Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOILING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Flow Boiling and Condensation Experiment: Payload Design Overview

The Flow Boiling and Condensation Experiment (FBCE) is a flight experiment that is designed to operate in the Fluids Integrated Rack (FIR) on the International Space Station (ISS). The objective of the FBCE is to develop an integrated two-phase flow experiment that will serve as a primary platform for obtaining flow boiling and condensation heat transfer data in microgravity. This presentation discusses the overall design of the FBCE payload, as well as the status of the FBCE hardware as it continues through final verification testing.

Guzik, Monica C.↗

Theoretical Limits of Vapor Cooling Large Cylindrical Structures Using Boil-Off

The Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) is planning to demonstrate the performance benefits of using boil-off to reduce the heat load on various upper stage structural members by using the boil-off vapor to intercept some of the heat load on the structures. A first order simplified analytical model was constructed in order to understand sensitivity of various parameters to performance as well as to understand the theoretical maximum performance of the vapor cooling of a thin-walled cylindrical structure. Constant fluid properties and a temperature dependent thermal conductivity of the structure material were assumed. The model showed that vapor cooling of an aluminum cylindrical structure with hydrogen can reduce the heat load along the cylinder by as much as 70%. Also, cooling a portion of the cylinder is quite effective in comparison with cooling it entirely.

R. Balasubramaniam↗

The Zero-Boil-Off Tank Experiment: the Effects of Non-Condensable Gases on Pressurization and Pressure Control of Propellant Tanks in Microgravity

Introduction Integral to all phases of NASA’s projected planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. It is greatly advantageous to develop innovative vent-less pressure control designs based on cooling/mixing of the bulk tank fluid to allow storage of the cryogenic fluid with zero or reduced boil-off. The presence of noncondensable gases, can interfere with the condensation at the interface impacting tank pressure control during subcooled jet mixing especially in microgravity. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small-scale experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena associated with storage tank pressurization and pressure control in microgravity. The ZBOT-1 experiment was performed on the ISS 2017-2018 timeframe and collected data to validate a state-of-the-art CFD model for tank pressurization and pressure control for a pure system. The ZBOT-NC Experiment is the second experiment in the series to be performed on the International Space Station (ISS) in 2025. Its goal is to investigate the effects of noncondensable gases on interfacial evaporation and condensation during self -pressurization and jet-mixing pressure control in microgravity for a two-component system. Materials & Methods In this work, we will describe the detailed features of the ZBOT-NC experimental hardware and Diagnostics that includes nonintrusive Quantum Dot Thermometry (QDT) for whole field temperature measurement. All microgravity pressurization and pressure control tests will be performed for both the pure and the two-components systems with Xenon and Neon as the two noncondensable gases spanning small and large molecular weights and sizes. The two-phase CFD model that is developed as part of the project will be also presented and discussed. Results Ground-based pressurization and jet mixing experiments and CFD simulation results are compared to each other to validate both the fidelity of the CFD model predictions and the accuracy of the QDT measurement. Model simulations for noncondensable gas effects will also be compared against large Cryogenic LH2-GHe experiments to indicate the noncondensable gas effects on tank pressure control during jet mixing in 1G. Finally, CFD results will be presented to predict the effects of the noncondensable gas during subcooled jet mixing during the ZBOT-NC in advance of the microgravity experiment in 2015.

Evaporation Condensation↗

Experimental investigation on nucleate boiling heat transfer of low GWP refrigerants over metal-foam enhanced tube bundles

The objective of this work is to develop an enhanced tube bundle to improve the nucleate boiling heat transfer for the application of flooded evaporators. The enhanced tube bundle was made by deploying metal foam around the outer surface of aluminum tubes, which provide higher heat transfer area and nucleation site density. The pool boiling experiments for horizontal tube bundles were conducted in a pressure vessel at difference heat fluxes. The heat transfer performance of bare aluminum tube bundle was compared against the metal-foam enhanced tube bundle using low GWP refrigerant, R-1234yf. The experimental results showed that the heat transfer coefficient of the metal-foam enhanced tube bundle was at least two times higher than that of the bare tube bundle, and the enhancement ratio depended on the heat flux condition.

Yang, Cheng-Min↗

Ion Exchange Column Thermal Modeling: Prevention of Process Effluent Boiling - 18577

The Savannah River Site treats and disposes of legacy high-level waste, which resulted from 60 years of nuclear material production, medical research, and other nuclear related work. Complex mixtures of soluble and insoluble solids occupy tanks of which the South Carolina Department of Health and Environmental Control recognizes as the single largest environmental risk state-wide. The risk is reduced through removal, treatment, and solidification of decontaminated salt waste. Presently, SRS decontaminates the soluble salt component of the waste, a solution containing actinides and cesium, via implementation of the Actinide Removal Process and the Modular Caustic Side Solvent- Extraction Unit. Caustic solvent extraction is set to increase in scale by late 2018, with startup of the newly constructed Salt Waste Processing Facility. In conjunction with Salt Waste Processing Facility startup, Savannah River Remediation has been tasked by the Department of Energy to demonstrate modular ion exchange technology. The Tank Closure Cesium Removal project aims to demonstrate the feasibility of modular ion exchange processes for future Department of Energy applications. The Tank Closure Cesium Removal system is scheduled to begin operation in mid-2018. Dissolved salt solution, or influent, will be fed through a filter and ion exchange columns in lead-lag configuration, producing effluent. The effluent is fed to a separate high-level waste tank, for future disposition at Salt-stone Production Facility. Once the demonstration project is complete, the loaded ion exchange columns will be purged, dried, and placed in interim safe storage, awaiting final disposition. The ion exchange media selected for the Tank Closure Cesium Removal system is Honeywell UOP IONSIV{sup C} R-9120. The media is a prime candidate for separation of cesium from radioactive high-level waste. UOP R-9120{sup C} is inorganic and has high capacity, selectivity, and affinity for cesium. During operation, influent is fed to the ion exchange columns, contacting UOP R-9210{sup C} packed within the media vessel. Contact initiates loading of isotopes, and given ample time the solid phase (ion exchange media) and solution achieve thermodynamic equilibrium. UOP R-9120{sup C} is a prime candidate for separation of cesium and dissolved fission products. Although the properties of UOP R-9120{sup C} are favorable for separation, the same properties lead to accumulation of a heat source in the ion exchange bed. Cesium-137 and its daughter product, barium-137 m, generate a clear majority of heat (i.e. ∼ 94%). During operation salt solution flows through each column and transports heat from the ion exchange bed. Once operation is terminated, the effluent contained within the porous bed volume becomes essentially static. In the absence of engineering controls, the heat generated may boil the effluent. Rapid vaporization of aqueous salt solution would lead to bed over pressurization. Over pressurization and an associated release of high-level waste would result in adverse impacts to human health and the environment. This paper focuses on modeling the heat transfer associated with the Tank Closure Cesium Removal system ion exchange column. The model evaluates the maximum heat generation and the associated radionuclide loadings that prevent boiling within of the media vessel, under no flow conditions. A safety significant control, maintaining loadings less than the established loading limit ensures associated impacts to human health and the environment are prevented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Experimental study on bubble dynamics and wall heat transfer arising from a single nucleation site at subcooled flow boiling conditions – Part 2: Data analysis on sliding bubble characteristics and associated wall heat transfer

In this second of two companion papers presents an analysis of sliding bubble and wall heat transfer parameters measured during subcooled boiling in a square, vertical, upward flow channel. Bubbles were generated only from a single nucleation site for better observation of both the sliding bubbles’ characteristics and their impact on wall heat transfer through optical measurement techniques. Specific interests include: (i) bubbles departure and subsequent growth while sliding, (ii) bubbles release frequency, (iii) coalescence of sliding bubbles, (iv) sliding bubbles velocity, (v) bubbles size distribution and (vi) wall heat transfer influenced by sliding bubbles. Our results showed that sliding bubbles involve two distinct growth behaviors: (i) at low mass fluxes, sliding bubbles grew fast near the nucleation site, subsequently shrank, and then grew again, (ii) as mass flux increased, however, sliding bubbles grew more steadily. The bubbles originating from the single nucleation site coalesced frequently while sliding, which showed close relation with bubbles release frequency. The sliding bubble velocity near the nucleation site consistently decreased by increasing mass flux, while the observation often became reversed as the bubbles slid downstream due to the effect of interfacial drag. The sliding bubbles moved faster than the local liquid (i.e., ur<0) at low mass flux conditions, but it became reversed as the mass flux increased. The size distribution of sliding bubbles followed Gaussian distribution well both near and far from the nucleation site. The standard deviation of bubble size varied insignificantly through sliding compared to the changes in mean bubble size. Lastly, the sliding bubbles enhanced the wall heat transfer and the effect became more noticeable as inlet subcooling/mass flux decreased or wall heat flux increased. Particularly, the sliding bubble characteristics such as bubble growth behavior observed near the nucleation site played a dominant role in determining the ultimate level of wall heat transfer enhancement within the test channel.

42 ENGINEERING↗

A new method for calculating normal boiling point of liquids

A method for predicting normal boiling points (NBPs) of pure liquids based on linear free energy relationships (LFERs) and thermodynamics formulas is proposed. For 15 classes of chemical compounds (a total of 683 substances), correlation equations relating NBPs to molecular descriptors were obtained using stepwise regression. For all equations, the mean relative deviations (MD) lie between 0.89% and 2.83%, being mostly less than 2%. The correlation coefficients of 13 equations are larger than 0.98. The correlation equations obtained are simple, have clear physical sense, wide applicability range and provide rather high predictive power and accuracy of calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ANN-based correlation for frictional pressure drop of non-azeotropic mixtures during cryogenic forced boiling

A crucial aspect of Joule-Thomson cryocooler analysis and optimization is the accurate estimation of frictional pressure drop. This paper presents a pressure drop model for boiling of non-azeotropic mixtures of nitrogen with hydrocarbons (e.g., methane, ethane, and propane) in microchannels. These refrigerant mixtures are important for their applicability in natural gas liquefaction plants. Here, the pressure drop model is based on computational intelligence techniques, and its performance is evaluated with the mean relative error (mre), and compared with three correlations previously selected as most accurate: Awad and Muzychka; Sun and Mishima; and Cicchitti et al.

42 ENGINEERING↗

Enhanced flow boiling heat transfer on chromium coated zircaloy-4 using cold spray technique for accident tolerant fuel (ATF) materials

Flow boiling heat transfer tests were conducted to evaluate the Critical Heat Flux (CHF) and Heat Transfer Coefficient (HTC) of conventional and accident tolerant fuel (ATF) cladding materials, i.e., bare Zircaloy-4 (Zr4), and Zircaloy-4 coated with Chromium using physical vapor deposition (PVD) (Zr4-Cr-PVD) and cold spray process (Zr4-Cr-CS), respectively. The tests were performed on a single heater rod with a uniform heat flux profile, at the atmospheric pressure, inlet temperature (24 °C) and mass flow rate (750 kg/m 2 s). HTC’s were increased by 5.2% and 3.3% on Zr4-Cr-CS compared to bare Zr4 and Zr4-Cr-PVD. Improved HTCwas attributed to the increased void fraction and high roughness (Ra = 532 nm) of the Zr4-Cr-CS. In detail, the micro-cavities, which act as bubble seeds, were entirely distributed on the Zr4-Cr-CS, and these micro-cavities generated smaller and faster bubbles, thus the void fraction increased by 10.9% compared to bare Zr4. HTC is improved by these smaller and faster bubbles which can remove heat from the heater rod surface more efficiently. To identify the exact location of CHF, the surface temperature profile was measured using advanced fiber-optic sensors which have high temporal/spatial resolution (distance between point to point: ~2.5 mm, frequency ~100 Hz). CHF occurred at 80–95% along the heated length and showed an 11.6% reduction on Zr4-Cr-CS compared to bare Zr4. We hypothesize the CHF reduction was caused by the lower wettability of the Zr4-Cr-CS which reduces the liquid supply to the surface, and vigorous bubble accumulation owing to high void fraction near the outlet, which results in early formation of the vapor film. During the post-CHF quenching phase, the rougher Zr4-Cr-CS showed larger cooling rates compared to the bare Zr4 and Zr4-Cr-PVD, preventing of oxidation by chromium layer. In conclusion, we demonstrate that the high roughness on the Zr4-Cr-CS increased the number of micro-cavities on the surface, resulting in 5.2% increase in HTC and improvement in the quenching heat transfer performance whereas CHF was 11.6% reduced compared to bare Zr4. Overall statistically there is little effect in the coating with regards to CHF and slight improvement in HTC.

42 ENGINEERING↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

Area of bubble influence due to sliding bubbles in subcooled boiling flow

The heat transfer effect of sliding bubbles is discussed in two aspects based on new experimental findings: (i) the area of bubble influence and (ii) bubble sliding characteristics influencing the degree of wall heat transfer. One notable finding was that the bubble sliding behavior, characterized by sliding trajectories, played a crucial role in determining the area of bubble influence and the bubble influence factor (K). Also, such sliding characteristic was observed strongly dependent on the sliding bubble size. An empirical model has been proposed based on this finding to evaluate the bubble influence factor (K) for the sliding bubbles. Another experimental finding was that the bubble sliding characteristic, represented by bubble spreading factor (S), had a significant impact on the degree of wall heat transfer induced by sliding bubbles. This is due to the fact that the bubbles spread across the heater width as they slid downstream, which reduced the effective frequency of sliding bubbles per unit wall area. These new findings not only improve our understanding of the heat transfer associated with sliding bubbles, but also are expected to contribute to improving the insight in the existing CFD boiling heat transfer models.

42 ENGINEERING↗

String flash-boiling in gasoline direct injection simulations with transient needle motion

A computational study was performed to investigate the influence of transient needle motion on gasoline direct injection (GDI) internal nozzle flow and near-field sprays. Simulations were conducted with a compressible Eulerian flow solver modeling liquid, vapor, and non-condensable gas phases with a diffuse interface. Variable rate generation and condensation of fuel vapor were captured using the homogeneous relaxation model (HRM). The non-flashing (spray G) and flashing (spray G2) conditions specified by the Engine Combustion Network were modeled using the nominal spray G nozzle geometry and transient needle lift and wobble were based upon ensemble averaged x-ray imaging preformed at Argonne National Lab. The minimum needle lift simulated was 5 μm and dynamic mesh motion was achieved with Laplacian smoothing. The results were qualitatively validated against experimental imaging and the experimental rate of injection profile was captured accurately using pressure boundary conditions and needle motion to actu- ate the injection. Needle wobble was found to have no measurable effect on the flow. Low needle lift is shown to result in vapor generation as fuel rushes past the needle. In conclusion, the internal injector flow is shown to contain many transient and interacting vortices which cause perturbations in the spray angle, fluctuations in the mass flux, and frequently result in string flash-boiling.

33 ADVANCED PROPULSION SYSTEMS↗

Time-resolved measurements of liquid–vapor thermal interactions throughout the full life-cycle of sliding bubbles at subcooled flow boiling conditions

The local thermal response of the liquid phase to the presence of sliding bubbles was measured with an infrared camera in subcooled flow-boiling conditions. These measurements were complemented with two high-speed cameras to capture the corresponding bubbles’ dynamics. The liquid–vapor interactions were captured in detail over the full life-cycle of sliding bubbles. Four distinctive phases for the bubble life-cycle were identified: A) Spherical bubble growth with strong attachment, B) Deformed bubble growth with weak attachment, C) Detachment with hot liquid quenching, and D) Cold liquid quenching. Here, to the best of the authors’ knowledge, it is the first time that the “detachment with hot liquid quenching phase has been observed. This phase is characterized by a “hot” thermal footprint during the bubble detachment process. It is believed that this footprint is constituted partially from hot liquid released during the condensation of the recently detached bubble, and from released hot fluid previously collected by the bubble during sliding. In addition, this work reveals that using traditional high-speed visualization techniques (side-view camera only) can lead to an underestimation of approximately 40% of the actual bubble–wall contact diameter (dc) which was inferred from the infrared camera measurements.

42 ENGINEERING↗

The passivity of low-temperature carburized austenitic stainless steel AISI-316L in a simulated boiling-water-reactor environment

The passive film on low-temperature-carburized AISI-316L austenitic stainless steel was studied in an oxygenated, simulated boiling-water-reactor environment with normal water chemistry. The microstructure was studied using scanning electron microscopy, grazing-incidence X-ray diffractometry, Auger electron spectroscopy, X-ray energy-dispersive spectroscopy, and transmission electron microscopy. For non-surface engineered AISI-316L, three distinct layers were observed after exposure: an outer layer of larger nickel-oxide enriched particles with the spinel structure, an intermediate layer of small Cr-oxide-enriched hematite particles, and a compact inner layer of Cr-enriched oxide also having the spinel structure. Exposure of low-temperature-carburized AISI-316L, in contrast, resulted in only two distinct layers. These layers did not include a compact Cr-rich inner layer. Instead, the innermost layer consisted of an oxide with the spinel structure that was a mixture of Fe, Cr and Ni oxide. The outer layer on the low-temperature-carburized specimen consisted of large loosely stacked particles with the spinel structure of mixed composition. In addition to passive-film characterization, the corrosion rate was studied by monitoring mass loss. Finally, after 500 h of immersion, the mass changes measured were relatively low for all specimens indicating good adhesion and low oxidation rates.

36 MATERIALS SCIENCE↗