Transient performance of fan engine with water ingestion
In a continuing investigation on effects of rain-water ingestion into bypass fan engines, it is shown that the performance of axial-flow compressors and fans is fundamentally time-dependent during ingestion of water. A code named WINCOF-I has been developed for establishing the performance of axial-flow turbomachinery operating with air-water vapor-water droplet-water film mixture, Illustrative examples of predictions and effects are provided for the case of the air-compression system of a generic bypass fan engine. Utilizing performance maps so-generated, the effects of water ingestion into the generic engine have been determined under test cell conditions simulating ingestion, flight operation (altitude and flight Mach number), and power-demand setting.