Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Space telescope pointing control

The Space Telescope pointing control system is designed to meet the fine pointing performance of 0.007 arc-sec stability, maneuver the telescope 90 deg in 18 min, or less, and provide the capability for deployment from, and retrieval by, the space shuttle. The pointing control system objectives are met using fine guidance sensors for attitude information, reaction wheel assemblies sized to provide both the torque required for pointing, and magnetometers and magnetic torquers for momentum management. A digital computer is used to calculate the control law, attitude reference, momentum management law, and command generator. The command generator shapes the acceleration and incremental angle commands to the control system to limit structural mode excitation. The control techniques are briefly discussed.

Dougherty, Hugh↗

Software Development for a CompactRIO-Based Wire Scanner Control and Data Acquisition SYstem

The Beam Diagnostics and Instrumentation Team at the Los Alamos Neutron Science Center is developing a wire scanner data acquisition and control system with a National Instrument's compactRIO at its core. For this application, the compactRIO controller not only requires programming the FPGA and RT computer internal to the compactRIO, but also requires programming a client computer and a touch panel display. This article will summarize the hardware interfaces and describe the software design approach utilized for programming and interfacing the four systems together in order to fulfill the design requirements and promote reliable interoperability.

42 ENGINEERING↗

Design and performance of the propulsion system for the quiet short-haul research aircraft /QSRA/

This paper describes the design and performance of the Quiet Short-Haul Research Aircraft (QSRA) propulsion system. A discussion of the mixed-flow boundary layer control (BLC) system, which uses high and low pressure engine bleed air, is included. This system seriously affected propulsion system performance, particularly engine acceleration characteristics, requiring an integration of BLC system and powerplant controls. Funding limitations for the QSRA Project prevented extensive full-scale testing and systems mockups, resulting in a high reliance on small-scale tests and analytical techniques. Ground tests of the actual aircraft systems showed that the extrapolation of small-scale tests and analytical techniques were in good agreement with measured full-scale results.

Shovlin, M. D.↗

g-LIMIT Status Briefing

For many microgravity science experiments in the International Space Station, the ambient acceleration environment will be exceed desirable levels. To provide a more quiescent acceleration environment to the microgravity payloads, a vibration isolation system named g-LIMIT (GLovebox Integrated Microgravity Isolation Technology) is being designed. g-LIMIT is a sub-rack level isolation system that can be tailored to a variety of applications. Scheduled for launch on the UF-1 mission, the initial implementation of g-LIMIT will be a Characterization Test in the Microgravity Science Glovebox (MSG). g-LIMIT will be available to glovebox investigators immediately after characterization testing. Standard MSG structural and umbilical interfaces will be used so that the isolation mount is transparent to the user with no additional accommodation requirements. g-LIMIT consists of three integrated isolator modules, each of which is comprised of a dual axis actuator, two axes of acceleration sensing, two axes of position sensing, control electronics, and data transmission capabilities in a minimum-volume package. In addition, this system provides the unique capability for measuring absolute acceleration of the experiment independent of accelerometers as a by-product of the control system and will have the capability of generating pristine accelerations to enhance experiment operations.

Whorton, Mark↗

Beamline Control and Instrumentation System using Industrial Interface Techniques

How should a beamline be designed, which satisfies the needs and requirements of scientists and is easy to build and operate? Today, most control and instrumentation systems for beamlines are based on scientific requirements. Scientific details of the beamline, e.g. vacuum and beam physics details; are usually extensively described. However, control system specifications are often reduced to few requirements, e.g. which beam-related device to use. Lots of these systems work perfectly from the physicist's point of view, but are hard to bring into service and operate and difficult to extend with additional equipment. To overcome this, the engineering company ENZ has developed components using industrial standard interfaces to guarantee high flexibility for equipment extension. Using special interface boards and galvanic isolation offers increased stability of motion control axes. This saves resources during commissioning and service. A control system was developed and installed at a Soft-X-ray beamline at ASP Melbourne. It is operated under EPICs on distributed embedded IOC's based on PC-hardware. Motion and vacuum systems, measurement devices, e.g. a Low-Current Monitor (LoCuM) for beam position monitoring, and parts of the equipment protection system were developed and most of them tested in cooperation with DELTA at the Technical University of Dortmund.

43 PARTICLE ACCELERATORS↗

Transverse emittance and phase space program developed for use at the Fermilab A0 Photoinjector

The Fermilab A0 Photoinjector is a 16 MeV high intensity, high brightness electron linac developed for advanced accelerator R&D. One of the key parameters for the electron beam is the transverse beam emittance. Here we report on a newly developed MATLAB based GUI program used for transverse emittance measurements using the multi-slit technique. This program combines the image acquisition and post-processing tools for determining the transverse phase space parameters with uncertainties. An integral part of accelerator research is a measurement of the beam phase space. Measurements of the transverse phase space can be accomplished by a variety of methods including multiple screens separated by drift spaces, or by sampling phase space via pepper pots or slits. In any case, the measurement of the phase space parameters, in particular the emittance, can be drastically simplified and sped up by automating the measurement in an intuitive fashion utilizing a graphical interface. At the A0 Photoinjector (A0PI), the control system is DOOCS, which originated at DESY. In addition, there is a library for interfacing to MATLAB, a graphically capable numerical analysis package sold by The Mathworks. It is this graphical package which was chosen as the basis for a graphical phase space measurement system due to its combination of analysis and display capabilities.

43 PARTICLE ACCELERATORS↗

Intelligent Optimization of the Digital Low Level RF Control System for LANSCE LINAC

The LINAC at the Los Alamos Neutron Science Center (LANSCE) accelerates protons from 750 keV to its final energy at 800 MeV via 48 radio frequency (RF) modules. However, the startup and recovery process of the low-level RF (LLRF) systems, the primary controls for the RF modules, cost significant time for the beam operation, while the process itself is highly prone to human errors. With the new conversion from the analog LLRF (aLLRF) to digital LLRF (dLLRF) system under the recent LANSCE Modernization Project, new approaches with the new dLLRF capabilities can be achieved to address this issue. We propose to develop an intelligent optimization scheme that can significantly lower the downtime caused by the LLRF systems. This directly address the MFR problem statement that asks for “innovative engineering improvements to ancillary systems such as RF and pulsed power that improve reliability, maintainability, and/or performance.”

43 PARTICLE ACCELERATORS↗

Proton beam quality enhancement by spectral phase control of a PW-class laser system

We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary Report of Mission Acceleration Measurements for STS-78. Launched June 20, 1996

The microgravity environment of the Space Shuttle Columbia was measured during the STS-78 mission using accelerometers from three different instruments: the Orbital Acceleration Research Experiment, the Space Acceleration Measurement System and the Microgravity Measurement Assembly. The quasi-steady environment was also calculated in near real-time during the mission by the Microgravity Analysis Workstation. The Orbital Acceleration Research Experiment provided investigators with real-time quasi-steady acceleration measurements. The Space Acceleration Measurement System recorded higher frequency data on-board for post-mission analysis. The Microgravity Measurement Assembly provided investigators with real-time quasi-steady and higher frequency acceleration measurements. The Microgravity Analysis Workstation provided calculation of the quasi-steady environment. This calculation was presented to the science teams in real-time during the mission. The microgravity environment related to several different Orbiter, crew and experiment operations is presented and interpreted in this report. A radiator deploy, the Flight Control System checkout, and a vernier reaction control system reboost demonstration had minimal effects on the acceleration environment, with excitation of frequencies in the 0.01 to 10 Hz range. Flash Evaporator System venting had no noticeable effect on the environment while supply and waste water dumps caused excursions of 2 x lO(exp -6) to 4 x 10(exp -6) g in the Y(sub b) and Z(sub b) directions. Crew sleep and ergometer exercise periods can be clearly seen in the acceleration data, as expected. Accelerations related to the two Life Science Laboratory Equipment Refrigerator/Freezers were apparent in the data as are accelerations caused by the Johnson Space Center Projects Centrifuge. As on previous microgravity missions, several signals are present in the acceleration data for which a source has not been identified. The causes of these accelerations are under investigation.

Hakimzadeh, Roshanak↗

Design and piloted simulation evaluation of integrated flight/propulsion controls for STOVL aircraft

Integrated flight/propulsion control systems have been designed for operation of STOVL aircraft over the low speed powered-lift flight envelope. The control system employs command modes for attitude, flightpath angle and flightpath acceleration during transition, and translational velocity command for hover and vertical landing. The command modes and feedback control are implemented in the form of a state-rate feedback implicit model follower to achieve the desired flying qualities and to suppress the effects of external disturbances and variations in the aircraft characteristics over the low speed envelope. A nonlinear inverse system was used to translate the output from these commands and feedback control into commands for the various aerodynamic and propulsion control effectors that are employed in powered-lift flight. Piloted evaluations of these STOVL integrated control designs have been conducted on Ames Research Center's Vertical Motion Simulator to assess flying qualities over the low-speed flight envelope. Results indicate that Level 1 flying qualities are achieved with this control system concept for each of these low-speed operations over a wide range of wind, atmospheric turbulence, and visibility conditions.

Franklin, James A.↗

Control System Design for Automatic Cavity Tuning Machines

A series of four automatic tuning machines for 9-cell TESLA-type cavities are being developed and fabricated in a collaborative effort among DESY, FNAL, and KEK. These machines are intended to support high-throughput cavity fabrication for construction of large SRF-based accelerator projects. Two of these machines will be delivered to cavity vendors for the tuning of XFEL cavities. The control system for these machines must support a high level of automation adequate for industrial use by non-experts operators. This paper describes the control system hardware and software design for these machines.

43 PARTICLE ACCELERATORS↗

Dose Control System in the Optima XE Single Wafer High Energy Ion Implanter

Photoresist outgassing can significantly compromise accurate dosimetry of high energy implants. High energy implant even at a modest beam current produces high beam powers which create significantly worse outgassing than low and medium energy implants and the outgassing continues throughout the implant due to the low dose in typical high energy implant recipes. In the previous generation of high energy implanters, dose correction by monitoring of process chamber pressure during photoresist outgassing has been used. However, as applications diversify and requirements change, the need arises for a more versatile photoresist correction system to match the versatility of a single wafer high energy ion implanter. We have successfully developed a new dosimetry system for the Optima XE single wafer high energy ion implanter which does not require any form of compensation due to the implant conditions. This paper describes the principles and performance of this new dose system.

43 PARTICLE ACCELERATORS↗

Neutron Imaging Control Report: FY 2016

During the 2016 fiscal year, work began on the supervision and control systems for the neutron source currently under construction in the B194 accelerator caves. This source relies on a deuteron beam colliding with a high-speed stream of deuterium gas to create neutrons, which poses significant technical challenges. To help overcome those challenges, an integrated, operator-focused control architecture is required to collect and assimilate disparate data from a variety of measurement points, as well as provide the means to remotely control the system hardware.

43 PARTICLE ACCELERATORS↗

Neutron interrogation systems using pyroelectric crystals and methods of preparation thereof

According to one embodiment, an apparatus includes a pyroelectric crystal, a deuterated or tritiated target, an ion source, and a common support coupled to the pyroelectric crystal, the deuterated or tritiated target, and the ion source. In another embodiment, a method includes producing a voltage of negative polarity on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using a voltage of the pyroelectric crystal and/or an HGI surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other apparatuses and methods are presented as well.

36 MATERIALS SCIENCE↗

Poster — Thur Eve — 28: Enabling trajectory-based radiotherapy on a TrueBeam accelerator with the Eclipse treatment planning system

The TrueBeam linear accelerator platform has a developer's mode which permits the user dynamic control over many of the machine's mechanical and radiation systems. Using this research tool, synchronous couch and gantry motion can be programmed to simulate isocentric treatment with a shortened SAD, with benefits such as smaller projected MLC leaf widths and an increased dose rate. In this work, water tank measurements were used to commission a virtual linear accelerator with an 85 cm SAD in Eclipse, from which several arc-based radiotherapy treatments were generated, including an inverse optimized VMAT delivery. For each plan, the pertinent treatment delivery information was extracted from control points specified in the Eclipse-exported DICOM files using the pydicom package in Python, allowing construction of an XML control file. The dimensions of the jaws and MLC positions, defined for an 85 cm SAD in Eclipse, were scaled for delivery on a conventional SAD linear accelerator, and translational couch motion was added as a function of gantry angle to simulate delivery at 85 cm SAD. Ionization chamber and Gafchromic film measurements were used to compare the radiation delivery to dose calculations in Eclipse. With the exception of the VMAT delivery, ionization chamber measurements agreed within 3.3% of the Eclipse calculations. For the VMAT delivery, the ionization chamber was located in an inhomogeneous region, but gamma evaluation of the Gafchromic film plane resulted in a 94.5% passing rate using criteria of 3 mm/3%. The results indicate that Eclipse calculation infrastructure can be used.

07 ISOTOPE AND RADIATION SOURCES↗

Project WISH: The Emerald City

Phase 3 of Project WISH saw the evolution of the Emerald City (E-City) from a collection of specialized independent analyses and ideas to a working structural design integrated with major support systems and analyses. Emphasis was placed on comparing and contrasting the closed and open cycle gas core nuclear rocket engines to further determine the optimum propulsive system for the E-City. Power and thermal control requirements were then defined and the question of how to meet these requirements was addressed. Software was developed to automate the mission/system/configuration analysis so changes dictated by various subsystem constraints could be managed efficiently and analyzed interactively. In addition, the liquid hydrogen propellant tank was statically designed for minimum mass and shape optimization using a finite element modeling package called SDRC I-DEAS. Spoke and shaft cross-sectional areas were optimized on ASTROS (Automated Structural Optimization System) for mass minimization. A structural dynamic analysis of the optimal structure also conducted using ASTROS enabled a study of the modes, frequencies, displacements, and accelerations of the E-City. Finally, the attitude control system design began with an initial mass moment of inertia analysis and was then designed and optimized using linear quadratic regulator control theory.

Oz, Hayrani↗

Japanese Structure Survey of Radiation Oncology in 2007 Based on Institutional Stratification of Patterns of Care Study

Purpose: To evaluate the ongoing structure of radiation oncology in Japan in terms of equipment, personnel, patient load, and geographic distribution to identify and improve any deficiencies. Methods and Materials: A questionnaire-based national structure survey was conducted from March to December 2008 by the Japanese Society of Therapeutic Radiology and Oncology (JASTRO). These data were analyzed in terms of the institutional stratification of the Patterns of Care Study. Results: The total numbers of new cancer patients and total cancer patients (new and repeat) treated with radiation in 2007 were estimated at 181,000 and 218,000, respectively. There were 807 linear accelerator, 15 telecobalt, 46 Gamma Knife, 45 {sup 60}Co remote-controlled after-loading, and 123 {sup 192}Ir remote-controlled after-loading systems in actual use. The linear accelerator systems used dual-energy function in 539 units (66.8%), three-dimensional conformal radiation therapy in 555 (68.8%), and intensity-modulated radiation therapy in 235 (29.1%). There were 477 JASTRO-certified radiation oncologists, 826.3 full-time equivalent (FTE) radiation oncologists, 68.4 FTE medical physicists, and 1,634 FTE radiation therapists. The number of interstitial radiotherapy (RT) administrations for prostate, stereotactic body radiotherapy, and intensity-modulated radiation therapy increased significantly. Patterns of Care Study stratification can clearly identify the maturity of structures based on their academic nature and caseload. Geographically, the more JASTRO-certified physicians there were in a given area, the more RT tended to be used for cancer patients. Conclusions: The Japanese structure has clearly improved during the past 17 years in terms of equipment and its use, although a shortage of personnel and variations in maturity disclosed by Patterns of Care Study stratification were still problematic in 2007.

62 RADIOLOGY AND NUCLEAR MEDICINE↗