Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAT SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Lung Texture in Serial Thoracic Computed Tomography Scans: Correlation of Radiomics-based Features With Radiation Therapy Dose and Radiation Pneumonitis Development

Purpose: To assess the relationship between radiation dose and change in a set of mathematical intensity- and texture-based features and to determine the ability of texture analysis to identify patients who develop radiation pneumonitis (RP). Methods and Materials: A total of 106 patients who received radiation therapy (RT) for esophageal cancer were retrospectively identified under institutional review board approval. For each patient, diagnostic computed tomography (CT) scans were acquired before (0-168 days) and after (5-120 days) RT, and a treatment planning CT scan with an associated dose map was obtained. 32- × 32-pixel regions of interest (ROIs) were randomly identified in the lungs of each pre-RT scan. ROIs were subsequently mapped to the post-RT scan and the planning scan dose map by using deformable image registration. The changes in 20 feature values (ΔFV) between pre- and post-RT scan ROIs were calculated. Regression modeling and analysis of variance were used to test the relationships between ΔFV, mean ROI dose, and development of grade ≥2 RP. Area under the receiver operating characteristic curve (AUC) was calculated to determine each feature's ability to distinguish between patients with and those without RP. A classifier was constructed to determine whether 2- or 3-feature combinations could improve RP distinction. Results: For all 20 features, a significant ΔFV was observed with increasing radiation dose. Twelve features changed significantly for patients with RP. Individual texture features could discriminate between patients with and those without RP with moderate performance (AUCs from 0.49 to 0.78). Using multiple features in a classifier, AUC increased significantly (0.59-0.84). Conclusions: A relationship between dose and change in a set of image-based features was observed. For 12 features, ΔFV was significantly related to RP development. This study demonstrated the ability of radiomics to provide a quantitative, individualized measurement of patient lung tissue reaction to RT and assess RP development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inclusion of the treatment couch in portal dose image prediction for high precision EPID dosimetry

Purpose: When comparing predicted portal dose images (PDIs) to PDIs acquired by an EPID during treatment delivery, differences are often observed. These differences may be partially attributed to beam attenuation by parts of the treatment couch not taken into account in the PDI prediction. In order to improve the agreement, a model for the treatment couch was derived and included in the PDI prediction. Methods: A CT scan was used to model the couch top. The model for the couch top base was derived by iteratively matching the predicted and measured PDIs for gantry angles of 0 deg., 45 deg., and 90 deg. For PDI prediction, the modeled treatment couch was added to the CT scan of a patient or phantom by using the recorded couch positions from the record and verify system. To validate the couch model, PDI measurements were performed for a range of couch positions and gantry angles, both with and without an anatomical phantom in the beam. Results: After including the couch model in the PDI prediction for beams passing through the couch without phantom, the mean local dose differences between measured and predicted PDIs were reduced from up to 5.5% to less than 1.0% at each gantry angle. Similar results were obtained for measurements with a lung phantom on the couch. Although the couch model was originally derived by using a 6 MV photon beam, the results showed that it is also applicable for a 10 MV beam. Conclusions: A model of the treatment couch was derived and included in the PDI prediction, yielding a substantially improved agreement between measured and predicted PDIs, which makes interpretation of the observed deviations more straightforward.

60 APPLIED LIFE SCIENCES↗

Model-based versus specific dosimetry in diagnostic context: Comparison of three dosimetric approaches

Purpose: The dosimetric assessment of novel radiotracers represents a legal requirement in most countries. While the techniques for the computation of internal absorbed dose in a therapeutic context have made huge progresses in recent years, in a diagnostic scenario the absorbed dose is usually extracted from model-based lookup tables, most often derived from International Commission on Radiological Protection (ICRP) or Medical Internal Radiation Dose (MIRD) Committee models. The level of approximation introduced by these models may impact the resulting dosimetry. The aim of this work is to establish whether a more refined approach to dosimetry can be implemented in nuclear medicine diagnostics, by analyzing a specific case. Methods: The authors calculated absorbed doses to various organs in six healthy volunteers administered with flutemetamol ({sup 18}F) injection. Each patient underwent from 8 to 10 whole body 3D PET/CT scans. This dataset was analyzed using a Monte Carlo (MC) application developed in-house using the toolkit GATE that is capable to take into account patient-specific anatomy and radiotracer distribution at the voxel level. They compared the absorbed doses obtained with GATE to those calculated with two commercially available software: OLINDA/EXM and STRATOS implementing a dose voxel kernel convolution approach. Results: Absorbed doses calculated with GATE were higher than those calculated with OLINDA. The average ratio between GATE absorbed doses and OLINDA’s was 1.38 ± 0.34 σ (from 0.93 to 2.23). The discrepancy was particularly high for the thyroid, with an average GATE/OLINDA ratio of 1.97 ± 0.83 σ for the six patients. Differences between STRATOS and GATE were found to be higher. The average ratio between GATE and STRATOS absorbed doses was 2.51 ± 1.21 σ (from 1.09 to 6.06). Conclusions: This study demonstrates how the choice of the absorbed dose calculation algorithm may introduce a bias when gamma radiations are of importance, as is the case in nuclear medicine diagnostics.

60 APPLIED LIFE SCIENCES↗

Implications of Respiratory Motion as Measured by Four-Dimensional Computed Tomography for Radiation Treatment Planning of Esophageal Cancer

Purpose: To evaluate the respiratory motion of primary esophageal cancers and pathologic celiac-region lymph nodes using time-resolved four-dimensional computed tomography (4D CT). Methods and Materials: Respiration-synchronized 4D CT scans were obtained to quantify the motion of primary tumors located in the proximal, mid-, or distal thoracic esophagus, as well as any involved celiac-region lymph nodes. Respiratory motion was measured in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions and was analyzed for correlation with anatomic location. Recommended margin expansions were determined for both primary and nodal targets. Results: Thirty patients underwent 4D CT scans at Massachusetts General Hospital for planned curative treatment of esophageal cancer. Measurements of respiratory tumor motion were obtained for 1 proximal, 4 mid-, and 25 distal esophageal tumors, as well as 12 involved celiac-region lymph nodes. The mean (SD) peak-to-peak displacements of all primary tumors in the SI, AP, and LR dimensions were 0.80 (0.45) cm, 0.28 (0.20) cm, and 0.22 (0.23) cm, respectively. Distal tumors were found to have significantly greater SI and AP motion than proximal or mid-esophageal tumors. The mean (SD) SI, AP, and LR peak-to-peak displacements of the celiac-region lymph nodes were 0.92 (0.56) cm, 0.46 (0.27) cm, and 0.19 (0.26) cm, respectively. Conclusions: Margins of 1.5 cm SI, 0.75 cm AP, and 0.75 cm LR would account for respiratory tumor motion of >95% of esophageal primary tumors in the dataset. All celiac-region lymph nodes would be adequately covered with SI, AP, and LR margins of 2.25 cm, 1.0 cm, and 0.75 cm, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in the spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical and improved its performance. In addition, this is a very active area of research and further improvements are expected through further technological improvements. Learning Objectives: Basic principles of multi-energy CT Current implementations of mutli-energy CT Data and image analysis methods in multi-energy CT Current clinical applications of dual energy CT5. recent innovations and anticipated advances in multi-energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-220: Validation of Hounsfield Unit-To-Stopping Power Ratio Calibration Used for Dose Calculation in Proton Radiotherapy

Purpose: To validate the stoichiometric calibration of the Hounsfield Unit (HU) to Stopping Power Ratio (SPR) calibration used to commission a commercial treatment planning system (TPS) for proton radiotherapy dose calculation. Methods and Materials: The water equivalent thickness (WET) of several individual pig tissues (lung, fat, muscle, liver, intestine, rib, femur), mixed tissue samples (muscle/rib, ice/femur, rib/air cavity/muscle), and an intact pig head were measured with a multi-layer ionization chamber (MLIC). A CT scan of each sample was obtained and imported into a commercial TPS. The WET calculated by the TPS for each tissue sample was compared to the measured WET value to determine the accuracy of the HU-to-SPR calibration curve used by the TPS to calculate dose. Results: The WET values calculated by the TPS showed good agreement (< 2.0%) with the measured values for bone and all soft tissues except fat (3.1% difference). For the mixed tissue samples and the intact pig head measurements, the difference in the TPS and measured WET values all agreed to within 3.5%. In addition, SPR values were calculated from the measured WET of each tissue, and compared to SPR values of reference tissues from ICRU 46 used to generate the HU-to-SPR calibration for the TPS. Conclusion: For clinical scenarios where the beam passes through multiple tissue types and its path is dominated by soft tissues, we believe using an uncertainty of 3.5% of the planned beam range is acceptable to account for uncertainties in the TPS WET determination.

60 APPLIED LIFE SCIENCES↗

Irreversible Electroporation in a Swine Lung Model

Purpose: This study was designed to evaluate the safety and tissue effects of IRE in a swine lung model. Methods: This study was approved by the institutional animal care committee. Nine anesthetized domestic swine underwent 15 percutaneous irreversible electroporation (IRE) lesion creations (6 with bipolar and 3 with 3-4 monopolar electrodes) under fluoroscopic guidance and with pancuronium neuromuscular blockade and EKG gating. IRE electrodes were placed into the central and middle third of the right mid and lower lobes in all animals. Postprocedure PA and lateral chest radiographs were obtained to evaluate for pneumothorax. Three animals were sacrificed at 2 weeks and six at 4 weeks. Animals underwent high-resolution CT scanning and PA and lateral radiographs 1 h before sacrifice. The treated lungs were removed en bloc, perfused with formalin, and sectioned. Gross pathologic and microscopic changes after standard hematoxylin and eosin staining were analyzed within the areas of IRE lesion creation. Results: No significant adverse events were identified. CT showed focal areas of spiculated high density ranging in greatest diameter from 1.1-2.2 cm. On gross inspection of the sectioned lung, focal areas of tan discoloration and increased density were palpated in the areas of IRE. Histological analysis revealed focal areas of diffuse alveolar damage with fibrosis and inflammatory infiltration that respected the boundaries of the interlobular septae. No pathological difference could be discerned between the 2- and 4-week time points. The bronchioles and blood vessels within the areas of IRE were intact and did not show signs of tissue injury. Conclusion: IRE creates focal areas of diffuse alveolar damage without creating damage to the bronchioles or blood vessels. Short-term safety in a swine model appears to be satisfactory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks

Purpose: To prospectively compare setup error in standard thermoplastic masks and skin-sparing masks (SSMs) modified with low neck cutouts for head-and-neck intensity-modulated radiation therapy (IMRT) patients. Methods and Materials: Twenty head-and-neck IMRT patients were randomized to be treated in a standard mask (SM) or SSM. Cone-beam computed tomography (CBCT) scans, acquired daily after both initial setup and any repositioning, were used for initial and residual interfraction evaluation, respectively. Weekly, post-IMRT CBCT scans were acquired for intrafraction setup evaluation. The population random (sigma) and systematic (SIGMA) errors were compared for SMs and SSMs. Skin toxicity was recorded weekly by use of Radiation Therapy Oncology Group criteria. Results: We evaluated 762 CBCT scans in 11 patients randomized to the SM and 9 to the SSM. Initial interfraction sigma was 1.6 mm or less or 1.1 deg. or less for SM and 2.0 mm or less and 0.8 deg. for SSM. Initial interfraction SIGMA was 1.0 mm or less or 1.4 deg. or less for SM and 1.1 mm or less or 0.9 deg. or less for SSM. These errors were reduced before IMRT with CBCT image guidance with no significant differences in residual interfraction or intrafraction uncertainties between SMs and SSMs. Intrafraction sigma and SIGMA were less than 1 mm and less than 1 deg. for both masks. Less severe skin reactions were observed in the cutout regions of the SSM compared with non-cutout regions. Conclusions: Interfraction and intrafraction setup error is not significantly different for SSMs and conventional masks in head-and-neck radiation therapy. Mask cutouts should be considered for these patients in an effort to reduce skin toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Intrafraction and Residual Interfraction Effect on Prostate Proton Pencil Beam Scanning

Purpose: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. Methods and Materials: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the “true” dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect. Results: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D{sub 99} (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D{sub 99} was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant. Conclusions: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a clinically acceptable level. One-field-per-day SFUD delivered twice is as robust as the bilateral SFUD plan treated daily over the course of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her original kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive dental artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-18A-01: Preliminary Results of a Prototype Quality Control Process for Spectral CT

Purpose: A prototype quality control (QC) phantom and analysis process has been designed specifically to monitor dual-energy CT and address the current lack of quantitative oversight of the spectral capabilities of these scanners. Methods: A prototype solid water phantom was designed with multiple material inserts, and to support both head and body protocols. Inserts included tissue equivalent and material rods (iodine, iron, calcium) at various concentrations. The oval body phantom, measuring 30cm×40cm×15cm, was scanned using four dual-energy protocols with CTDIvol ranges of 19.6–62mGy (0.516 pitch) and 10.3–32.5mGy (0.984 pitch), and rotation times ranging from 0.5-1sec. The circular head phantom, measuring 22cm in diameter by 15cm, was scanned using three dual-energy protocols with CTDIvol ranges of 67–132.6mGy (0.531 pitch) and 36.7–72.7mGy (0.969 pitch), and rotation times ranging from 0.5–0.9sec. All images were reconstructed at 50, 70, 110 and 140 keV, and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy and stability of monoenergetic reconstructions. The phantom was scanned twice on ten GE 750HD CT scanners to evaluate inter-scanner agreement, as well as ten times on a single scanner over a oneweek period to evaluate intra-scanner repeatability. Results: Preliminary analysis revealed consistent (inter- and intra-scanner) iodine quantification accuracy within 10% was only achieved for protocols in the upper half of dose levels assessed when grouped by pitch. Although all scanners undergo rigorous daily single-energy QC, iodine quantification accuracy from one scanner unexpectedly deviated from the other nine substantially. In general, inter-scanner agreement and intra-scanner repeatability varied with dose, rotation time and reconstructed keV. Conclusion: Preliminary results indicate the need for a dual-energy QC process to ensure inter-scanner agreement and intra-scanner repeatability. In particular, iodine quantification accuracy within 10% may not be achievable using lower dose techniques. Future plans include longer term dual-energy CT QC data collection. In-kind financial support was provided by GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Potential for Higher Treatment Failure in Obese Patients: Correlation of Elevated Body Mass Index and Increased Daily Prostate Deviations From the Radiation Beam Isocenters in an Analysis of 1,465 Computed Tomographic Images

Purpose: Recent clinical outcome studies on prostate cancer have reported the influence of patient's obesity on the biochemical failure rates after various treatment modalities. In this study, we investigated the effect of patient's physical characteristics on prostate shift in external beam radiotherapy (EBRT) and hypothesized that there maybe a correlation between patient physique and tumor shift. Methods and Materials: A retrospective analysis was performed using data for 117 patients who received image-guided radiation therapy (IGRT) for prostate cancer between January 2005 and April 2007. A total of 1,465 CT scans were analyzed. The standard deviations (SDs) of prostate shifts for all patients, along with patient weight, body mass index (BMI), and subcutaneous adipose-tissue thickness (SAT), were determined. Spearman rank correlation analysis was performed. Results: Of the 117 patients, 26.5% were considered normal weight, 48.7% were overweight, 17.9% were mildly obese, and 6.9% were moderately to severely obese. Notably 1.3%, 1.5%, 2.0%, and 21.2% of the respective shifts were greater than 10 mm in the left-right (LR) direction for the four patient groups, whereas in the anterior-posterior direction the shifts are 18.2%, 12.6%, 6.7%, and 21.0%, respectively. Strong correlations were observed between SAT, BMI, patient weight, and SDs of daily shifts in the LR direction (p < 0.01). Conclusions: The strong correlation between obesity and shift indicates that without image-guided radiation therapy, the target volume (prostate with or without seminal vesicles) may not receive the intended dose for patients who are moderate to severely obese. This may explain the higher recurrence rate with conventional external beam radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noninvasive Evaluation of Microscopic Tumor Extensions Using Standardized Uptake Value and Metabolic Tumor Volume in Non-Small-Cell Lung Cancer

Purpose: To prospectively evaluate whether maximal microscopic extensions (MEmax) correlate with maximal standardized uptake value (SUVmax) and metabolic tumor volume (MTV) at 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) images in non-small-cell lung cancer (NSCLC). Methods and Materials: Thirty-nine patients with Stage I-IIIA NSCLC underwent surgery after FDG-PET/CT scanning. SUVmax and MTV were calculated on the PET/CT images. The maximum linear distance from the tumor margin to the farthest extent of the tumor in every dimension was measured at the tumor section. The correlations among MEmax, SUVmax, MTV and other clinical pathologic parameters were analyzed. Results: MEmax for all patients had a significant correlation with SUVmax (r = 0.777, p = 0.008) and MTV (r = 0.724, p < 0.001). When expressed in terms of the probability of covering ME with respect to a given margin, we suggested that margins of 1.93 mm, 3.90 mm, and 9.60 mm for SUVmax {<=}5, 5-10, and >10 added to the gross tumor volume would be adequate to cover 95% of ME. Conclusions: This study demonstrated that tumors with high SUVmax and MTV have more MEmax and would therefore require more margin expansion from gross tumor volume to clinical target volume. FDG-PET/CT, especially for SUVmax, is promising and effective and merits additional study in noninvasive delimiting of the clinical target volume margin for NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methods was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of Pulmonary Nodules on Chest Computed Tomography and Risk of Recurrence in Stage IV Wilms Tumor

Purpose: Chest computed tomography (CT) is currently accepted as the main modality for initial disease staging and response assessment in Wilms tumor (WT). However, there is great variability in the number and size of lung metastases at the time of diagnosis and after induction chemotherapy. There is a lack of clinical evidence as to how this variability in tumor burden affects choice of therapy and disease outcome. This study sought to evaluate a previously proposed lung metastases risk stratification system based on CT findings and clinical outcomes in stage IV WT patients. Methods and Materials: Thirty-five pediatric patients with a diagnosis of stage IV WT with evaluable pre- and postdiagnosis CT scans between 1997 and 2012 were included in the analysis. Patients were divided into low-, intermediate-, and high-risk categories based on the size and number of pulmonary metastases before and after 6 weeks of chemotherapy. Association of the lung risk groups with lung recurrence-free survival and overall survival at each time point was analyzed with relevant covariates. Results: Risk group distribution both at diagnosis and after induction chemotherapy was not influenced by tumor histology. Initial risk grouping suggested an association with disease-free survival at 5 years (P=.074); however, the most significant correlation was with postinduction chemotherapy disease status (P=.027). In patients with an intermediate or high burden of disease after 6 weeks of chemotherapy, despite receiving whole-lung and boost irradiation, survival outcomes were poorer. Conclusions: Pulmonary tumor burden in stage IV WT on chest CT can predict disease outcome. Patients with intermediate- or low-risk disease, especially after induction therapy, have a higher risk for recurrence. After prospective validation, this method may become a valuable tool in adaptation of therapy to improve outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of 4DCT to Reduce Lung Dose: A Dosimetric Analysis

Dosimetric studies on respiratory movement suggest several advantages toward the use of 4-dimensional computed tomography (4DCT) in radiation treatment planning. 4DCT is a method to obtain a series of CT scans each representing a different respiratory phase. The use of 4DCT has provided substantial information on tumor movement in the lung, allowing for the creation of custom planning margins explicitly including respiratory motion. These custom motion margins may result in an increase in the amount of normal lung in the field; however, it is believed less normal lung is irradiated than if generic motion margins were used. Clinical data regarding dose to normal lung by using 4DCT remain rather limited. Thus, a study presenting figures on the change in normal lung dose between planned free breathing CT and 4DCT cases would be useful to the dosimetry community. We have generated plans comparing fast spiral CT and 4DCT in regard to tumor coverage and the resulting dose to normal lung for the clinical target volume (CTV) and planning target volume (PTV) expansions used at our institution. These data were analyzed for free breathing and 4D plans of 6 lung cancer patients using intensity modulated radiation therapy (IMRT). We compared doses to normal lung tissue between free breathing and 4DCT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments

Treatment plans are usually designed, optimized, and evaluated based on the total 3D dose distribution, motivating a total 3D dose verification. The purpose of this study was to develop a 2D transmission-dosimetry method using an electronic portal imaging device (EPID) into a simple 3D method that provides 3D dose information. In the new method, the dose is reconstructed within the patient volume in multiple planes parallel to the EPID for each gantry angle. By summing the 3D dose grids of all beams, the 3D dose distribution for the total treatment fraction is obtained. The algorithm uses patient contours from the planning CT scan but does not include tissue inhomogeneity corrections. The 3D EPID dosimetry method was tested for IMRT fractions of a prostate, a rectum, and a head-and-neck cancer patient. Planned and in vivo-measured dose distributions were within 2% at the dose prescription point. Within the 50% isodose surface of the prescribed dose, at least 97% of points were in agreement, evaluated with a 3D {gamma} method with criteria of 3% of the prescribed dose and 0.3 cm. Full 3D dose reconstruction on a 0.1x0.1x0.1 cm{sup 3} grid and 3D {gamma} evaluation took less than 15 min for one fraction on a standard PC. The method allows in vivo determination of 3D dose-volume parameters that are common in clinical practice. The authors conclude that their EPID dosimetry method is an accurate and fast tool for in vivo dose verification of IMRT plans in 3D. Their approach is independent of the treatment planning system and provides a practical safety net for radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional radiogenic lethal cancer incidents. According to the decision model calculations, the use of CT is more favorable over the use of radiography alone or radiography with CT by a factor of 13, for low risk 20 yr old patients, to a factor of 23, for high risk patients younger than 80 yr old. The radiography/CT imaging strategy slightly outperforms plain radiography for high and moderate risk patients. Regardless of the patient age, sex, and fracture risk, the higher diagnostic accuracy obtained by the CT examination counterbalances the increase in dose compared to plain radiography or radiography followed by CT only for positive radiographs and renders CT utilization justified and the radiographic screening redundant.

61 RADIATION PROTECTION AND DOSIMETRY↗