Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Investigation of In Situ and Ex Situ Passivation of Pyrophoric Uranium–Niobium Alloy Powder

This work evaluates the effectiveness of in situ and ex situ passivation methods for mitigating the pyrophoricity of uranium–6 wt.% niobium spherical powders produced via the hydride–dehydride process coupled with plasma spheroidization. Oxide layer thickness was characterized using STEM/EDX, and pyrophoricity was assessed by a UN-recommended test method, which involves directly dropping the powders in the air. In situ passivation, performed by introducing flowing oxygen during spheroidization, produced oxide layers ranging from tens to hundreds of nanometers but resulted in inconsistent pyrophoricity mitigation at lower oxygen flow rates. Ex situ passivation, achieved by slow oxygen exposure over several months, formed uniform oxide layers of approximately 20 nm and consistently mitigated pyrophoricity. Despite requiring higher bulk oxygen content, in situ passivation enables faster processing and control of oxygen, while ex situ passivation achieves superior oxide uniformity with lower oxygen incorporation. These findings highlight the trade-offs between passivation methods and provide a foundation for improving the safety and scalability of reactive metal powder production.

U-6Nb↗

Computational Fluid Dynamics Simulations of Glass Vitrification Refractory Coupon Tests

The Waste Treatment and Immobilization Plant (WTP) at the Hanford site is nearing the start of the Direct-Feed Low-Activity Waste (DFLAW) operations. DFLAW is destined to convert a pretreated low activity waste portion of the 56 million gallons of tank waste into a stable solid glass. In the subsequent decade completion of the high-level waste (HLW) facility is anticipated. Sustained operational missions of both LAW and HLW melter facilities are expected over multiple decades. In high-temperature glass melters, the refractory lining corrodes over time, which could potentially be an issue for longer term operations, this refractory corrosion is higher at the level of the glass-air interface due to surface tension driven flow. The glass viscosity, melt pool temperature, and glass chemical composition can impact the rate at which the refractory corrodes. This rate is important to quantify for the various waste glasses to be produced at the WTP since the integrity of the refractory should not be a limiting factor affecting the lifetime of the melter. To this end, a series of glasses representative of the first batches of waste glass produced by the WTP will be melted in small-scale crucibles with Monofrax® K-3 coupons inserted. The corrosion of the K-3 will be measured in the melt and at the meltline (or neckline). A model for the corrosion rate will be constructed and implemented into a previously developed framework for a computational fluid dynamics (CFD) model of the full-scale WTP. To assist with experimental design and validate the implementation of the model in the full-scale melter, CFD simulations of the small-scale crucible tests were performed. The bubbling that occurs in the small-scale crucible is initially validated here with a model that uses silicone oil at room temperature. The viscosity of the oil ranges from 1 to 100 Pa•s, which corresponds to operating glass pool temperatures near 1150 °C down to idling temperatures near 950 °C. The simulation results show good agreement with the bubble sizes that form during experiments. CFD modeling of the crucible setup was used to determine bubbling characteristics to match the range of near-wall velocities expected in the full-scale WTP. This study presents the initial CFD modeling results, corrosion testing plan, and some preliminary corrosion samples with an outline for the next steps for the development of the corrosion model.

Abboud, Alexander W. [Idaho National Lab]↗

Reference document for LANL stack sampling and ANSI N13.1 (Article) Gielow RL and McNamee MR 1993. Numerical Flue Gas Flow Modeling for Continuous Emissions Monitoring Applications. EPRI CEM Users Group Meeting. Baltimore. RP1961-13

American National Standard N13.1 “sets forth guidelines and performance criteria for sampling the emissions of airborne radioactive substances in the air discharge ducts and stacks of nuclear facilities. Emphasis is on extractive sampling from a location in a stack or duct where the contaminant is well mixed. At such a location, sampling may be conducted at a single point. This standard provides performance-based criteria for the use of air sampling probes, transport lines, sample collectors, sample monitoring instruments, and gas flow measuring methods. This standard also covers sampling program objectives, quality assurance issues, developing air sampling action levels, system optimization, and system performance verification. Workplace, containment, and environmental air monitoring are not addressed. Specific sample analysis methods and the reporting or interpreting of results are also not addressed.” (HPS 2011).

61 RADIATION PROTECTION AND DOSIMETRY↗

Hydroxide Exchange Membrane Carbon Capture (HEMCC) Using Nickel Hydroxide Batteries and Flow-through Membranes

Proposed is an electrochemical nickel hydroxide based hydroxide exchange membrane carbon capture (HEMCC) device for Direct Air Capture (DAC) of CO2. DAC has been identified as one of the key net negative carbon technologies to achieve net zero carbon emissions. Net negative carbon technologies are required to offset continued emissions from dilute CO2 sources such as agriculture and construction. The majority of current DAC technologies at scale (>1 KT∙yr-1) are adsorbent based technologies with significant energy cost. The traditional DAC energy cost is primarily driven by the temperature swing required to regenerate the sorbent and has been shown to be 1.8 MWh·ton-1 at the system level. Electrochemical pH swing devices are a growing research area for carbon capture devices with the goal of lowering the energy cost required for DAC. A pH gradient is built by generating OH- at the cathode and consuming OH- at the anode. An acid-base equilibrium with CO2 allows for the capture of CO2 at the cathode and release at the anode. This extends from other electrochemical CO2 capture devices based on pKa shifts of an electrochemically active organic species allowing for the capture and release of CO2. Electrochemical CO2 capture is considered promising based on potentially low energy costs to capture CO2 in comparison with current temperature swing adsorption technologies. This work explores Ni(OH)2 electrodes to produce the pH gradient for CO2 capture and release. At the cathode NiOOH is reduced to Ni(OH)2 while at the anode Ni(OH)2 is oxidized to NiOOH. The symmetrical electrodes allow for a low voltage requirement; the thermodynamic potential difference of standard electrochemical reactions is zero. Most of the voltage observed is to produce the pH gradient with the remainder driving the polarization of the electrodes. There is a resistance component as well, but this is small in comparison due to the low current densities used in the device, nominally 2 mA·cm-1. Two similar devices are presented, a traditional MEA (membrane electrode assembly) and a flow-through MEA. The traditional MEA separates the two Ni(OH)2 electrodes with an 80μm Piperion® membrane. While the flow-through membrane separates the electrodes with a three piece membrane consisting of two 80μm Piperion® membranes with a porous membrane between them. In the traditional MEA system air is passed over the cathode for capture, while the flow-through MEA the air is passed through the porous membrane isolated from the electrodes. The traditional MEA has been used to establish a baseline performance of the device and has been shown to capture CO2 at an energy cost of 1 MWh·ton-1 at the device level. An understanding has been built around the components of that energy cost including the relationship of flux to current density, effect of a regeneration process, transient battery behavior, and gas losses coinciding with changing the polarization of the batteries. The flow-through MEA looks to address of transient battery behavior and gas losses. It allows for denser, higher capacity electrodes, which can lean on traditional Ni-MH battery technology used in alkaline batteries used today. The higher capacities, limit the transient battery effect on flux in the device. Gas losses are addressed by having a continuous inlet air stream to the device and continuous outlet product.

Buchen, James↗

Energy Storage Technologies and U.S. Department of War Requirements

This report offers an overarching primer the energy storage market and assessment of each technology’s suitability for U.S. Department of War applications. We find that battery energy storage is the most promising technology for energy storage applications in terms of energy density and cost. While commercial and advanced Li-ion can satisfy certain electric mobility (e.g., cars, midsized vehicles) and electric flight application (e.g. drones) needs of DoW, next generation technologies like Li metal solid-state batteries, and conversion chemistries (Li-air, Li-CFx) are needed for heavy duty applications like armored vehicles, tanks, airplanes, jets. Batteries should also be supplemented with technologies such as supercapacitors and next-generation flywheels to provide short bursts of high energy for high power needs. Thermal energy storage solutions (sensible and latent heat) and fuel cells (PEMFC and SOFC) are good alternatives for supporting energy storage applications in terms of energy density and cost. Gravity-based energy storage promises the least energy density with high cost and should only be used for niche DoW applications. Of the different gravity energy storage technologies reviewed, pumped-hydro, flywheel, and compressed air energy storage are promising, while solid gravity energy storage appears the least attractive. Military facilities requiring 14 days of energy storage can benefit from flow batteries, especially commercial VFRBs and next generation iron-air systems. While VFRBs are expensive, iron-air batteries have the coupled benefits of low cost and good energy density promising 100+ hours of storage.

25 ENERGY STORAGE↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Benchmark Simulation of the Natural Convection Shutdown Heat Removal Test Facility Using SAM

Natural convection systems are a promising method to passively remove heat from reactor cavities during loss of forced flow accident scenarios. In this work at Argonne National Laboratory (ANL), a highly instrumented Natural Convection Shutdown Heat Removal Test Facility (NSTF) was used to demonstrate the effectiveness of air-cooled natural convection systems. In previous work, RELAP5-3D simulations were performed on this facility with favorable comparisons to experiment for mass flow rate, pressure drop, air temperature increase, and air velocity. Both experimental and simulation efforts with this facility present a useful opportunity to perform a benchmark study with the System Analysis Module (SAM). SAM is an advanced thermal-hydraulic system code currently in development at ANL for advanced non-light water reactor safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Thermal chains and entrainment in cumulus updrafts, Part 1: Theoretical description

Recent studies have shown that cumulus updrafts often consist of a succession of discrete rising thermals with spherical vortex-like circulations. Herein, a theory is developed for why this “thermal chain” structure occurs. Theoretical expressions are obtained for a passive tracer, buoyancy, and vertical velocity in axisymmetric moist updrafts. Analysis of these expressions suggests that the thermal chain structure arises from enhanced lateral mixing associated with intrusions of dry environmental air below an updraft’s vertical velocity maximum. This dry air entrainment reduces buoyancy locally. Consequently, the updraft flow above levels of locally reduced buoyancy separates from below, leading to a breakdown of the updraft into successive discrete thermals. The range of conditions in which thermal chains exist is also analyzed from the theoretical expressions. A transition in updraft structure from isolated rising thermal, to thermal chain, to starting plume occurs with increases in updraft width, environmental relative humidity, and/or convective available potential energy. Corresponding expressions for the bulk fractional entrainment rate ε are also obtained. These expressions indicate rather complicated entrainment behavior of ascending updrafts, with local enhancement of ε up to a factor of ~2 associated with the aforementioned environmental air intrusions, consistent with recent large eddy simulation (LES) studies. These locally large entrainment rates contribute significantly to overall updraft dilution in thermal chain-like updrafts, while other regions within the updraft can remain relatively undilute. Part 2 of this study compares results from the theoretical expressions to idealized numerical simulations and LES.

54 ENVIRONMENTAL SCIENCES↗

Flow Development in Radial Plane of Rotating Detonation Engine Integrated with Aerospike

In this study, axial and radial velocity components are measured downstream of a rotating detonation engine (RDE) integrated with an aerospike by using particle image velocimetry (PIV) at 100 kHz. The RDE is operated at high pressures obtained by restricting the RDE exit with a converging nozzle, which also directs the flow radially toward the aerospike. Reactants, methane fuel, and enriched air (67% oxygen and 33% nitrogen) are supplied from separate plenums at ambient temperature. PIV data are presented to investigate how pressure ratios within the RDE channel affect the flow evolution across the aerospike. The RDE is shown to operate stably and consistently in a single wave mode for all six test runs. The study highlights large temporal and spatial variations in both axial and radial flow velocities at the nozzle throat that persist downstream across the aerospike. Each point in the flowfield oscillates at the frequency recorded inside the RDE channel. Overall, the temporally and spatially varying aerospike flowfield is far from the ideal case of a uniform flow at its exit, and it points toward the need to condition the flow within the RDE channel to produce more uniform conditions at the nozzle throat.

Engineering↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Rapidly ramp cryogenic air separation unit without loss of O2 product purity—application for low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for low-carbon, fossil-fuel power plant capable of rapid ramping. Therefore, a cryogenic air separation unit (ASU) as part of low-carbon, fossil-fuel power plant should be capable of rapid ramping. However, highly integrated and nonlinear processes of the ASU would significantly restrict this rapid ramping. To overcome this fundamental issue, we study the basic dynamic process of a state-of-the-art double-column ASU. A flow-driven dynamic model was established in Aspen Plus Dynamics, assuming perfect flow controls, to capture the basic dynamics of ramping ASU. We find the vapor-liquid counter-current flow structure in the low-pressure column is critical to the air separation when rapidly ramping the ASU. This flow structure is established based on a complicated heat integration process. It is simplified as an apparent counter-current heat transfer process in this work, which greatly reduces the complexity for studying the dynamics of ASU. For keeping this basic flow structure, the heat integration is maintained as its heat duty follows the ASU load, through several basic feed-forward and feed-back controllers on the critical stream flowrates. Moreover, we find a fundamental issue of mismatched dynamics in the low-pressure column, resulting in a significant loss of O2 product purity when rapidly ramping down the ASU and an obvious fluctuation of O2 product purity. Based on these explorations, we propose a basic control method for rapidly ramping the ASU without loss of O2 product purity. Results show the ASU basic dynamic process successfully ramps at a rate up to 10%/min (40-100% load) while maintaining the O2 product purity within 95.2-95.6 mol%.

Cheng, Mao↗

Adhesion-force micro-scale study of desiccating granular material

Experiments on five-, four-, three- and two-wet-hydrophilic-grain clusters were performed to investigate evolution of adhesion of granular media during drying on the micro-scale. The experiments show that the adhesion-force of a cluster initially grows at most to three times the original value before decreasing to zero by the end of evaporation. The adhesion-force is composed of capillary pressure force acting over the liquid/solid contact surface area, and surface tension forces acting over the three-phase contact perimeter length. This is in contrast with most macro-scale phenomenological models, in which the only desaturation process variables affecting strength are suction and saturation. Both the contact surface area and contact perimeter length are reduced to zero upon complete liquid evaporation. The morphology of an evaporating water body evolves through slow flow controlled by evaporation rate, interrupted by various modes of fast air entry, which are non-equilibrium jumps of liquid/gas interfaces (Haines jumps). The instabilities involve large adhesion force discontinuities and substantial water mass reconfiguration with water flow in an extremely short time, which makes the process transient. The reconfigurations can reduce the original multi-grain water clusters to four-, three- and two-grain clusters by way of three different instability modes: of thin-sheet instability, or meniscus snap-through instability, depending on the sign of the Gauss curvature of the liquid surface, or finally, for two-grain bridges only, a liquid wire pinch-off. For larger meso-scale assemblies, however, the global adhesion-force evolution is little affected by the jumps. The air entries are potential sites for drying cracks. The (approximately) calculated capillary pressure for two- and three-grain clusters, in no cases is seen to reach high values, predicted from water retention curves.

Engineering↗

MODELING OF ENHANCED AIR DEHUMIDIFICATION THROUGH ELECTRICALLY CHARGED VAPOR CAPTURING ELECTROSTATIC DROPLETS

This paper investigated the potential of a new electrostatic-based water vapor separation system for humidity control in buildings. The Electrospray Vortical Flow eXchanger (EVFX) consists of small electrically charged water droplets released inside air vortexes to attract water vapor molecules, effectively wiping out the humidity from the air. Larger droplets are then removed at the outer wall of the vortex. If a water molecule is placed in a gradient electric field, such a polar molecule experiences a dielectrophoresis force, which moves the molecules and produces a vapor concentration gradient. When the vapor density exceeds the saturation level, nucleation occurs. A thermodynamic model that captures this phenomenon was described in this paper. Electrosprayed droplets were initially charged close to their maximum electrical charge dictated by the Rayleigh limit; these droplets were used as nucleation centers. The high electric charge decreased the pressure of the vapor, which was in equilibrium with the droplets. This enhanced the charged droplets' nucleation and growth that depleted the vapor phase near the droplets, which was compensated for by the dielectrophoresis flow and diffusion. Significant water vapor condensation was predicted for small droplets at a high electrical charge. Beyond a specific droplet size, while the condensation of water vapor was still theoretically possible, it was somewhat limited because the further growth of the large charged droplets was inhibited due to their high inherent water vapor pressure near the surface. A case study illustrated the potentials and limitation of the EVFX for droplets charged to the Rayleigh limit, for which the effective range of diameters resulted between 10 nm up to few micron.

Morcelli, Stefano↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗