Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Atomic Physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Spectroscopic diagnostics for liquid lithium divertor studies on National Spherical Torus Experiment

The use of lithium-coated plasma facing components for plasma density control is studied in the National Spherical Torus Experiment (NSTX). A recently installed liquid lithium divertor (LLD) module has a porous molybdenum surface, separated by a stainless steel liner from a heated copper substrate. Lithium is deposited on the LLD from two evaporators. Two new spectroscopic diagnostics are installed to study the plasma surface interactions on the LLD: (1) A 20-element absolute extreme ultraviolet (AXUV) diode array with a 6 nm bandpass filter centered at 121.6 nm (the Lyman-{alpha} transition) for spatially resolved divertor recycling rate measurements in the highly reflective LLD environment, and (2) an ultraviolet-visible-near infrared R=0.67 m imaging Czerny-Turner spectrometer for spatially resolved divertor D I, Li I-II, C I-IV, Mo I, D{sub 2}, LiD, CD emission and ion temperature on and around the LLD module. The use of photometrically calibrated measurements together with atomic physics factors enables studies of recycling and impurity particle fluxes as functions of LLD temperature, ion flux, and divertor geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beyond low beta-decay Q values

Beta decays with low Q values can be utilized in the quest to determine the neutrino mass scale. This is being realized in two experiments, KATRIN and MARE, using tritium and {sup 187}Re, respectively. The beta-decay of {sup 187}Re had the lowest known Q value until 2005, when the beta decay of {sup 115}In to the first excited state of {sup 115}Sn was discovered in Gran Sasso underground laboratory. Last year two independent ion trap measurements confirmed that this decay breaks the former record by an order of magnitude.Our theoretical study on this tiny decay channel complemented the experimental effort by the JYFLTRAP group in Finland and HADES underground laboratory in Belgium. A significant discrepancy between the experimental and theoretical results was found. This might be explained by various atomic contributions known to grow larger as the Q value decreases. However, the traditional recipes for taking these effects into account break down on this new ultra-low Q value regime, providing new challenges for theorists on the borderline between nuclear and atomic physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Target-heating effects on the K{sub {alpha}{sub 1{sub ,{sub 2}}}}-emission spectrum from solid targets heated by laser-generated hot electrons

Target-heating effects on the K{sub {alpha}{sub 1{sub ,{sub 2}}}}-emission spectrum from small-mass Cu targets irradiated with 1-ps pulses focused to intensities >10{sup 18} W/cm{sup 2} have been observed. A collisional-radiative atomic physics model is unable to reproduce the time-integrated K{sub {alpha}{sub 1{sub ,{sub 2}}}}-emission spectrum from the smallest-mass targets when calculated with a single, time-independent thermal-electron temperature. When time-dependent heating to several hundred electron volts is included in the model, the synthetic spectra better reproduce the main observed spectral features.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stimulated Raman scatter analyses of experiments conducted at the National Ignition Facility

Recent experiments conducted at the National Ignition Facility achieved two main goals: providing radiation drive and symmetry suitable for subsequent ignition experiments. Of the many diagnostics fielded, one provided a time-resolved wavelength spectrum of light reflected from the target by stimulated Raman scatter (SRS). SRS occurs when incident light reflects off self-generated electron plasma waves. Analyses indicate that synthetic SRS spectra better match those of experiments when an atomic physics model with greater emissivity is utilized in target modeling, along with less inhibited electron transport (higher flux, with, ideally, nonlocal electron transport). With these models, SRS occurs in a target region where nearest-neighbor quads of laser beams significantly overlap the diagnosed quad. This increases SRS gain at lower density (lower wavelength), a feature consistent with experimental results. Inclusion of this effect of multiple quads sharing a reflected SRS light wave has resulted in improved capabilities used to successfully predict (preshot) the SRS spectrum from the first target driven with 1.25 MJ of laser energy. Additional resonant amplification of SRS light in the overlap intensity region is demonstrated in beam propagation simulations. Such effects will be reduced in a target optimized for these less dense and cooler plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular and negative ion production by a standard electron cyclotron resonance ion source

Molecular and negative ion beams, usually produced in special ion sources, play an increasingly important role in fundamental and applied atomic physics. The ATOMKI-ECRIS is a standard ECR ion source, designed to provide highly charged ion (HCI) plasmas and beams. In the present work, H{sup -}, O{sup -}, OH{sup -}, O{sub 2}{sup -}, C{sup -}, C{sub 60}{sup -} negative ions and H{sub 2}{sup +}, H{sub 3}{sup +}, OH{sup +}, H{sub 2}O{sup +}, H{sub 3}O{sup +}, O{sub 2}{sup +} positive molecular ions were generated in this HCI-ECRIS. Without any major modification in the source and without any commonly applied tricks (such as usage of cesium or magnetic filter), negative ion beams of several {mu}A and positive molecular ion beams in the mA range were successfully obtained.

43 PARTICLE ACCELERATORS↗

Numerical simulation of thin-shell direct drive DHe3-filled capsules fielded at OMEGA

Thin-shell deuterium-helium-3 (DHe{sup 3}) filled glass capsules on the Omega laser provide a fast-implosion experimental platform for developing separate time-resolved measurements of ion, electron, and radiation temperatures in nonequilibrium plasmas. Dynamically significant non-local thermodynamic equilibrium (NLTE) conditions are created by the addition of xenon dopant to the DHe{sup 3} gas fill, in quantities sufficient to have an impact on yields, compression, and cooling rates. The high-Z dopant dramatically increases the radiative cooling rate in the plasma, allowing it to collapse in compressions that can be an order of magnitude higher than in undoped capsules. A baseline LASNEX simulation model using detailed configuration accounting NLTE atomic physics shows very good agreement with the data for doped as well as undoped capsules, while other models either underpredict or overpredict the radiative cooling enhancement. The baseline model captures the behavior of the capsule when the D:He{sup 3} ratio is varied well away from equimolar, suggesting no yield anomaly with either nearly pure deuterium or He{sup 3} fills. Variation of the electron-ion coupling in the baseline simulation model shows agreement with the data for a coupling multiplier that is within 20% of unity. Reliably inferring electron-ion coupling strength from the data is complicated by uncertainties in the hydrodynamic mix and other parameters, but many of these can be mitigated in follow-on experiments at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-keV x-ray sources from metal-lined cylindrical hohlraums

As multi-keV x-ray sources, plastic hohlraums with inner walls coated with titanium, copper, and germanium have been fired on Omega in September 2009. For all the targets, the measured and calculated multi-keV x-ray power time histories are in a good qualitative agreement. In the same irradiation conditions, measured multi-keV x-ray conversion rates are {approx}6%-8% for titanium, {approx}2% for copper, and {approx}0.5% for germanium. For titanium and copper hohlraums, the measured conversion rates are about two times higher than those given by hydroradiative computations. Conversely, for the germanium hohlraum, a rather good agreement is found between measured and computed conversion rates. To explain these findings, multi-keV integrated emissivities calculated with RADIOM [M. Busquet, Phys. Fluids 85, 4191 (1993)], the nonlocal-thermal-equilibrium atomic physics model used in our computations, have been compared to emissivities obtained from different other models. These comparisons provide an attractive way to explain the discrepancies between experimental and calculated quantitative results.

36 MATERIALS SCIENCE↗

Temporally resolved characterization of shock-heated foam target with Al absorption spectroscopy for fast electron transport study

The CH foam plasma produced by a laser-driven shock wave has been characterized by a temporally resolved Al 1s-2p absorption spectroscopy technique. A 200 mg/cm{sup 3} foam target with Al dopant was developed for this experiment, which used an OMEGA EP [D. D. Meyerhofer et al., J. Phys.: Conf. Ser. 244, 032010 (2010)] long pulse beam with an energy of 1.2 kJ and 3.5 ns pulselength. The plasma temperatures were inferred with the accuracy of 5 eV from the fits to the measurements using an atomic physics code. The results show that the inferred temperature is sustained at 40-45 eV between 6 and 7 ns and decreases to 25 eV at 8 ns. 2-D radiation hydrodynamic simulations show a good agreement with the measurements. Application of the shock-heated foam plasma platform toward fast electron transport experiments is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatic storage ring with focusing provided by the space charge of an electron plasma

Electrostatic storage rings are used for a variety of atomic physics studies. An advantage of electrostatic storage rings is that heavy ions can be confined. An electrostatic storage ring that employs the space charge of an electron plasma for focusing is described. An additional advantage of the present concept is that slow ions, or even a stationary ion plasma, can be confined. The concept employs an artificially structured boundary, which is defined at present as one that produces a spatially periodic static field such that the spatial period and range of the field are much smaller than the dimensions of a plasma or charged-particle beam that is confined by the field. An artificially structured boundary is used to confine a non-neutral electron plasma along the storage ring. The electron plasma would be effectively unmagnetized, except near an outer boundary where the confining electromagnetic field would reside. The electron plasma produces a radially inward electric field, which focuses the ion beam. Self-consistently computed radial beam profiles are reported.

43 PARTICLE ACCELERATORS↗

Nucleon measurements at the precision frontier

We comment on nucleon measurements at the precision frontier. As examples of what can be learned, we concentrate on three topics, which are parity violating scattering experiments, the proton radius puzzle, and the symbiosis between nuclear and atomic physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of particle diffusion and suprathermal electrons in a magnetized helium plasma column

Studying radiative properties of magnetized helium plasma via high-resolution spectroscopy identified close correlations between the particle diffusion and suprathermal electrons for different modes of operation of the MISTRAL installation. The standard diagnostic emission lines in neutral helium (1s3d {sup 3}D-1s2p {sup 3}P, 1s3s {sup 3}S-1s2p {sup 3}P, 1s3d {sup 1}D-1s2p {sup 1}P, and 1s3s {sup 1}S-1s2p {sup 1}P) show anomalous ratios that are related to enhanced particle diffusion and suprathermal electron generation. The supplementary investigation of singlet/triplet Rydberg series (transitions 1snd {sup 3}D-1s2p {sup 3}P and 1s5p {sup 1}P-1s2s {sup 1}S) as well as ionic lines (HeII, transitions n = 3–4 at 469 nm and n = 4–6 at 656 nm) allowed quantitative characterization. Simulations carried out with the atomic physics code SOPHIA demonstrate that simultaneous implementation of diffusion processes and suprathermal electrons matches all experimental findings. Single consideration, however, of either diffusion or hot electrons is in contradiction to the proposed extended set of HeI and HeII emission lines. The high precision achieved with the LSJ-split level structure of SOPHIA coupled to Langmuir probe measurements allowed to conclude to a Bohm type diffusion in MISTRAL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The universe in the laboratory - Nuclear astrophysics opportunity at the facility for antiproton and ion research

In the next years the Facility for Antiproton and Ion Research FAIR will be constructed at the GSI Helmholtzze-ntrum für Schwerionenforschung in Darmstadt, Germany. This new accelerator complex will allow for unprecedented and pathbreaking research in hadronic, nuclear, and atomic physics as well as in applied sciences. This manuscript will discuss some of these research opportunities, with a focus on supernova dynamics and nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A method for determining poloidal rotation from poloidal asymmetry in toroidal rotation (invited)

A new diagnostic has been developed on DIII-D that determines the impurity poloidal rotation from the poloidal asymmetry in the toroidal angular rotation velocity. This asymmetry is measured with recently added tangential charge exchange viewchords on the high-field side of the tokamak midplane. Measurements are made on co- and counter-current neutral beams, allowing the charge exchange cross section effect to be measured and eliminating the need for atomic physics calculations. The diagnostic implementation on DIII-D restricts the measurement range to the core (r/a < 0.6) where, relative to measurements made with the vertical charge exchange system, the spatial resolution is improved. Significant physics results have been obtained with this new diagnostic; for example, poloidal rotation measurements that significantly exceed neoclassical predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and non-local thermodynamic equilibrium modeling of mid-Z plasma emission

The x-ray yields from laser-irradiated thin foils of iron, copper, zinc, and germanium have been measured in the soft and multi-keV x-ray ranges at the OMEGA laser at the Laboratory for Laser Energetics. The incident laser power had a pre-pulse to enhance the x-ray emission of a 1 ns flat-top main pulse. The experimental results have been compared with post-shot simulations performed with the two-dimensional radiation-hydrodynamics code FCI2. A new non-local thermodynamic equilibrium model, NOO-RAD, have been incorporated into FCI2. In this approach, the plasma ionization state is in-line calculated by the atomic physics NOHEL package. In the soft x-ray bands, both simulations using RADIOM [M. Busquet, Phys. Fluids B 5, 4191 (1993)] and NOO-RAD clearly over-predict the powers and energies measured by a broad-band spectrometer. In one case (the iron foil), the discrepancy between the measured and simulated x-ray output is nevertheless significantly reduced when NOO-RAD is used in the simulations. In the multi-keV x-ray bands, the simulations display a strong sensitivity to the coupling between the electron thermal conductivity and the NLTE models, and for some particular combinations of these, provide a close match to the measured emission. The comparison between the measured and simulated H-like to He-like line-intensity ratios deduced from high-resolution spectra indicates higher experimental electron temperatures were achieved, compared to the simulated ones. Measurements of the plasma conditions have been achieved using the Thomson-scattering diagnostic. The electron temperatures are found to range from 3 to 5 keV at the end of the laser pulse and are greater than predicted by the simulations. The measured flow velocities are in reasonable agreement with the calculated ones. This last finding gives us confidence in our numerical predictions for the plasma parameters, which are over that time mainly determined by hydrodynamics, such as the mass densities and the ion temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft X-ray emission from laser-irradiated gold foils

Here, this paper reports measurements of soft-x-ray emission from gold foils irradiated by 6 ns laser pulses, and analysis and simulations of the observations. These foils can be used as x-ray sources to drive a wide range of experiments. A multichannel, photodiode array measured the time-resolved, soft-x-ray emission. A soft-x-ray framing camera imaged the emission in selected energy bands. Foil thicknesses were from 0.5 to 1.5 μm. The imaging data show that the region emitting soft x-rays grows throughout the laser drive, on both the front and rear surfaces. Analysis of the emitted radiation flux from the rear surface, taking the time-dependent spot size into account, showed that the peak effective temperature of 0.5-μm-thick foils is near 88 eV, while that of 0.75-μm-thick foils is near 78 eV. A Monte Carlo method was used to evaluate the component of the uncertainty in the effective temperature introduced by variations in signal voltages and by uncertainty in the size of the emitting spot. This was found to be near ±2 eV in most cases. Simple theoretical considerations explain the main features of the observations. The Florence code, working with atomic physics from sophisticated models, proved able to reproduce the main features of the observed spectra with 1D simulations in which the laser energy flux was adjusted on the basis of the observed lateral spreading of energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthetic diagnostic for assessing spatial averaging of charge exchange recombination spectroscopy measurements

A synthetic charge exchange recombination spectroscopy diagnostic based on the FIDASIM modeling suite has been created for the DIII-D tokamak. This synthetic diagnostic assumes that the ions have Maxwellian distribution functions on each flux surface and models emission from charge exchange events between the beam neutrals and a fully ionized impurity. This work was motivated by the observation of non-Gaussian spectra that may be caused by spatial averaging, atomic physics, or non-Maxwellian distribution functions. Measurements of non-Gaussian spectra commonly observed in the high confinement mode pedestal and in plasmas with large core gradients are compared to the synthetic diagnostic. Spatial averaging alone cannot account for the observations in these two cases, opening up the possibility of there being other causes such as non-Maxwellian distribution functions. Here, the synthetic diagnostic has also been used to resolve a long-standing issue: it is shown that the lower temperatures measured by using vertical view chords relative to tangential view chords are due to increased spatial averaging for vertical views due to the DIII-D neutral beams being approximately twice as tall as they are wide.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗