Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-F-207-13: Comparison of Four Dimensional Computed Tomography (4D CT) Versus Breath Hold Images to Determine Pulmonary Nodule Elasticity

Purpose: Elasticity may distinguish malignant from benign pulmonary nodules. To compare determining of malignant pulmonary nodule (MPN) elasticity from four dimensional computed tomography (4D CT) images versus inhale/exhale breath-hold CT images. Methods: We analyzed phase 00 and 50 of 4D CT and deep inhale and natural exhale of breath-hold CT images of 30 MPN treated with stereotactic ablative radiotherapy (SABR). The radius of the smallest MPN was 0.3 cm while the biggest one was 2.1 cm. An intensity based deformable image registration (DIR) workflow was applied to the 4D CT and breath-hold images to determine the volumes of the MPNs and a 1 cm ring of surrounding lung tissue (ring) in each state. Next, an elasticity parameter was derived by calculating the ratio of the volume changes of MPN (exhale:inhale or phase50:phase00) to that of a 1 cm ring of lung tissue surrounding the MPN. The proposed formulation of elasticity enables us to compare volume changes of two different MPN in two different locations of lung. Results: The calculated volume ratio of MPNs from 4D CT (phase50:phase00) and breath-hold images (exhale:inhale) was 1.00±0.23 and 0.95±0.11, respectively. It shows the stiffness of MPN and comparably bigger volume changes of MPN in breath-hold images because of the deeper degree of inhalation. The calculated elasticity of MPNs from 4D CT and breath-hold images was 1.12±0.22 and 1.23±0.26, respectively. For five patients who have had two MPN in their lung, calculated elasticity of tumor A and tumor B follows same trend in both 4D CT and breath-hold images. Conclusion: We showed that 4D CT and breath-hold images are comparable in the ability to calculate the elasticity of MPN. This study has been supported by Department of Defense LCRP 2011 #W81XWH-12-1-0286.

60 APPLIED LIFE SCIENCES↗

MO-DE-210-06: Development of a Supercompounded 3D Volumetric Ultrasound Image Guidance System for Prone Accelerated Partial Breast Irradiation (APBI)

Purpose: For early-stage breast cancer, accelerated partial breast irradiation (APBI) is a cost-effective breast-conserving treatment. Irradiation in a prone position can mitigate respiratory induced breast movement and achieve maximal sparing of heart and lung tissues. However, accurate dose delivery is challenging due to breast deformation and lumpectomy cavity shrinkage. We propose a 3D volumetric ultrasound (US) image guidance system for accurate prone APBI Methods: The designed system, set beneath the prone breast board, consists of a water container, an US scanner, and a two-layer breast immobilization cup. The outer layer of the breast cup forms the inner wall of water container while the inner layer is attached to patient breast directly to immobilization. The US transducer scans is attached to the outer-layer of breast cup at the dent of water container. Rotational US scans in a transverse plane are achieved by simultaneously rotating water container and transducer, and multiple transverse scanning forms a 3D scan. A supercompounding-technique-based volumetric US reconstruction algorithm is developed for 3D image reconstruction. The performance of the designed system is evaluated with two custom-made gelatin phantoms containing several cylindrical inserts filled in with water (11% reflection coefficient between materials). One phantom is designed for positioning evaluation while the other is for scaling assessment. Results: In the positioning evaluation phantom, the central distances between the inserts are 15, 20, 30 and 40 mm. The distances on reconstructed images differ by −0.19, −0.65, −0.11 and −1.67 mm, respectively. In the scaling evaluation phantom, inserts are 12.7, 19.05, 25.40 and 31.75 mm in diameter. Measured inserts’ sizes on images differed by 0.23, 0.19, −0.1 and 0.22 mm, respectively. Conclusion: The phantom evaluation results show that the developed 3D volumetric US system can accurately localize target position and determine target volume, and is a promising image-guidance tool for prone APBI.

60 APPLIED LIFE SCIENCES↗

SU-F-J-167: Use of MR for Permanent Prostate Implant Preplanning

Purpose: To study the feasibility using MR imaging to improve target definition on ultrasound during permanent prostate implants and aid in source strength determination for treatment planning in the OR. Methods: Patients who receive permanent prostate implants undergo MR and CT imaging prior to the implant procedure to determine the volume of the prostate, bony restriction to the procedure, bladder extension, external sphincter length and neurovascular bundle. The volume of the prostate is generally used to order seeds for the procedure. In 10 patients, the MR was used as the preplanning study with the PTV defined as a 2 mm expansion of the MR prostate in all directions except the posterior. Various dose volume parameters for the MR prostate and the PTV were compared to the actual preplan developed and executed in the OR. In addition, there parameters were compared to the post implant dosimetry performed 3 weeks after the implant procedure. Results: The results show that the number of seeds used using MR and US (ultrasound) planning was generally with 2 seeds and the maximum difference was 7 seeds. There is no significant difference between any of the dose index parameters of V100, V150, V200, D99 and D90 parameters between MR planning, US planning and postimplant evaluation There was a significant difference between planned D99 (avg of 105%) and achieved D99 (avg 91%). Conclusion: MR imaging is an invaluable tool to improve target definition for permanent prostate implants. Use of MR images for preplanning improves the confidence with which source can be ordered for the procedure that is OR planned. Ordering a maximum of 10 seeds more than planned would be sufficient to deliver a plan in the OR using US. Moving ahead to non-rigid registration between MR ad US images could further increase the confidence level of MR planning.

60 APPLIED LIFE SCIENCES↗

Elastic properties of crystalline and liquid gallium at high pressures

The elastic properties of gallium, such as the bulk modulus B, the shear modulus G, and the Poisson's ratio {sigma}, are investigated and the relative change in the volume is determined in the stability regions of the Ga I, Ga II, and liquid phases at pressures of up to 1.7 GPa. The observed lines of the Ga I-Ga II phase transition and the melting curves of the Ga I and Ga II phases are in good agreement with the known phase diagram of gallium; in this case, the coordinates of the Ga I-Ga II-melt triple point are determined to be 1.24 {+-} 0.40 GPa and 277 {+-} 2 K. It is shown that the Ga I-Ga II phase transition is accompanied by a considerable decrease in the moduli B (by 30%) and G (by 55%) and an increase in the density by 5.7%. The Poisson's ratio exhibits a jump from typically covalent values of approximately 0.22-0.25 to values of approximately 0.32-0.33, which are characteristic of metals. The observed behavior of the elastic characteristics is described in the framework of the model of the phase transition from a 'quasi-molecular' (partially covalent) metal state to a 'normal' metal state. An increase in the Poisson's ratio in the Ga I phase from 0.22 to 0.25 with an increase in the pressure can be interpreted as a decrease in the degree of covalence, i.e., the degree of spatial anisotropy of the electron density along the bonds, whereas the large value of the pressure derivative of the bulk modulus (equal to approximately 8) observed up to the transition to the Ga II phase or the melt is associated not only with the quasicovalent nature of the Ga I phase but also with the structural features. In view of the presence of seven neighbors for each gallium atom in the Ga I phase, the gallium lattice can be treated as a structure intermediate between typical open-packed and close-packed structures. Premelting effects, such as a flattening of the isothermal dependence of the shear modulus G(p) with increasing pressure and an increase in the slope of the isobaric dependences G(T) with increasing temperature, are revealed in the vicinity of the melting curve. The bulk modulus of liquid gallium near the melting curve proves to be rather close to the corresponding values for the normal metal Ga II.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge and potential of a dust grain versus the intergrain distance and establishment of the latter in a low-pressure plasma

Results from experimental studies of ordered dust structures in plasma are reviewed. The experimental conditions and the data on the grain size and intergrain distance in plasma dust crystals are analyzed. It is shown that intergrain distance is a function of the grain size. The range of the ratio of the dust grain size to the Debye radius within which plasma dust crystals can form is determined. A volume cell surrounding a dust grain in plasma is considered. It is found that the potential and charge of the grain depend substantially on the intergrain distance. The charge, potential, and potential energy of a dust grain in a plasma dust crystal, as well as the electrostatic force exerted by the plasma field on the grain, are calculated by the method of molecular dynamics as functions of the intergrain distance. The corresponding analytic approximations and the criterion for the establishment of a steady-state intergrain distance are proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Regimes of pulsed formation of a compact plasma configuration with a high energy input

Results of experiments on the formation of a compact toroidal magnetic configuration at the Compact Toroid Challenge setup are presented. The experiments were primarily aimed at studying particular formation stages. Two series of experiments, with and without an auxiliary capacitor bank, were conducted. The magnetic field was measured, its time evolution and spatial distribution over the chamber volume were determined, and its influence on the formation regimes was investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade to Ion Exchange Modeling for Removal of Technetium from Hanford Waste Using SuperLig ® 639 Resin

This report documents the development and application of computer models to describe the sorption of pertechnetate [TcO 4 - ], and its surrogate perrhenate [ReO 4 - ], on SuperLig ® 639 resin. Two models have been developed: 1) A thermodynamic isotherm model, based on experimental data, that predicts [TcO 4 - ] and [ReO 4 - ] sorption as a function of solution composition and temperature and 2) A column model that uses the isotherm calculated by the first model to simulate the performance of a full-scale sorption process. The isotherm model provides a synthesis of experimental data collected from many different sources to give a best estimate prediction of the behavior of the pertechnetate-SuperLig ® 639 system and an estimate of the uncertainty in this prediction. The column model provides a prediction of the expected performance of the plant process by determining the volume of waste solution that can be processed based on process design parameters such as column size, flow rate and resin physical properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Upgrade to Ion Exchange Modeling for Removal of Technetium from Hanford Waste Using SuperLig ® 639 Resin

This report documents the development and application of computer models to describe the sorption of pertechnetate [TcO 4 ⁻], and its surrogate perrhenate [ReO 4 ⁻], on SuperLig ® 639 resin. Two models have been developed: 1) A thermodynamic isotherm model, based on experimental data, that predicts [TcO 4 ⁻] and [ReO 4 ⁻] sorption as a function of solution composition and temperature and 2) A column model that uses the isotherm calculated by the first model to simulate the performance of a full-scale sorption process. The isotherm model provides a synthesis of experimental data collected from many different sources to give a best estimate prediction of the behavior of the pertechnetate-SuperLig ® 639 system and an estimate of the uncertainty in this prediction. The column model provides a prediction of the expected performance of the plant process by determining the volume of waste solution that can be processed based on process design parameters such as column size, flow rate and resin physical properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Upgrade to Ion Exchange Modeling for Removal of Technetium from Hanford Waste Using SuperLig ® 639 Resin

This report documents the development and application of computer models to describe the sorption of pertechnetate [TcO 4 ⁻], and its surrogate perrhenate [ReO 4 ⁻], on SuperLig ® 639 resin. Two models have been developed: 1) A thermodynamic isotherm model, based on experimental data, that predicts [TcO 4 ⁻] and [ReO 4 ⁻] sorption as a function of solution composition and temperature and 2) A column model that uses the isotherm calculated by the first model to simulate the performance of a full-scale sorption process. The isotherm model provides a synthesis of experimental data collected from many different sources to give a best estimate prediction of the behavior of the pertechnetate-SuperLig ® 639 system and an estimate of the uncertainty in this prediction. The column model provides a prediction of the expected performance of the plant process by determining the volume of waste solution that can be processed based on process design parameters such as column size, flow rate and resin physical properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deformation mechanisms of nanotwinned Al

The objective of this project is to investigate the role of different types of layer interfaces on the formation of high density stacking fault (SF) in Al in Al/fcc multilayers, and understand the corresponding deformation mechanisms of the films. Stacking faults or twins can be intentionally introduced (via growth) into certain fcc metals with low stacking fault energy (such as Cu, Ag and 330 stainless steels) to achieve high strength, high ductility, superior thermal stability and good electrical conductivity. However it is still a major challenge to synthesize these types of defects into metals with high stacking fault energy, such as Al. Although deformation twins have been observed in some nanocrystalline Al powders by low temperature, high strain rate cryomilling or in Al at the edge of crack tip or indentation (with the assistance of high stress intensity factor), these deformation techniques typically introduce twins sporadically and the control of deformation twin density in Al is still not feasible. This project is designed to test the following hypotheses: (1) Certain type of layer interfaces may assist the formation of SF in Al, (2) Al with high density SF may have deformation mechanisms drastically different from those of coarse-grained Al and nanotwinned Cu. To test these hypotheses, we have performed the following tasks: (i) Investigate the influence of layer interfaces, stresses and deposition parameters on the formation and density of SF in Al. (ii) Understand the role of SF on the deformation behavior of Al. In situ nanoindentation experiments will be performed to probe deformation mechanisms in Al. The major findings related to the formation mechanism of twins and mechanical behavior of nanotwinned metals include the followings: 1) Our studies show that nanotwins can be introduced into metals with high stacking fault energy, in drastic contrast to the general anticipation. 2) We show two strategies that can effectively introduce growth twins in high-stacking-energy metals: use Ag as a template to introduce high density growth twins in epitaxial Al; and the film thickness is important in determination of volume fraction of growth twins. 3) We prove that high density twin boundaries can lead to significant work hardening capability in nanotwinned Al. We have published 13 articles, including Nature Communications, Nano Letters, and two review articles, one in Annual Review of Materials Research; and one in MRS Bulletin. Two postdocs and three graduate students have worked on the project. Two of them have become postdoc at Sandia National Laboratory and Los Alamos National Laboratory. One of the postdoc has become a faculty at a University. One patent has been filed.

36 MATERIALS SCIENCE↗

Assimilating Scanning Radar Data into Cloud-Scale Models

The aim of this project is to improve the initial conditions of large eddy simulations (LES) of deep convective storms by assimilating scanning radar reflectivity and radial velocity data as well as local environmental observations. Accomplishing this goal often results in more accurate numerical forecasts of clouds and precipitation than if the background initial meteorological conditions are solely relied upon for convection initiation and intensification, as is typical of most operational and research models. Conducted in a storm-scale LES framework, these more accurate numerical analyses can serve as tool to better understand and parameterize land-atmosphere coupling, boundary layer turbulence, and cloud processes, each used for model parameterization development of convection. Our work examined the sensitivity of the numerical representation of cloud-scale wind and microphysical structures to: i) the assimilation of radiosonde observations characterizing the near-storm inflow, ii) the assimilation of radar data of varying resolution for model simulations with grid spacings of 1-km and 0.25-km, and iii) to the assimilation of three-dimensional plan-projection-indicator (PPI) and range-height indicator (RHI) radar volumes. Few studies have explored deep convective storm analyses and forecasts produced by assimilation of radar observations to cloud-scale LES. Furthermore, to our knowledge, no storm-scale DA study has explored the value of assimilating high-resolution sector RHI volumes to determine if they can improve the retrieval of the vertical kinematic and microphysical storm structure aloft over the use of traditionally utilized PPI scans.

54 ENVIRONMENTAL SCIENCES↗

Comparing measurements of the mixing layer height to modeled values

The mixing layer height (MLH) is the top layer of turbulent mixing within the lower atmosphere, above the Earth’s surface. Estimates of the mixing layer height allow us to determine the volume available for the dispersion of pollutants throughout the atmosphere. Our goal is to identify the most suitable mixing layer height input for our dispersion modeling tool (AERMOD). For this project we evaluated two different methods of estimating the local mixing layer height. First, we use 3 estimates of the mixing layer height obtained from a ceilometer, each height estimate corresponds to a different gradient in aerosol backscatter which is used as a proxy for mixing layer height identification. Second, we use AERMET, our AERMOD modeling system preprocessor for meteorological data, which estimates the mixing layer height using several equations combined with measured meteorological data. We evaluate the ceilometer and AERMET estimates over a 5-year period (2015-2019) to see how well aligned the estimated mixing layer heights are. Our results suggest that our model, AERMET, is on average, aligned with ceilometer estimates during the daytime hours. However, daily maximum MLH estimates by AERMET occur earlier in the day than those estimated by the ceilometer. We believe that the ceilometer struggles with accurately measuring the MLH during nighttime hours as a result of sensor limitations.

54 ENVIRONMENTAL SCIENCES↗

Influence of facemask design on operational performance

Spirometric measurements of oxygen volume and determination of the amount of argon in exhaled breath are used to analyze facemask design efficiency during treadmill walking tests with subjects carrying plastic hoods filled with argon. Facemask leakage measurements established the better performance of a pneumatic seal type mask in comparison with plain seal type masks.

Griffin, O. G.↗

Pulmonary Edema and Plasma Volume Changes in Dysbarism

Two groups of anesthetized, fasted pigs were utilized. One group of 13 animals (8.5 to 16.6 kilograms) was exposed to a high-pressure environment, and the other group of eight animals (6.9 to 20.0 kilograms) constituted the control group. The experimental group was subjected to an atmosphere of 90 percent nitrogen and 10 percent oxygen at a pressure of 50 psig for 30 minutes and then decompressed at a rate 10 psi/min. Plasma volumes, using both iodine-125-tagged-albumin and chromium-51-tagged-cell dilution techniques, were measured before, immediately after, and at 30 and 60 minutes after decompression. Aortic and right-ventricular systolic pressures were also recorded. At 60 minutes after decompression, blood samples were taken, the animals were sacrificed, and the water content of the lungs, kidneys, livers, and spleens was estimated by measuring tissue wet weight and dry weight. Protein extravasation and tissue blood volumes were determined by measuring the iodine-125-tagged-albumin and chromium-51-tagged-cell spaces in homo-genates of the organs under investigation.

Joki, J. A.↗

Viscosity of liquid anorthite.

The viscosity of liquid anorthite has been determined over the temperature ranges between 1450 to 1620 C and 820 to 950 C. The high-temperature data agree well with previous experimental data and with predictions of the Bottinga and Weill model. The overall log (viscosity) versus 1/T relation exhibits pronounced and rather continuous curvature. The viscosity of anorthite is higher at any given temperature and more strongly temperature-dependent than that of the anorthite-rich lunar compositions 14259, 14310, and 15418. The room-temperature density of glassy anorthite (2.64 gm/cu cm) and the thermal expansion coefficients of glassy and liquid anorthite have also been determined. The volume expansion coefficient for the glass is about 0.000018 per deg C, and that for the liquid is about 0.000048 per deg C. These values are used to relate the high-temperature flow data to the predictions of free-volume theories.

Cukierman, M.↗

Experimental investigations of an 0.0405 scale space shuttle configuration 3 orbiter to determine subsonic stability characteristics (OA21A/OA21B), volume 2

Aerodynamic investigations were conducted in a low speed wind tunnel from June 18 through June 25, 1973 on a 0.0405 scale -139B model Space Shuttle Vehicle orbiter. The purpose of the test was to investigate the longitudinal and lateral-directional subsonic aerodynamic characteristics of the proposed PRR Space Shuttle Orbiter. Emphasis was placed on component buildup effects, elevon, rudder, body flaps, rudder flare effectiveness, and canard and speed brake development. Angles of attack from -4 to 24 and angles of sideslip of -10 to 10 were tested. Static pressures were recorded on the base. The aerodynamic force balance results are presented in plotted and tabular form.

Cameron, B. W.↗