Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3d”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Performance assessment of 3D printed multi-material energy absorber for automotive bumper: pedestrian lower extremity protection

Designing an energy absorber for automotive bumpers involves balancing low-speed and high-speed impacts to ensure safety, reduce repair costs, and meet regulatory standards. Here, this study explores a novel design using multi-material 3D printing and structural optimization to fabricate a lightweight and cost-efficient energy absorber. The design effectively dissipates energy in low-speed collisions and minimizes force transmission in high-speed pedestrain impacts, helping to meet both safety and performance requirements. The energy absorber design combines 20% carbon fiber-reinforced acrylonitrile butadiene styrene (CF-ABS) and thermoplastic polyurethane (TPU) for optimal stiffness and flexibility. It uses 3D-printed lattice structures optimized through finite element simulations to help meet both low-speed and high-speed impact requirements. Full-scale energy absorbers were 3D-printed using optimized CF-ABS/TPU blends and tested under high-speed impact using the Flexible Pedestrian Legform Impactor (Flex-PLI). For fair comparison, a baseline bumper with a traditional triangular lattice structure, also 3D-printed from the same CF-ABS/TPU materials, was similarly tested. Interestingly, both the optimized and baseline 3D-printed energy absorbers showed nearly identical performance, successfully meeting injury limits. Their performances were also benchmarked against an injection-molded energy absorber. While both 3D-printed and injection-molded designs met injury limits, the 3D-printed absorber exhibited a higher tibia bending moment, indicating an opportunity for further optimization. A Techno-Economic Analysis compared the costs of producing energy absorbers using traditional manufacturing and 3D printing. The analysis highlighted that 3D printing offers cost benefits for low to medium production volumes, with the total cost per energy absorber at ∼ $\$$74, compared to traditional methods that become economical beyond 2000 units.

Additive manufacturing↗

Emulation of radiation transport in 3D stochastic media using 1D planar Monte Carlo stochastic media radiation transport algorithms

A subset of stochastic media radiation transport problems involves those in which radiation is incident on a thin slab of stochastic material. Particle tracking in 3D for such problems is expensive, and 1D planar models lack accuracy because they only allow the material to change in one dimension. Therefore, we propose dimensional emulation, which through a slight modification allows existing 1D planar geometry stochastic media radiation transport models to reproduce results from the equivalent 3D models by allowing the material to change in all three dimensions, reproducing the fidelity of the 3D model for the low computational cost of the 1D planar model. In this work, we apply dimensional emulation to three Monte Carlo stochastic media radiation transport models: Chord Length Sampling (CLS), the Local Realization Preserving method (LRP), and a variant of Conditional Point Sampling (CoPS). For a common Markovian benchmark set, the 3D emulation variants of these algorithms are numerically verified to reproduce the results of the 3D variants within statistics while running 1.3 to 2 times faster in the implementation within Sandia National Laboratories open-source research code PlaybookMC. The 3D emulation variants are also shown to yield a 72%–92% reduction in error for the thin slab problems in comparison to the 1D benchmark. As a result, the 3D emulation variant of CLS and CoPS-1 are shown to reproduce 3D CLS results that were used to approximate results for a 3D spherical inclusion geometry benchmark set.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3D graphene aerogels-supported Ag and Ag@Ag3PO4 heterostructure for the efficient adsorption-photocatalysis capture of different dye pollutants in water

Highlights: • 3D graphene aerogels-supported Ag and Ag@Ag3PO4 heterostructure are synthesized. • The composite is effective in adsorption-photocatalysis cationic and anionic dyes. • The apparent adsorption-photocatalysis removal sequence is NR > RhB > MB > MO. • The contributions of adsorption and photocatalysis is different for different dyes. • The composite exhibits the highest catalytic activities with excellent stability. - Abstract: In this paper, we successfully synthesized 3D graphene aerogels-supported Ag and Ag@Ag{sub 3}PO{sub 4} heterostructure (3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA) by the hetero-growth of Ag{sub 3}PO{sub 4} on partly Ag nanoparticles in macroporous 3D graphene aerogels (3D GA), aiming for the efficient adsorption-photocatalysis capture of both cationic (RhB, MB, and NR) and anionic (MO) dyes from aqueous solutions. For the removal of different dyes, the contributions of adsorption and photocatalysis is different and the apparent removal sequence is NR > RhB > MB > MO on the prepared 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA. Compared with bare Ag{sub 3}PO{sub 4} particles, Ag{sub 3}PO{sub 4}/GO, and Ag/Ag@Ag{sub 3}PO{sub 4}/GO, the prepared 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA exhibits the highest catalytic activities for the visible light degradation of RhB and MO. The possible mechanism for improved photocatalytic degradation of dyes by the 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA is proposed based on the active species trapping experiments. Moreover, the good stability and convenient recycling of the prepared 3D Ag/Ag@Ag{sub 3}PO{sub 4}/GA composite further make it have potential application prospect in eliminating organic contaminants.

36 MATERIALS SCIENCE↗

Dosimetric Comparison Between Intensity-Modulated with Coplanar Field and 3D Conformal Radiotherapy with Noncoplanar Field for Postocular Invasion Tumor

This study presents a dosimetric optimization effort aiming to compare noncoplanar field (NCF) on 3 dimensions conformal radiotherapy (3D-CRT) and coplanar field (CF) on intensity-modulated radiotherapy (IMRT) planning for postocular invasion tumor. We performed a planning study on the computed tomography data of 8 consecutive patients with localized postocular invasion tumor. Four fields NCF 3D-CRT in the transverse plane with gantry angles of 0-10 deg., 30-45 deg., 240-270 deg., and 310-335 deg. degrees were isocentered at the center of gravity of the target volume. The geometry of the beams was determined by beam's eye view. The same constraints were prepared with between CF IMRT optimization and NCF 3D-CRT treatment. The maximum point doses (D max) for the different optic pathway structures (OPS) with NCF 3D-CRT treatment should differ in no more than 3% from those with the NCF IMRT plan. Dose-volume histograms (DVHs) were obtained for all targets and organ at risk (OAR) with both treatment techniques. Plans with NCF 3D-CRT and CF IMRT constraints on target dose in homogeneity were computed, as well as the conformity index (CI) and homogeneity index (HI) in the target volume. The PTV coverage was optimal with both NCF 3D-CRT and CF IMRT plans in the 8 tumor sites. No difference was noted between the two techniques for the average D{sub max} and D{sub min} dose. NCF 3D-CRT and CF IMRT will yield similar results on CI. However, HI was a significant difference between NCF 3D-CRT and CF IMRT plan (p < 0.001). Physical endpoints for target showed the mean target dose to be low in the CF IMRT plan, caused by a large target dose in homogeneity (p < 0.001). The impact of NCF 3D-CRT versus CF IMRT set-up is very slight. NCF3D-CRT is one of the treatment options for postocular invasion tumor. However, constraints for OARs are needed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of 3D conformal, IMRT, and V-MAT techniques for accelerated partial-breast irradiation (APBI)

The purpose is to dosimetrically compare the following 3 delivery techniques: 3-dimensional conformal radiation therapy (3D-CRT), intensity-modulated arc therapy (IMRT), and volumetric-modulated arc therapy (V-MAT) in the treatment of accelerated partial-breast irradiation (APBI). Overall, 16 patients with T1/2N0 breast cancer were treated with 3D-CRT (multiple, noncoplanar photon fields) on the RTOG 0413 partial-breast trial. These cases were subsequently replanned using static gantry IMRT and V-MAT technology to understand dosimetric differences among these 3 techniques. Several dosimetric parameters were used in plan quality evaluation, including dose conformity index (CI) and dose-volume histogram analysis of normal tissue coverage. Quality assurance studies including gamma analysis were performed to compare the measured and calculated dose distributions. The IMRT and V-MAT plans gave more conformal target dose distributions than the 3D-CRT plans (p < 0.05 in CI). The volume of ipsilateral breast receiving 5 and 10 Gy was significantly less using the V-MAT technique than with either 3D-CRT or IMRT (p < 0.05). The maximum lung dose and the ipsilateral lung volume receiving 10 (V{sub 10}) or 20 Gy (V{sub 20}) were significantly less with both V-MAT and IMRT (p < 0.05). The IMRT technique was superior to 3D-CRT and V-MAT of low dose distributions in ipsilateral lung (p < 0.05 in V{sub 5} and D{sub 5}). The total mean monitor units (MUs) for V-MAT (621.0 ± 111.9) were 12.2% less than those for 3D-CRT (707.3 ± 130.9) and 46.5% less than those for IMRT (1161.4 ± 315.6) (p < 0.05). The average machine delivery time was 1.5 ± 0.2 minutes for the V-MAT plans, 7.0 ± 1.6 minutes for the 3D-CRT plans, and 11.5 ± 1.9 minutes for the IMRT plans, demonstrating much less delivery time for V-MAT. Based on this preliminary study, V-MAT and IMRT techniques offer improved dose conformity as compared with 3D-CRT techniques without increasing dose to the ipsilateral lung. In terms of MU and delivery time, V-MAT is significantly more efficient for APBI than for conventional 3D-CRT and static-beam IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Three‐Dimensional Broadband Interferometric Mapping and Polarization (BIMAP‐3D) Observations of Lightning Discharge Processes

Abstract Following on our earlier single‐station, 2‐dimensional (2D) broadband interferometric mapping and polarization (BIMAP) observations of lightning discharges, we recently deployed two BIMAP stations at Los Alamos National Laboratory to map the lightning sources and their polarization in full 3‐dimensional (3D) space (BIMAP‐3D). The two stations are separated by 11.5‐km and each station consists of four antenna sets (instead of three for the original BIMAP) that form a Y ‐shaped array for improved interferometric performance. In this paper, we report the BIMAP‐3D system design, a generalized and analytical 2D interferometry technique for noncoplanar antenna array, a two‐stage 3D mapping technique based on geometric triangulation and baseline‐based differential time of arrival, and a technique to reconstruct the polarization orientation in 3D space by combining the 2D polarization results from the two‐station observations. Along with description of the techniques, we demonstrate and discuss the initial lightning results, including 3D maps for a hybrid intracloud and cloud‐to‐ground flash and for a normal intracloud flash, development of abnormal K‐change leaders, and polarization signatures for a K‐change leader. We find that with the two‐stage 3D mapping techniques, the sources can be located to meters accuracy for a favorable event that occurs between the two stations. We also find the polarization vectors for the example K leader are mostly orthogonal to the leader channel after the full 3D polarization analysis. The main purpose of this paper is to report the BIMAP‐3D techniques and capabilities. Detailed analysis of more specific discharge processes will be reported in later studies.

54 ENVIRONMENTAL SCIENCES↗

Fabrication of a novel 3D-printed perfusion bioreactor for complex cell culture models

We introduce a novel fabrication method for developing a 3D-printed perfusion bioreactor (3D-PBR) to facilitate the in situ growth and differentiation of human bone marrow (BM)-derived mesenchymal stem cells (MSCs) while enabling coculture with vascular cells. To recapitulate human physiology, in vitro platforms must incorporate several key features of their native target organ. This often entails a supportive 3D architecture for growing and differentiating multiple human cell types in situ under perfusion. Other essential characteristics include reproducibility, ease of customization, and biocompatibility. Our 3D-PBR combines these features and was fabricated using a biocompatible resin-based polymer, which was 3D-printed, followed by the addition of a permeable membrane to create a coculture microenvironment. MSCs were encapsulated in a collagen-fibrin gel alongside human endothelium within the 3D-PBR. The physical cues that our 3D-PBR provided facilitated the differentiation of MSCs into specific lineages, such as adipocytes and osteoblasts. Immunohistochemistry images demonstrated that cells grown in the 3D-PBR exhibited more physiologically relevant BM perivascular niche markers compared to static culture models. Our method utilizes emerging 3D printing techniques and alternative materials, departing from traditional PDMS-based soft lithography. These advancements in fabrication further enhance in vitro platforms for diverse cell culture models and vascular permeability assays.

59 BASIC BIOLOGICAL SCIENCES↗

Photoionization of the iodine 3d, 4s, and 4p orbitals in methyl iodide

Ionization of the I 3d, 4s, and 4p orbitals in methyl iodide (CH 3 I) has been studied by using synchrotron radiation to measure the total ion yield and by recording photoelectron spectra with linearly polarized radiation in two polarization orientations. The complete photoelectron spectrum of CH 3 I has been recorded at several photon energies, and bands due to the C 1s, I 3d, 4s, 4p, and 4d atomic-like orbitals, as well as the molecular orbitals, have been observed and assigned. In the vicinity of the I 3d 5/2 and 3d 3/2 ionization thresholds at 626.8 and 638.3 eV, respectively, the ion yield displays weak structure in the pre-edge region due to transitions into valence or Rydberg states, and, at higher energies, a shoulder and a broad maximum attributed to the I 3d 5/2 → εf and the I 3d 3/2 → εf shape resonances, respectively. The absorption spectrum calculated using time-dependent density functional theory, within the Tamm-Dancoff approximation, has allowed assignments to be proposed for the valence and Rydberg states. The Stieltjes imaging technique has been used to simulate the absorption spectrum above the ionization threshold and indicates that transitions into the f(l = 3) continuum channel dominate. This conclusion has been corroborated by a Continuum Multiple Scattering–Xα (CMS–Xα) calculation. The asymmetric broadening of the photoelectron bands associated with the I 3d orbital, due to post collision interaction, is taken into account in our experimental analysis. Experimentally derived photoelectron anisotropy parameters for the I 3d orbital are in good agreement with the theoretical predictions obtained with the CMS–Xα approach. The I 3d shake-up/shake-off photoelectron spectrum has been recorded, and assignments have been proposed for several of the satellites. The M 4 N 45 N 45 and M 5 N 45 N 45 Auger electron yields have been measured, and that for the M 5 N 45 N 45 decay exhibits a maximum due to interchannel coupling between the 3d5/2 and 3d3/2 continua. The photoelectron band associated with the I 4p orbital has an unusual appearance. Based upon previous theoretical work for the analogous Xe 4p orbital, it appears that the initial I 4p -1 hole state decays rapidly through Coster-Kronig and super-Coster-Kronig transitions. This leads to a redistribution of the spectral intensity associated with the I 4p orbital and results in a photoelectron spectrum containing a single structured band together with an extended continuum. Another continuum is observed on the high binding energy side of the peak due to the 4s orbital, and we assign this to super-Coster-Kronig transitions into the 4p -1 4d -1 continuum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of a Hybrid Domain Overlapping Coupling Between SAM and CFD Against the TALL-3D Transients

The System Thermal Hydraulics (STH) code SAM has been coupled to the Computational Fluid Dynamics (CFD) code Simcenter STAR-CCM+ utilizing a hybrid domain overlapping method with an explicit coupling in time. The coupling aims to extend the STH code’s applicability to scenarios where local momentum and energy transfers are important yet difficult for STH codes to capture, such as three-dimensional (3D) mixing. The coupling method’s numerical stability was verified in the past against two closed-loop configurations, and it was validated against a double T-junction experiment with 3D scalar mixing. In the present work, the coupling method is validated against the TALL-3D STH/CFD coupling benchmark facility. TALL-3D is a three-legged, liquid-metal facility with a large, pool-type enclosure (test section) that exhibits 3D flow effects to be modeled by a CFD code. The rest of the system exhibits approximately 1D behavior well-predicted by an STH code. First, the present STAR-CCM+ CFD model of the 3D test section is validated against experimental data. Then, the SAM-STARCCM+ coupled model is validated against six different TALL-3D steady states, including SAM standalone model results for comparison. Lastly, the SAM-STARCCM+ coupled model is validated against two TALL-3D transients, one exhibiting flow reversal in the test section and one exhibiting nonlinear, Limit Cycle Oscillations (LCO). For the first transient, the SAM-STARCCM+ coupled model properly predicts an increase in the test section’s inlet temperature during flow reversal, and this is not predicted by the SAM standalone model. Following flow reversal, the SAM-STARCCM+ coupled model better-predicts the initial flow recovery and following oscillations as the system approaches a final natural circulation state. For the second transient, no true final steady state is observed due to LCO. Neither the SAM-STARCCM+ coupled model nor the SAM standalone model can perfectly capture the experiment’s changing oscillation frequency during the transient. However, the SAM-STARCCM+ coupled model does reproduce the oscillatory feedback observed in the system. This is a significant achievement as the SAM-STARCCM+ coupled model only uses an explicit coupling in time, as opposed to a semi-implicit coupling. In comparison, previous STH/CFD coupling efforts of the TALL-3D facility required semi-implicit coupling to obtain similar results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A 2.5d Yolo-Based Fusion Algorithm for 3d Localization Of Cells

Advances in microscopy techniques such as lattice-light-sheet, confocal, two-photon, and electron microscopy have enabled the visualization of 3D image volumes of tightly packed cells, extracellular structures in tissues, organelles, and subcellular components inside cells. These images sampled by 2D projections are often not accurately interpreted even by human experts. As a use case we focus on 3D image volumes of tightly packed nuclei in brain tissue. Due to out-of-plane excitation and low resolution in the z-axis, non-overlapping cells appear as overlapping 3D volumes and make detecting individual cells challenging. On the other hand, running 3D detection algorithms is computationally expensive and infeasible for large datasets. In addition, most existing 3D algorithms are designed to extract 3D objects by identifying the depth in the 2D images. In this work, we propose a YOLO-based 2.5D fusion algorithm for 3D localization of individual cells in densely packed volumes of nuclei. The proposed method fuses 2D detection of nuclei in sagittal, coronal, and axial planes and predicts six coordinates of the 3D bounding cubes around the detected 3D cells. Promising results were obtained on multiple examples of synthetic dense volumes of nuclei imitating confocal microscopy experimental datasets.

Ziabari, Amir↗

Using flow information to support 3D vessel reconstruction from rotational angiography

For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information can be determined when the angiographic sequence shows inflow and possibly outflow of contrast agent. However, a standard volume reconstruction assumes that the vessel tree is uniformly filled with contrast agent during the whole acquisition. If this is not the case, the reconstruction exhibits artifacts. Here, we show how flow information can be used to support the reconstruction of the 3D vessel centerline and radii in this case. Our method uses the fast marching algorithm to determine the order in which voxels are analyzed. For every voxel, the rotational time intensity curve (R-TIC) is determined from the image intensities at the projection points of the current voxel. Next, the bolus arrival time of the contrast agent at the voxel is estimated from the R-TIC. Then, a measure of the intensity and duration of the enhancement is determined, from which a speed value is calculated that steers the propagation of the fast marching algorithm. The results of the fast marching algorithm are used to determine the 3D centerline by backtracking. The 3D radius is reconstructed from 2D radius estimates on the projection images. The proposed method was tested on computer simulated rotational angiography sequences with systematically varied x-ray acquisition, blood flow, and contrast agent injection parameters and on datasets from an experimental setup using an anthropomorphic cerebrovascular phantom. For the computer simulation, the mean absolute error of the 3D centerline and 3D radius estimation was 0.42 and 0.25 mm, respectively. For the experimental datasets, the mean absolute error of the 3D centerline was 0.45 mm. Under pulsatile and nonpulsatile conditions, flow information can be used to enable a 3D vessel reconstruction from rotational angiography with inflow and possibly outflow of contrast agent. We found that the most important parameter for the quality of the reconstruction of centerline and radii is the range through which the x-ray system rotates in the time span of the injection. Good results were obtained if this range was at least 135 deg. . As a standard c-arm can rotate 205 deg., typically one third of the acquisition can show inflow or outflow of contrast agent, which is required for the quantification of blood flow from rotational angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-231: Comparison of 3D Angiogram and MRI in Delineating the AVM Target for Frameless Stereotactic Radiosurgery

Purpose: Stereotactic radiation therapy (SRT) provides an excellent alternative to embolization and surgical excision for the management of appropriately selected cerebral arteriovenous malformations (AVMs). The currently accepted standard for delineating AVMs is planar digital subtraction angiography (DSA). DSA can be used to acquire a 3D data set that preserves osseous structures (3D-DA) at the time of the angiography for SRT planning. Magnetic resonance imaging (MRI) provides an alternative noninvasive method of visualizing the AVM nidus with comparable spatial resolution. We utilized 3D-DA and T1 post-contrast MRI data to evaluate the differences in SRT target volumes. Methods: Four patients underwent 3D-DA and high-resolution MRI. 3D T1 post-contrast images were obtained in all three reconstruction planes. A planning CT was fused with MRI and 3D-DA data sets. The AVMs were contoured utilizing one of the image sets at a time. Target volume, centroid, and maximum and minimum dimensions were analyzed for each patient. Results: Targets delineated using post-contrast MRI demonstrated a larger mean volume. AVMs >2 cc were found to have a larger difference between MRI and 3D-DA volumes. Larger AVMs also demonstrated a smaller relative uncertainty in contour centroid position (1 mm). AVM targets <2 cc had smaller absolute differences in volume, but larger differences in contour centroid position (2.5 mm). MRI targets demonstrated a more irregular shape compared to 3D-DA targets. Conclusions: Our preliminary data supports the use of MRI alone to delineate AVM targets >2 cc. The greater centroid stability for AVMs >2 cc ensures accurate target localization during image fusion. The larger MRI target volumes did not result in prohibitively greater volumes of normal brain tissue receiving the prescription dose. The larger centroid instability for AVMs <2 cc precludes the use of MRI alone for target delineation. We recommend incorporating a 3D-DA for these patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-77: Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans

Purpose: Patient-specific QA procedures for IMRT and VMAT are traditionally performed by comparing TPS calculations with measured single point values and plane dose distributions by means of gamma analysis. New QA devices permit us to calculate 3D dose distributions on patient anatomy as redundant secondary check and reconstruct it from measurements taken with 2D and 3D detector arrays. 3D dose calculations allow us to perform DVH-based comparisons with clinical relevance, as well as 3D gamma analysis. One of these systems (Compass, IBA Dosimetry) combines traditional 2D with new anatomical-based 3D gamma analysis. This work shows the ability of this system by comparing 2D and 3D gamma analysis in pre-treatment QA for several VMAT prostate plans. Methods: Compass is capable of calculating dose as secondary check from DICOM TPS data and reconstructing it from measurements taken by a 2D ion chamber array (MatriXX Evolution, IBA Dosimetry). Both 2D and 3D gamma tests are available to compare calculated and reconstructed dose in Compass with TPS RT Dose. Results: 15 VMAT prostate plans have been measured with Compass. Dose is reconstructed with Compass for these plans. 2D gamma comparisons can be done for any plane from dose matrix. Mean gamma passing rates for isocenter planes (axial, coronal, sagittal) are (99.7±0.2)%, (99.9±0.1)%, (99.9±0.1)% for reconstructed dose planes. 3D mean gamma passing rates are (98.5±1.7)% for PTVs, (99.1±1.5)% for rectum, (100.0±0.0)% for bladder, (99.6±0.7)% for femoral heads and (98.1±4.1)% for penile bulb. Conclusion: Compass is a powerful tool to perform a complete pre-treatment QA analysis, from 2D techniques to 3D DVH-based techniques with clinical relevance. All reported values for VMAT prostate plans are in good agreement with TPS values. This system permits us to ensure the accuracy in the delivery of VMAT treatments completing a full patient-specific QA program.

60 APPLIED LIFE SCIENCES↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗

SU-F-T-184: 3D Range-Modulator for Scanned Particle Therapy: Development, Monte Carlo Simulations and Measurements

Purpose: Active raster scanning in particle therapy results in highly conformal dose distributions. Treatment time, however, is relatively high due to the large number of different iso-energy layers used. By using only one energy and the so called 3D range-modulator irradiation times of a few seconds only can be achieved, thus making delivery of homogeneous dose to moving targets (e.g. lung cancer) more reliable. Methods: A 3D range-modulator consisting of many pins with base area of 2.25 mm2 and different lengths was developed and manufactured with rapid prototyping technique. The form of the 3D range-modulator was optimised for a spherical target volume with 5 cm diameter placed at 25 cm in a water phantom. Monte Carlo simulations using the FLUKA package were carried out to evaluate the modulating effect of the 3D range-modulator and simulate the resulting dose distribution. The fine and complicated contour form of the 3D range-modulator was taken into account by a specially programmed user routine. Additionally FLUKA was extended with the capability of intensity modulated scanning. To verify the simulation results dose measurements were carried out at the Heidelberg Ion Therapy Center (HIT) with a 400.41 MeV 12C beam. Results: The high resolution measurements show that the 3D range-modulator is capable of producing homogeneous 3D conformal dose distributions, simultaneously reducing significantly irradiation time. Measured dose is in very good agreement with the previously conducted FLUKA simulations, where slight differences were traced back to minor manufacturing deviations from the perfect optimised form. Conclusion: Combined with the advantages of very short treatment time the 3D range-modulator could be an alternative to treat small to medium sized tumours (e.g. lung metastasis) with the same conformity as full raster-scanning treatment. Further simulations and measurements of more complex cases will be conducted to investigate the full potential of the 3D range-modulator.

60 APPLIED LIFE SCIENCES↗

SU-F-T-571: Objective Assessment of 3D Dosimetry for Flattened and Flattened Filter Free Stereotactic Rotational Delivery Using 729-Array Detector with Octavius 4D Phantom

Purpose: The purpose of this study was to assess the potential of 3D dosimetry for flattened and flattened filter free stereotactic rotational delivery in high definition MLC using 729-detector array with Octavius 4D phantom Methods: Twenty rapid arc plans were assessed for this study. For each patient two plans for 6X and 6FFF photon beams were generated with same prescription and critical organ constraints in Eclipse TPS version 13.0 using high definition MLC. Verification plans were generated in scanned Octavius 4D phantom in TPS. 3D dose measurements were collected from 729-ion chamber detector array in Octavius 4D phantom using verisoft software v 6.0. TPS calculated dose was compared with measured 3D dose in verisoft using the following gamma analysis parameters such as 3D volumetric, 3D planar and 2D global gamma in transverse, sagittal and coronal planes for 3mm/3% and 2mm/2% distance to agreement criteria.Passing rate and arithmetic mean of global gamma were analysed for 2D and 3D global gamma in all planes. Results: The average number of dose points passing rate for 2D global gamma with 3mm/3% criteria in transverse, sagittal and coronal planes was 99.06%±2.89%, 98.8%±0.88% and 99.06%±91%, respectively. For 2mm/2% criteria 97.86%±2.26%, 94.49± 2.64% and 94.34%±2.9% was observed. In 3D planar global gamma with 3mm/3% was 99.53%±0.49%, 98.93%±1.03% and 99.29%±1.29%, for 2mm 2% criteria was 97.50%±2.24%, 94.5%±2.5% and 95.38%±4.5%. The maximum arithmetic mean gamma deviation of 0.505%±0.13% was observed in coronal plane for 2D global gamma with 2mm/2% criteria. The 3D volumetric gamma passing rate was observed as 99.61%±0.433% for 3mm /3% and 95.91%±2.51% for 2mm/2%. Conclusion: The objective assessment of 3D dosimetry have demonstrated that the rotational delivery accuracy for flattened and flattened filter free stereotactic plans can be verified by using Octavius system comprising with 729 ion chamber array and Octavius 4D phantom.

60 APPLIED LIFE SCIENCES↗

SU-F-T-580: New Tumor Modeling Using 3D Gel Dosimeter for Brain Stereoctactic Radiotherpy (SRT)

Purpose: The purpose of this study is to develop new tumor model using 3D printing with 3D dosimeter for brain stereoctactic radiotherpy (SRT). Methods: BANG{sup 3} polymer gel was prepared and the gel-filled glass vials were irradiated with a 6 MV photon beam to acquire the calibration curve that present the change of R2 (1/T{sub 2}) value with dose. Graded doses from 0 to 12 Gy with an interval of 2 Gy were delivered. A kit for calibration of gel dosimeter and an 2 tumor model phantoms with a spherical shape were produced using a 3D printer with a polylactic acid after its 3D images were created using Autodesk software. 3D printed tumor phantoms and EBT3 films were irradiated to compare with treatment plan. After irradiation, vials for calibration and tumor model phantoms were scanned at 9.4T MRI. The spin-spin relaxation times (T{sub 2}) according to the each dose were calculated to evaluate the dose response. Acquired images were analyzed using an ImageJ. Scanned MRI images of tumor models were transferred treatment planning system and these were registered to the CT images. In all treatment plans, two arc plans (CW and CCW) were designed to deliver 50 Gy for 10 fractions. For first PTV, treatment plan was accurately designed that 95% of dose to cover 100% of PTV. But 2nd PTV was not intentionally cover 100% of PTV to evaluate the intensity of delivered tumor phantom with polymer gel. We compared the 3D dose distributions obtained from measurements with the 3D printed phantom and calculated with the TPS. Results: 3D printed phantom with a polymer gel was successfully produced. The dose distributions showed qualitatively good agreement among gel, film, and RTP data. Conclusion: A hybrid phantom represents a useful to validate the 3D dose distributions for patient-specific QA.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-01: An Efficient Method of 3D Patient Dose Reconstruction Based On EPID Measurements for Pre-Treatment Patient Specific QA

Purpose: To demonstrate an efficient and clinically relevant patient specific QA method by reconstructing 3D patient dose from 2D EPID images for IMRT plans. Also to determine the usefulness of 2D QA metrics when assessing 3D patient dose deviations. Methods: Using the method developed by King et al (Med Phys 39(5),2839–2847), EPID images of IMRT fields were acquired in air and converted to dose at 10 cm depth (SAD setup) in a flat virtual water phantom. Each EPID measured dose map was then divided by the corresponding treatment planning system (TPS) dose map calculated with an identical setup, to derive a 2D “error matrix”. For each field, the error matrix was used to adjust the doses along the respective ray lines in the original patient 3D dose. All field doses were combined to derive a reconstructed 3D patient dose for quantitative analysis. A software tool was developed to efficiently implement the entire process and was tested with a variety of IMRT plans for 2D (virtual flat phantom) and 3D (in-patient) QA analysis. Results: The method was tested on 60 IMRT plans. The mean (± standard deviation) 2D gamma (2%,2mm) pass rate (2D-GPR) was 97.4±3.0% and the mean 2D gamma index (2D-GI) was 0.35±0.06. The 3D PTV mean dose deviation was 1.8±0.8%. The analysis showed very weak correlations between both the 2D-GPR and 2D-GI when compared with PTV mean dose deviations (R2=0.3561 and 0.3632 respectively). Conclusion: Our method efficiently calculates 3D patient dose from 2D EPID images, utilising all of the advantages of an EPID-based dosimetry system. In this study, the 2D QA metrics did not predict the 3D patient dose deviation. This tool allows reporting of the 3D volumetric dose parameters thus providing more clinically relevant patient specific QA.

60 APPLIED LIFE SCIENCES↗