Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “90.1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

SU-E-T-405: Robustness of Volumetric-Modulated Arc Therapy (VMAT) Plans to Systematic MLC Positional Errors

Purpose: To evaluate the dosimetric impact of systematic MLC positional errors (PEs) on the quality of volumetric-modulated arc therapy (VMAT) plans. Methods: Five patients with head-and-neck cancer (HN) and five patients with prostate cancer were randomly chosen for this study. The clinically approved VMAT plans were designed with 2–4 coplanar arc beams with none-zero collimator angles in the Pinnacle planning system. The systematic MLC PEs of 0.5, 1.0, and 2.0 mm on both MLC banks were introduced into the original VMAT plans using an in-house program, and recalculated with the same planned Monitor Units in the Pinnacle system. For each patient, the original VMAT plans and plans with MLC PEs were evaluated according to the dose-volume histogram information and Gamma index analysis. Results: For one primary target, the ratio of V100 in the plans with 0.5, 1.0, and 2.0 mm MLC PEs to those in the clinical plans was 98.8 ± 2.2%, 97.9 ± 2.1%, 90.1 ± 9.0% for HN cases and 99.5 ± 3.2%, 98.9 ± 1.0%, 97.0 ± 2.5% for prostate cases. For all OARs, the relative difference of Dmean in all plans was less than 1.5%. With 2mm/2% criteria for Gamma analysis, the passing rates were 99.0 ± 1.5% for HN cases and 99.7 ± 0.3% for prostate cases between the planar doses from the original plans and the plans with 1.0 mm MLC errors. The corresponding Gamma passing rates dropped to 88.9 ± 5.3% for HN cases and 83.4 ± 3.2% for prostate cases when comparing planar doses from the original plans and the plans with 2.0 mm MLC errors. Conclusion: For VMAT plans, systematic MLC PEs up to 1.0 mm did not affect the plan quality in term of target coverage, OAR sparing, and Gamma analysis with 2mm/2% criteria.

60 APPLIED LIFE SCIENCES↗

Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.

60 APPLIED LIFE SCIENCES↗

pnnl/ruleset-checking-tool

The Ruleset Checking Tool (RCT) will be a tool for verifying implementation of a ruleset (such as ASHRAE Standard 90.1 Appendix G) in building performance modeling (BPM) tools.

McNeill, James↗

pnnl/90.1-PRM_ECB-ReviewManual

The 90.1 Energy Cost Budget and Performance Rating Method Submittal Review Manual (the Manual) is a comprehensive reference for reviewing modeling based energy code compliance submittals.

Xu, Weili [PNNL]↗

OpenStudio®-MCP [SWR-26-035]

OpenStudio®-MCP is a Model Context Protocol (MCP) server that lets AI assistants perform building energy modeling through natural language. Rather than requiring users to learn the OpenStudio® SDK, EnergyPlus® scripting, or Ruby/Python automation, the server translates conversational requests into sequences of tool calls that create models, design HVAC systems, run simulations, and extract results — all within a single chat session. The server's 124 tools are organized into a skills architecture where each skill encapsulates a domain of building energy modeling (envelope, HVAC, loads, weather, simulation, results) behind typed, LLM-friendly interfaces. High-leverage operations like applying ASHRAE 90.1 baseline systems or generating standards-compliant typical buildings are exposed as single tool calls that internally wire dozens of OpenStudio® objects. Bundled measures from ComStock™ and Openstudio® -common-measures-gem are wrapped with dedicated tools and typed arguments rather than exposed through a generic measure interface, so AI models get consistent, error-resistant recipes without needing to discover measure arguments at runtime. A key design decision is structured results extraction: six SQL-based tools return surgical ~300–1,000 token responses (end-use breakdowns, envelope summaries, HVAC sizing, timeseries data) instead of requiring the AI to parse ~100K-token raw HTML reports, making iterative design exploration practical within context window limits. The codebase is designed as a reference implementation — explicit, well-commented, and modular — so that other simulation engines (EnergyPlus® standalone, TRNSYS, DOE-2) can use it as a template for building their own MCP servers.

Ball, Brian [National Laboratory of the Rockies (N↗

Dialogue Between Lighting and HVAC Systems: Improving building system integration

Lighting systems have long been capable of sensing when someone enters or exits a room and using that knowledge to turn lights on or off. More recently, connected lighting systems with sensors integrated into every luminaire have become broadly available, facilitating highly granular occupancy detection. Similarly, HVAC systems have long been able to use an understanding of building occupancy to adjust temperature setpoints and reduce energy use without significant impacts to occupant comfort. Energy codes (e.g., ASHRAE/IES Standard 90.1, IECC, Title 24) now require “occupied standby HVAC control,” whereby systems adjust both temperature and ventilation setpoints in zones that are determined to be unoccupied during normal occupancy hours. Here, this article discusses current issues that stymie the integration of Lighting and HVAC systems, and DOE activities focused on addressing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thinking Like a Whole Building: A Whole Foods Market New Construction Case Study

Whole Foods Market participates in the U.S. Department of Energy's Commercial Building Partnerships (CBP) to identify and develop cost-effective, readily deployed, replicable energy efficiency measures (EEMs) for commercial buildings. Whole Foods Market is working with the National Renewable Energy Laboratory (NREL) on a retrofit and a new construction CBP project. Whole Foods Market's CBP newconstruction project is a standalone store in Raleigh, North Carolina. Whole Foods Market examined the energy systems and the interactions between those systems in the design for the new Raleigh store. Based on this collaboration and preliminary energy modeling, Whole Foods Market and NREL identified a number of cost-effective EEMs that can be readily deployed in other Whole Foods Market storesand in other U.S. supermarkets. If the actual savings in the Raleigh store - which NREL will monitor and verify - match the modeling results, each year this store will save nearly $100,000 in operating costs (Raleigh's rates are about $0.06/kWh for electricity and $0.83/therm for natural gas). The store will also use 41% less energy than a Standard 90.1-compliant store and avoid about 3.7million pounds of carbon dioxide emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thinking Like a Whole Building: Whole Foods Market New Construction Summary, U.S. Department of Energy's Commercial Building Partnerships (Fact Sheet)

Whole Foods Market participates in the U.S. Department of Energy's Commercial Building Partnerships (CBP) to identify and develop cost-effective, readily deployed, replicable energy efficiency measures (EEMs) for commercial buildings. Whole Foods Market is working with the National Renewable Energy Laboratory (NREL) on a retrofit and a new construction CBP project. Whole Foods Market's CBP new construction project is a standalone store in Raleigh, North Carolina. Whole Foods Market examined the energy systems and the interactions between those systems in the design for the new Raleigh store. Based on this collaboration and preliminary energy modeling, Whole Foods Market and NREL identified a number of cost-effective EEMs that can be readily deployed in other Whole Foods Market stores and in other U.S. supermarkets. If the actual savings in the Raleigh store - which NREL will monitor and verify - match the modeling results, each year this store will save nearly $100,000 in operating costs (Raleigh's rates are about $0.06/kWh for electricity and $0.83/therm for natural gas). The store will also use 41% less energy than a Standard 90.1-compliant store and avoid about 3.7 million pounds of carbon dioxide emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Exploratory Energy Analysis of Electrochromic Windows in Small and Medium Office Buildings - Simulated Results Using EnergyPlus

The Department of Energy’s (DOE) Building Technologies Program (BTP) has had an active research program in supporting the development of electrochromic (EC) windows. Electrochromic glazings used in these windows have the capability of varying the transmittance of light and heat in response to an applied voltage. This dynamic property allows these windows to reduce lighting, cooling, and heating energy in buildings where they are employed. The exploratory analysis described in this report examined three different variants of EC glazings, characterized by the amount of visible light and solar heat gain (as measured by the solar heat gain coefficients [SHGC] in their “clear” or transparent states). For these EC glazings, the dynamic range of the SHGC’s between their “dark” (or tinted) state and the clear state were: (0.22 - 0.70, termed “high” SHGC); (0.16 - 0.39, termed “low” SHGC); and (0.13 - 0.19; termed “very low” SHGC). These glazings are compared to conventional (static) glazing that meets the ASHRAE Standard 90.1-2004 energy standard for five different locations in the U.S. All analysis used the EnergyPlus building energy simulation program for modeling EC windows and alternative control strategies. The simulations were conducted for a small and a medium office building, where engineering specifications were taken from the set of Commercial Building Benchmark building models developed by BTP. On the basis of these simulations, total source-level savings in these buildings were estimated to range between 2 to 7%, depending on the amount of window area and building location.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wynkoop Building Performance Measurement: Water

This report is a summary of the water analysis performance for the Denver, Colorado Wynkoop Building. The Wynkoop Building (Figure 1) was built in 2006 as the Environmental Protection Agency (EPA) Region 8 Headquarters intended to house over 900 occupants in the 301,292 gross square feet (248,849 rentable square feet). The building was built on a brownfield in the Lower Downtown Historic District as part of an urban redevelopment effort. The building was designed and constructed through a public-private partnership with the sustainable design elements developed jointly by General Services Administration (GSA) and EPA. That partnership is still active with all parties still engaged to optimize building operations and use the building as a Learning Laboratory. The building design achieved U.S. Green Building Council Leadership in Energy and Environmental Design for New Construction (LEED-NC) Gold Certification in 2008 (Figure 2) and a 2008 EPA Energy Star Rating of 96 with design highlights that include: (1) Water use was designed to use 40% less than a typical design baseline. The design included low flow fixtures, waterless urinals and dual flush toilets; (2) Native and adaptive vegetation were selected to minimize the need for irrigation water for landscaping; and (3) Energy use intensity was modeled at 66.1 kBtus/gross square foot, which is 39% better than ASHRAE 90.1 1999. The Wynkoop Building water use (10 gallons/square foot) was measured at lower than industry average (15 gallons/square foot) and GSA goals (13 gallons/square foot), however, it was higher than building management expected it would be. The type of occupants and number of occupants can have a significant impact on fixture water use. The occupancy per floor varied significantly over the study time period, which added uncertainty to the data analysis. Investigation of the fixture use on the 2nd, 5th, and 7th floors identified potential for water use reduction if the flush direction of the dual-flush toilet handles was reversed. The building management retrofitted the building's toilets with handles that operated on reduced flush when pushed down (0.8 gallons) and full flush when pulled up (1.1 gallons). The water pressure on the 5th floor (< 30 psi) is less than half the pressure on the 7th floor (>80 psi). The measured water savings post-retrofit was lower on the 5th floor than the 7th floor. The differences in water pressure may have had an impact on the quantity of water used per floor. The second floor water use was examined prior to and following the toilet fixture retrofit. This floor is where conference rooms for non-building occupants are available for use, thus occupancy is highly variable. The 3-day average volume per flush event was higher post-retrofit (0.79 gallons per event), in contrast to pre-retrofit (0.57 gallons per event). There were 40% more flush events post retrofit, which impacted the findings. Water use in the third floor fitness center was also measured for a limited number of days. Because of water line accessibility, only water use on the men's side of the fitness center was measured and from that the total fitness center water use was estimated. Using the limited data collected, the fitness center shower water use is approximately 2% of the whole building water use. Overall water use in the Wynkoop Building is below the industry baseline and GSA expectations. The dual flush fixture replacement appears to have resulted in additional water savings that are expected to show a savings in the total annual water use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-Effectiveness Analysis of the 2009 and 2012 IECC Residential Provisions – Technical Support Document

This analysis was conducted by Pacific Northwest National Laboratory (PNNL) in support of the U.S. Department of Energy’s (DOE) Building Energy Codes Program (BECP). DOE supports the development and adoption of efficient residential and commercial building energy codes. These codes set the minimum requirements for energy efficient building design and construction and ensure energy savings on a national level. This analysis focuses on one and two family dwellings, townhomes, and low-rise multifamily residential buildings. For these buildings, the basis of the energy codes is the International Energy Conservation Code (IECC). This report does not address commercial and high-rise residential buildings, which reference ANSI/ASHRAE/IES Standard 90.1.

Mendon, Vrushali V.↗

Technical Support Document: Development of the Advanced Energy Design Guide for Large Hospitals - 50% Energy Savings

This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Large Hospitals: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-LH) ASHRAE et al. (2011b). The AEDG-LH is intended to provide recommendations for achieving 50% whole-building energy savings in large hospitals over levels achieved by following Standard 90.1-2004. The AEDG-LH was created for a 'standard' mid- to large-size hospital, typically at least 100,000 ft2, but the strategies apply to all sizes and classifications of new construction hospital buildings. Its primary focus is new construction, but recommendations may be applicable to facilities undergoing total renovation, and in part to many other hospital renovation, addition, remodeling, and modernization projects (including changes to one or more systems in existing buildings).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation Analyses in Support of DOE’s Fossil Fuel Rule for Single Component Equipment and Lighting Replacements

At the request of the US Department of Energy’s (DOE) Federal Energy Management Program (FEMP), Pacific Northwest National Laboratory (PNNL) conducted a series of building energy simulations using a large office model to investigate the potential savings that could be accrued from a typical chiller, boiler, or lighting replacement in a Federal office building. FEMP’s interest was in knowing whether or not single component replacements like these would have any chance of achieving the fossil- fuel-based energy consumption reduction requirements specified in Section 433 of the Energy Independence and Security Act (EISA) of 20071. Specifically, FEMP was interested in whether an older Federal building, built in the 1980s or 1990s and designed to meet energy standards in place at the time the building was designed, could meet the requirements of Section 433 of EISA for renovations. Many single component renovations like chiller replacements, boiler replacements, and lighting retrofits may meet the minimum cost requirement of Section 433 of EISA but may not offer any opportunity to achieve fossil-fuel-generated energy consumption reductions on the order of 55% or more. If single component renovations such as these would not achieve the necessary reductions, then FEMP would consider modifying rules based on Section 433 of EISA to exempt these types of single component renovations from the overall fossil-fuel-generated energy consumption reduction provisions. FEMP would instead require Federal agencies to ensure that these renovations use FEMP-designated efficiencies for chillers and boilers or the lighting power density requirements found in ASHRAE Standard 90.1-2010. The results of PNNL’s analysis indicated that it is unlikely that a combined boiler and chiller replacement, or an individual boiler or chiller replacement in an older existing Federal building would meet the requirements of Section 433 of EISA. While buildings can achieve up to 34% reduction in cooling and 11% reduction in heating load with this type of retrofit, these savings fall well short of the minimum savings specified in Section 433 of EISA. Similarly, a lighting retrofit in an older existing Federal building would also not likely meet the requirements of Section 433 of EISA. While buildings can save up to 52% on lighting loads, the whole buildings savings would be well short of the minimum savings specified in Section 433 of EISA.

Halverson, Mark A.↗

Kohl's Aims for Energy Savings in Warm-Humid Climates [Fact Sheet]

Kohl's Department Stores partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to build new stores that consume at least 50% less than the requirements set by ASHRAE/ANSI/IESNA Standard 90.1-20041 as part of DOE's Commercial Building Partnership (CBP) program. The National Renewable Energy Laboratory (NREL) provided technical expertise on the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RTU Comparison Calculator Enhancement Plan

Over the past two years, Department of Energy’s Building Technologies Office (BTO) has been investigating ways to increase the operating efficiency of the packaged rooftop units (RTUs) in the field. First, by issuing a challenge to the RTU manufactures to increase the integrated energy efficiency ratio (IEER) by 60% over the existing ASHRAE 90.1-2010 standard. Second, by evaluating the performance of an advanced RTU controller that reduces the energy consumption by over 40%. BTO has previously also funded development of a RTU comparison calculator (RTUCC). RTUCC is a web-based tool that provides the user a way to compare energy and cost savings for two units with different efficiencies. However, the RTUCC currently cannot compare savings associated with either the RTU Challenge unit or the advanced RTU controls retrofit. Therefore, BTO has asked PNNL to enhance the tool so building owners can compare energy and savings associated with this new class of products. This document provides the details of the enhancements that are required to support estimating energy savings from use of RTU challenge units or advanced controls on existing RTUs.

Miller, James D.↗

Iowa Compliance Implementation and Evaluation Guide

This Guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

Cole, Pamala C.↗

Nevada Compliance Implementation and Evaluation Guide

This Guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

Cole, Pamala C.↗

Utah Compliance Implementation and Evaluation Guide

This Guide is designed to assist state and local code jurisdictions in achieving statewide compliance with the 2009 International Energy Conservation Code (IECC) for residential buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 for commercial buildings.

Cole, Pamala C.↗