Apparatus for preparing medical radioisotopes

Apparatus for radioisotope production includes housing, a plurality of target disks inside the housing and a curved windows positioned convex inward toward the disks. During operation, coolant flows though the housing across the disks and windows while electron beams passes through the window and the disks. The window temperature increases, rising the fastest in the middle of the window where the electron beam hits the window. A flat window would buckle because the center would deform during thermal expansion against the relatively unaffected periphery, but the curved window shape allows the window to endure high thermal and mechanical stress created by a combination of heating from the electron beam(s) and elevated pressure from coolant on the inside of the window. Such a window may be used for applications in which a pressurized coolant acts on only one side of the window.

Woloshun, Keith A.↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska is the state's capital city and has a renewable energy goal to reach 80% renewable energy for the space heating and transportation sectors by 2045. In practical terms, this indicates a need to electrify both sectors, to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Energy Light & Power. In an effort to complement and enable electrification, researchers examined the feasibility to deploy storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows, while preserving operability and views. They can also improve comfort and reduce noise. Researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021, in addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues such as windows that were not square. These results point to several barriers to widespread deployment of storm windows in the area, but also open the door to opportunities to design deployment programs that improve safety as well as efficiency.

cold climate↗

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska, is the state's capital city and aims to reach 80% renewable energy for the space heating and transportation sectors by 2045. This goal highlights a need to electrify both sectors to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Electric Light and Power. To that end, researchers examined the feasibility of deploying storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows while preserving operability and views. They can also improve comfort and reduce noise. In addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews, researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues, such as windows that were not square. These results point to several barriers to the widespread deployment of window upgrades in the area and open the door to opportunities to design deployment programs that improve safety and efficiency.

cold climate↗

A pulsed-power implementation of “Laser Gate” for increasing laser energy coupling and fusion yield in magnetized liner inertial fusion (MagLIF)

Magnetized Liner Inertial Fusion (MagLIF) at Sandia National Laboratories involves a laser preheating stage,where a few-ns laser pulse passes through a few-micron-thick plastic window to preheat gaseous fusion fuel contained within the MagLIF target. Interactions with this window reduce heating e ciency and mix window and target materials into the fuel. A recently proposed idea called \Laser Gate" involves removing the window well before the preheating laser is applied. In this article, we introduce experimental proof-of-principle results for a pulsed-power implementation of Laser Gate, where a thin current-carrying wire weakens the perimeter of the window, allowing the fuel pressure to push the window open and away from the preheating laser path. For this e ort, transparent targets were fabricated and a test facility capable of studying this version of Laser Gate was developed. A 12-frame bright- eld laser schlieren/shadowgraphy imaging system captured the window opening dynamics on microsecond timescales. The images exhibit that the window remains largely intact as it opens and detaches from the target. A column of escaping pressurized gas appears to prevent the detached window from inadvertently moving into the preheating laser path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Case Studies of Residential Façade Upgrades in Four Climate Zones

This paper reports on a project that explored the viability of insulation and window upgrades during siding retrofits in four case studies across the United States. Thousands of homes are re-sided every year, but only a fraction of consumers add insulation and upgrade the windows at the same time, even though a siding replacement is the ideal time to update the thermal performance of building enclosures. To better understand why more siding retrofits do not include insulation and window upgrades, research staff from several organizations collaborated with the U.S. Department of Energy on a multi-faceted research project that included a cost analysis, workforce analysis, market assessment, and contractor assessment. This paper will review four in-field case studies conducted with contractors actively engaged in home re-siding projects that agreed to add rigid insulation and window upgrades as part of their projects. Findings from the case studies will be presented including contractor perspectives, cost, and technical approaches on projects, located in multiple climate zones including Bellingham WA, Jackson MS, Kalamazoo MI, and Phoenix AZ. All projects involved adding continuous rigid insulation on the exterior walls and installation of new cladding. Cladding types varied from wood and metal to fiber cement, vinyl, and traditional stucco. All homes also received a window upgrade, although upgrades varied depending on the original condition of the windows and climate; upgrades included triple-pane windows, low-e storm windows, and exterior shading. Key findings including technical approaches, opportunities, barriers, and project cost will be presented.

re-siding, insulation, rigid insulation, exterior ↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

STITCHES: creating new scenarios of climate model output by stitching together pieces of existing simulations

Abstract. Climate model output emulation has long been attempted to support impact research, mainly to fill in gaps in the scenario space. Given the computational cost of running coupled earth system models (ESMs), which are usually the domain of supercomputers and require on the order of days to weeks to complete a century-long simulation, only a handful of different scenarios are usually chosen to externally force ESM simulations. An effective emulator, able to run on standard computers in times of the order of minutes rather than days could therefore be used to derive climate information under scenarios that were not run by ESMs. Lately, the necessity of accounting for internal variability has also made the availability of initial-condition ensembles, under a specific scenario, important, further increasing the computational demand. At least so far, emulators have been limited to simplified ESM-like output, either seasonal, annual, or decadal averages of basic quantities, like temperature and precipitation, often emulated independently of one another. With this work, we propose a more comprehensive solution to ESM output emulation. Our emulator, STITCHES, uses existing archives of earth system models' (ESMs) scenario experiments to construct ESM-like output under new scenarios or enrich existing initial-condition ensembles, which is what other emulators also aim to do. Importantly, however, STITCHES' output has the same characteristics of the ESM output it sets out to emulate: multivariate, spatially resolved, and high frequency, representing both the forced component and the internal variability around it. STITCHES extends the idea of time sampling – according to which climate outcomes are stratified by the global warming level at which they manifest themselves, irrespective of the scenario and time at which they occur – to the construction of a continuous history of ESM-like output over the whole 21st century, consistent with a 21st-century trajectory of global surface air temperature (GSAT) derived from the scenario that has been chosen as the target of the emulation. STITCHES does so by first splitting the target GSAT trajectory into decade-long windows, then matching each window in turn to a decade-long window within an existing model simulation from the available scenario runs according to its proximity to the target in absolute size of the temperature anomaly and its rate of change. A look-up table is therefore created of a sequence of existing experiment–time-window combinations that, when stitched together, create a GSAT trajectory “similar” to the target. Importantly, we can then stitch together much more than GSAT from these windows, i.e., any output that the ESM has saved for these existing experiment–time-window combinations, at any frequency and spatial scale available in its archive. We show that the stitching does not introduce artifacts in the great majority of cases (we look at temperature and precipitation at monthly frequency and on the native grid of the ESM and at an index of ENSO activity, the Southern Oscillation Index). This is true even if the criteria for the identification of the decades to be stitched together are chosen to work for a smoothed time series of annual GSAT, a result we expect given the larger amount of noise affecting most other variables at finer spatial scales and higher frequencies, which therefore are more “forgiving” of the stitching. We successfully test the method's performance over many ESMs and scenarios. Only a few exceptions surface, but these less-than-optimal outcomes are always associated with a scarcity of the archived simulations from which we can gather the decade-long windows that form the building blocks of the emulated time series. In the great majority of cases, STITCHES' performance is satisfactory according to metrics that reward consistency in trends, interannual and inter-ensemble variance, and autocorrelation structure of the time series stitched together. The method therefore can be used to create ESM-like output according to new scenarios, on the basis of a trajectory of GSAT produced according to that scenario, which could be easily obtained by a simple climate model. It can also be used to increase the size of existing initial-condition ensembles. There are aspects of our emulator that will immediately disqualify it for specific applications, like when climate information is needed whose characteristics result from accumulated quantities over windows of times longer than those used as pieces by STITCHES, droughts longer than a decade for example. But for many applications, we argue that a stitched product can satisfy the climate information needs of impact researchers. STITCHES cannot emulate ESM output from scenarios that result in GSAT trajectories outside of the envelope available in the archive, nor can it emulate trajectories with shapes different from existing ones (overshoots with negative derivative, for example). Therefore, the size and characteristics of the available archives of ESM output are the principal limitations for STITCHES' deployment. Thus, we argue for the possibility of designing scenario experiments within, for example, the next phase of the Coupled Model Intercomparison Project according to new principles, relieved of the need to produce a number of similar trajectories that vary only in radiative forcing strength but more strategically covering the space of temperature anomalies and rates of change.

54 ENVIRONMENTAL SCIENCES↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Micro-structuration effects on local magneto-transport in [Co/Pd]IrMn thin films

We measured the local magneto-transport (MT) signal with an out-of-plane magnetic field, including magneto-resistance (MR) and Extraordinary Hall effect (EHE), in exchange-biased [Co/Pd]IrMn thin multilayers that are micro-structured with a 100 μm window. We found that when measured locally around the window, the MT signal deviate from the expected behavior. We studied possible causes, including film micro-structuration, electrical contact geometry as well as magnetic field angular tilt. We found that tilting the magnetic field direction with respect to the normal direction does not significantly affect the MT signal, whereas the positioning and geometry of the contacts seem to highly affect the MT signal. For comparison purposes, we carried these MT measurements using the Van-der-Pauw method on a set of four microscopic contacts directly surrounding the window, and on another set of micro-contacts located outside the window, as well as a set of four contacts positioned several millimeters away of each other at the corners of the wafer. If the contacts are sufficiently far apart, the EHE and MR signals have the expected shape and are not significantly affected by the presence of the window. If, on the other hand, the contacts are micro-positioned, the shape of the EHE signal is drastically deformed, and may be modeled as a mix of the standard EHE and MR signals measured on the outer contacts. Furthermore, if the micro-contacts are located directly around the window, the deformation is amplified, and the weight of the MR signal in the mix is further increased by about 40 %. This suggests that the electron path in the Hall geometry is disturbed by both the proximity of the electrodes and by the presence of the window, which both contribute to the deformation for about two-third and one third, respectively.

36 MATERIALS SCIENCE↗

Choosing Transport Events for Initiating Splitting and Rouletting

A study was performed to determine which transport events should be used to initiate a weight window lookup to achieve the best variance reduction performance. A weight window lookup potentially triggers particle splitting (in important regions of phase space) or rouletting (in unimportant regions), thereby optimizing computational effort. Potential initiating transport events include collisions (both pre- and post-collision), geometry surface crossings, traversing a mean-free path, and streaming across a weight window boundary. Permutations of these initiating events were tested on an urban model with background radiation sources and a spent fuel cask with a neutron dose mesh tally. Generally, all methods perform better with finer weight window meshes. Tracking on weight windows performs well for coarse weight window meshes, while a combination of splitting each mean-free path, geometric surface crossing, and before collisions performs well for fine weight window meshes.

42 ENGINEERING↗

Method for active sensor signal optimization

A system and method for optimizing a fiber optic sensor by properly clocking or rotationally orienting a window with a fiber optic focuser. This method may include shining light through the focuser into the window and receiving with a reflectometer a first reflection from a first surface of the window and a second reflection from a second surface of the window. Next, the method may include calculating a delta of intensities between the first and second reflections, and then rotating an orientation of the window to a next rotational orientation. The steps of rotating the orientation of the window, receiving reflections, and calculating their delta may be repeated any plurality of times to solve for a plurality of deltas. Then, the method may include the steps of determining which one of the deltas is the largest and fixing the window to the focuser at a rotational orientation associated therewith.

42 ENGINEERING↗

Lasergate: A windowless gas target for enhanced laser preheat in magnetized liner inertial fusion

At the Z Facility at Sandia National Laboratories, the magnetized liner inertial fusion (MagLIF) program aims to study the inertial confinement fusion in deuterium-filled gas cells by implementing a three-step process on the fuel: premagnetization, laser preheat, and Z-pinch compression. In the laser preheat stage, the Z-Beamlet laser focuses through a thin polyimide window to enter the gas cell and heat the fusion fuel. However, it is known that the presence of the few μm thick window reduces the amount of laser energy that enters the gas and causes window material to mix into the fuel. These effects are detrimental to achieving fusion; therefore, a windowless target is desired. The Lasergate concept is designed to accomplish this by “cutting” the window and allowing the interior gas pressure to push the window material out of the beam path just before the heating laser arrives. In this work, we present the proof-of-principle experiments to evaluate a laser-cutting approach to Lasergate and explore the subsequent window and gas dynamics. Further, an experimental comparison of gas preheat with and without Lasergate gives clear indications of an energy deposition advantage using the Lasergate concept, as well as other observed and hypothesized benefits. While Lasergate was conceived with MagLIF in mind, the method is applicable to any laser or diagnostic application requiring direct line of sight to the interior of gas cell targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

High Energy Aqueous Lithium-Ion Batteries (Final Report)

Lithium-ion batteries (LIBs) are a widely used energy storage device. For decades, researchers have been studying aqueous electrolytes due to their non-flammability and environmental friendless. However, the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) of water greatly limit the voltage window of the aqueous electrolyte. The recent concept of ‘solvent-in-salt’ electrolytes, namely ‘water-in-salt’ electrolytes (WISE) for aqueous batteries and ‘super-concentrated’ electrolytes for non-aqueous batteries, greatly expands the electrochemical window of these battery systems and consequently their energy density. This expansion occurs because the large number of salt aggregates in ‘solvent-in-salt’ electrolytes enables preferential salt decomposition over solvent decomposition to form robust interphase layers on electrodes, thus enhancing their stability in a wide range of operating voltages. However, even when the salt concentration reached 63m, regardless of cost, the cathodic potential of the WISE expanded only to 1.75V with an overall electrochemical stability window of <3.25V. To design the next generation of high energy aqueous LIBs, electrolytes that possess a wider electrochemical stability window and lower cost but still maintain the merit of non-flammability are much needed. In this project, we designed the aqueous LIBs with widened voltage window. We reported a cheap and non-flammable ternary eutectic electrolyte that can form a robust solid electrolyte interface (SEI)so that the cathodic limiting potential can be decreased to <1.5 V for Li 4 Ti 5 O 12 anodes, while maintaining both a high ionic conductivity of >10 -3 S cm –1 and a low viscosity. We demonstrated the super-stable2.5V LiMn 2 O 4 ||Li 4 Ti 5 O 12 pouch cell with mass loading of 2.5 mAh/cm. Further, LiCl-LiBr-Graphite/Li full cells were designed with high energy density. Finally, we use a bi-layer design to enlarge the voltage window of aqueous electrolyte, which can endow the stable cycling of aqueous Lithium metal batteries.

25 ENERGY STORAGE↗

Conjugate Heat Transfer Analysis in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 disks. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analysis are performed on the NMR target to analyze the helium flow and volumetric heating through the NMR system. In this iteration of numerical analysis, we update the Mo-100 disk thickness to 0.74 mm and the gap between the Inconel window and the first disk to 0.69 mm. Estimates of the heat flux from the electron beams from Monte Carlo N-Particle code (MCNP) analysis were combined with CFD to perform the CHT analysis. The pressure drop through the targets, force applied on the first disk, beam window and target disk temperatures are some of the quantities estimated using the simulations. The pressure drop through the target was estimated as 0.198 MPa, while the force due to venturi effects across the first disk was estimated to be 100 N. The results show maximum window temperatures over 600 °C and peak disk temperatures over 1600 °C. Past work has shown that beyond 650-700 °C, the Inconel window becomes susceptible to yield and rupture. The increased temperature in these results reduces the margin of error possible on beam spot size. The disk temperatures showed a sinusoidal distribution with the 6 th – 8 th disk from each window exhibiting highest disk temperatures. The peak temperature of the stainless steel housing was close to 316 °C and that of the laminations and spacers was approximately 582 °C.

43 PARTICLE ACCELERATORS↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗