Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3D image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and template matching and final registration involving C-arm calibration were 36%, 73%, and 93%, respectively, while registration accuracy of 0.59 mm was the best after final registration. By compensating in-plane translation errors by initial template matching, the success rates achieved after the final stage improved consistently for all methods, especially if C-arm calibration was performed simultaneously with the 3D–2D image registration. Conclusions: Because the tested methods perform simultaneous C-arm calibration and 3D–2D registration based solely on anatomical information, they have a high potential for automation and thus for an immediate integration into current interventional workflow. One of the authors’ main contributions is also comprehensive and representative validation performed under realistic conditions as encountered during cerebral EIGI.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation of Augmented Teleoperation of Contact Manipulation Tasks

At Argonne National Laboratory, an enhanced telerobotic concept has been suggested by providing augmented virtual fixtures for precise and dexterous manipulation. The proposed technology incorporated a human-robot interface that can assist personnel on the processes of Deactivation and Decommissioning in sites of high radiation. It has been implemented on a dual-arm robot system, known as Baxter, by integrating the Robotic Operating System (ROS) with 3D sensors and visual-haptic operator interface. However, what remained before its practical utilization is the capability for precisely placing the virtual fixtures. To this end, the objectives involved camera calibration, which required hardware fabrication and setup, as well as modification and implementation of ROS. The goal of this Research and Development is to develop an augmented-reality- based operator interface for human-inclusive, intelligent, and autonomous robotic system for the Deactivation and Decommissioning (D and D) of radioactive sites. The objectives are to develop: Collaborative Robot; Multi-modal Mixed-Reality Human-Robot Interface; Intelligent and Autonomous Behaviors. In order to achieve this, Baxter's Head-Kinect camera and Left-Hand camera need to be calibrated to overlap the real environment with the simulated environment. Camera calibration, which is crucial for precisely placing the virtual fixtures, was successful after running the simulations. The real and simulated environments overlapped, permitting the utilization of augmented teleoperation and the dexterous manipulation of Baxter for D and D applications in nuclear sites. Future steps: Performance evaluation of augmented teleoperation of contact manipulation tasks: Multiple-Camera 3D Reconstruction and Automation. Oculus Interface: Augmented reality and machine learning for enhanced telerobotic operation (Augmented Tele-autonomy): Machine-learning techniques for complex and flexible autonomous robotic behaviors. Interactive remote operation of robotic systems. Mesh cutting with simulation and real robot.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resolving three-dimensional nanoscale heterogeneities in lithium metal batteries with cryoelectron tomography

Current direct observation of sensitive battery materials and interfaces primarily relies on two-dimensional (2D) imaging, leaving out their three-dimensional (3D) relationship. Here, in this study, we used cryoelectron tomography (cryo-ET) to visualize the lithium metal anode in 3D at nanometer resolution and cryoelectron microscopy (cryo-EM) to reveal atomic details in local regions. We imaged both freshly prepared and calendar-aged Li metal anodes to reveal the development of LiH in Li dendrites and the Li-LiH interface, as well as the development of the solid-electrolyte interphase (SEI). Using a convolutional neural network-based technique, the 3D arrangement of Li metal, along with nanoscale LiH and Cu heterogeneities in dendrites, was visualized and annotated. In longer-term calendar aging, we observed more substantial LiH growth accompanied by extended SEI growth. Our results show that the growth of LiH and the extended SEI during battery calendar aging are temporally and spatially separate processes.

LiH↗

Jas4pp — A data-analysis framework for physics and detector studies

This paper describes the Jas4pp framework for exploring physics cases and for detector-performance studies of future particle collision experiments. Jas4pp is a multi-platform Java program for numeric calculations, scientific visualization in 2D and 3D, storing data in various file formats and displaying collision events and detector geometries. It also includes complex data-analysis algorithms for function minimization, regression analysis, event reconstruction (such as jet reconstruction), limit settings and other libraries widely used in particle physics. The framework can be used with several scripting languages, such as Python/Jython, Groovy and JShell. Several benchmark tests discussed in the paper illustrate significant improvements in the performance of the Groovy and JShell scripting languages compared to the standard Python implementation in C. Furthermore, the improvements for numeric computations in Java are attributed to recent enhancements in the Java Virtual Machine.

97 MATHEMATICS AND COMPUTING↗

Poster — Thur Eve — 10: Partial kV CBCT, complete kV CBCT and EPID in breast treatment: a dose comparison study for skin, breasts, heart and lungs

The advantages of kilovoltage cone beam CT (kV CBCT) imaging over electronic portal imaging device (EPID) such as accurate 3D anatomy, soft tissue visualization, fast rigid registration and enhanced precision on patient positioning has lead to its increasing use in clinics. The benefits of this imaging technique are at the cost of increasing the dose to healthy surrounding organs. Our center has moved toward the use of daily partial rotation kV CBCT to restrict the dose to healthy tissues. This study aims to better quantify radiation doses from different image-guidance techniques such as tangential EPID, complete and partial kV CBCT for breast treatments. Cross-calibrated ionization chambers and kV calibrated Gafchromic films were used to measure the dose to the heart, lungs, breasts and skin. It was found that performing partial kV CBCT decreases the heart dose by about 36%, the lungs dose by 31%, the contralateral breast dose by 41% and the ipsilateral breast dose by 43% when compared to a full rotation CBCT. The skin dose measured for a full rotation CBCT was about 0.8 cGy for the contralateral breast and about 0.3 cGy for the ipsilateral breast. The study is still ongoing and results on skin doses for partial rotation kV CBCT as well as for tangential EPID images are upcoming.

60 APPLIED LIFE SCIENCES↗

PNNL-Predictive-Phenomics/ProCaliper

ProCaliper is a Python library that curates, organizes, and computes protein structure features in a way that easily interfaces with user-provided experimental data. It extracts or computes protein binding site, active site, charge, pLDDT (order/disorder), acid dissociation, protonation, solvent accessible surface area, disulfide bond distance, and protein secondary structure data using precomputed protein structures and publicly available databases. It provides a unified API for integrating additional residue-level data and for visualizing residue features in 3D.

Rozum, Jordan [Pacific Northwest National Lab]↗

Ultrasonic Bat Deterrent Technology

The project objective was to advance the development and testing of a near commercial bat-deterrent system with a goal to increase the current GE deterrent system effectiveness to over 50% with broad species applicability. Additionally, the research supported by this program has provided insights into bat behavior and ultrasonic deterrent design that had not previously been explored. Prior research and development had demonstrated the effectiveness of a commercial-grade, air-powered, ultrasonic bat deterrent to be between 30-50% depending upon the species of bat. However, the previous research provided limited insight into the behavioral responses of bats in the presence of ultrasonic deterrent sound fields that could be utilized to improve effectiveness. A unique bat flight room was utilized to observe the behavioral characteristics of bats in the presence of ultrasonic sound fields. Behavioral testing in the bat flight facility demonstrated that ultrasonic sounds similar to those produced by the GE deterrent influenced the activities and behaviors, primarily those associated with foraging, of the species exposed. The study also indicated that continuous and pulsing ultrasonic signals had a similar effect on the bats, and confirmed that as ultrasonic sounds attenuate, their influence on the bats’ activities and behavior decreases. Ground testing at Wolf Ridge Wind, LLC and Shawnee National Forest assessed both continuous and pulsing deterrent signals emitted from the GE deterrent system and further enhanced the behavioral understanding of bats in the presence of the deterrent. With these data and observations, the existing 4-nozzle continuous, or steady, emission ultrasonic system was redesigned to a 6-nozzle system that could emit a pulsing signal covering a larger air space around a turbine. Twelve GE 1.6-100 turbines were outfitted with the deterrent system and a formal three-month field study was performed using daily carcass searches beneath the 12 turbines. Additionally, a unique 3D bat flight path visualization system was utilized to monitor for and identify any changes in bat activity caused by the operation of the deterrent system. Both the carcass search and flight path visualization data indicated that the pulsed deterrent system was effective, but not more effective, than the steady system tested in prior years. However, an unanticipated byproduct of the pulsing system was the emission of intermittent water vapor from the deterrent devices due to the air compression process that powered the devices. This water vapor may have altered the ultrasonic signal and obscured the results in an unknown way. While a qualitative analysis of the effect of the water vapor on the deterrent signal had indicated there was not dramatic change in the expected ultrasonic signal, it was not possible to conclusively determine if the pulse signal would have been more effective in the absence of the water vapor. A mid-season installation of a desiccant system was performed and the dataset divided into two groups to account for the change. Prior to the system change, the deterrent was not effective (-23%, P = 0.8617, α = 0.05) at reducing eastern red bat fatalities and effective (38%, P = 0.0169, α = 0.05) for the non-eastern red bat species, combined. After the installation of the desiccant system, the pulsed deterrent system showed similar results, although not statistically significant, with a point estimates of 23% (P = 0.2924, α = 0.05) observed for eastern red bats and 54% (P = 0.0926, α = 0.05) for the other combined bat species.

17 WIND ENERGY↗

Raptor

Raptor is an efficient Python-based tool for predicting the formation and morphology of stochastic lack of fusion defects in metal AM processes. A major obstacle for the qualification and certification of additively manufactured parts in critical applications continues to be performance variability caused in part by porosity-related defects. High-fidelity process models that could predict these defect features are currently too computationally expensive for component-level analysis. To address this, Raptor employs a high-performance geometric method to model the dynamic melt pool rather than relying on computationally intensive thermal fluid dynamics. This allows Raptor to rapidly identify regions of unmelted material that correspond to lack of fusion pores. The efficiency of this approach significantly reduces the time and resources needed for generating 3D defect predictions, which enables users to conduct large-scale parameter studies and evaluate how process variations affect part quality. The framework offers operational flexibility; users can execute simulations through a simple command line interface or integrate core functions as a library within larger computational workflows. Simulation outputs include 3D porosity maps for visualization and tools for quantitative morphological analysis. These results are suitable for direct comparison with experimental characterization data from methods such as X-ray computed tomography and can be used for statistical process optimization.

Subraveti, Vamsi [Vanderbilt Univ., Nashville, TN ↗

Distributed earth model/orbiter simulation

Distributed Earth Model/Orbiter Simulation (DEMOS) is a network based application developed for the UNIX environment that visually monitors or simulates the Earth and any number of orbiting vehicles. Its purpose is to provide Mission Control Center (MCC) flight controllers with a visually accurate three dimensional (3D) model of the Earth, Sun, Moon and orbiters, driven by real time or simulated data. The project incorporates a graphical user interface, 3D modelling employing state-of-the art hardware, and simulation of orbital mechanics in a networked/distributed environment. The user interface is based on the X Window System and the X Ray toolbox. The 3D modelling utilizes the Programmer's Hierarchical Interactive Graphics System (PHIGS) standard and Raster Technologies hardware for rendering/display performance. The simulation of orbiting vehicles uses two methods of vector propagation implemented with standard UNIX/C for portability. Each part is a distinct process that can run on separate nodes of a network, exploiting each node's unique hardware capabilities. The client/server communication architecture of the application can be reused for a variety of distributed applications.

Geisler, Erik↗

Fusing human and machine skills for remote robotic operations

The question of how computer assists can improve teleoperator trajectory tracking during both free and force-constrained motions is addressed. Computer graphics techniques which enable the human operator to both visualize and predict detailed 3D trajectories in real-time are reported. Man-machine interactive control procedures for better management of manipulator contact forces and positioning are also described. It is found that collectively, these novel advanced teleoperations techniques both enhance system performance and significantly reduce control problems long associated with teleoperations under time delay. Ongoing robotic simulations of the 1984 space shuttle Solar Maximum EVA Repair Mission are briefly described.

Schenker, Paul S.↗

Three-dimensional user interfaces for scientific visualization

The main goal of this project is to develop novel and productive user interface techniques for creating and managing visualizations of computational fluid dynamics (CFD) datasets. We have implemented an application framework in which we can visualize computational fluid dynamics user interfaces. This UI technology allows users to interactively place visualization probes in a dataset and modify some of their parameters. We have also implemented a time-critical scheduling system which strives to maintain a constant frame-rate regardless of the number of visualization techniques. In the past year, we have published parts of this research at two conferences, the research annotation system at Visualization 1994, and the 3D user interface at UIST 1994. The real-time scheduling system has been submitted to SIGGRAPH 1995 conference. Copies of these documents are included with this report.

Vandam, Andries↗

Advecting Procedural Textures for 2D Flow Animation

This paper proposes the use of specially generated 3D procedural textures for visualizing steady state 2D flow fields. We use the flow field to advect and animate the texture over time. However, using standard texture advection techniques and arbitrary textures will introduce some undesirable effects such as: (a) expanding texture from a critical source point, (b) streaking pattern from the boundary of the flowfield, (c) crowding of advected textures near an attracting spiral or sink, and (d) absent or lack of textures in some regions of the flow. This paper proposes a number of strategies to solve these problems. We demonstrate how the technique works using both synthetic data and computational fluid dynamics data.

Kao, David↗

Tomography Analysis of Orion Artemis 1 Heatshield Sample

The Orion spacecraft, under NASA's Artemis program, is an integral step in humanity's ambitions of deep space exploration, including our return to the Moon and subsequent mission to Mars. The performance of Orion's heatshield is central to ensuring the safety and success of such missions. This presentation offers a comprehensive overview of the process used in and findings derived from tomography scans of an Artemis 1 heatshield sample executed at the Lawrence Berkeley National Laboratory's Advanced Light Source. These tomography scans captured high-resolution X-Ray images of the heatshield's microstructure, allowing advanced imaging to be employed for 3D image segmentation and visualization of the sample. The Porous Media Analysis (PuMA) software stands central to our analysis, offering robust computational algorithms and methodologies to digitally compute properties of the heatshield material. The presentation discusses the following derived metrics: - Volume fractions, representing the spatial distribution and amounts of various components throughout the heatshield’s depth. - Porosity and crack distributions, offering insights into the void space within the material, critical for understanding the heatshield's structural integrity. - Fiber orientation, detailing the alignment and arrangement of fibers, significant for material orthotropy. - Permeability estimates, quantifying the passage of gas through the material, relevant for re-entry conditions and pyrolysis gasses. One distinctive feature of this study is the comparative evaluation against data obtained from tomography scans of the Exploration Flight Test-1 (EFT-1) heatshield. Such a comparison offers multiple insights, including evaluation of the consistency and repeatability of manufacturing processes as well as understanding of any evolutionary changes in heatshield design or material properties.

Micro-tomography↗

RCSB Protein Data Bank: visualizing groups of experimentally determined PDB structures alongside computed structure models of proteins

Recent advances in Artificial Intelligence and Machine Learning (e.g., AlphaFold, RosettaFold, and ESMFold) enable prediction of three-dimensional (3D) protein structures from amino acid sequences alone at accuracies comparable to lower-resolution experimental methods. These tools have been employed to predict structures across entire proteomes and the results of large-scale metagenomic sequence studies, yielding an exponential increase in available biomolecular 3D structural information. Given the enormous volume of this newly computed biostructure data, there is an urgent need for robust tools to manage, search, cluster, and visualize large collections of structures. Equally important is the capability to efficiently summarize and visualize metadata, biological/biochemical annotations, and structural features, particularly when working with vast numbers of protein structures of both experimental origin from the Protein Data Bank (PDB) and computationally-predicted models. Moreover, researchers require advanced visualization techniques that support interactive exploration of multiple sequences and structural alignments. This paper introduces a suite of tools provided on the RCSB PDB research-focused web portal RCSB. org, tailor-made for efficient management, search, organization, and visualization of this burgeoning corpus of 3D macromolecular structure data.

3D visualization↗

Launching Liquid Slugs Through Tube Networks: Investigating Multiphase Liquid Slug Acceleration Behaviors in Spacecraft Propulsion Systems using 3D Multiphase VOF CFD Simulations and High-Speed Flow-Visualization Validation Experiments

Propellant management in spacecraft propulsion systems is complex. In many current and future crewed and robotic spacecraft propulsion systems, a number of unintended or unavoidable scenarios can occasionally lead to liquid “slugs” of propellant accumulating in unwanted locations and thereafter being rapidly accelerated through complex and arbitrary tubing networks otherwise filled with vapor or gas. To develop better understanding of the multiphase fluid dynamics associated with these “slug launch” scenarios, NASA Marshal Space Flight Center’s (MSFC) ER42 branch – the propulsion fluid dynamics research branch – conducted 3D multiphase transient Volume of Fluid (VOF) CFD simulations using an in-house tool called LOCI-Stream VOF on semi-canonical tube networks with straight sections, bends, and bend complexes. In addition, high-speed flow visualization validation experiments using propellants were conducted on similar tube network geometries at the NASA White Sands Test Facility (WSTF). These simulations and flow-visualization experiments found these scenarios lead to a variety of unique multiphase fluid dynamic effects involving the leading and trailing edges of the slug in both straight sections and curved bends as well as the progressive erosion, acceleration, and eventual “punch-through” of the driving gas through the liquid slug. Understanding these multiphase fluid dynamic effects has led to unique and often counter-intuitive observations which have been of critical relevance to important engineering concerns associated with these “slug launch” scenarios.

Multiphase Fluid Dynamics↗

Moving beyond the Solvent-Tip Approximation to Determine Site-Specific Variations of Interfacial Water Structure through 3D Force Microscopy

Although interfacial solution structure impacts environmental, biological, and technological phenomena, including colloidal stability, protein assembly, heterogeneous nucleation, and water desalination, its molecular details remain poorly understood. Here, we visualize the three-dimensional (3D) hydration structure at the boehmite(010)-water interface using fast force mapping (FFM). Using a self-consistent scheme to decouple long-range tip-sample interactions from short-range solvation forces, we obtain the solution structure with lattice resolution. The results are benchmarked against molecular dynamics simulations that explicitly include the effects of the tip with different levels of approximation and systematically account for tip size, chemistry, and confinement effects. We find four laterally structured water layers within 1 nm of the surface, with the highest water densities at sites adjacent to hydroxyl groups. The key features beyond the first two layers can only be predicted using a full-scale simulation of the boehmite-water-silica system. Our findings further reveal a complex relationship between site-specific chemistry, water density, and long-range particle interactions; and present important advances toward quantitative data interpretation in 3D FFM.

36 MATERIALS SCIENCE↗

Debris Dispersion Model Using Java 3D

This paper describes web based simulation of Shuttle launch operations and debris dispersion. Java 3D graphics provides geometric and visual content with suitable mathematical model and behaviors of Shuttle launch. Because the model is so heterogeneous and interrelated with various factors, 3D graphics combined with physical models provides mechanisms to understand the complexity of launch and range operations. The main focus in the modeling and simulation covers orbital dynamics and range safety. Range safety areas include destruct limit lines, telemetry and tracking and population risk near range. If there is an explosion of Shuttle during launch, debris dispersion is explained. The shuttle launch and range operations in this paper are discussed based on the operations from Kennedy Space Center, Florida, USA.

Thirumalainambi, Rajkumar↗

How does C-VIEW image quality compare with conventional 2D FFDM?

Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification objects. Spectral analysis of the anthropomorphic phantom showed higher total noise magnitude in the FFDM image compared with C-VIEW. Whereas the FFDM image contained approximately white noise texture, the C-VIEW image exhibited marked noise reduction at midfrequency and high frequency with far less noise suppression at low frequencies resulting in a mottled noise appearance. Conclusions: Their analysis demonstrates many instances where the C-VIEW image quality differs from FFDM. Compared to FFDM, C-VIEW offers a better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-VIEW images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging. Not explicitly explored in this study is how the combination of DBT + C-VIEW performs relative to DBT + FFDM or FFDM alone.

60 APPLIED LIFE SCIENCES↗