Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Improved modeling of the solid-to-plasma transition of polystyrene ablator for laser direct-drive inertial confinement fusion hydrocodes

We report that the target performance of laser direct-drive inertial confinement fusion (ICF) can be limited by the development of hydrodynamic instabilities resulting from the nonhomegeneous laser absorption at the target surface, i.e., the laser imprint on the ablator. To understand and describe the formation of these instabilities, the early ablator evolution during the laser irradiation should be considered. In this work, an improved modeling of the solid-to-plasma transition of a polystyrene ablator for laser direct-drive ICF is proposed. This model is devoted to be implemented in hydrocodes dedicated to ICF which generally assume an initial plasma state. The present approach consists of the two-temperature model coupled to the electron, ion and neutral dynamics including the chemical fragmentation of polystyrene. The solid-to-plasma transition is shown to significantly influence the temporal evolution of both free electron density and temperatures, which can lead to different shock formation and propagation compared with an initial plasma state. The influence of the solid-to-plasma transition on the shock dynamics is evidenced by considering the scaling law of the pressure with respect to the laser intensity. The ablator transition is shown to modify the scaling law exponent compared with an initial plasma state.

36 MATERIALS SCIENCE↗

WE-EF-BRA-12: Magnetic Resonance- Guided High-Intensity Focused Ultrasound for Localized Ablation of Head and Neck Tissue Structures: A Feasibility Study in An Animal Model

Purpose: High-intensity focused ultrasound (HIFU) ablation is feasible in the head and neck [1]. This study aims to expand upon these findings to assess the feasibility of treatment planning and monitoring via magnetic resonance imaging (MRI) guidance using a clinical MR-guided HIFU platform. Methods: Two 31 kg pigs were anaesthetized, shaved, and positioned prone on the HIFU table (Sonalleve, Philips Healthcare, Vantaa, Finland). The necks were acoustically coupled to the integrated transducer using gel pads and degassed water. MR imaging verified acoustic coupling and facilitated target selection in the thyroid and thymus. Targets were thermally ablated with 130–200 W of acoustic power over a period of 16 s at a frequency of 1.2 MHz while being monitored through real-time, multi-planar MR-thermometry. Contrast-enhanced MR imaging was used to assess treatment efficacy. Post-treatment, animals were euthanized and sonicated tissues were harvested for histology assessment. Results: MR-thermometry, post-contrast-imaging, and gross pathology demonstrated that the system was capable of causing localized thermal ablation in both the thyroid and the thymus without damaging the aerodigestive tract. In one animal, superficial bruising was observed in the ultrasound beam path. Otherwise, there were no adverse events. Analysis of the tissue histology found regions of damage consistent with acute thermal injury at the targeted locations. Conclusion: It is feasible to use a clinical MR-guided HIFU platform for extracorporeal ablation of porcine head and neck tissues. MR guidance and thermometry are sufficient to target and monitor treatment in the thyroid region, despite the presence of the inhomogeneous aerodigestive tract. Further study is necessary to assess efficacy and survival using a tumor model, and to examine what modifications should be made to the transducer positioning system and associated patient positioning aids to adapt it for clinical head and neck targets.Reference:[1] Esnault et al. (2011). Thyroid, 21(9), 965– 973. Funding support provided by Philips Healthcare. Ari Partanen is a paid employee of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Laser-Ablation Sampling for Accurate Analysis of Sulfur in Edible Salts

We evaluated the performance of laser ablation analysis techniques such as laser-induced breakdown spectroscopy (LIBS), laser ablation inductively coupled optical emission spectrometry (LA-ICP-OES), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), in comparison with that of ICP-OES using aqueous solutions for the quantification of sulfur (S) in edible salts from different geographical origins. We found that the laser ablation based sampling techniques were not influenced by loss of S, which was observed in ICP-OES with aqueous solutions for a certain salt upon their dissolution in aqueous solutions, originating from the formation of volatile species and precipitates upon their dilution in water. Although detection of S using direct laser sampling with LA-ICP-MS has well-known isobaric and polyatomic interferences, LIBS and LA-ICP-OES showed good accuracy in the detection of S for all salts. LIBS also provided the ability to identify the dominant chemical form in which S is present in salts. Correlation between S and oxygen, observed in LIBS spectra, provided chemical information about the presence of S 2- or SO$^{2-}_4$, which are associated with the origin and quality of edible salts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using double pulse laser ablation in air to enhance the strength of laser-driven shocks

In the process of multi-pulse laser ablation, inter-pulse delay time, Δ t , is known to be an important parameter for maximizing ablation efficiency as well as impulse imparted to the target. In this work, using photon Doppler velocimetry, we show that for single pairs of colinear pulses (1064 nm, 8 ns, ∼ 60 J cm -2 per pulse) in air, the peak free surface velocity of the back surface of an aluminum target (125 µm thick) is increased, by a factor of nearly 3, when Δ t = 10 microseconds, compared with both pulses arriving simultaneously (Δ t = 0). Fast imaging of the ablation process suggests this enhancement is due to rarefaction of the contiguous air in the passage of the leading shock produced by ablation, which then in turn allows a larger fraction of the energy of the second pulse to reach the target surface. This interpretation is strengthened by additional experiments in which the two pulses do not overlap on the target surface, but the shock strength is nevertheless enhanced. Given a fixed energy budget this work suggests a prescription for maximizing laser-driven shock strength by judicious choice of inter-pulse delay.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reduction of ablated surface expansion in pulsed-power-driven experiments using an aerosol dielectric coating (Final Technical Report)

The quality of warm dense matter samples created by magnetic compression can be largely affected by material ablation. When the ablated material carries currents, local instabilities can grow, which can lead to nonuniformities in the final magnetic pressure. Extending the previous work by Peterson et al. [Phys. Rev. Lett. 112, 135002 (2014)], Awe et al. [Phys. Rev. Lett. 116, 065001 (2016)], and Hutchison et al. [Phys. Rev. E 97, 053208 (2018)], the experiments reported here demonstrate that the expansion of the ablated material can be significantly reduced by using a simple aerosol spray technique. Coating the current-carrying surfaces with a 30–60-μm layer of polyurethane reduced the expansion of the ablated material by a factor of 2 and eliminated material ejections from sharp corners. This technique, tested at the Michigan Accelerator for Inductive Z-Pinch Experiments pulsed power facility at the University of Michigan with currents up to 400 kA, could allow the production of homogeneous warm dense matter samples on pulsed-power drivers. Because of the simplicity of this method, this work brings forth an important contribution to pulsed-power-driven experiments designed to study nuclear fusion, material properties, and radiation science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subcellular analysis by laser ablation electrospray ionization mass spectrometry

In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

47 OTHER INSTRUMENTATION↗

Microglial ablation and lipopolysaccharide preconditioning affects pilocarpine-induced seizures in mice

Activated microglia have been associated with neurodegeneration in patients and in animal models of Temporal Lobe Epilepsy (TLE), however their precise functions as neurotoxic or neuroprotective is a topic of significant investigation. To explore this, we examined the effects of pilocarpine-induced seizures in transgenic mice where microglia/macrophages were conditionally ablated. We found that unilateral ablation of microglia from the dorsal hippocampus did not alter acute seizure sensitivity. However, when this procedure was coupled with lipopolysaccharide (LPS) preconditioning (1 mg/kg given 24 h prior to acute seizure), we observed a significant pro-convulsant phenomenon. This effect was associated with lower metabolic activation in the ipsilateral hippocampus during acute seizures, and could be attributed to activity in the mossy fiber pathway. These findings reveal that preconditioning with LPS 24 h prior to seizure induction may have a protective effect which is abolished by unilateral hippocampal microglia/macrophage ablation.

59 BASIC BIOLOGICAL SCIENCES↗

Isotope Ratio Analysis on Micron-Sized Particles in Complex Matrices by Laser Ablation – Absorption Ratio Spectrometry

Laser ablation has been combined with dual tunable diode laser absorption spectrometry to measure 152 Gd: 160 Gd isotope ratios in micron-size particles. The diode lasers are tuned to specific isotopes in two different atomic transitions at 405.9 nm ( 152 Gd) and 413.4 nm ( 160 Gd) and directed collinearly through the laser ablation plume, separated on a diffraction grating, and detected with photodiodes to monitor transient absorption signals on a shot-by-shot basis. The method has been characterized first using Gd metal foil and then with particles of GdCl 3 •xH 2 0 as binary and ternary mixtures with 152Gd:160Gd isotope ratios ranging from 0.01 to 0.43. These particulate mixtures have been diluted with Columbia River sediment powder (SRM 4350B) to simulate environmental samples and we show the method is capable of detecting a few highly enriched particles in the presence of > 100-fold excess of low-enrichment particles, even when the Gd-bearing particles are a minor component (0.08%) in the SRM powder and widely dispersed (1178 particles detected in 800 000 ablation laser shots). The implications for monitoring 235 U: 238 U enrichment ratios, as related to the nuclear industry, are discussed

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Femtosecond laser ablation particle introduction to a liquid sampling-atmospheric pressure glow discharge ionization source

This work describes the use of a compact, liquid sampling – atmospheric pressure glow discharge (LS-APGD) ionization source to ionize metal particles within a laser ablation aerosol. Mass analysis was performed with a Thermo Scientific Exactive Mass Spectrometer which utilizes an orbitrap mass analyzer capable of producing mass resolution exceeding M/ΔM > 160,000. The LS-APGD source generates a low-power plasma between the surface of an electrolytic solution flowing at several µl min-1 through a fused silica capillary and a counter electrode consisting of a stainless steel capillary employed to deliver the laser ablation particles into the plasma. Sample particles of approximately 100 nm were generated with an Applied Spectra femtosecond laser located remotely and transported through 25 meters of polyurethane tubing by means of argon carrier gas. Samples consisted of an oxygen free copper shard, a disk of solder, and a one-cent U.S. coin. Analyte signal onset was readily detectable relative to the background signal produced by the carrier gas alone. The high mass resolution capability of the orbitrap mass spectrometer was demonstrated on the solder sample with resolution exceeding 90,000 for Pb and 160,000 for Cu. In addition, results from a laser ablation depth-profiling experiment of a one cent coin revealed retention of the relative locations of the ~10 µm copper cladding and zinc rich bulk layers.

36 MATERIALS SCIENCE↗

Atomic understanding of structural deformations upon ablation of graphene

We investigate the atomic rearrangement in graphene under femtosecond pulse illumination with reactive molecular dynamics simulations and compare with ultra-fast laser ablation experiments. To model the impact of the laser pulse irradiation, heat is locally applied to a selected area of the graphene layer and the resulting structural deformation is simulated as a function of time, providing a detailed understanding of the bond breaking process under laser illumination and subsequent re-equilibration afterAQ3 the pulse is turned off. Analysis of the atomic dynamics indicates that the types of defects formed depend on the pulse energy and exposure duration. By varying the exposed area, we determine that the shape of the ablated area is not only a function of the pulse energy, but also of the beam spot size and pulse repetition. Furthermore, we apply a machine learning approach to extrapolate our simulated data to experimental length scales and reproduce the trends in ablated area as a function of temperature. Furthermore, our study provides a first step towards understanding the design parameters for graphene nano-patterning.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Combining Transmission Geometry Laser Ablation and a Non Contact Continuous Flow Surface Sampling Probe/Electrospray Emitter for Mass Spectrometry-Based Chemical Imaging

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection into a continuous flow surface sampling probe/electrospray emitter for mass spectrometry based chemical imaging. The flow probe/emitter device was placed in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collected was immediately aspirated into the probe and on to the electrospray emitter, ionized and detected with the mass spectrometer. Freehand drawn ink lines and letters and an inked fingerprint on microscope slides were analyzed. The circular laser ablation area was about 210 m in diameter and under the conditions used in these experiments the spatial resolution, as determined by the size of the surface features distinguished in the chemical images, was about 100 m.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Percutaneous Radiofrequency Ablation of Painful Spinal Tumors Adjacent to the Spinal Cord with Real-Time Monitoring of Spinal Canal Temperature: A Prospective Study

PurposeTo prospectively evaluate the feasibility, safety, and clinical utility of bone radiofrequency (RF) ablation with real-time monitoring of the spinal canal temperature for the treatment of spinal tumors adjacent to the spinal cord.Materials and MethodsOur Institutional Review Board approved this study. Patients gave informed consent. The inclusion criteria were (a) a painful spinal metastasis and (b) a distance of 1 cm or less between the metastasis and the spinal cord. The thermocouple was placed in the spinal canal under CT fluoroscopic guidance. When the spinal canal temperature reached 45{sup o}C, RF application was immediately stopped. RF ablation was considered technically successful when the procedure was performed without major complications. Clinical success was defined as a fall in the visual analogue scale score of at least 2 points.ResultsTen patients with spinal tumors measuring 3-8 cm (mean, 4.9 {+-} 1.5 cm) were enrolled. The distance between the tumor and the spinal cord was 1-6 mm (mean, 2.4 {+-} 1.6 mm). All procedures were judged technically successful (100%). The spinal canal temperature did not exceed 45{sup o}C in 9 of the 10 patients (90%). In the remaining patient, the temperature rose to 48{sup o}C, resulting in transient neural damage, although RF application was immediately stopped when the temperature reached 45{sup o}C. Clinical success was achieved within 1 week in all patients (100%).ConclusionBone RF ablation with real-time monitoring of the spinal canal temperature is feasible, safe, and clinically useful for the treatment of painful spinal metastases adjacent to the spinal cord.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous RF Thermal Ablation of Renal Tumors: Is US Guidance Really Less Favorable Than Other Imaging Guidance Techniques?

The purpose of this study was to compare our experience with ultrasound (US)-guided percutaneous radiofrequency thermal ablation (RFA) of renal tumors with results of CT-guided and MRI-guided series in the current literature. Of 90 consecutive renal tumors treated with RFA in 71 patients, 87 lesions were ablated under US guidance. We performed a retrospective analysis of clinical outcome and safety. Results were then compared to published case series where CT and MRI guidances were used exclusively. In our series we had a major complication rate of 4.6%, whereas in CT- and MRI-based series it was 0-12% (mean, 2.2%) and 0-8.3% (mean, 4.1%), respectively. During follow-up (1-68 months; mean, 24 months) technical effectiveness was 89.7%, while it was between 89.5% and 96% in CT-guided series and between 91.7% and 100% in MRI-guided series. The size of successfully treated lesions (28 mm) was lower than that of partially-ablated lesions (36 mm; p = 0.004) and only central lesion location proved to be a negative prognostic factor (p = 0.009); in CT-guided series, positive prognostic factors were exophytic growth and size {<=}3 cm. 'Tumor-specific' 2-year survival was 92% in our series, 90-96% in CT-guided series, and not reported in MRI-guided series. In conclusion, despite common beliefs, US guidance in RFA of renal tumors is not less favorable than other guidance techniques. Thus the interventional radiologist can choose his or her preferred technique taking into account personal experience and available equipment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Protection During Percutaneous Thermal Ablation Procedures: Interest of Carbon Dioxide Dissection and Temperature Monitoring

Percutaneous image-guided thermal ablation of tumor is widely used, and thermal injury to collateral structures is a known complication of this technique. To avoid thermal damage to surrounding structures, several protection techniques have been reported. We report the use of a simple and effective protective technique combining carbon dioxide dissection and thermocouple: CO{sub 2} displaces the nontarget structures, and its low thermal conductivity provides excellent insulation; insertion of a thermocouple in contact with vulnerable structures achieves continuous thermal monitoring. We performed percutaneous thermal ablation of 37 tumors in 35 patients (4 laser, 10 radiofrequency, and 23 cryoablations) with protection of adjacent vulnerable structures by using CO{sub 2} dissection combined with continuous thermal monitoring with thermocouple. Tumor locations were various (19 intra-abdominal tumors including 4 livers and 9 kidneys, 18 musculoskeletal tumors including 11 spinal tumors). CO{sub 2} volume ranged from 10 ml (epidural space) to 1500 ml (abdominal). Repeated insufflations were performed if necessary, depending on the information given by the thermocouple and imaging control. Dissection with optimal thermal protection was achieved in all cases except two patients where adherences (one postoperative, one arachnoiditis) blocked proper gaseous distribution. No complication referred to this technique was noted. This safe, cost-effective, and simple method increases the safety and the success rate of percutaneous thermal ablation procedures. It also offers the potential to increase the number of tumors that can be treated via a percutaneous approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Ablation of a Mesenteric Cyst Using Ethanol: Is It Feasible?

A huge mesenteric cyst in a 61-year-old female was treated by percutaneous ablation using ethanol. Marked shrinkage was achieved and regrowth was not seen 16 months after ablation. Resection is the standard therapy for mesenteric cysts, but it may be valuable to discuss the feasibility of percutaneous ablation before resection if the lesion wall is smooth and thin, and if solid nodules are not depicted on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Improvement Guidelines for Radiofrequency Ablation of Liver Tumours

The development of image-guided percutaneous techniques for local tumour ablation has been one of the major advances in the treatment of liver malignancies. Among these methods, radiofrequency ablation (RFA) is currently established as the primary ablative modality at most institutions. RFA is accepted as the best therapeutic choice for patients with early-stage hepatocellular carcinoma (HCC) when liver transplantation or surgical resection are not suitable options [1, 2]. In addition, RFA is considered a viable alternate to surgery (1) for inoperable patients with limited hepatic metastatic disease, especially from colorectal cancer, and (2) for patients deemed ineligible for surgical resection because of extent and location of the disease or concurrent medical conditions [3]. These guidelines were written to be used in quality-improvement programs to assess RFA of HCC and liver metastases. The most important processes of care are (1) patient selection, (2) performing the procedure, and (3) monitoring the patient. The outcome measures or indicators for these processes are indications, success rates, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovenous Laser Ablation as a Treatment for Postsurgical Recurrent Saphenous Insufficiency

The purpose of this study was to investigate the safety and efficacy of endovenous laser ablation as a treatment for recurrent symptomatic saphenous insufficiency occurring after saphenous vein ligation and stripping. A single-center retrospective review of patients who received endovenous laser ablation as a treatment for recurrent symptomatic saphenous insufficiency after ligation and stripping between November 2003 and October 2006 was performed. Fifty-six insufficient saphenous systems were identified in 38 patients. Follow-up consisted of a clinical examination in all patients as well as selective lower-extremity duplex ultrasound as clinically indicated. All 38 patients demonstrated complete closure of the insufficient saphenous vein by clinical examination and/or duplex ultrasound evaluation. Preoperative symptoms resolved after treatment in all 38 patients. No major complications were identified. Endovenous laser ablation of recurrent symptomatic saphenous venous insufficiency is a safe and effective treatment in patients who develop recurrent symptoms after saphenous vein ligation and stripping.

62 RADIOLOGY AND NUCLEAR MEDICINE↗