Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building automation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗

A Semi‐Automated, High‐Throughput Approach for the Synthesis and Identification of Highly Photo‐Cytotoxic Iridium Complexes

Abstract The discovery of new compounds with pharmacological properties is usually a lengthy, laborious and expensive process. Thus, there is increasing interest in developing workflows that allow for the rapid synthesis and evaluation of libraries of compounds with the aim of identifying leads for further drug development. Herein, we apply combinatorial synthesis to build a library of 90 iridium(III) complexes (81 of which are new) over two synthesise‐and‐test cycles, with the aim of identifying potential agents for photodynamic therapy. We demonstrate the power of this approach by identifying highly active complexes that are well‐tolerated in the dark but display very low nM phototoxicity against cancer cells. To build a detailed structure–activity relationship for this class of compounds we have used density functional theory (DFT) calculations to determine some key electronic parameters and study correlations with the experimental data. Finally, we present an optimised semi‐automated synthesise‐and‐test protocol to obtain multiplex data within 72 hours.

Kench, Timothy↗

A Semi‐Automated, High‐Throughput Approach for the Synthesis and Identification of Highly Photo‐Cytotoxic Iridium Complexes

Abstract The discovery of new compounds with pharmacological properties is usually a lengthy, laborious and expensive process. Thus, there is increasing interest in developing workflows that allow for the rapid synthesis and evaluation of libraries of compounds with the aim of identifying leads for further drug development. Herein, we apply combinatorial synthesis to build a library of 90 iridium(III) complexes (81 of which are new) over two synthesise‐and‐test cycles, with the aim of identifying potential agents for photodynamic therapy. We demonstrate the power of this approach by identifying highly active complexes that are well‐tolerated in the dark but display very low nM phototoxicity against cancer cells. To build a detailed structure–activity relationship for this class of compounds we have used density functional theory (DFT) calculations to determine some key electronic parameters and study correlations with the experimental data. Finally, we present an optimised semi‐automated synthesise‐and‐test protocol to obtain multiplex data within 72 hours.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Fidelity Accelerated Design of High-performance Electrochemical Systems

Large-scale electrification is vital to addressing the climate crisis, but several scientific and technological challenges remain to fully electrify both the chemical industry and transportation. In both of these areas, new electrochemical materials will be critical, but their development currently relies heavily on human-time-intensive experimental trial and error and computationally expensive first-principles, meso-scale and continuum simulations. To accelerate this process, our team has developed the AutoMat platform. AutoMat can accelerate development of new electrochemical materials along two avenues: first, automated input generation and management of simulations at multiple lengthscales as well as “handoff” of outputs from one lengthscale as inputs to the next; and second, replacement of the most computationally intensive simulation processes with machine-learned surrogate models. The crux of our team’s effort was not “reinventing the wheel” by developing entirely new techniques, but rather building a “superhighway” that allows existing state-of-the-art techniques to run faster and more smoothly than before. AutoMat can utilize tools spanning from first-principles quantum chemistry computations to automated robotic experimentation, and is driven by design space search techniques to reduce the number of iterations through the full simulation loop by rapidly targeting promising regions of design spaces such as single-atom alloy catalysts or blends of liquid electrolytes.

25 ENERGY STORAGE↗

FAIR to WISE (F2W) v1.0.0

FAIR to WISE (F2W) is an iterative, large-language model (LLM) driven pipeline that turns unstructured research PDFs into structured, queryable knowledge graphs (KGs). Core features include schema-driven extraction to a LinkML model; full provenance capture; ontology-grounded enrichment (e.g., chemical validation and ChEBI lookup); graph construction to JSON-LD with stable IDs; and KG-RAG question answering with evidence-aware retrieval. The system is engineered for reproducibility and accessibility (open-source Ollama models, temperature=0, NVTX/Nsight profiling) with robust QA (relation verification, deduplication, and deterministic outputs). Primary uses are literature-to-KG automation, knowledge-grounded Q&A, and experimental steering support. We demonstrate the approach in organic photovoltaics, where the pipeline ingests papers, builds a domain KG, and evaluates answers against expert competency questions to guide experimental planning and interpretation. Compared with off-the-shelf LLMs and ad-hoc NLP tools, F2W addresses ontology gaps and reduces hallucination risk by grounding responses in extracted evidence and enforcing schema constraints; it also offers deterministic, provenance-linked outputs and open, cost-aware deployment. Evidence-aware ranking further improves answer quality over pure vector search.

Abramov, David [Lawrence Berkeley National Laborat↗

SolarAPP+ Enhancements and Commercialization (Final Technical Report)

With millions of distributed photovoltaic (PV) systems expected to be installed over the next five years, the permitting and inspection processes of authorities having jurisdiction (AHJs) may become overburdened, causing delays and increased costs for installed systems (Cruce et al. 2022). The central goal of this project was to automate and streamline permitting processes for distributed PV systems and complementary technologies, such as battery storage. Deploying automated permitting has been hypothesized to reduce permit review times, resulting in reduced costs and improved customer experience. This has the potential to expand the PV and PV-plus-storage market nationwide. The National Renewable Energy Laboratory (NREL) and its project partners, including UL Solutions, the Interstate Renewable Energy Council (IREC), the International Code Council (ICC), and more, developed the Solar Automated Permit Processing (SolarAPP+™) software platform to reduce permit review times. NREL and its partners also collaborated with the solar industry, the building safety community, and local governments to develop SolarAPP+.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

De novo atomic protein structure modeling for cryoEM density maps using 3D transformer and HMM

Accurately building 3D atomic structures from cryo-EM density maps is a crucial step in cryo-EM-based protein structure determination. Converting density maps into 3D atomic structures for proteins lacking accurate homologous or predicted structures as templates remains a significant challenge. Here, we introduce Cryo2Struct, a fully automated de novo cryo-EM structure modeling method. Cryo2Struct utilizes a 3D transformer to identify atoms and amino acid types in cryo-EM density maps, followed by an innovative Hidden Markov Model (HMM) to connect predicted atoms and build protein backbone structures. Cryo2Struct produces substantially more accurate and complete protein structural models than the widely used ab initio method Phenix. Additionally, its performance in building atomic structural models is robust against changes in the resolution of density maps and the size of protein structures.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Are humans still necessary? Expanding the discussion

The rise of automation, artificial intelligence (AI), and autonomous systems raises important questions about the future role of humans and the field of human factors/ergonomics in workplaces. This paper builds on Dr. Peter Hancock’s 2023 ‘Are Humans Still Necessary?’ article published in the Ergonomics journal. Using a multi-method approach that included a debate, opinion polling, roundtable discussions, and AI queries, the current effort examined the necessity of human involvement in future work environments. Debate team members presented arguments for and against the need for human workers, considering human factors, technology, and socioeconomic factors. Observations indicate that while AI may handle routine tasks, humans will likely remain essential for complex decision making, creativity, and ethical considerations. The paper advocates for viewing workplace dynamics as collaborative human-AI partnerships rather than competition, highlighting the need for a transdisciplinary approach in which human factors/ergonomics professionals play a vital role in enhancing these relationships.

99 - GENERAL AND MISCELLANEOUS↗

Automated instant labeling chemistry workflow for real-time monitoring of monoclonal antibody N -glycosylation

With the transition toward continuous bioprocessing, process analytical technology (PAT) is becoming necessary for rapid and reliable in-process monitoring during biotherapeutics manufacturing. Bioprocess 4.0 is looking to build end-to-end bioprocesses that include PAT-enabled real-time process control. This is especially important for drug product quality attributes that can change during bioprocessing, such as protein N-glycosylation, a critical quality attribute for most monoclonal antibody (mAb) therapeutics. Glycosylation of mAbs is known to influence their efficacy as therapeutics and is regulated for a majority of mAb products on the market today. Currently, there is no method to truly measure N-glycosylation using on-line PAT, hence making it impractical to design upstream process control strategies. We recently described the N-GLYcanyzer workflow: an integrated PAT unit that measures mAb N-glycosylation within 3 hours of automated sampling from a bioreactor. Here, we integrated Agilent's Instant Procainamide (InstantPC) based chemistry workflow into the N-GLYcanyzer PAT unit to allow for nearly 10× faster near real-time analysis of mAb glycoforms. Furthermore, our methodology is explained in detail to allow for replication of the PAT workflow as well as present a case study demonstrating the use of this PAT to autonomously monitor a mammalian cell perfusion process at the bench scale to gain increased knowledge of mAb glycosylation dynamics during continuous biologics manufacturing using Chinese hamster ovary (CHO) cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Informing forest carbon inventories under the Paris Agreement using ground-based forest monitoring data

Human interactions with forests have shaped Earth's climate for millennia and will continue to do so as we target net-zero emission goals. Accurately characterizing these climate impacts requires making reliable forest carbon data available for forest monitoring and planning. Here, we develop a semi-automated process for submitting forest carbon measurements from the largest relevant scientific database to the International Panel on Climate Change's Emission Factor Database, which currently has sparse forest carbon data. Building this bridge from scientific research to international policy is an important step towards managing forests in a net-zero motivated future. Humans have been influencing Earth's climate via transformative impacts on forests for millennia, and forests are now recognized as critical to climate change mitigation under the Paris Agreement. The efficacy of climate change mitigation planning and reporting depends on quality data on forest carbon (C) stocks and changes. The Emission Factor Database (EFDB) of the International Panel on Climate Change (IPCC) is intended to be a definitive source for such data, but needs comprehensive and well-documented data to be so. To facilitate submission of forest C estimates from scientific studies to EFDB, we develop and document a process for semi-automated data submission from the Global Forest C database (ForC v4.0), which is the largest compilation of ground-based forest C estimates. We then assess the data currently available through ForC and provide recommendations for improving forest data collection, analysis, and reporting. As of September 2024, ForC contained ~19,286 records potentially relevant to EFDB, 1068 of which had been submitted and posted to EFDB. These represented 19% of the total EFDB records for forest land. Records were unevenly distributed across variables and geographic regions. ForC records (37%) reviewed could not be submitted because the original publication lacked required information. In the future, ground-based forest C estimates should target gaps in the record, and studies should ensure that they report all information necessary for inclusion in EFDB. Given that climate change is rapidly impacting the world's forests, timely reporting of recent estimates will be critical to accurate forest C inventories.

54 ENVIRONMENTAL SCIENCES↗

Facility Cybersecurity Framework Best Practices

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought. The U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP) funded the Pacific Northwest National Laboratory (PNNL) to develop various cybersecurity tools, trainings, and reports to aid federal facility managers – and other building owners and operators – in better applying frameworks and lessons learned from the National Institute of Standards and Technology (NIST) Cybersecurity Framework (CSF), risk management framework (RMF), DOE’s cybersecurity capability maturity model (C2M2), and a wide variety of industry best practices and guidance documents (i.e., NIST 800 series, Department of Defense United Facilities Criteria). This set of tools, collectively known as the FEMP Facility-Related Control System Cyber Toolkit (FRCS Cyber Toolkit)2, is focused on cybersecurity concerns from facility-related control systems and other operational technology (OT), such as industrial control systems (ICS). The FRCS Cyber Toolkit can be applied across six of the sixteen critical infrastructure sectors designated by the Department of Homeland Security, including government facilities, healthcare and public health, commercial facilities (e.g., public assembly, offices, lodging), financial services (e.g., banking and insurance), emergency services (e.g., fire and police stations), and information technology. With increasingly converged IT and OT systems, it is crucial to address OT cybersecurity considerations and assess how the seam of these two systems could impact the overall cybersecurity posture of a facility. The objective of this report is to provide an overview of the best possible method to use FRCS Cyber Toolkit (section 2.0) and distilled cybersecurity best practices for the federal facilities to address growing non-linear cyber threats (section 3.0). Recommendations in this document are aggregated from several NIST and other documents (see Appendix A for additional details).

97 MATHEMATICS AND COMPUTING↗

Facility Cybersecurity Framework Best Practices Version 2.0

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗