adequate tool to prepare atomically clean layers of refractory oxide materials. Furthermore, it is superior to commercially available magnetron sputter devices, especially for applications, where highly reproducible sub-monolayer thin film preparation under very clean UHV conditions is required (e.g., for studying phase boundary effects in catalysis). The device in turn offers the usage of a wide selection of evaporation materials and special target preparation procedures also allow the usage of pressed oxide powder targets. To prove the performance of the sputter-source, test preparations with technologically relevant oxide components, comprising ZrO{sub 2} and yttrium-stabilized ZrO{sub 2}, have been carried out. A wide range of characterization methods (electron microscopy, X-ray photoelectron spectroscopy, low-energy ion scattering, atomic force microscopy, and catalytic testing) were applied to demonstrate the properties of the sputter-deposited thin film systems.

36 MATERIALS SCIENCE↗

A variable-temperature nanostencil compatible with a low-temperature scanning tunneling microscope/atomic force microscope

We describe a nanostencil lithography tool capable of operating at variable temperatures down to 30 K. The setup is compatible with a combined low-temperature scanning tunneling microscope/atomic force microscope located within the same ultra-high-vacuum apparatus. The lateral movement capability of the mask allows the patterning of complex structures. To demonstrate operational functionality of the tool and estimate temperature drift and blurring, we fabricated LiF and NaCl nanostructures on Cu(111) at 77 K.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bio-compatibility, surface and chemical characterization of glow discharge plasma modified ZnO nanocomposite polycarbonate

Bio compatibility is an important issue for synthesis of biomedical devices, which can be tested by bioadoptability and creations of active site to enhance the bacterial/cell growth in biomedical devices. Hence a systematic study was carried out to characterize the effects of Nitrogen ion plasma for creations of active site in nano composite polymer membrane. Nano particles of ZnO are synthesized by chemical root, using solution casting nano composite polymeric membranes were prepared and treated with Nitrogen ion plasma. These membranes were characterized by different technique such as optical microscopy, SEM- Scanning electron microscope, optical transmittance, Fourier transform infrared spectroscopy. Then biocompatibility for membranes was tested by testing of bio-adoptability of membrane.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and initial characterization of a compact, ultra high vacuum compatible, low frequency, tilt accelerometer

A compact tilt accelerometer with high sensitivity at low frequency was designed to provide low frequency corrections for the feedback signal of the Advanced Laser Interferometer Gravitational Wave Observatory active seismic attenuation system. It has been developed using a Tungsten Carbide ceramic knife-edge hinge designed to avoid the mechanical 1/f noise believed to be intrinsic in polycrystalline metallic flexures. Design and construction details are presented; prototype data acquisition and control limitations are discussed. The instrument's characterization reported here shows that the hinge is compatible with being metal-hysteresis-free, and therefore also free of the 1/f noise generated by the dislocation Self-Organized Criticality in the metal. A tiltmeter of this kind will be effective to separate the ground tilt component from the signal of horizontal low frequency seismometers, and to correct the ill effects of microseismic tilt in advanced seismic attenuation systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphase flow modeling based on the hyperbolic thermodynamically compatible systems theory

An application of the theory of thermodynamically compatible hyperbolic systems to design a multiphase compressible flow models is discussed. With the use of such approach the governing equations are derived from the first principles, formulated in a divergent form and can be transformed to a symmetric hyperbolic system in the sense of Friedrichs. A usage of the proposed approach is described for the development of multiphase compressible fluid models, including two-phase flow models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband enhancement of local density of states using silicon-compatible hyperbolic metamaterials

Light emitting silicon quantum dots by colloidal synthesis were uniformly spin-coated into a 20 nm-thick film and deposited atop a hyperbolic metamaterial of alternating TiN and SiO{sub 2} sub-wavelength layers. Using steady-state and time-resolved photoluminescence spectroscopy as a function of the emission wavelength in partnership with rigorous electromagnetic modeling of dipolar emission, we demonstrate enhanced Local Density of States and coupling to high-k modes in a broad spectral range. These findings provide an alternative approach for the engineering of novel Si-compatible broadband sources that leverage the control of radiative transitions in hyperbolic metamaterials and the flexibility of the widespread Si platform.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A controllable IC-compatible thin-film fuse realized using electro-explosion

A controllable IC-compatible thin-film fuse was developed that had Al/SiO{sub 2} thin-film stacks on a silicon substrate. The micro fuse has both a traditional mode and a controllable mode when applied as a fuse. It blows at 800 mA and 913.8 mV in the traditional mode. In the controllable mode, it blows within 400 ns at 10 V. It can be used for small electronic elements as well as electropyrotechnic initiators to improve the no-firing current.

36 MATERIALS SCIENCE↗

Improved core-edge compatibility using impurity seeding in the small angle slot (SAS) divertor at DIII-D

Impurity seeding studies in the slot divertor (SAS) at DIII-D have revealed a strong relationship between the detachment onset and pedestal characteristics with both target geometry and impurity species. N 2 seeding in the slot has led to the first simultaneous observation of detachment on the entire suite of boundary diagnostics viewing the SAS without degradation of core confinement. SOLPS-ITER simulations with D+C+N, full cross-field drifts and n-n collisions activated are performed for the first time in DIII-D to interpret the behavior. This illustrates a strong effect of divertor configuration and plasma drifts on the recycling source distribution with significant consequences on plasma flows. Flow reversal is found for both main ions and impurities affecting strongly the impurity transport and providing an explanation for the observed dependence on strike point location of the detachment onset and impurity leakage found in the experiments. Matched discharges with either nitrogen or neon injection show that while nitrogen does not significantly affect the pedestal, neon leads to increased pedestal pressure gradient and improved pedestal stability. Little nitrogen penetrates in the core, but a great amount of neon is found in the pedestal consistent with the different ionization potentials of the two impurities. This research demonstrates that neutral and impurity distributions in the divertor can be controlled through variations in strike point locations in a fixed baffle structure. Divertor geometry combined with impurity seeding enables mitigated divertor heat flux balancing core contamination and thus leading to enhanced divertor dissipation and improved core-edge compatibility which are essential for ITER and for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared compatible rapid mixer to probe millisecond chemical kinetics

Fast microfluidic mixers are a valuable tool for studying solution-phase chemical reaction kinetics and molecular processes with spectroscopy. However, microfluidic mixers that are compatible with infrared vibrational spectroscopy have seen only limited development due to the poor infrared transparency of the current microfabrication material. We describe the design, fabrication, and characterization of CaF2-based continuous flow turbulent mixers, which are capable of measuring kinetics in the millisecond time window with infrared spectroscopy, when integrated into an infrared microscope. Kinetics measurements demonstrate the ability to resolve relaxation processes with 1 millisecond time resolution, and straightforward improvements are described that should result in sub-100 µs time-resolution.

Instruments & Instrumentation↗

Design of a double-sided laser heating compatible piezoelectrically driven dynamic diamond anvil cell

Piezoelectrically driven dynamic diamond anvil cells are generally limited to use at room temperature due to spatial conflicts with the optical components necessary for double-sided laser heating. Here, this work describes the design of a double-sided laser-heating-compatible, piezoelectrically driven dynamic diamond anvil cell (LH-dDAC) that expands the range of experimentally accessible compression rate/temperature space. By developing a spatially in-parallel design, in which the diamond anvils and the piezo actuators lie alongside each other, the total length of the apparatus is reduced to 66.5 mm. The new LH-dDAC is capable of probing both overpressure and compression-rate effects on the kinetics of phase transitions. We illustrate the capability of the new LH-dDAC using the following cases: (1) a simultaneous pressure and temperature jump from 19.5 GPa and room temperature to 40 GPa and ≈1550 K and (2) a controlled compression ramp at ≈1850 K and ≈100 GPa/s. By pairing rapid compression with laser heating, the new LH-dDAC opens the door to studies of diffusionally controlled transformations at high pressures and temperatures.

Copley, J. A. [Princeton Univ., NJ (United States)↗

Non-invasive, MRI-compatible fibreoptic device for functional near-IR reflectometry of human brain

A non-invasive device for measuring blood oxygen variations in human brain is designed, implemented, and tested for MRI compatibility. The device is based on principles of near-IR reflectometry; power LEDs serve as sources of probing radiation delivered to patient skin surface through optical fibres. Numerical Monte Carlo simulations of probing radiation propagation in a multilayer brain model are performed to evaluate signal levels at different source - detector separations at three operation wavelengths and an additional wavelength of 915 nm. It is shown that the device can be applied for brain activity studies using power LEDs operating at 830 and 915 nm, while employment of wavelength of 660 nm requires an increased probing power. Employment of the wavelength of 592 nm in the current configuration is unreasonable. (application of lasers and laser-optical methods in life sciences)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Least-Squares Transport Equation Compatible with Voids

Standard second-order self-adjoint forms of the transport equation, such as the even-parity, odd-parity, and self-adjoint angular flux equation, cannot be used in voids. Perhaps more important, they experience numerical convergence difficulties in near-voids. Here we present a new form of a second-order self-adjoint transport equation that has an advantage relative to standard forms in that it can be used in voids or near-voids. Our equation is closely related to the standard least-squares form of the transport equation with both equations being applicable in a void and having a nonconservative analytic form. However, unlike the standard least-squares form of the transport equation, our least-squares equation is compatible with source iteration. It has been found that the standard least-squares form of the transport equation with a linear-continuous finite-element spatial discretization has difficulty in the thick diffusion limit. Here we extensively test the 1D slab-geometry version of our scheme with respect to void solutions, spatial convergence rate, and the intermediate and thick diffusion limits. We also define an effective diffusion synthetic acceleration scheme for our discretization. Our conclusion is that our least-squares S n formulation represents an excellent alternative to existing second-order S n transport formulations

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗