Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRFLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Assessment of Urban Aerial Taxi with Cryogenic Components Under Design Environment for Novel Vertical Lift Vehicles (DELIVER)

Assessing the potential to bring 100 years of aeronautics knowledge to the entrepreneurs desktop to enable a design environment for emerging vertical lift vehicles is one goal for the NASA's Design Environment for Novel Vertical Lift Vehicles (DELIVER). As part of this effort, a system study was performed using a notional, urban aerial taxi system to better understand vehicle requirements along with the tools and methods capability to assess these vehicles and their subsystems using cryogenic cooled components. The baseline was a vertical take-off and landing (VTOL) aircraft, with all-electric propulsion system assuming 15 year technology performance levels and its capability limited to a pilot with one or two people and cargo. Hydrocarbon-fueled hybrid concepts were developed to improve mission capabilities. The hybrid systems resulted in significant improvements in maximum range and number of on demand mobility (ODM) missions that could be completed before refuel or recharge. An important consideration was thermal management, including the choice for air-cooled or cryogenic cooling using liquid natural gas (LNG) fuel. Cryogenic cooling for critical components can have important implications on component performance and size. Thermal loads were also estimated, subsequent effort will be required to verify feasibility for cooling airflow and packaging. LNG cryogenic cooling of selected components further improved vehicle range and reduced thermal loads, but the same concerns for airflow and packaging still need to be addressed. The use of the NASA Design and Analysis of Rotorcraft (NDARC) tool for vehicle sizing and mission analysis appears to be capable of supporting analyses for present and future types of vehicles, missions, propulsion, and energy sources. Further efforts are required to develop verified models for these new types of propulsion and energy sources in the size and use envisioned for these emerging vehicle and mission classes.

thermal analysis↗

Total Temperature Measurements using a Rearward Facing Probe in Supercooled Liquid Droplet and Ice Crystal Clouds

This paper presents an analysis of local total temperature and humidity experimental measurement taken in atmospheric ice cloud flows. The measurements were obtained in a series of tests in NASA's Propulsion Systems Laboratory. The probe used in the tests is referred to as the Rearward Facing Probe which was designed to mitigate the contamination effects of ice accretion and ingestion into the probe. The data provided important insights in the interaction of the ice cloud and the atmospheric flow. For the majority of the test runs, small temperature drops in the range of 0.6 to 2.8 C and up to 1.5 g/kg of water vapor rise were found as a result of the interaction. Under certain very low temperature or high TWC conditions, the interaction with the cloud produced a warming of the airflow. A thermal model based on evaporative and convective heat transfer mechanisms between the spray droplets and the airflow showed good agreement with the experimental data. Detailed analyses of the response of the probe under various flow, thermodynamic, and cloud conditions, are provided in the paper.

ice crystal↗

Orion Capsule Parachute Assembly System (CPAS) Overload Testing Approach and Results

The qualification of the Orion Capsule Parachute Assembly System (CPAS) system includes exposure to loads and dynamic pressures above the required values as validation of the parachutes' structural integrity. As outlined in the certification plan, each of the four parachutes of the system are to be subjected to 110% of their respective maximum dynamic pressure requirements. The Main and Drogue parachutes have satisfied this overload condition in drop testing and due to cost and schedule constraints, the Forward Bay Cover Parachute (FBCP) and Pilot parachute were subjected to the overload condition in the ground testing described in this document. The test objectives and pass/fail criteria were established and require the parachutes to achieve and maintain a target riser load (associated with a minimum of 110% dynamic pressure overload) for a minimum of three seconds while sustaining no failures of any structural members (vent hoop, radials, suspension line) or any damage which propagates into catastrophic failure of the canopy. Considering the assumptions and limitations associated with the ground testing (primarily non-uniform flow field of the ground test system and variations in parachute manufacturing), a method of establishing the desired overload condition was determined by the technical community and covers the 2-sigma bounds of the drag area distribution derived from drop testing. On June 27, 2017 the testing was executed at the High Velocity Airflow System (HiVAS) facility located at the Weapon Survivability Laboratory (WSL) at the Naval Air Warfare Center, Weapons Division (NAWCWD) China Lake. Engineering Development Unit (EDU) parachutes were used as pathfinders to gain experience with achieving the test conditions. Additional runs were executed to measure the airflow at the same location as the canopy skirt, although this data is not required to satisfy the test objectives and parachute pass/fail criteria. The qualification parachutes were successfully exposed to the target conditions and sustained only minor damage.

Daum, Jared S.↗

High Speed Inlet Distortion Test for the X 59 Low Boom Flight Demonstrator in the NASA Glenn 8-by 6-Foot Supersonic Wind Tunnel

The Low Boom Flight Demonstrator (LBFD) High Speed Inlet Distortion Test (HSIDT) was completed in the NASA Glenn Research Center 8- by 6-Foot Supersonic Wind Tunnel (8x6 SWT) using a 9.5 percent-scale propulsion model of the X–59 to evaluate the compatibility and operability of the inlet and engine integration, focusing on the inlet dynamic effects at the engine face. The model was instrumented with steady-state and high-response total pressure probes in the conventional 40-point, equal-area array at the aerodynamic interface plane (AIP). The HSIDT successfully collected high response distortion data points for the X–59 from Mach = 0 to 1.55 for a wide range of angle-of-attack, angle-of-sideslip, and inlet flow. Analyses showed that inlet dynamic distortion and inlet planar wave (or inlet buzz) were within engine limits through most of the flight envelope. The test data showed that inlet planar wave was present at Mach 1.35 and above, at airflows between idle and maximum engine airflow. Engine throttle back will need to be limited when decelerating from supersonic flight Mach to avoid these regions of inlet planar wave. The HSIDT data was also used to compare the metric SUM40, computed from the 40 high-response AIP total pressure probes, with the metric SUM4, computed from four high-response inlet static pressure probes. The data showed that SUM4 can be used as a surrogate for SUM40 during the X–59 flight test to detect inlet planar wave.

X-59↗

Big Data Challenges at CCMC

Like other research centers, the Community Coordinated Modeling Center (CCMC, https://ccmc.gsfc.nasa.gov) at NASA Goddard Space Flight Center (GSFC) is also experiencing the big data challenges. CCMC hosts over 80 space weather models for Runs On Request (ROR), Continuous Runs and Instant Runs simulation services for the research community. In addition, CCMC has started to support simulation output onboarding in response to the Open Science initiative. Overall, we have accumulated over petabytes of simulation output data and are rapidly growing. In this presentation, we will discuss our data and storage challenges. We will present our attempts to address our challenges and any associated lessons learned. CCMC uses Apache Airflow to ensure data transfer is consistent. We will give a brief overview on how we leverage Apache Airflow to enhance our environment.

space weather↗

Big Data Challenges at the Community Coordinated Modeling Center (CCMC)

Like other research centers, the Community Coordinated Modeling Center (CCMC, https://ccmc.gsfc.nasa.gov) at NASA Goddard Space Flight Center (GSFC) is also experiencing the big data challenges. CCMC hosts over 80 space weather models for Runs On Request (ROR), Continuous Runs and Instant Runs simulation services for the research community. In addition, CCMC has started to support simulation output onboarding in response to the Open Science initiative. Overall, we have accumulated over petabytes of simulation output data and are rapidly growing. In this presentation, we will discuss our data and storage challenges. We will present our attempts to address our challenges and any associated lessons learned. CCMC uses Apache Airflow to ensure data transfer is consistent. We will give a brief overview on how we leverage Apache Airflow to enhance our environment.

space weather↗

Advanced Zonal Infiltration Measurement Method for Multifamily Buildings: A Novel Test Procedure to Determine Air Leakage Through External and Internal Surfaces

Measuring air infiltration through the external building envelope as well as between adjacent zones within a building is important since air leakage is related to increased energy use and poor indoor air quality (IAQ). State of the art methods can determine both leakages, however it can be both time consuming and labor intensive as it requires running both guarded and compartmentalization tests. This paper presents our work on developing a simplified testing procedure to determine power law flow equation leakage parameters of both external and internal boundaries of tested zones. The proposed Zonal Multipoint Pressure Test (ZMPT) method modulates airflow in the zone using a variable airflow measurement panel (mounted in either a window or the door), and solving the mass balance equations for the leakage parameters. ZMPT results were compared to conventional test results and found to correlate to within +/-7%.

Jayarathne, Tharanga↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Review of Variable Geometry Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant heat exchangers (HXs) are fundamental components to HVAC&R systems and as a result there is an ever-increasing need for performance and packaging improvements. Typically, HX’s are designed in uniform arrangements with the goal of providing the necessary heat transfer for minimal material costs. Recent research on fin tube heat exchangers (FTHX) with variation in one or more key parameters has shown significant potential for increasing heat transfer, reducing pressure losses, and making HXs more resilient to environmental externalities like airflow maldistribution and frost accumulation. In particular, researchers have increased heat transfer by 7.6% and j/f by 16% via non-uniform tube and winglet shapes. Additionally, multiple cases have shown that variable geometry heat exchangers (VGHX) are able to match the performance of conventional HXs with reductions in material mass and envelope volume of up to 33% and 40%, respectively. This paper presents a literature review of VGHXs specifically with regards to non-uniform FTHX’s.

42 ENGINEERING↗