Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Investigation of isovaline enantiomeric excesses in CM meteorites using liquid chromatography time of flight mass spectrometry

The enantiomeric abundances of the alpha-dialkyl amino acid isovaline were measured in the CM2 meteorites Murchison and LEW 90500 using a new liquid chromatography-time of flight-mass spectrometry (LC-ToF-MS) technique coupled with OPA/NAC derivatization and UV fluorescence detection. Previous analyses of Murchison have shown that L-enantiomeric excesses of isovaline range from 0 to 15.2% with significant variation between meteorite fragments [1]. For this study, hot water extracts of interior fragments (> 2 cm from fusion crust) of the Murchison (USNM 6650.2, mass 6 g) and LEW 90500 (split 69, parent 1, mass 5 g) carbonaceous meteorites were analyzed. Enantiomeric excesses were measured using the single ion LC-ToF-MS trace for the OPA/NAC derivative of isovaline at d z 393.15 (Fig. 1). L-isovaline excesses in these meteorite samples ranged from 18.9 to 20.5% for Murchison and -0.5 to 3.0% for LEW 90500. The measured values for Murchison are the largest enantiomeric excesses for isovaline reported to date. The enantiomeric excesses of L-isovaline cannot be the result of interference from other C5 amino acid isomers present in the meteorites or terrestrial contamination from the landing site environments. The L-isovaline excesses in Murchison are inconsistent with the synthesis of all of the isovaline by the Strecker-cyanohydrin pathway on the CM meteorite parent body. The mechanism(s) for the formation of the enantiomeric asymmetry in isovaline in Murchison are currently unknown and it is not clear how the asymmetry of alpha-dialkyl amino acids could be transferred to the a-hydrogen protein amino acids common in all life on Earth today.

Glavin, Daniel P.↗

AMINO ACID ANALYSES OF THE ANTARCTIC CM2 METEORITES ALH 83100 AND LEW 90500 USING LIQUID CHROMATOGRAPHY-TIME OF FLIGHT-MASS SPECTROMETRY

The investigation of organic compounds in primitive carbonaceous meteorites provides a record of the chemical processes that occurred in the early solar system. In particular, amino acids have been shown to be potential indicators in tracing the nature of carbonaceous chondrite parent bodies [ 13. The delivery of amino acids by carbonaceous chondrites to the early Earth could have been any important source of the Earth's prebiotic organic inventory [2]. Over 80 different amino acids have been detected in the Murchison CM2 meteorite, most of them completely non-existent in the terrestrial biosphere [3]. We have optimized a new liquid chromatography-time-of-flight-mass spectrometry (LC-ToF-MS) technique coupled with OPAMAC derivatization in order to detect amino acids in meteorite extracts by UV fluorescence and exact mass simultaneously. The detection limit of the LC-ToF-MS instrument for amino acids is at least 3 orders of magnitude lower than traditional GC-MS techniques. Here we report on the first analyses of amino acids and their enantiomeric abundances in the CM2 carbonaceous meteorites ALH 83100, LEW 90500, and Murchison using this new LC-ToF-MS instrument configuration. Amino acid analyses of any kind for the CM meteorite ALH 83100 have not previously been reported.

Glavin, D. P.↗

Thermal modulation for gas chromatography

A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a recirculating fluid cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary. The capillary can include more than one separate thermally modulated sections.

Hasselbrink, Ernest F.↗

Thermal modulation for gas chromatography

A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary.

Hasselbrink, Ernest F.↗

Stable Chlorine Isotopes and Elemental Chlorine by Thermal Ionization Mass Spectrometry and Ion Chromatography; Martian Meteorites, Carbonaceous Chondrites and Standard Rocks

Recently significantly large mass fractionation of stable chlorine isotopes has been reported for terrestrial and lunar samples [1,2]. In addition, in view of possible early solar system processes [3] and also potential perchlorate-related fluid/microbial activities on the Martian surface [4,5], a large chlorine isotopic fractionation might be expected for some types of planetary materials. Due to analytical difficulties of isotopic and elemental analyses, however, current chlorine analyses for planetary materials are controversial among different laboratories, particularly between IRMS (gas source mass spectrometry) and TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1,6,7] for isotopic analyses, as well as between those doing pyrohydrolysis and other groups [i.e. 6,8]. Additional careful investigations of Cl isotope and elemental abundances are required to confirm real chlorine isotope and elemental variations for planetary materials. We have developed a TIMS technique combined with HF-leaching/ion chromatography at NASA JSC that is applicable to analysis of small amounts of meteoritic and planetary materials. We present here results for several standard rocks and meteorites, including Martian meteorites.

Nakamura, N.↗

Analysis of Organic Molecules Extracted from Mars Analogues and Influence of Their Mineralogy Using N-Methyl-N-(tert-butyldimethylsilyl)Trifluoroacetamide Derivatization Coupled with Gas Chromatography Mass Spectrometry in Preparation for the Sample Analysis at Mars Derivatization Experiment on the Mars Science Laboratory Mission

The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids will require a chemical extraction and derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed, a one-pot extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment on the Mars Science Laboratory (MSL). The temperature and duration the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 C for several minutes of a variety of terrestrial Mars analogue materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analogue materials that contained high abundances of hydrated minerals and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA, The combination of pyrolysis and two different chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars,

Stalport, F.↗

A Search for Amino Acids and Nucleobases in the Martian Meteorite Roberts Massif 04262 Using Liquid Chromatography-Mass Spectrometry

The investigation into whether Mars contains signatures of past or present life is of great interest to science and society. Amino acids and nucleobases are compounds that are essential for all known life on Earth and are excellent target molecules in the search for potential Martian biomarkers or prebiotic chemistry. Martian meteorites represent the only samples from Mars that can be studied directly in the laboratory on Earth. Here, we analyzed the amino acid and nucleobase content of the shergottite Roberts Massif (RBT) 04262 using liquid chromatography-mass spectrometry. We did not detect any nucleobases above our detection limit in formic acid extracts; however, we did measure a suite of protein and nonprotein amino acids in hot-water extracts with high relative abundances of beta-alanine and gamma-amino-eta-butyric acid. The presence of only low (to absent) levels of several proteinogenic amino acids and a lack of nucleobases suggest that this meteorite fragment is fairly uncontaminated with respect to these common biological compounds. The distribution of straight-chained amine-terminal eta-omega-amino acids in RBT 04262 resembled those previously measured in thermally altered carbonaceous meteorites. A carbon isotope ratio of -24(0/00) +/- 6(0/00) for beta-alanine in RBT 04262 is in the range of reduced organic carbon previously measured in Martian meteorites (Steele et al. 2012). The presence of eta-omega-amino acids may be due to a high temperature Fischer-Tropschtype synthesis during igneous processing on Mars or impact ejection of the meteorites from Mars, but more experimental data are needed to support these hypotheses.

Laboratory analysis↗

Analysis of Mixed Aryl/Alkyl Esters by Pyrolysis Gas Chromatography-Mass Spectrometry in the Presence of Perchlorate

Mars is an important target for Astrobiology. A key goal of the MSL mission was to determine whether Mars was habitable in the past, a que-tion that has now been definitely determined to be yes. Another key goal for Mars exploration is to understand the origin and distribution of organic material on Mars; this question is being addressed by the SAM instrument on MSL, and will also be informed by two upcoming Mars exploration missions, ExoMars and Mars 2020. These latter two missions have instrumentation capable of detecting and characterize organic molecules. Over the next decade, these missions will analyze organics in surface, near-surface and sub-surface samples. Each mission has the capability to analyze organics by different methods (pyrolysis gas chromatography-mass spectrometry [py-GC-MS]; laser desorption and thermal volatilization GC-MS; and Raman spectroscopy). Plausibly extraterrestrial organics were recently discovered by the Mars Science Laboratory (MSL), providing an important first step towards understanding the organic inventory on Mars [1]. The compounds detected were chlorobenzenes and chloroalkanes, but it was argued that chlorination of these compounds occurred during pyrolysis of samples containing unchlorinated organics in the presence of perchlorate. A recent report analyzed a suite of aromatic (benzene, toluene, benzoic acid, phthalic acid, and mellitic acid) and aliphatic (acetic acid, propane, propanol, and hexane) by pyrolysis under SAM-like conditions in the presence of perchlorate to attempt to constrain possible precursor molecules for the organic molecules detected on Mars. For aromatic compounds, the aromatic acids all readily produced SAM-relevant chlorobenzes, whereas benzene and toluene did not. This observation suggests that the chlorobenzene detected on Mars could have derived from compounds like mellitic acid, consistent with the previous hypothesis by Benner et al. [3]. Among the aliphatic molecules, it was shown that pyrolysis of alkanes and alcohols in the presence of perchlorates produced polychlorine containing chloro-alkanes similar to what was observed on Mars. Surpris-ingly, however, similar treatment of acetic acid pro-duced chloroketones, instead, and no chloroalkanes were reported. This suggests that the chloroalkanes detected in the Sheepbed mudstone were not derived from aliphatic carboxylic acids, but instead were from more reduced alcohols or even alkanes, or perhaps were degradation products of more complicated organic material. Because organics analyses on mars will rely heavily on py-GC-MS of perchlorate-containing samples over the next decade, it is important to understand the fate of organic molecules of biotic and abiotic origin under such conditions. In this work we begin a series of experiments to improve our understanding of products generated during py-GC-MS of increasingly complex organic molecules (esters, amides, peptides, nucleic acids, fatty acids) in the presence of perchlorate.

Burton, A. S.↗

Ion Chromatography-on-a-chip for Water Quality Analysis

We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

Kidd, R. D.↗

Coupling Online Conductivity with Offline Ion Chromatography Measurements using the Particle-into-Liquid Sampler

A particle-into-liquid sampler has been combined with a flow through conductivity cell to provide a continuous, non-destructive, online measurement in support of offline ion chromatography analysis. The conductivity measurement provides a rapid assessment of the total ion concentration augmenting the slower batch data from the offline analysis and is developed primarily to assist airborne measurements, where fast time response is essential. A model of the conductivity was developed for measured ions and excellent closure is derived for laboratory-generated aerosols. The PILS-conductivity measurement was extensively tested during the NASA Cloud, Aerosol and Monsoon Processes: Philippines Experiment (CAMP2Ex) across nineteen research flights and the conductivity data was found to augment the temporal capability of the PILS instrument for assessing ionic species, allowing sub-minute variability to be resolved. Through the sampling of a diverse range of ambient aerosol, including biomass burning, fresh and aged urban pollution, the conductivity measurement offered additional useful information to untangle the composition of complex aerosol mixtures, specifically for assessing acidic aerosol conditions.

Ewan Colin Crosbie↗

A Sensitive Quantitative Analysis of Abiotically Synthesized Short Homopeptides using Ultraperformance Liquid Chromatography and Time-of-Flight Mass Spectrometry

In the origins of life field understanding the abiotic polymerization of simple organic monomers (e.g., amino acids) into larger biomolecules (e.g., oligopeptides), remains a seminal challenge. Recently, preliminary observations showed a limited set of peptides formed in the presence of the plausible prebiotic phosphorylating agent, diamidophosphate (DAP), highlighting the need for an analytical tool to critically evaluate the ability of DAP to induce oligomerization of simple organics under aqueous conditions. However, performing accurate and precise, targeted analyses of short oligopeptides remains a distinct challenge in the analytical chemistry field. Here, we developed a new technique to detect and quantitate amino acids and their homopeptides in a single run using ultraperformance liquid chromatography-fluorescence detection/time of flight mass spectrometry. Over an 8-minute retention time window, 18 target analytes were identified and quantitated, 16 of which were chromatographically separated at, or near baseline resolution. Compound identity was confirmed by accurate mass analysis using a 10 ppm mass tolerance window. This method featured limits of detection < 5 nM (< 1 fmol on column) and limits of quantitation (LOQs) <15 nM (< 3 fmol on column). The LODs and LOQs were upwards of ∼28x and ∼788x lower, respectively, than previous methods for the same analytes, highlighting the quantifiable advantages of this new method. Both detectors provided good quantitative linearity (R(exp 2) > 0.985) for all analytes spanning concentration ranges ∼3 - 4 orders of magnitude. We performed a series of laboratory experiments to investigate DAP-mediated oligomerization of amino acids and peptides and analyzed experimental products with the new method. DAP readily polymerized amino acids and peptides under a range of simulated environmental conditions. This research underscores the potential of DAP to have generated oligopeptides on the primordial Earth, enhancing prebiotic chemical diversity and complexity at or near the origin of life.

Prebiotic Chemistry and Analytical Chemistry↗

Estimation of brassylic acid by gas chromatography-mass spectrometry

The main focus of this work is to estimate Brassylic Acid (BA) using gas chromatography-mass spectrometry (GC-MS). BA is a product obtained from the oxidative cleavage of Erucic Acid (EA). BA has various applications for making nylons and high performance polymers. BA is a 13 carbon compound with two carboxylic acid functional groups at the terminal end. BA has a long hydrocarbon chain that makes the molecule less sensitive to some of the characterization techniques. Although BA can be characterized by NMR, both the starting material (EA) and products BA and nonanoic acid (NA) have peaks at similar {delta}, ppm values. Hence it becomes difficult for the quick estimation of BA during its synthesis.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dielectrokinetic chromatography and devices thereof

Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

47 OTHER INSTRUMENTATION↗

Structural Evolution of Polylactide Molecular Bottlebrushes: Kinetics Study by Size Exclusion Chromatography, Small Angle Neutron Scattering and Simulations

Structural evolution from poly(lactide) (PLA) macromonomer to resultant PLA molecular bottlebrush during ring opening metathesis polymerization (ROMP) was investigated for the first time by combining size exclusion chromatography (SEC), small-angle neutron scattering (SANS) and coarse-grained molecular dynamics (CG-MD) simulations. Multiple aliquots were collected at various reaction times during ROMP, and subsequently analyzed by SEC and SANS. The two complementary techniques enable the understanding of systematic changes in conversion, molecular weight and dispersity as well as structural details of PLA molecular bottlebrushes. CG-MD simulation not only predicts the experimental observations, but it also provides further insight into the analysis and interpretation of data obtained in SEC and SANS experiments. We find that PLA molecular bottlebrushes undergo three conformational transitions with increasing conversion (i.e., increasing the backbone length): (1) from an elongated to a globular shape due to longer side chain at lower conversion, (2) from a globular to an elongated shape at intermediate conversion caused by excluded volume of PLA side chain, and (3) the saturation of contour length at higher conversion due to chain transfer reactions.

Pickel, Deanna L↗

Dielectrokinetic chromatography devices

Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic devices for liquid chromatography-mass spectrometry and microscopic imaging

Systems, methods, and apparatus provide integration of microscopic imaging and liquid chromatography-mass spectrometry on a microfluidic device. In one aspect, an apparatus includes a first wafer, a second wafer, and an emitter. The emitter is disposed between the first wafer and the second wafer. The first wafer defines a sample input hole. The first wafer and the second wafer define a first channel, the first channel including a first end and a second end. The first end of the first channel is proximate the sample input hole. The first channel is configured to contain separation media. The second end of the first channel is proximate the emitter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗