Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Compact steady-state and high-flux Falcon ion source for tests of plasma-facing materials

This paper describes the design and operation of the Falcon ion source. It is based on conventional design of anode layer thrusters. This ion source is a versatile, compact, affordable, and highly functional in the research field of the fusion materials. The reversed magnetic field configuration of the source allows precise focusing of the ion beam into small spot of Almost-Equal-To 3 mm and also provides the limited capabilities for impurity mass-separation. As the result, the source generates steady-state ion beam, which irradiates surface with high heat (0.3 - 21 MW m{sup -2}) and particle fluxes (4 Multiplication-Sign 10{sup 21}- 3 Multiplication-Sign 10{sup 23} m{sup -2}s{sup -1}), which approaches the upper limit for the flux range expected in ITER.

43 PARTICLE ACCELERATORS↗

NDCX-II, an Induction Linac for HEDP and IFE Research

The Heavy Ion Fusion Science Virtual National Laboratory in the USA is constructing a new Neutralized Drift Compression eXperiment (NDCX-II) at LBNL. This facility is being developed for high energy density physics and inertial fusion energy research. The 12 m long induction linac in NDCX-II will produce a Li{sup +} beam pulse, at energies of 1.2-3 MeV, to heat target material to the warm dense matter regime ({approx} 1 eV). By making use of special acceleration voltage waveforms, 2.5T solenoid focusing, and neutralized drift compression, 20 - 50 nC of beam charge from the ion source will be compressed longitudinally and radially to achieve a subnanosecond pulse length and mm-scale target spot size. The original Neutralized Drift Compression Experiment (NDCX-I) has successfully demonstrated simultaneous radial and longitudinal compression by imparting a velocity ramp to the ion beam, which then drifts in a neutralizing plasma to and through the final focussing solenoid and onto the target. At higher kinetic energy and current, NDCX-II will offer more than 100 times the peak energy fluence on target of NDCX-I. NDCX-II makes use of many parts from the decommissioned Advanced Test Accelerator (ATA) at LLNL. It includes 27 lattice periods between the injector and the neutralized drift compression section (Figure 1). There are 12 energized induction cells, 9 inactive cells which provide drift space, and 6 diagnostic cells which provide beam diagnostics and pumping. Custom pulsed power systems generate ramped waveforms for the first 7 induction cells, so as to quickly compress the beam from 600 ns at the injector down to 70 ns. After this compression, the high voltages of the ATA Blumleins are then used to rapidly add energy to the beam. The Blumleins were designed to match the ferrite core volt-seconds with pulses up to 250 kV and a fixed FWHM of 70 ns. The machine is limited to a pulse repetition rate of once every 20 seconds due to cooling requirements. The NDCX-II beam is highly space-charge dominated. The 1-D ASP code was used to synthesize high voltage waveform for acceleration, while the 3-D Warp particle-in-cell code was used for detailed design of the lattice. The Li{sup +} ion was chosen because its Bragg Peak energy (at {approx} 2 MeV) coincides with the NDCX-II beam energy. The 130 keV injector will have a 10.9 cm diameter ion source. Testing of small (0.64 cm diameter) lithium doped alumino-silicate ion sources has demonstrated the current density ({approx} 1 mA/cm{sup 2}) used in the design, with acceptable lifetime. A 7.6 cm diameter source has been successfully produced to verify that the coating method can be applied to such a large emitting area. The ion source will operate at {approx} 1275 C; thus a significant effort was made in the design to manage the 4 kW heating power and the associated cooling requirements. In modifying the ATA induction cells for NDCX-II, the low-field DC solenoids were replaced with 2.5 T pulsed solenoids. The beam pipe diameter was decreased in order to reduce the axial extent of the solenoid fringe fields and to make room for water cooling. In addition, an outer copper cylinder (water-cooled) was used to exclude the solenoid magnetic flux from the ferrite cores. Precise alignment is essential because the beam has a large energy spread due to the rapid pulse compression, such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. A novel pulsed-wire measurement method is used to align the pulsed solenoid magnets. Alignment accuracy has been demonstrated to within 100 {micro}m of the induction cell axis. The neutralized drift compression region after the last induction cell is approximately 1.2 m long and includes ferroelectric plasma sources (FEPS) fabricated by PPPL similar to those successfully operating in NDCX-I. The 8-T final focus pulsed solenoid, filtered cathodic arc plasma sources (FCAPS), and target chamber from NDCX-I are to be relocated to NDCX-II. The NDCX-II project started in July 2009 and is expected to complete in fall of 2011. As future funds become available, additional induction cells and pulsed power systems will be added to increase the beam energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Challenges in High-Current Pulsed Striplines

The Long Baseline Neutrino Facility (LBNF) will produce the worlds most intense neutrino beam. Three series connected magnetic horns will require 5 kV, 300 kA, 800 $\mu$s pulses at a rate of 1.4 Hz to focus the beam. Connecting a single power supply to these focusing horns will require a low impedance connection measuring over 60 m in length. To meet the challenging requirements of connecting the horns to the power supply, this connection is engineered as a nine-conductor, high-current pulsed stripline. It must pass through a harsh radiation environment, be passively cooled, and have an operational lifetime of at least 30 years. This paper discusses mechanical and electrical considerations such as high-voltage holdoff, clamped joint performance, and Lorentz force mitigations in order to meet the specified requirements. The results of tests and experiments on several prototypes of key design features will be presented and discussed.

43 PARTICLE ACCELERATORS↗

The Q weak experimental apparatus

The Jefferson Lab Q weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was created for this experiment to meet the technical challenges presented by the smallest and most precise e → p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 μA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Møller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8° and 11.6° were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cherenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q 2 =0.025 GeV 2 was observed using dedicated low-current ( ~ 100 pA ) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a superconducting magnet system operated in the Super Omega Muon beam line at J-PARC

A superconducting magnet system, which is composed of an 8 m long solenoid for transportation and 12 short solenoids for focusing, has been developed for Muon Science Establishment facility of J-PARC. The transport solenoid is composed of a 6 m straight section connected to a 45 degree curved section at each end. Muons of various momenta and of both electric charges are transported through the solenoid inner bore with an effective diameter of 0.3 m, where 2 T magnetic field is induced. There are 12 focusing solenoids with an effective bore diameter of 0.6 m and a length of 0.35 m arranged on a straight line at suitable intervals. The maximum central field of each focusing solenoid is 0.66 T. All solenoid coils are cooled by GM cryocoolers through their own conductions. The magnet system has been installed into the beam line in the summer of 2012, and its performance has been checked. Beam commissioning has been carried out since October 2012. During beam operation, temperature rise over 6 K in the transport solenoid due to a nuclear heating from the muon production target is observed at beam intensity of about 300 kW.

43 PARTICLE ACCELERATORS↗

First Results from Diamagnetic Loop Measurements of the DARHT-I Electron Beam [Slides]

Diamagnetic-loop (DML) measurements can inform efforts to improve radiographic resolution. DML is non-invasive, so time-resolved data is available on every shot while tuning or executing a hydrotest. The time-resolved beam size can be deduced from the DML data. LIA beam-transport dynamics affecting beam size can be monitored while testing mitigation measures (e.g., beam halo suppression). Time-resolved beam size at final focus provides immediate information about spot size enlargement due to blur, and effectiveness of mitigation efforts. DML measures magnetic flux produced by a rotating beam, so it also enables monitoring of Larmor emittance that can enlarge the spot size. Beam rotation adds in quadrature with emittance, hence “Larmor emittance." Observing zero bias-field DML flux monitors beam rotation resulting from imperfect nulling of flux linking the cathode, and/or broken LIA transport symmetry (e.g., steering, quads, etc.).

43 PARTICLE ACCELERATORS↗

Next Generation Muon g-2 Experiments

I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a factor of 4; that is, $\delta a_\mu \sim 16 \times 10^{-11}$, a relative uncertainty of 140~ppb. The method follows the same magic-momentum storage ring concept used at BNL, and pioneered previously at CERN, but muon beam preparation, storage ring internal hardware, field measuring equipment, and detector and electronics systems are all new or upgraded significantly. In contrast, J-PARC E34 will employ a novel approach based on injection of an ultra-cold, low-energy, muon beam injected into a small, but highly uniform magnet. Only a small magnetic focusing field is needed to maintain storage, which distinguishes it from CERN, BNL and Fermilab. E34 aims to roughly match the previous BNL precision in their Phase~1 installation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-intensity, high-brightness polarized and unpolarized beam production in charge-exchange collisions

Basic limitations on the high-intensity H{sup -} ion beam production were experimentally studied in charge-exchange collisions of the neutral atomic hydrogen beam in the Na-vapour jet ionizer cell. These studies are the part of the polarized source upgrade (to 10 mA peak current and 85% polarization) project for RHIC. In the source the atomic hydrogen beam of a 5-10 keV energy and total (equivalent) current up to 5 A is produced by neutralization of proton beam in pulsed hydrogen gas target. Formation of the proton beam (from the surface of the plasma emitter with a low transverse ion temperature {approx}0.2 eV) is produced by four-electrode spherical multi-aperture ion-optical system with geometrical focusing. The hydrogen atomic beam intensity up to 1.0 A/cm{sup 2} (equivalent) was obtained in the Na-jet ionizer aperture of a 2.0 cm diameter. At the first stage of the experiment H-beam with 36 mA current, 5 keV energy and {approx}1.0 cm {center_dot} mrad normalized emittance was obtained using the flat grids and magnetic focusing.

08 HYDROGEN↗

3D Quantum Anomalous Hall Effect in Magnetic Topological Insulator Trilayers of Hundred‐Nanometer Thickness

Magnetic topological states refer to a class of exotic phases in magnetic materials with the non-trivial topological property determined by magnetic spin configurations. An example of such states is the quantum anomalous Hall (QAH) state, which is a zero magnetic field manifestation of the quantum Hall effect. Current research in this direction focuses on QAH insulators with a thickness of less than 10 nm. Here, molecular beam epitaxy (MBE) is employed to synthesize magnetic TI trilayers with a thickness of up to ≈106 nm. It is found that these samples exhibit well-quantized Hall resistance and vanishing longitudinal resistance at zero magnetic field. By varying the magnetic dopants, gate voltages, temperature, and external magnetic fields, the properties of these thick QAH insulators are examined and the robustness of the 3D QAH effect is demonstrated. The realization of the well-quantized 3D QAH effect indicates that the nonchiral side surface states of the thick magnetic TI trilayers are gapped and thus do not affect the QAH quantization. The 3D QAH insulators of hundred-nanometer thickness provide a promising platform for the exploration of fundamental physics, including axion physics and image magnetic monopole, and the advancement of electronic and spintronic devices to circumvent Moore's law.

36 MATERIALS SCIENCE↗

Beam imaging in the injection line of the INFN-LNS superconducting cyclotron

A cheap and efficient diagnostic system for beam monitoring has been recently developed at INFN-LNS in Catania. It consists of a high sensitivity CCD camera detecting the light produced by an ion beam hitting the surface of a scintillating screen and a frame grabber for image acquisition. A scintillating screen, developed at INFN-LNS and consisting of a 2 μm BaF{sub 2} layer evaporated on an aluminium plate, has been tested by using {sup 20}Ne and {sup 40}Ar beams in the keV energy range. The CAESAR ECR ion source has been used for investigating the influence of the frequency and magnetic field tuning effects, the impact of the microwave injected power, and of the focusing solenoids along the low energy beam transport on the beam shape and current. These tests will allow to better understand the interplay between the plasma and beam dynamics and, moreover, to improve the transport efficiency along the low energy beam line and the matching with the superconducting cyclotron, particularly relevant in view of the expected upgrade of the machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QM02 Strength Measurement

In late April, Paul Emma reported that his orbit fitting program could find a reasonably good fit only if the strength of QM02 was changed from design value of -5.83 kG to -6.25 kG - a strength change of 7.3%. In late May, we made a focal length measurement of QM02 by turning off all focusing optics between YC07 and BPMS1 (in the spectrometer line) except for QM02 and adjusted the strength of QM02 so that vertical kicks by YC07 did not produce any displacements at BPMS1 (see Figure 1). The result was quoted in the LCLS elog was that QM02 appeared to 6% too weak, and approximately agreed with Paul's observation. The analysis used for the entry in the log book was based on the thin lens approximation and used the following numbers: Distance YC07 to QM02 - 5.128 m; Distance QM02 to BPMS1 - 1.778 m; and Energy - 135 MeV. These distances were computed from the X,Z coordinates given the on the large plot of the Injector on the wall of the control room. On review of the MAD output file coordinates, it seems that the distance used for QM02 to BPMS1 is not 1.778 m. The correct value is Distance, center of QM02 to BPMS1 - 1.845 m. There may be a typo on the wall chart values for the coordinates of BPMS1, or perhaps there was a misinterpretation of edge versus center of QM02. In any case, the effect of this change is that the thin lens estimate changes from 6% too weak to 9% too weak. At John Galayda's suggestion, we looked into the thin lens versus thick lens approximation. A Mathematica program was written to solve for the K value of the QM02, in the thick lens approximation, that provides point to point focusing from YC07 to BPMS1, and to compare this number with the value obtained using the thin lens approximation. The length of QM02 used in the thick lens calculation is the effective length determined by magnetic measurements of 0.108 m. The result of the Mathematica calculation is that the thin lens approximation predicts less magnet strength is required to produce the same focusing by about 1.3%. When both the distance correction and the thick lens approximation are taken into account, the result is: K{sub thick} - K{sub mm}/K{sub thick} = -7.6% where K{sub mm} is the value obtained from magnetic measurements and K{sub thick} is the value of K obtained from the focal length measurement in the thick lens approximation. That is, QM02 acts weaker than it was measured by magnetic measurements by 7.6%. This is remarkably close to Paul's original estimate. The unexpected weakness could in principle be due to several things: shorted turns, a current calibration error, magnetic measurement error; it could even be due to the presence of an gradient from QM01, which is of opposite sign and right next to QM02, despite it being set to zero current (although it was not DAC-zeroed). Plans have been implemented to remove and replace QM02 at the earliest ROD.

43 PARTICLE ACCELERATORS↗

Experimental evidences for emittance degradation by space charge effect when using a focusing solenoid below an electron cyclotron resonance ion source

Solenoids are widely used to provide initial focusing of beams extracted from an ion source. However, in the case of an electron cyclotron resonance (ECR) ion source, the extracted beam will usually include different ion species and for each of them a wide distribution of charge states. When such a multicomponent beam is focused by a solenoid, the ions with a Q/A larger than the beam of interest are overfocused and usually go through a waist before reaching the analyzing magnet. If the beam currents obtained for these ions are sufficient, the resulting space charge forces can significantly degrade the emittance of the beam components with a lower Q/A and result for those in a hollow beam. Using a beam viewer and an emittance-measuring device, this paper reports on experimental findings that confirm the existence of such an effect for low charge states of argon. Moreover, by changing the experimental conditions of the ECR plasma in order to modify the charge state distribution of the extracted ion beam, it is shown that the threshold where this space charge effect starts to be significant can be changed.

43 PARTICLE ACCELERATORS↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 300 kA Pulsed Power Supply for LBNF

The Long Baseline Neutrino Facility (LBNF) will produce the world’s most intense neutrino beam. While the magnetic horns are expected to be replaced, the LBNF horn power supply is expected to last the lifetime of the project, 30 years. Three series connected magnetic horns will require a 300kA, 800µs pulses at a rate of 1.4 pps to focus the beam. Prototyping proved the component choices and designs. Test results for a single cell and the full 32 cell system will be presented.

Jensen, C. C. [Fermilab] (ORCID:0000000212854906)↗

Transverse impedance measurement using response matrix fit method at APS.

The Advanced Photon Source (APS) is a third-generation synchrotron light source based on a 7-GeV electron storage ring. In third-generation light sources the synchrotron radiation is mainly produced in undulators. In order to achieve high photon flux and tunability, the magnet gap in undulators has to be as small as possible. Therefore, the undulators are installed on dedicated small-gap insertion device (ID) vacuum chambers. APS has thirty-five 5-m-long straight sections available for undulators. At the time of the measurements, there were 31 straight sections occupied with various insertion devices, and 4 straight sections were still empty. Most of the ID vacuum chambers have a 8-mm in-vacuum gap, and two chambers have a 5-mm gap. These narrow-gap vacuum chambers are believed to be the main source of the transverse impedance of the machine. One can measure the combined impedance by measuring the transverse tune slope with single-bunch current. Comparing this slope before and after installation of the narrow-gap vacuum chamber, one can deduce the impedance of the chamber. It is difficult to accurately measure the change in the tune slope after one or a few new ID chambers are installed. If several identical ID vacuum chambers are installed over a period of time, then one can estimate the contribution of one ID chamber. Over the last few years there have been a number of attempts to measure the impedance of separate components of accelerators. Phase-advance measurements from beam position monitor (BPM) turn-by-turn histories were used at LEP to measure the impedance distribution around the ring. Researches at LEP were able to fit average impedance in the long sections of the LEP arc and determine the impedance of the rf sections. The method was tried at APS; however, the accuracy of the measurements was not enough to determine the small impedance of a single ID vacuum chamber. There is also a different approach that uses local orbit bumps to probe different parts of an accelerator. The orbit bump method was done at BINP, APS, and ESRF. All these methods have one common feature: they employ the fact that the beam sees the impedance as an additional defocusing quadrupole whose strength depends on the beam current. At APS we use an orbit response matrix fit to determine the distribution of focusing errors around the machine, and then use these errors to calculate beta functions. Since the beam sees the impedance as a quadrupole whose strength depends on the beam current, the measurement of the beta functions with different currents could be used to determine the impedance distribution around the machine. This approach was first used at APS and reported in.

43 PARTICLE ACCELERATORS↗

Further Progress on a Design for a Super-B Interaction Region

We present an improved design for a SuperB interaction region. The new design minimizes local bending of the two colliding beams by separating all beam magnetic elements near the Interaction Point (IP). The total crossing angle at the IP is increased from 48 mrad to 60 mrad. The first magnetic element is a six slice Permanent Magnet (PM) quadrupole with an elliptical aperture allowing us to increase the vertical space for the beam. This magnet starts 36 cm from the Interaction Point (IP). This magnet is only seen by the Low-Energy Beam (LEB), the High-Energy Beam (HEB) has a drift space at this location. This allows the preliminary focusing of the LEB which has a smaller beta y* at the IP than the HEB. The rest of the final focusing for both beams is achieved by two super-conducting side-by-side quadrupoles (QD0 and QF1). These sets of magnets are enclosed in a warm bore cryostat located behind the PM quadrupole for the LEB. We describe this design for the interaction region.

43 PARTICLE ACCELERATORS↗