Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Modified Slow Tuner Design for Cavity 1 Inside LCLS II Cryomodules

Initial LCLS-II cryomodule testing at Fermilab showed microphonics on the furthest upstream cavity (number 1) at least factor 2 larger than on the rest of the cavities. Testing indicated that this was a difference in the mechanical support of cavity 1, not a local acoustic source. Further investigation pointed to the upstream beam-pipe of the cavity 1. The upstream cavity flange has a solid spool piece connection to the beamline gate valve unlike the other cavities, which all connect through bellows. The gate valve's weight is supported by sliding system (free in z-axis) connected to large diameter Helium gas return pipe. The tuner design was modified to transform interface between cavity#1 and gate valve. Arms of the tuner for cavity 1 were extended and became the support structure for gate valve, eliminating the connection to the helium return pipe. Modification of the tuner design and results in microphonics mitigations will be presented.

43 PARTICLE ACCELERATORS↗

Status of PIP-II 650 MHz Prototype Dressed Cavity Qualification

Low-beta and high-beta sections of PIP-II linac will use nine low-beta cryomodules with four cavities each and four high-beta cryomodules with six cavities each. These cavities will be produced and qualified in collaboration between Fermilab and the international partner labs. Prior to their installation into prototype cryomodules, several dressed cavities, which include jacketed cavities, high power couplers, and tuners, will be qualified in STC horizontal test bed at Fermilab. After qualification of bare β = 0.9 cavities at Fermilab, several pre-production β = 0.92 and β = 0.61 cavities have been and are being fabricated and qualified. Procurements have also been started for high power couplers and tuners. In this contribution we present the current status of prototype dressed cavity qualification for PIP-II.

43 PARTICLE ACCELERATORS↗

Cavity Qualification and Production Update for SNS-PPU Cryomodules at Jefferson Lab

The Proton Power Upgrade (PPU) project at Oak Ridge National Lab’s Spallation Neutron Source (SNS) currently being constructed will double the proton beam power capability from 1.4 to 2.8 MW by adding seven cryomodules, each containing four six-cell high-beta (β = 0.81) superconducting radio frequency cavities. Research Instruments, located in Germany, built and processed the cavities at the vendor site, including electropolishing as the final active chemistry step. Twenty-eight cavities for seven cryomodules and an additional four cavities for a spare cryomodules were delivered to Jefferson Lab and first qualification tests were completed on all cavities as received from the vendor. The performance largely exceeded the requirements on quality factor and accelerating gradient. Here we present the status of initial cavity qualification tests, rework on unqualified cavities and final cavity qualification with helium vessel prior to installation in cryomodules. In addition, an update on cryomodule production is presented.

Dhakal, P.↗

Test Result of 650 MHz, Beta 0.61 Single Cell Niobium Cavity

VECC has been involved in the design, analysis and development of 650 MHz, beta 0.61 (LB650), elliptical Superconducting RF linac cavity, as part of research and development activities on SRF cavities and associated technologies under Indian Institutions Fermilab Collaboration (IIFC). A single-cell niobium cavity has been indigenously designed and developed at VECC, with the help of Electron Beam Welding (EBW) facility at IUAC, New Delhi. Various measurements, processing and testing at 2K in Vertical Test Stand (VTS) of the single-cell cavity was carried out at ANL and Fermilab, USA, with active participation of VECC engineers. It achieved a maximum accelerating gradient(Eacc) of 34.5 MV/m with Quality Factor of 2·10⁹ and 30 MV/m with Quality Factor of 1.5·10¹⁰. This is probably the highest accelerating gradient achieved so far in the world for LB650 cavities. This paper describes the design, fabrication and measurement of the single cell niobium cavity. Cavity processing and test results of Vertical Test of the single-cell niobium cavity are also presented.

43 PARTICLE ACCELERATORS↗

RECENT RESULTS FROM Nb3Sn SINGLE CELL CAVITIES COATED AT JLAB

Because of superior superconducting properties (Tc ~ 18.3K, Hs h ~ 425 mT and ? ~ 3.1 meV) compared to niobium, Nb3Sn promise better RF performance (Q0 and Eacc) and/or higher operating temperature (2 K Vs 4.2 K) for SRF cavities. Nb3Sn-coated SRF cavities are produced routinely by depositing a few micron-thick Nb3Sn films inside of Nb cavities via tin vapor diffu-sion technique. Early results from Nb3Sn cavities coat-ed with this technique exhibited precipitous low field Q-slope, also known as Wuppertal slope. Several Nb3Sn single cell cavities coated at JLab appeared to exhibit similar Q-slope. RF testing of cavities and ma-terials study of witness samples were continuously used to modify the coating protocol. At best condition, we were able to produce Nb3Sn cavity with Q0 in ex-cess of ? 5×1010 at 2 K and ? 2×1010 at 4 K up the ac-celerating gradient of ~15 MV/m, without any signifi-cant Q-slope. In this presentation, we will discuss re-cent results from several Nb3Sn coated single-cell cavities linked with material studies of witness sam-ples, coating process modifications and the possible causative factors to Wuppertal slope.

Pudasaini, U.↗

New Design of SSR2 Spoke Cavity for PIP II SRF Linac

Superconducting SSR2 spoke cavities provide acceleration of the H- in PIP II SRF linac from 35 to 185 MeV. The RF and mechanical design of the SSR2 cavities has been completed and satisfies the technical requirements. However, our resent results of the high RF power tests of fully dressed SSR1 cavities show considerably strong multipacting (MP), which took significant time to process. On the other hand, the new results of the tests of balloon cavity showed significant mitigation of MP. In this paper we present the results of the improved design of the SSR2 cavity, based on the balloon cavity concept. The electromagnetic design is presented, including RF parameter optimization, MP simulations, field asymmetry analysis, High Order Mode (HOM) calculations. Mechanical analysis of the dressed cavity is presented also, which includes Lorentz Force Detuning (LFD) optimization, and reduction of the cavity resonance frequency sensitivity versus He pressure fluctuations. The design completely satisfies the PIP II technical requirements.

43 PARTICLE ACCELERATORS↗

Comparing the Effectiveness of Low Temperature Bake in EP and BCP Cavities

Electropolishing (EP) and buffered chemical polishing (BCP) are conventional surface preparation techniques for superconducting radiofrequency (SRF) cavities. Both EP and BCP treated SRF cavities display high field Q-slope (HFQS) which degrades performance at high gradients. While high gradient performance in EP cavities can be improved by introducing oxygen via a low temperature bake (LTB) of 120^{°}C by 48 hours, LTB does not consistently remove HFQS in BCP cavities. There is no consensus as to why LTB is not effective on BCP prepared cavities. We examine quench in EP, BCP, EP+LTB, and BCP+LTB treated 1.3 GHz single-cell Nb cavities by studying the heating behavior with field using a temperature mapping system. Cavity performance is correlated to characterizations of surface impurity profile obtained via time of flight secondary ion mass spectrometry studies. We observe a difference in near surface hydrogen concentration following BCP compared to EP that may suggest that the causes of quench in EP and BCP cavities are different.

43 PARTICLE ACCELERATORS↗

Higher order model power calculation of the 56 MHz SRF cavity

A 56 MHz superconducting RF cavity (SRF) is going to be installed in Relativistic Heavy Ion Collider (RHIC) ring for the luminosity upgrade of the RHIC operation. Currently, it is being designed and prototype-tested as an Accelerator Improvement Project (AIP). The 56 MHz SRF cavity will be turned on at store of the RHIC operation. When the beam frequencies overlap or come close to the cavity HOM frequencies, the HOMs are excited in the cavity, which may lead to beam instability. Since the shunt impedance of the superconducting cavity tends to be higher than that of the copper cavity, the voltage developed in the cavity due to the HOM excitation can in principle be large. Therefore, suppressing the HOMs is an important task for the 56 MHz SRF cavity. To pursue the task, understanding the frequencies, Q factors and shunt impedances for the HOMs is prerequisite. Based on the given HOM characteristic, the HOM power can be calculated. The simulation results from the available programs as well as the prototype measurement results are used for the analysis.

43 PARTICLE ACCELERATORS↗

Geometric Optimization of the 56MHz SRF Cavity and its Frequency Table

It is essential to know the frequency of a Superconducting Radio Frequency (SRF) cavity at its “just being fabricated” stage because frequency is the key parameter in constructing the cavity. In this paper, we report our work on assessing it. We can estimate the frequency change from stage to stage theoretically and/or by simulation. At the operating stage, the frequency can be calculated accurately, and, from this value, we obtain the frequencies at other stages. They are listed in a table that serves to check the processes from stage to stage. Equally important is optimizing the geometric shape of the SRF cavity so that the peak electric-field and peak magnetic-field are as low as possible. It is particularly desirable in the 56MHz SRF cavity of RHIC to maximize the frequency sensitivity of the slow tuner. After undertaking such optimization, our resultant peak electric-field is only 35.3MV/m, and the peak magnetic-field is 840G at 2MV of voltage across the cavity gap. To quench superconductivity in an SRF cavity, it is reported that the limit of the peak magnetic-field is 1800G [1], and that of the peak electric-field is more than 100MV/m for a SRF cavity [2]. Naturally, for the complex geometry of this cavity (including numerous electron beam welds) and 4.2K operations we do not expect record field performance, but a useful 2 MV gap voltage is reasonable to expect. Our simulations employed the codes Superfish and Microwave Studio.

43 PARTICLE ACCELERATORS↗

Conduction Cooling of a Niobium SRF Cavity Using a Cryocooler

Superconducting Radio Frequency (SRF) cavities are the primary choice for accelerating charged particles in high-energy research accelerators. Institutions like Fermilab use SRF cavities because they enable significantly higher gradients and quality factors than normal-conducting RF cavities and DC voltage cavities. To cool the SRF cavities to low temperatures (typically around 2 K), liquid helium refrigerators are used. Producing and maintaining the necessary liquid helium requires large, elaborate cryogenic plants involving dewars, compressors, expansion engines, and recyclers. The cost, complexity, and space required for such plants is part of the reason that industry has not yet adopted SRF-based accelerators. At the Illinois Accelerator Research Center (IARC) at Fermilab, our team seeks to make SRF technology accessible not only to large research accelerators, but to industry as well. If we eliminate the complexity associated with liquid helium plants, SRF-based industrial accelerators may finally become a reality. One way to do this is to eliminate the use of liquid helium baths altogether and develop a brand-new cooling technique for SRF cavities: conduction cooling using a cryocooler. Recent advances in SRF technology have made it possible to operate SRF cavities at 4 K, a temperature easily achievable using commercial cryocoolers. Our IARC team is taking advantage of this technology to cool SRF cavities.

43 PARTICLE ACCELERATORS↗

Crab cavity requirements for the Jefferson Lab Electron-Ion Collider

An Electron-Ion Collider (EIC) has been proposed to be the next large facility to explore the dynamics of quarks and gluons inside nuclei. A conceptual design for a Jefferson Lab Electron-Ion Collider (JLEIC) is being developed. It is based on the CEBAF 12 GeV machine as a full energy electron beam injector. Two crucial requirements of JLEIC are high luminosity in the 10 34 cm -2 s -1 range, and full acceptance detection of particles. The full acceptance requirement relies on having the beams collide at a relatively large crossing angle of 50 mrad. Such a large crossing angle, however, can reduce the luminosity by as much as an order of magnitude. One way to compensate for geometric luminosity loss due to the beam crossing angle is using crab cavities. Crab cavities are superconducting radio-frequency structures optimized to produce a transverse force that 'tilts' the beam bunches in such a way that a head-on collision is restored at the collision point, thus restoring the luminosity. A second set of crab cavities is placed downstream of the collision point and is used to cancel the initial bunch tilt, ideally suppressing any crab-induced effects anywhere else in the rings. In this dissertation, we study the dynamics of JLEIC beams with a bunch crabbing scheme using particle tracking simulations. We first evaluate the beam stability when crab cavities are included in the collider rings and then use this stable model to study effects of crab cavity multipoles and RF noise. We also study the role of crab cavity higher-order modes (HOM) in driving coupled-bunch instability and identify dangerous HOM which need to be damped. A specific crab cavity for JLEIC has not yet been selected. It is the purpose of this dissertation to provide general requirements and tolerances to make future crab cavity designs compatible with JLEIC.

Sosa Guitron, Salvador↗

AASC Coated Cavities

The price of niobium is a significant part of the cost of superconducting RF cavity production. One route to significant cost reduction is to use cavities that have a thin layer of niobium deposited on a less expensive substrate. However, to date, all attempts to use thin films of niobium in superconducting RF cavities have resulted in cavity performance that does not meet the requirements for modern linear accelerators. Fermilab will provide two (2) cavities to AASC. AASC will coat the two (2) cavities with niobium using its high-purity deposition method. AASC will return the coated cavities to Fermilab for Quality Assurance (QA) testing. If the coatings pass preliminary QA tests performed at Fermilab, they will be subjected to RF testing at Fermilab and their performance will be evaluated relative to solid niobium cavities.

43 PARTICLE ACCELERATORS↗

Vertical Testing and Preparation of an Acid-Free Electropolished SRF Cavity

The project team proposes to build upon recent work to develop a robust, high throughput vertical Final Electropolishing process for SRF cavities, based on an Acid-Free Bipolar Electropolishing process, to replace conventional electropolishing for single and nine-cell cavities at the alpha/beta scale. The development of Bipolar EP for final surface finishing step will enable a manufacturing process that controls costs and reduces the environmental and health hazards associated with using acid solutions. The proposed outcome is a cost effective and robust process for final electropolishing of niobium SRF cavities. The market size for SRF cavities for the International Linear Collider is ~16,000 cavities, with applicability to many other cavity configurations and applications. Other markets for Acid-Free Bipolar EP include niobium-alloys that are hypoallergenic and commonly alloyed with titanium and zirconium to make implantable medical devices and require HF acid for polishing. Elimination of acids for electropolishing of medical implants is an important need and represents a strong commercial opportunity with a US market of ~$45B by 2014. Under this CRADA, Fermilab provided a 1.3 GHz RF cavity to Faraday Technology to use for acid-free electropolishing studies. The original scope of work also provided for up to two tests of the electropolished cavity in Fermilab’s Vertical Test Stand (VTS).

43 PARTICLE ACCELERATORS↗

Studying Qubit Interactions with Multimode Cavities Using QuTiP

The project uses QuTiP, a quantum computing framework [1], to simulate interactions between two-qubits coupled with each other via three resonators. The main aim of this project is to build a machinery of techniques to understand complex qubit-cavity interactions using QuTiP’s functionalities. The system simulated mimics the one constructed by McKay et. al. [2] (M15) and the results of the simulations closely agree with M15’s experimental results. The effect of the coupling strength between the qubits and the cavities is studied. It was observed that stronger couplings generated larger separations between the eigen-modes. Studies involving resonance were used to construct the iSWAP gate, a universal quantum logic gate. This study showed the importance of external thermal losses due to cavity dissipation, and qubit decay and dephasing. The Landau-Zener model was tested for the case of multiple crossing; the model motivated the comparison of three scenarios where the 2 qubits were coupled via: 1 cavity, 3 cavities, and 6 cavities. The study concluded that having multiple modes, which is a consequence of having multiple cavities, is advantageous for transferring energy from the qubit to the cavity. Finally, the ac-Stark shift was measured in the system and it’s dynamics showed excellent agreement with the experimental results obtained by M15.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving Nb3Sn Cavity Performance Using Centrifugal Barrel Polishing

Nb3Sn superconducting radiofrequency (SRF) cavities have been an ongoing research topic for many years motivated by the potential for higher accelerating gradients and quality factors compared to niobium SRF cavities. The highest performing Nb3Sn cavities are manufactured using tin vapor-diffusion coating, which creates a Nb3Sn film with a surface roughness of around 100-200 nm. This is thought to be one of the limiting factors for the accelerating gradient of Nb3Sn cavities due to enhancement of magnetic field near sharp surface features. To smooth Nb3Sn SRF cavities, we have developed a mechanical polishing procedure which uses centrifugal barrel polishing to smooth the surface followed by a secondary tin coating step to repair the surface. We show that the accelerating field of a Nb3Sn SRF cavity is improved by applying this procedure. We also investigate the quench mechanism of the polished cavity by utilizing temperature mapping to measure which regions of the cavity e xperience heating during RF operation. We then cut samples from these regions and analyze the film microstructure and chemical composition in 3D using EDS and EBSD measurements together with a focused ion-beam (FIB) tomography technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

Robotic Assembly of SRF Cavity Pair

Superconducting Radio Frequency (SRF) cavities for particle accelerators require tight tolerances, ultrahigh vacuum, and strict cleanliness during assembly. As in the semiconductor industry, defects such as particles and residues are deleterious to performance, possibly rendering a cavity unfit for use. This problem is addressed primarily through cleanroom assembly during sensitive steps and rigorous chemical processing to prevent and remove such defects. Human workers are often the largest source of contamination, even with proper gowning and practices. The semiconductor industry has long integrated robots in cleanroom operation, but this has not occurred for SRF cavity production; SRF cavities, unlike wafers, are complex shapes, require more hands-on mechanical assembly, and are low-volume production items. At Jefferson Laboratory, a co-operative robot (cobot) has been setup to overcome these problems. Cobots are safe for use alongside human workers and can integrate new tools such as a 3D camera part detection and gripper for item manipulation. Therefore, cobots represent a promising avenue for reducing particulate generated during a variety of assembly tasks. A mockup of a cavity pair and coupler was setup and the cobot programmed to automatically pick up the coupler and place on the mating cavity flange. Particle counting methods were setup to measure human vs cobot assembly particulate generation inside a cavity mockup. Other potential uses will be discussed for further improving SRF cavity assembly steps, where a cobot can replace or assist a human operator, and what potential gains are expected.

Duzik, Adam [Thomas Jefferson National Accelerator↗

Reverse Current Model for Coronal Mass Ejection Cavity Formation

In this work, we present a new model for explaining the three-part structure of coronal mass ejections (CMEs). The model proposes that the cavity in a CME forms because a rising electric current in the core prominence induces an oppositely directed electric current in the background plasma; this eddy current is required to satisfy the frozen-in magnetic flux condition in the background plasma. The magnetic force between the inner-core electric current and the oppositely directed induced eddy current propels the background plasma away from the core, creating a cavity and a density pileup at the cavity edge. The cavity radius saturates when an inward restoring force from magnetic and hydrodynamic pressure in the region outside the cavity edge balances the outward magnetic force. The model is supported by (i) laboratory experiments showing the development of a cavity as a result of the repulsion of an induced reverse current by a rising inner-core flux-rope current, (ii) 3D numerical magnetohydrodynamic (MHD) simulations that reproduce the laboratory experiments in quantitative detail, and (iii) an analytic model that describes cavity formation as a result of the plasma containing the induced reverse current being repelled from the inner core. This analytic model offers broad applicability because the predicted cavity widths are relatively independent of both the current injection mechanism and the injection timescale.

79 ASTRONOMY AND ASTROPHYSICS↗