Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

CCD time-resolved photometry of faint cataclysmic variables. III

CCD time-resolved photometry in V, B, and near-IR for 17 faint cataclysmic variables (CVs) is presented and analyzed. The data are obtained at Kitt Peak National Observatory, the Perkins reflector, Lowell Observatory, and the Observatorio del Roque de los Muchachos from April-June 1989. The degree of variability and periodicities for the CVs are examined. It is observed that the variability of most of the stars is consistent with CV class behavior. Orbital periods for five CVs are determined, and three potential eclipsing systems are detected.

Howell, Steve B.↗

A comparison of KPNO CCD and coadded DAO photographic spectroscopic data

Spectra of field horizontal-branch A stars obtained with the coude feed telescope of the KPNO are compared with coadded spectrograms derived from the 2.4-m coude camera of the Dominion Astrophysical Observatory (DAO) in order to study variations in equivalent width for the same star. The KPNO and DAO data are also compared with the observations of Adelman and Hill (1987). It is observed that the SNRs are between 100-240 for the CCD images, 140 for the 6.8 A/mm coadditions, and 180 for the 2.4 A/mm coadditions, and that there is a 14 percent systematic difference in the equivalent widths. Factors which may affect the equivalent-width scale are discussed.

Adelman, Saul J.↗

Altering Interline Transfer In A CCD To Reduce Saturation

In proposed interline-transfer timing scheme for charge-coupled-device (CCD) video imaging array, charges accumulated during some fraction of frame period swept out and dumped to prevent overloading and saturation in intensely illuminated photosites. Excess charges swept out at highest possible rate, while charges used for imaging read out at rate lower but was highest rate that provides complete transfer of charge on array and handled by subsequent signal-processing equipment.

Rentsch, Edward M.↗

A CCD comparison of outer Jovian satellites and Trojan asteroids

The eight small outer Jovian satellites are not as well known as the brighter, more illustrious Galilean satellites. They are divided into two groups, each containing four satellites; the inner group travels in prograde orbits while the outer group travels in retrograde orbits. From the distinct orbital characteristics of the two groups, most of the theories of their origin involve the capture and breakup of two planetesimals upon entry into the atmosphere of proto-Jupiter. Their proximity to the Trojans asteroids has led to conjectures of a link between them and the Trojans. However, Tholen and Zellner (1984) found no red spectrum among six of the satellites and postulated that they were all C-type objects; therefore, they were unlikely to be derivatives of the Trojan population. Charge-coupled device (CCD) photometry and spectroscopy of the eight outer Jovian satellites obtained from 1987 to 1989 and a comparison between these eight satellites and the Trojan asteroids are presented.

Luu, Jane X.↗

CCD observations of orbital debris

A portable 31 cm aperture f/1.3 Schmidt telescope with a CCD sensor at the prime focus has been designed and constructed to carry out photometric studies of earth-orbiting debris. When operated in the time delay integration mode in which the readout rate is matched to the predicted motion of the satellite, this system reaches a limiting diameter of about 10 cm for particles at 400 km height and albedo 0.1. It is used for statistical studies of phase angle effects and for swarm-to-swarm albedo differences between several selected debris groups which include the Cosmos 1275, Cosmos 1375, Landsat 1, Landsat 3, NOAA 3, Nimbus 4, Solwind, and Spot-1/Viking groups.

Henize, Karl G.↗

Advanced CCD imager technology for use from 1 to 10,000 A

A low-noise, high-sensitivity charge-coupled-device (CCD) technology for imaging applications extending from the soft X-ray (1 A) to the near-infrared (10,000 A) regimes was developed together with a fabrication technology for making back-illuminated versions of these devices with quantum efficiencies as high as 90 percent from 5000 to 7000 A. The efforts have focused on two devices, a 64 x 64 pixel back-illuminated imager with two output ports that operates at 2000 frames per second with 23 electrons read noise, and a larger device, with 420 x 420 pixel format, designed for lower frame rates with noise as low as 1.5 electrons and used at visible, UV, and X-ray wavelengths. Applications to plasma diagnostics include Thomson scattering and high-frame-rate imaging in the visible, as well as X-ray imaging and bolometry.

Twichell, J. C.↗

Signal-to-noise considerations for sky-subtracted CCD data

The standard equation for calculating the uncertainty of photometry obtained from CCDs does not correctly consider the random errors, or 'noise', introduced into observations by procedures used in reducing the data. This paper presents a thorough derivation of the theoretical error equation that considers the contributions from all internal noise sources in the signal-to-noise ratio (S/N) of a sky-subtracted image. A simplified version used for estimating the internal errors from empirical data is also derived. The propagation of noise through the data-reduction process is illustrated through a series of equations for the change in S/N that results from a variety of different operations performed on a CCD frame. Comparing these effects with the results expected for an observation made with an ideal detector suggests a number of ways to improve the precision of photometry through the practices employed in obtaining and reducing the observations.

Newberry, Michael V.↗

Measuring the direct sky brightness on CCD images

A new method of determining the background sky brightness for stellar photometric measurements with CCDs is described. By fitting and subtracting stellar profiles from a CCD image, one can measure the sky brightness directly at the position of each star after subtraction. These sky values can then be used for the next round of profile fitting and subtraction. The 'direct sky' brightness for a star is the convergent value of the sky after a few such iterations and is the most direct measurement of the line-of-sight contribution of the background to the observed magnitude of a star. Using this method, a decrease of the random photometric errors by more than a factor of two over standard methods is possible, with the most significant improvements for stars in very crowded regions and areas of strong and highly variable nebulosity.

Parker, Joel WM.↗

Wire transfer of charge packets using a CCD-BBD structure for charge-domain signal processing

A structure for the virtual transfer of charge packets across metal wires is described theoretically and is experimentally verified. The structure is a hybrid of charge-coupled device (CCD) and bucket-brigade device (BBD) elements and permits the topological crossing of charge-domain signals in low power signal processing circuits. A test vehicle consisting of 8-, 32-, and 96-stage delay lines of various geometries implemented in a double-poly, double-metal foundry process is used to characterize the wire-transfer operation. Transfer efficiency ranging between 0.998 and 0.999 is obtained for surface n-channel devices with clock cycle times in the range from 40 ns to 0.3 ms. Transfer efficiency as high as 0.9999 is obtained for buried n-channel devices. Good agreement is found between experiment and simulation.

Fossum, Eric R.↗

CCD time-resolved photometry of faint cataclysmic variables. IV

Time-resolved CCD photometry in V, B, and the near-IR has been obtained, with average time-series length of 3 hours, for 15 certified or candidate cataclysmic-variable faint stars. Orbital periods are found in three of the stars, and nine others are noted to exhibit evidence leading toward confirmation of cataclysmic-variable status. The characteristics of PG 0917+342 and PG 2240+193 are as yet unclear.

Howell, Steve B.↗

An abuttable CCD imager for visible and X-ray focal plane arrays

A frame-transfer silicon charge-coupled-device (CCD) imager has been developed that can be closely abutted to other imagers on three sides of the imaging array. It is intended for use in multichip arrays. The device has 420 x 420 pixels in the imaging and frame-store regions and is constructed using a three-phase triple-polysilicon process. Particular emphasis has been placed on achieving low-noise charge detection for low-light-level imaging in the visible and maximum energy resolution for X-ray spectroscopic applications. Noise levels of 6 electrons at 1-MHz and less than 3 electrons at 100-kHz data rates have been achieved. Imagers have been fabricated on 1000-Ohm-cm material to maximize quantum efficiency and minimize split events in the soft X-ray regime.

Burke, Barry E.↗

CCD photometry of NGC 6101 - Another globular cluster with blue straggler stars

Results are presented on CCD photometric observations of a large sample of stars in the southern globular cluster NGC 6101, and the procedures used to derive the color-magnitude (C-M) diagram of the cluster are described. No indication was found of any difference in age, at the less than 2 Gyr level, between NGC 6101 cluster and other clusters of similar abundance, such as M92. The C-M diagram revealed a significant blue straggler population. It was found that, in NGC 6101, these stars are more centrally concentrated than the cluster subgiants of similar magnitude, indicating that the blue stragglers have larger masses. Results on the magnitude and luminosity function of the sample are consistent with the bianry mass transfer or merger hypotheses for the origin of blue straggler stars.

Sarajedini, Ata↗

Preventing Blooming In CCD Images

Clocking scheme for charge-coupled-device (CCD) imaging photodetector prevents smearing of bright spots and eliminates residual images. Also imposes charge-collecting electric field of optimum-full-well configuration, minimizes nonuniformities among picture elements, and keeps dark current low. Works under almost any lighting conditions.

Janesick, James↗

Discovery of near-Earth asteroids by CCD scanning

The found near-Earth asteroid are different objects with peculiar orbits. With the new technique of CCD scanning we entered the domain of the smallest, the fastest, and the closest near-Earth asteroids. The results are presented.

Gehrels, Tom↗

Time-lapse CCD imagery of plasma-tail motions in Comet Austin

The appearance of the bright comet Austin 1989c1 in April-May of 1990 allowed us to test a new imaging instrument at the Joint Observatory for Cometary Research (JOCR). It is a 300mm lens/charge coupled device (CCD) system with interference filters appropriate for cometary emissions. The 13 frames were made into a time-lapse movie showing the evolution of the plasma tail. We were able to follow at least two large-scale waves out through the main tail structure. During the sequence, we saw two new tail rays form and undergo similar wave motion.

Klinglesmith, Daniel A., III↗

The Mees CCD imaging spectrograph

The Mees CCD (MCCD0 instrument is an imaging spectroscopy device which uses the 25-cm coronagraph telescope and the 3.0-m Coude spectrograph at Mees Solar Observatory on Haleakala, Maui. The instrument works with resolving power up to about 200,000 with significant throughput from 3934 A (Ca II K) to about 10,000 A. A fast guiding active mirror stabilizes the image during observations. A rapidly writing magnetic tape storage system allows observations to be recorded at 256 kbytes/s. Currently, the MCCD is used for imaging spectroscopy of solar flares at 6563 A (H-alpha), and velocity measurements of umbral oscillations; future plans include emission line studies of active region coronae, and photospheric studies of solar oscillations.

Penn, Matthew J.↗

An intensified CCD detector using the phosphor TPB

The Research Amplifying Imaging Detector consists of a microchannel plate image intensifier with a thin coating (3500-10,000 A) of the phosphor tetraphenyl-butadiene (TPB) on the entrance window to convert EUV radiation to visible, and coupled via a lens to a CCD detector. This design allows great flexibility in selecting the pixel size and field of view, with a simple mechanical design. The phosphor appears to be quite rugged, with no degradation having appeared during several months of testing both in and out of vacuum. Tests have been made at visible and EUV (304 A) wavelengths of the following performance aspects: EUV spectral sensitivity, spatial resolution (both of components and of the system as a whole), noise, linearity, and dynamic range. An improved detector for the Coronal Diagnostic Spectrometer experiment on the Solar Heliospheric Observatory satellite is being presently designed.

Thompson, William T.↗

Near-infrared CCD observations of umbral dots

Umbral fine structure have been observed at 8500 A using a new CCD detector. Four frames with diffraction-limited seeing were obtained. Between 68 and 91 umbral dots with a brightness contrast greater than 2 percent were found in each frame, although no dots were found in the darkest part of the umbra. The intrinsic flux of the umbral dots varies widely, indicating that their intrinsic brightness does as well. The mean dot lifetime is estimated as 15 min, although some dots were observed to live more than 2 h. Some of the umbral dots are flowing into the umbra at speeds up to 0.5 km/s. These dots have higher than average contrast and are associated with penumbral grains.

Ewell, Malcolm W., Jr.↗