Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM CURRENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Upgrade of the electron beam ion trap in Shanghai

Over the last few years the Shanghai electron beam ion trap (EBIT) has been successfully redesigned and rebuilt. The original machine, developed under collaboration with the Shanghai Institute of Applied Physics, first produced an electron beam in 2005. It could be tuned with electron energies between 1 and 130 keV and beam current up to 160 mA. After several years of operation, it was found that several modifications for improvements were necessary to reach the goals of better electron optics, higher photon detection, and ion injection efficiencies, and more economical running costs. The upgraded Shanghai-EBIT is made almost entirely from Ti instead of stainless steel and achieves a vacuum of less than 10{sup −10} Torr, which helps to minimize the loss of highly changed ions through charge exchange. Meanwhile, a more compact structure and efficient cryogenic system, and excellent optical alignment have been of satisfactory. The magnetic field in the central trap region can reach up till 4.8 T with a uniformity of 2.77 × 10{sup −4}. So far the upgraded Shanghai-EBIT has been operated up to an electron energy of 151 keV and a beam current of up to 218 mA, although promotion to even higher energy is still in progress. Radiation from ions as highly charged as Xe{sup 53+,} {sup 54+} has been produced and the characterization of current density is estimated from the measured electron beam width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Change in Ion Beam Induced Current from Si Metal-Oxide-Semiconductor Capacitors after Gamma-Ray Irradiation

To investigate the effects of gamma-ray irradiation on transient current induced in MOS capacitors by heavy ion incidence, Si MOS capacitors were irradiated with gamma-rays up to 60.9 kGy(SiO2). The change in Transient Ion Beam Induced Current (TIBIC) signals due to gamma-ray irradiation was investigated using 15 MeV-oxygen ion microbeams. After gamma-ray irradiation, the peak current of the TIBIC signal vs. bias voltage curve shifted toward negative voltages. This shift can be interpreted in terms of the charge trapped in the oxide. In this dose range, no significant effects of the interface traps induced by gamma-ray irradiation on the TIBIC signals were observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion energy distribution in an electron beam ion trap inferred from simulations of the trapped ion cloud

For this work, we have inferred the energy distribution of trapped ions in an electron beam ion trap (EBIT) from simulations of the spatial distribution of Fe 13+ ions and a comparison with measured visible light images of the ion cloud. We simulated the cloud of Fe 13+ ions by computing ion trajectories in the EBIT for different ion energy distributions used to initialize the trajectories. We then performed a least-squares fit to infer the ion energy distribution that best reproduced the measured ion cloud. These best-fit distributions were typically non-Maxwellian. For electron beam energies of 395–475 eV and electron beam currents of 1–9 mA, we find that the average ion energy is in the range of 10–300 eV. We also find that the average ion energy increases with increasing beam current approximately as $\langle$E$\rangle$ ≈ 25 I e eV, where I e is the electron beam current in mA. We have also compared our results to Maxwell-Boltzmann-distribution ion clouds. We find that our best-fit non-thermal distributions have an $\langle$E$\rangle$ that is less than half that of the T from the best-fit Maxwell-Boltzmann distributions ($\langle$E$\rangle$/q)/T=0.41 ± 0.05.

74 ATOMIC AND MOLECULAR PHYSICS↗

Milliampere Beam Studies using High Polarization Photocathodes at the CEBAF Photoinjector

Extending the charge lifetime of today's spin polarized GaAs photoelectron guns from tens to thousands of Coulombs is a requirement for long-duration operation at milliampere beam current. There are two main approaches frequently considered to achieve this goal. The first is improving photo-gun vacuum, which provides a direct means to minimize the ill effects of ion bombardment and associated QE decay. In this contribution, we demonstrate the second: enhancing the charge lifetime at milliampere beam current by using large laser spots which serves to distribute ion damage over a larger region of the photocathode. The efficacy of this approach was presented at past workshops, but using bulk GaAs and green laser light without RF structure. In this contribution, highly polarized beam was produced from strained-superlattice GaAs/GaAsP photocathodes inside the 130 kV photo-gun at the CEBAF photoinjector, at beam currents from 0.5 to 1.5 mA and with a clear indication of lifetime enhancement using laser beams as large as ~8 mm2. However, when the laser beam size was increased beyond this diameter, further lifetime enhancement was not observed which highlights the importance of proper cathode/anode design to maintain loss-free beam delivery and the preservation of static vacuum conditions. In addition, this contribution presents electron beam polarization measurements at currents to 1 mA.

Grames, Joseph M.↗

Surface Production of Negative Ions by Positive Ions and Atoms in the Electron Suppressor Region

A simple model of the production of negative ions by positive ions and atoms from the source plasma striking a caesiated surface is presented. The model combines calculated flux rates for the ions and atoms at a surface with negative ion yields to determine the surface production rates. The model takes into account the relative potential between the plasma and the electron suppressor in calculating the surface production rates. By making the assumption that the surface production rates can be directly compared with the extracted beam current then the model is compared with data where the beam current has been measured as a function of electron suppressor bias and knowledge of the plasma parameters of the source also exists. At high bias voltages relative to the plasma potential only volume produced negative ions can be extracted as negative ions created on the surface cannot cross the sheath. The model reproduces features of the ion current dependence on electron suppressor bias. At high bias voltages where negative ions cannot leave the surface there is still an enhancement of the non-caesiated performance which may be attributed to volume production enhancement due to the presence of caesium in the plasma. This has implications for the replacement of caesium with other low work function materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Permanent-Magnet Microwave Ion Source For A Compact High-Yield Neutron Generator

We present recent work on the development of a microwave ion source that will be used in a high-yield compact neutron generator for active interrogation applications. The sealed tube generator will be capable of producing high neutron yields, 5x10{sup 11} n/s for D-T and {approx}1x10{sup 10} n/s for D-D reactions, while remaining transportable. We constructed a microwave ion source (2.45 GHz) with permanent magnets to provide the magnetic field strength of 87.5 mT necessary for satisfying the electron cyclotron resonance (ECR) condition. Microwave ion sources can produce high extracted beam currents at the low gas pressures required for sealed tube operation and at lower power levels than previously used RF-driven ion sources. A 100 mA deuterium/tritium beam will be extracted through a large slit (60x6 mm{sup 2}) to spread the beam power over a larger target area. This paper describes the design of the permanent-magnet microwave ion source and discusses the impact of the magnetic field design on the source performance. The required equivalent proton beam current density of 40 mA/cm{sup 2} was extracted at a moderate microwave power of 400 W with an optimized magnetic field.

43 PARTICLE ACCELERATORS↗

Characterization of an 8-cm Diameter Ion Source System

Results of tests characterizing an 8-cm diameter ion source are presented. The tests were conducted in three separate vacuum test facilities at the University of Alabama-Huntsville, Colorado State University, and L3 Communications' ETI division. Standard ion optics tests describing electron backstreaming and total-voltage-limited impingement current behavior as a function of beam current were used as guidelines for selecting operating conditions where more detailed ion beam measurements were performed. The ion beam was profiled using an in-vacuum actuating probe system to determine the total ion current density and the ion charge state distribution variation across the face of the ion source. Both current density and ExB probes were utilized. The ion current density data were used to obtain integrated beam current, beam flatness parameters, and general beam profile shapes. The ExB probe data were used to determine the ratio of doubly to singly charged ion current. The ion beam profile tests were performed at over six different operating points that spanned the expected operating range of the DAWN thrusters being developed at L3. The characterization tests described herein reveal that the 8-cm ion source is suitable for use in (a) validating plasma diagnostic equipment, (b) xenon ion sputtering and etching studies of spacecraft materials, (c) plasma physics research, and (d) the study of ion thruster optics at varying conditions.

Li, Zhongmin↗

Pulsed Electron Source with Grid Plasma Cathode and Longitudinal Magnetic Field for Modification of Material and Product Surfaces

The description and the main characteristics of the pulsed electron source “SOLO” developed on the basis of the plasma cathode with grid stabilization of the emission plasma boundary are presented. Тhe emission plasma is generated by a low-pressure arc discharge, and that allows to form the dense low-energy electron beam with a wide range of independently adjustable parameters of beam current pulses (pulse duration of 20–250 μs, pulse repetition rate of 1–10 s{sup –1}, amplitude of beam current pulses of 20–300 A, and energy of beam electrons of 5–25 keV). Тhe special features of generation of emission plasma by constricted low-pressure arc discharge in the grid plasma cathode partially dipped into a non-uniform magnetic field and of formation and transportation of the electron beam in a longitudinal magnetic field are considered. The application area of the electron source and technologies realized with its help are specified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Next Generation H- Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H{sup -} ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H{sup -} ion source based on an AlN ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA (60Hz, 1ms) have been observed and sustained currents >60 mA (60Hz, 1ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H{sup -} beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

33 ADVANCED PROPULSION SYSTEMS↗

A Mott polarimeter operating at MeV electron beam energies

We have developed a Mott electron polarimeter for the Mainzer microtron (MAMI) accelerator in Mainz, Germany. At beam energies ranging between 1.0 and 3.5 MeV two double focusing magnet spectrometers collect elastically backscattered electrons from gold targets. In spite of the small spectrometer acceptance, a sufficient statistical efficiency is achieved to provide very fast measurements if beam currents typical for experiments at MAMI are being used. High reproducibility is achieved, demonstrating that the results of asymmetry measurements are independent of the primary beam current in a range from 0.004 to 45 {mu}A at a level of <1% relative variation. Compared to low energy polarimeters of similar construction an improvement of a factor 2-3 in absolute accuracy seems possible.

43 PARTICLE ACCELERATORS↗

A 30-cm diameter bombardment thruster with a variable magnetic baffle.

Thruster performance and stability over a range of beam currents is a function of the hollow cathode propellant flow which depends in part on the baffle geometry. Variable magnetic baffles have been used to allow a change in baffle geometry to improve thruster performance and stability. Test results of a 30-cm thruster with magnetic baffle are presented. Thruster performance characteristics are analyzed to show how the magnetic baffle field strength can improve performance at a fixed beam current, as well as increase the range of ion beam current for throttling.

Bechtel, R. T.↗

Investigation of dislocations in Nb-doped SrTiO{sub 3} by electron-beam-induced current and transmission electron microscopy

This paper aims to clarify the electrical activities of dislocations in Nb-doped SrTiO{sub 3} substrates and the role of dislocations in the resistance switching phenomenon in Pt/SrTiO{sub 3} Schottky contacts. The electrical activities of dislocations have been studied by electron-beam-induced current (EBIC) technique. EBIC has found that dislocations can exhibit dark or bright contrast depending on their character and band bending condition. The character of dislocations has been analysed based on chemical etching and transmission electron microscopy. These data suggested that not all the dislocations contribute to the switching phenomenon. The active dislocations for resistance switching were discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantification of the effects of generation volume, surface recombination velocity, and diffusion length on the electron-beam-induced current and its derivative Determination of diffusion lengths in the low micron and submicron ranges

A systematic and quantitative analysis is carried out to investigate the effects of the shape (point, cube, Gaussian) and size of the generation volume, the surface recombination velocity, and the diffusion length on the electron-beam-induced current (EBIC) and its derivative (DEIC). Thick homogeneously doped samples exhibiting diffusion lengths in the low micron and submicron range are considered. The results are presented in computed EBIC curves as a function of scanning distance and of the ratio true diffusion length/effective diffusion length. Shown using these curves are: (1) a simple and yet rigorous method for the determination of the true diffusion length, taking into consideration all of the factors cited above, (2) a method for the rapid determination of the surface recombination velocity, (3) the condition under which the source shape becomes insignificant, and (4) a new value for the lower limit of the diffusion length which can be determined by the EBOC technique.

Luke, K. L.↗

Status of the RF-driven H{sup −} ion source for J-PARC linac

For the upgrade of the Japan Proton Accelerator Research Complex linac beam current, a cesiated RF-driven negative hydrogen ion source was installed during the 2014 summer shutdown period, with subsequent operations commencing on September 29, 2014. The ion source has been successfully operating with a beam current and duty factor of 33 mA and 1.25% (500 μs and 25 Hz), respectively. The result of recent beam operation has demonstrated that the ion source is capable of continuous operation for approximately 1100 h. The spark rate at the beam extractor was observed to be at a frequency of less than once a day, which is an acceptable level for user operation. Although an antenna failure occurred during operation on October 26, 2014, no subsequent serious issues have occurred since then.

43 PARTICLE ACCELERATORS↗

Next Generation H{sup -} Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H- ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H- ion source based on an A1N ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA(60 Hz, 1 ms) have been observed and sustained currents >60 mA(60 Hz, 1 ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H- beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

43 PARTICLE ACCELERATORS↗

Imaging interfacial electrical transport in graphene–MoS{sub 2} heterostructures with electron-beam-induced-currents

Heterostructure devices with specific and extraordinary properties can be fabricated by stacking two-dimensional crystals. Cleanliness at the inter-crystal interfaces within a heterostructure is crucial for maximizing device performance. However, because these interfaces are buried, characterizing their impact on device function is challenging. Here, we show that electron-beam induced current (EBIC) mapping can be used to image interfacial contamination and to characterize the quality of buried heterostructure interfaces with nanometer-scale spatial resolution. We applied EBIC and photocurrent imaging to map photo-sensitive graphene-MoS{sub 2} heterostructures. The EBIC maps, together with concurrently acquired scanning transmission electron microscopy images, reveal how a device's photocurrent collection efficiency is adversely affected by nanoscale debris invisible to optical-resolution photocurrent mapping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A low energy ion source for electron capture spectroscopy

We report on the design of an ion source for the production of single and double charged Helium ions with kinetic energies in the range from 300 eV down to 5 eV. The construction is based on a commercial sputter ion gun equipped with a Wien-filter for mass/charge separation. Retardation of the ions from the ionizer potential (2 keV) takes place completely within the lens system of the sputter gun, without modification of original parts. For 15 eV He{sup +} ions, the design allows for beam currents up to 30 nA, limited by the space charge repulsion in the beam. For He{sup 2+} operation, we obtain a beam current of 320 pA at 30 eV, and 46 pA at 5 eV beam energy, respectively. In addition, operating parameters can be optimized for a significant contribution of metastable He*{sup +} (2s) ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution planar electron beam induced current in bulk diodes using high-energy electrons

Understanding the impact of high-energy electron radiation on device characteristics remains critical for the expanding use of semiconductor electronics in space-borne applications and other radiation harsh environments. Here in this paper, we report on in situ measurements of high-energy electron radiation effects on the hole diffusion length in low threading dislocation density homoepitaxial bulk n-GaN Schottky diodes using electron beam induced current (EBIC) in high-voltage scanning electron microscopy mode. Despite the large interaction volume in this system, quantitative EBIC imaging is possible due to the sustained collimation of the incident electron beam. This approach enables direct measurement of electron radiation effects without having to thin the specimen. Using a combination of experimental EBIC measurements and Monte Carlo simulations of electron trajectories, we determine a hole diffusion length of 264 ± 11 nm for n-GaN. Irradiation with 200 kV electron beam with an accumulated dose of 24 × 10 16 electrons cm -2 led to an approximate 35% decrease in the minority carrier diffusion length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗