Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

In Situ Monitoring of Crystal Growth Using MEPHISTO, Mission STS 87-Program USMP-4: Experimental Analysis

This report summarizes the results of the In situ Monitoring of Crystal Growth Using MEPHISTO (Material por l'Etude des Phenomenes Interessant de la Solidification sur Terre et en Orbite) experiment on USMP-4. The report includes microstructural and compositional data obtained during the first year of the post flight analysis, as well as numerical simulation of the flight experiment. Additional analyses are being continued and will be reported in the near future. The experiments utilized MEPHISTO hardware to study the solidification and melting behavior of bismuth alloyed with 1 at% tin. The experiments involved repeated melting and solidification of three samples, each approximately 90 cm long and 6mm in diameter. Half of each sample also included a 2 mm. diameter growth capillary, to assist in the formation of single grain inside. One sample provided the Seebeck voltage generated during melting and freezing processes. Another one provided temperature data and Peltier pulsed demarcation of the interface shape for post flight analysis. The third sample provided resistance and velocity measurements, as well as additional thermal data. The third sample was also quenched at the end of the mission to preserve the interface composition for post flight determination. A total of more than 45cm of directionally solidified alloy were directionally solidified at the end of the flight for post mission structural and compositional characterization. Metallurgical analysis of the samples has shown that the interfacial kinetics play a key role in controlling the morphological stability of faceted alloys. Substantial differences were observed in the Seebeck signal between the ground-based experiments and the space-based experiments. The temperature gradient in the liquid for the ground-based experiments was also significantly lower than the temperature gradient in the liquid for the space-based experiments. Both of these observations indicate significant influence of liquid convection for the ground-based experiments.

Abbaschian, Reza↗

Submillimeter-Wave Amplifier Module with Integrated Waveguide Transitions

To increase the usefulness of monolithic millimeter-wave integrated circuit (MMIC) components at submillimeter-wave frequencies, a chip has been designed that incorporates two integrated, radial E-plane probes with an MMIC amplifier in between, thus creating a fully integrated waveguide module. The integrated amplifier chip has been fabricated in 35-nm gate length InP high-electron-mobility-transistor (HEMT) technology. The radial probes were mated to grounded coplanar waveguide input and output lines in the internal amplifier. The total length of the internal HEMT amplifier is 550 m, while the total integrated chip length is 1,085 m. The chip thickness is 50 m with the chip width being 320 m. The internal MMIC amplifier is biased through wire-bond connections to the gates and drains of the chip. The chip has 3 stages, employing 35-nm gate length transistors in each stage. Wire bonds from the DC drain and gate pads are connected to off-chip shunt 51-pF capacitors, and additional off-chip capacitors and resistors are added to the gate and drain bias lines for low-frequency stability of the amplifier. Additionally, bond wires to the grounded coplanar waveguide pads at the RF input and output of the internal amplifier are added to ensure good ground connections to the waveguide package. The S-parameters of the module, not corrected for input or output waveguide loss, are measured at the waveguide flange edges. The amplifier module has over 10 dB of gain from 290 to 330 GHz, with a peak gain of over 14 dB at 307 GHz. The WR2.2 waveguide cutoff is again observed at 268 GHz. The module is biased at a drain current of 27 mA, a drain voltage of 1.24 V, and a gate voltage of +0.21 V. Return loss of the module is very good between 5 to 25 dB. This result illustrates the usefulness of the integrated radial probe transition, and the wide (over 10-percent) bandwidth that one can expect for amplifier modules with integrated radial probes in the submillimeter-regime (>300 GHz).

Samoska, Lorene↗

Hydrophobicity of Cryogenic Fluids for Fuel Transfer in Space Applicaitons

Introduction Hydrophobicity is the tendency of a fluid to repel another material or fluid. Hydrophobiciy can be measured through the wetting angle of the fluid on the surface of the other material. The greater the wetting angle, the more hydrophobic the surface is against the fluid. Hydrophobicity properties can be caused by one of two means, either through physical properties or chemical properties [\citenum{NARBUTT2020121}]. Physical hydrophobicity due to the surface of a solid creating surface roughness/patterning, minimizing the contact area between the fluid and the surface. This can be observed throughout nature, such as the surface of lotus leaves or butterfly wings. This physical property can be induced on a variety of surfaces, namely through laser etching, allowing a surface to be finely lineated to imitate these natural surfaces while controlling quantity, depth, and patterns of the etching on the surface [\citenum{10.1063/1.4905616}]. Physical hydrophobicity is therefore dependent on several variables, including the surface that the fluid is on and properties of the fluid itself, such as density and surface tension, both of which are dependent on temperature and/or pressure. Chemical hydrophobicity [\citenum{MadeiraHydrophobocicicici}] is due to the inherent chemical properties of the materials being used. This is most commonly due to the molecular structures changing the polarity of the materials. Depending on a nonpolar material will repel a polar material, proving to be hydrophobic, conversely if the polarity of the materials is the same (polar – polar, nonpolar – nonpolar), they will attract each other. Cryogenics refers to the behavior of materials at very low temperatures (<\ang{-100} C) [\citenum{ZOHURI20181}]. In space applications many things are inherently cryogenic, therefore this is an important field. There has been little research in how hydrophobicity changes at cryogenic temperatures. Cryogenic fluids are commonly used as fuels for spacecraft, therefore, integrating a hydrophobic surface can increase the transfer rate of the fuel. To test this, several experiments were set up to determine the hydrophobic properties of cryogenic fluids, including nitrogen (LN2), argon (LAr), oxygen (LOx), hydrogen (LH2), and methane (CH4), at cryogenic temperatures. Etched Wafer Testing A silicon wafer cut from a crystal of silicon [100] was used to model the potential hydrophobicity of various cryogenic fluids. Silicon [100] references to the crystallographic orientation of the silicon crystals in the wafer. These wafers were then laser etched to create a surface that is more likely to be hydrophobic. To test the hydrophobicity of the wafers at cryogenic temperatures, the temperatures of the wafers must be reduced to the same temperature as the cryogenic fluid being used to prevent rapid boil-off. To achieve this a double-walled vacuum insulated glass chamber was utilized. The chamber is open, with a double-walled glass that can be placed in a vacuum to remove condensation from the outside to allow easier viewing of the experiment. Furthermore, the silicon wafer's temperature must be lowered to the temperature of LN2, as well as maintain the temperature throughout the experiment. To achieve this a piece of 6061 aluminum was used, creating a stand-off for the wafer and it would allow for the insulation of the temperature of the wafers. The container was then filled with LN2 and once the LN2 stabilized the vaporization and the levels of LN2 dropped under the height of the wafer, the wafer was then allowed to air dry. Once the wafer was dry from the LN2, drops of LN2 were placed on the surface of the wafer for observation. During the first trial, the LN2 that was dropped on the surface displayed nonhydrophobic behaviors, spreading out along the surface, with a minimal wetting angle (too small to be measured). This process was repeated for liquid argon. Further testing with other cryogenic liquids will require different testing apparatuses due to being more volatile. Furthermore, several papers [\citenum{voltvolt7}] have suggested that running a voltage can induce a hydrophobic effect throughout a surface, further testing will include a voltage (constant and oscillating) to determine if voltage influences inducing hydrophobicity at cryogenic temperatures. Chemical Testing Coating the interior walls of the fuel tanks and fuel lines can successfully create a hydrophobic surface. The inherent problem is finding a material that can be used to coat the surface, furthermore, at these temperatures, the coating will remain solid, which could pose issues in maintaining the hydrophobic properties. To test this water (polar) is hydrophobic against oils and fats (nonpolar), therefore the same experiment as the etched wafer testing was conducted to determine if the hydrophobic properties will persist as the nonpolar material remains solid and the polar material remains a fluid. The water remained hydrophobic, allowing testing can expand to the cryogenic fluids. However, another hurdle is faced in finding a chemically opposite material to the cryogenic fluids being tested. As many of the cryogenic fluids being tested are diatomic, they are inherently nonpolar, therefore, the material used for the hydrophobic coating must be polar. Polar greases and lubricants are difficult to come by, however, lithium stearate, appears to be a potential candidate for creating a coated hydrophobic surface for cryogenic fluids at cryogenic temperatures.

Cryogenics↗

Photovoltaic, gravitationally-stabilized solid-state, satellite solar power station /GSS4PS/

The salient feature of a gravitationally-stabilized satellite solar power system (SSPS) for a photovoltaic system is that the large solar array is separated into smaller segments or subunits, joined together in a linear array oriented along the local vertical. Applicability of gravitational stabilization to the design of photovoltaic SSPS is demonstrated. Both actively controlled systems using multiple solar panels oriented to the sun and passively controlled systems requiring no sun orientation are considered and determined to be feasible. Expressions for gravity-gradient induced tension and restoring torques about the local vertical are assessed. Particular attention is directed to the applicability of solid-state approaches to the design of SSPS. It is shown that an all solid-state SSPS utilizing the LITOMIC (light-to-microwave conversion) concept is feasible but that a hybrid system employing a combination of both solid-state and cryogenic cooled low-voltage techniques to the design of the power management and distribution subsystem may also provide a solution.

Cantafio, L. J.↗

Ion beam sputtering of in situ superconducting Y-Ba-Cu-O films

Oriented superconducting YBa2Cu3O7 thin films were deposited on yttria stabilized zirconia and SrTiO3 substrates by ion-beam sputtering of a nonstoichiometric oxide target. The films exhibited zero-resistance critical temperatures as high as 83.5 K without post-deposition anneals. Both the deposition rate and the c-lattice parameter data displayed two distinct regimes of dependence on the beam power of the ion source. Low-power sputtering yielded films with large c-dimensions and low Tc. Higher-power sputtering produced a continuous decrease in the c-lattice parameter and increase in critical temperature. Films having the smaller c-lattice parameters were Cu rich. The Cu content of films deposited at beam voltages of 800 V and above increased with increasing beam power.

Klein, J. D.↗

SOHO Ultraviolet Coronagraph Spectrometer (UVCS) Mission Operations and Data Analysis

The scientific goal of UVCS is to obtain detailed empirical descriptions of the extended solar corona as it evolves over the solar cycle and to use these descriptions to identify and understand the physical processes responsible for coronal heating, solar wind acceleration, coronal mass ejections (CMEs), and the phenomena that establish the plasma properties of the solar wind as measured by "in situ" solar wind instruments. This report covers the period from 15 November 1998 to 14 March 2001. During that time, UVCS observations have consisted of three types: 1) standard synoptic observations comprising, primarily, the H I Lycc line profile and the O VI 103.2 and 103.7 nm intensity over a range of heights from 1.5 to about 3.0 solar radii and covering 360 degrees about the sun, 2) sit and stare watches for CMEs, and 3) special observations designed by the UVCS Lead Observer of the Week for a specific scientific purpose. The special observations are often coordinated with those of other space-based and ground based instruments and they often are part of SOHO joint observation programs and campaigns. Lead observers have included UVCS Co-Investigators, Guest Investigators, scientists from the solar physics community and several graduate and undergraduate level students. UVCS has continued to successfully meet its goal of using powerful spectroscopic diagnostic techniques to obtain a much more detailed description of coronal structures than existed before the SOHO mission. The new descriptions of coronal structures from UVCS have inspired a large number of theoretical studies aimed at identifying the physical processes responsible for solar wind acceleration in coronal holes and streamers. UVCS has proven to be a very stable instrument. Stellar observations have demonstrated its stability and the analysis of coordinated observations with Spartan 201 have verified the accuracy of the absolute calibration and spectral resolution at H I Ly (alpha) line profile. UVCS has required no flight software modifications and all mechanisms are operational. The UVCS O VI Channel with its redundant optical path for wavelengths near H I Ly (alpha) is capable of observing the entire UVCS wavelength range. Since December 1998, the O VI Channel has been used for all UVCS observations. Although the H I Ly (alpha) Channel and detector are still operational, increases in the dark count up to about 5x 10(exp-4) counts/sec/pixel and an increase in high voltage current to within a factor of two of the maximum used in the laboratory before flight led to the decision to not use that detector at the present time. There is no significant science impact since the O VI Channel can observe nearly the same wavelength range.

Kohl, John L.↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗

SOHO Ultraviolet Coronagraph Spectrometer (UVCS) Mission Operations and Data Analysis

The scientific goal of UVCS is to obtain detailed empirical descriptions of the extended solar corona as it evolves over the solar cycle and to use these descriptions to identify and understand the physical processes responsible for coronal heating, solar wind acceleration, coronal mass ejections (CMEs), and the phenomena that establish the plasma properties of the solar wind as measured by "in situ" solar wind instruments. This report covers the period from 15 February 2003 to 14 April 2004. During that time, UVCS observations have consisted of three types: 1) standard synoptic observations comprising, primarily, the H I Lyalpha line profile and the 0 VI 103.2 and 103.7 nm intensity over a range of heights from 1.5 to about 3.0 solar radii and covering 360 degrees about the Sun, 2) sit and stare observations for major flare watches, and 3) special observations designed by the UVCS Lead Observer of the Week for a specific scientific purpose. The special observations are often coordinated with those of other space-based and ground-based instruments and they often are part of SOHO joint observation programs and campaigns. Lead observers have included UVCS Co-Investigators, scientists from the solar physics community and several graduate and undergraduate level students. UVCS has continued to achieve its purpose of using powerful spectroscopic diagnostic techniques to obtain a much more detailed description of coronal structures and dynamic phenomena than existed before the SOHO mission. The new descriptions of coronal mass ejections (CMEs) and coronal structures from UVCS have inspired a large number of theoretical studies aimed at identifying the physical processes responsible for CMEs and solar wind acceleration in coronal holes and streamers. UVCS has proven to be a very stable instrument. Stellar observations have demonstrated its radiometric stability. UVCS has not required any flight software modifications and all mechanisms are operational. The UVCS 0 VI Channel with its redundant optical path for wavelengths near H I Lyalpha is capable of observing the entire UVCS wavelength range. The regions of the detector currently being used require different grating angles for direct OVI observations and redundant path H I Lyalpha observations, and so those can no longer be observed simultaneously. Since December 1998, the 0 VI Channel has been used for all UVCS observations. Although the H I Lyalpha Channel and detector are still operational, increases in the dark count up to about 5x10(exp 4) counts/sec/pixel and an increase in high voltage current to within a factor of two of the maximum used in the laboratory before flight led to the decision to not use that detector after 1998. The visible light channel functioned nominally during the reporting period. UVCS data, data analysis software, calibration files and the mission log are available from the SOHO archive and SAO. All UVCS data are now available within three months of the observations to scientists and the general public via the SOHO Data Archive and SAO. UVCS has resulted in 33 scientific papers in 2003. There were numerous presentations at scientific meetings. UVCS Education and Public Outreach activities involved nine members of the UVCS team. During the reporting period, there were over a dozen events directed at students and teachers, museum audiences, and public audiences via the mass media, internet and educational literature.

Gurman, Joseph↗

Peptides at Membrane Surfaces and their Role in Prebiotic Evolution

Protocells had to transport ions and organic matter across membranes separating the interior of the cell from the environment, capture and utilize energy and transduce environmental signals. In a series of detailed, molecular-level computer simulations we show how these peptides in contact with membranes can acquire ordered structures and functions. We have investigated the stability of a simple alpha-helical peptide containing Leucine (L) and Serine (S) of the form (LSLLLSL)3 in a model membrane system. The parallel in-plane state is the most stable configuration. The transmembrane state is metastable, and about 15 kcal/mol is required to insert the peptide into the membrane. We investigated dimes of both (LSLLLSL)3 and glycophorin A, and show how the free energy of helix association can, at least partially, offset the free energy of insertion. We have also investigated the transmembrane pore of the influenza M2 protein. This aggregate of four identical alpha-helices, each built of 25 amino acids, forms an efficient and selective voltage-gated proton channel. Our simulations explain the gating mechanism, which can involve strands of hydrogen-bonded water through the pore or proton transfer through tautomerization of protein residues. The channel can be re-engineered to act as a simple proton pump.

Pohorille, Andrew↗

Measurements of Siple transmitter signals on the DE 1 satellite - Wave normal direction and antenna effective length

A new experimental technique is developed to simultaneously measure the wave propagation direction and the effective length of a small (L value much smaller than wavelength) electric dipole antenna on a spin-stabilized satellite in the magnetosphere. The technique relies on the near simultaneous measurement of single components of the electric and magnetic fields of a coherent VLF signal injected into the medium from a ground-based source. The spin fading characteristics of the signal received by the electric dipole and the magnetic loop antenna permit the measurement of the wave normal direction assuming whistler-mode propagation. In-situ and remote measurements of the local cold plasma density are used to determine the refractive index. The wave electric field is then inferred from the wave magnetic field as measured on the loop antenna, the refractive index and the direction of propagation. Comparing this electric field with the measured voltage across the dipole antenna leads to the determination of the effective length of the receiving electric dipole. The technique is applied to data from the Dynamics Explorer 1 satellite observations of whistler mode signals injected into the magnetosphere from the Siple, Antarctica, VLF transmitter. In one case, with the measured background cold plasma density being 15 el/cu cm, the effective length of the 200 m-long electric dipole antenna is found to be 222 + or - 56 m, i.e., about twice the conventional value.

Sonwalker, V. S.↗

Maintaining Stability During a Conducted-Ripple EMC Test

An improved technique, and electronic circuitry to implement the technique, have been developed for a military-standard electromagnetic-compatibility (EMC) test in which one analyzes susceptibility to low-frequency ripple conducted into the equipment under test via a DC power line. In the traditional technique for performing the particular test, the ripple is coupled onto the DC power line via a transformer. Depending upon some design details of the equipment under test, the inductance of the transformer can contribute a degree of instability that results in an oscillation of amplitude large enough to destroy the equipment. It is usually possible to suppress the oscillation by connecting a damping resistor to the primary terminals of the ripple-injection transformer. However, it is important to emphasize the usually in the preceding sentence: sometimes, the resistive damping becomes insufficient to suppress destructive oscillation. In addition, undesirably, the resistor contributes to power dissipation and power demand, and thereby also necessitates the use of a larger ripple voltage amplifier. Yet another disadvantage of the transformer-coupling technique is that the transformer introduces low-frequency distortion of the injected ripple voltage. The improved technique makes it possible to inject ripple with very low distortion at low frequency, without inducing oscillation. In this technique, a transformer is not used: Instead, power is fed to the equipment under test via series power field-effect transistors (FETs) controlled by a summing operational amplifier. One of the inputs to the amplifier controls the DC component of the power-line voltage; the other input, generated by an external oscillator, controls the ripple component. The circuitry for implementing this technique includes panel displays, an internal power supply for the operational amplifier and panel displays, and amplitude controls for the DC and ripple powerline voltage components.

Vorperian, Vatche↗

Degradation and ESR Failures in MnO2 Chip Tantalum Capacitors

Equivalent series resistance (ESR) of chip tantalum capacitors determines the rate of energy delivery and power dissipation thus affecting temperature and reliability of the parts. Employment of advanced capacitors with reduced ESR decreases power losses and improves efficiency in power systems. Stability of ESR is essential for correct operations of power units and might cause malfunctioning and failures when ESR becomes too high or too low. Several cases with ESR values in CWR29 capacitors exceeding the specified limit that were observed recently raised concerns regarding environmental factors affecting ESR and the adequacy of the existing screening and qualification testing. In this work, results of stress testing of various types of military and commercial capacitors obtained over years by GSFC test lab and NEPP projects that involved ESR measurements are described. Environmental stress tests include testing in humidity and vacuum chambers, temperature cycling, long-term storage at high temperatures, and various soldering simulation tests. Note that in many cases parts failed due to excessive leakage currents or reduced breakdown voltages. However, only ESR-related degradation and failures are discussed. Mechanisms of moisture effect are discussed and recommendations to improve screening and qualification system are suggested.

Equivalent Series Resistance (ESR)↗

Measurements of Breakdown Field and Forward Current Stability in 3C-SiC P-N Junction Diodes Grown on Step-Free 4H-SiC

This paper reports on initial fabrication and electrical characterization of 3C-SiC p-n junction diodes grown on step-free 4H-SiC mesas. Diodes with n-blocking-layer doping ranging from approx. 2 x 10(exp 16)/cu cm to approx.. 5 x 10(exp 17)/cu cm were fabricated and tested. No optimization of junction edge termination or ohmic contacts was employed. Room temperature reverse characteristics of the best devices show excellent low-leakage behavior, below previous 3C-SiC devices produced by other growth techniques, until the onset of a sharp breakdown knee. The resulting estimated breakdown field of 3C-SiC is at least twice the breakdown field of silicon, but is only around half the breakdown field of <0001> 4H-SiC for the doping range studied. Initial high current stressing of 3C diodes at 100 A/sq cm for more than 20 hours resulted in less than 50 mV change in approx. 3 V forward voltage. 3C-SiC, pn junction, p+n diode, rectifier, reverse breakdown, breakdown field,heteroepitaxy, epitaxial growth, electroluminescence, mesa, bipolar diode

Neudeck, Philip G.↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyance-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chamber are used, distortion of the injected sample stream due to electrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field were not considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyancy-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chambers are used, distortion of the injected sample stream due to electrohydrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field have not been considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

Results of First Long Duration Space Flight of Hybrid Perovskite Thin Film

In support of NASA's Artemis program with the goal of a sustained human-lunar presence, there is a need for very large (>100kW) and high-voltage-capable solar arrays, estimated to cost over $150M. Perovskite-based thin-film photovoltaics offer substantial advantages over state-of-the-art solar arrays from the perspective of manufacturing large arrays. Perovskites have also demonstrated some of the lowest temperature coefficients and highest defect tolerance, which make them excellent candidates for aerospace applications. However, MHPs must demonstrate durability in space which presents different challenges than terrestrial operating environments. To decisively test the viability of perovskites being used in space, a perovskite thin film is positioned in low earth orbit for 10 months on the International Space Station, which was the first long-duration study of an MHP in space. Postflight high-resolution ultrafast spectroscopic characterization and comparison with control samples reveal that the flight sample exhibits superior photo-stability, no irreversible radiation damage, and a suppressed structural phase transition temperature by nearly 65 K, broadening the photovoltaic operational range. Further, significant photo-annealing of surface defects is shown following prolonged light-soaking postflight. These results emphasize that methylammonium lead iodide can be packaged adequately for space missions, affirming that space stressors can be managed as theorized.

William Delmas↗

Nature of convection-stabilized dc arcs in dual-flow nozzle geometry. I - The cold flow field and dc arc characteristics. II - Optical diagnostics and theory

Steady-state low-current air arcs in a dual-flow nozzle system are studied experimentally. The cold flow field with no arc is investigated using a 12.7-mm diameter dual-flow nozzle in a steady-flow facility. Mach number and mass flux distributions are determined for various nozzle-pressure ratios and nozzle-gap spacing. It is found that the shock waves in the converging-diverging nozzles result in a decrease in overal resistance by about 15 percent. Also, Schlieren and differential interferometry techniques are used to visualize the density gradients within the arc plasma and thermal mantle. Both optical techniques reveal a laminar arc structure for a reservoir pressure of 1 atm at various current levels. Experimentally determined axial static pressure and cold-flow mass flux rate distributions and a channel-flow model with constant arc temperatre are used to solve the energy integral for the arc radius as a function of axial distance. The arc electric field strength, voltage, resistance, and power are determined with Ohm's law and the total heat transfer is related to arc power.

Serbetci, Ilter↗

Ion Storage Tests with the High Performance Antimatter Trap (HiPAT)

The NASA/Marshall Space Flight Centers (NASA/MSFC) Propulsion Research Center (PRC) is evaluating an antiproton storage system, referred to as the High Performance Antiproton Trap (HiPAT). This interest stems from the sheer energy represented by matter/antimatter annihilation process with has an energy density approximately 10 order of magnitude above that of chemical propellants. In other terms, one gram of antiprotons contains the equivalent energy of approximately 23 space shuttle external tanks or ET's (each ET contains roughly 740,000 kgs of fuel and oxidizer). This incredible source of stored energy, if harnessed, would be an enabling technology for deep space mission where both spacecraft weight and propulsion performance are key to satisfying aggressive mission requirements. The HiPAT hardware consists of a 4 Tesla superconductor system, an ultra high vacuum test section (vacuum approaching 10(exp -12) torr), and a high voltage confinement electrode system (up to 20 kvolts operation). The current laboratory layout is illustrated. The HiPAT designed objectives included storage of up to 1 trillion antiprotons with corresponding lifetimes approaching 18 days. To date, testing has centered on the storage of positive hydrogen ions produced in situ by a stream of high-energy electrons that passes through the trapping region. However, due to space charge issues and electron beam compression as it passes through the HiPAT central field, current ion production is limited to less then 50,000 ions. Ion lifetime was determined by counting particle populations at the end of various storage time intervals. Particle detection was accomplished by destructively expelling the ions against a micro-channel plate located just outside the traps magnetic field. The effect of radio frequency (RF) stabilization on the lifetime of trapped particles was also examined. This technique, referred to as a rotating wall, made use of a segmented electrode located near the center of the trap on which various phases of a particular frequency were applied. Various experiments were performed illustrating the ability of an RF drive to both prolong and reduced the lifetimes of various ion species depending on the selected frequency. HiPAT is now being reconfigured for testing with an ion source that will provide both positive and negative hydrogen ions from an external source. This ion system shall provide higher fill capacity (order of million of ions per shot), stacking of multiple shots, and injection schemes typical of a realistic antiproton delivery system.

Martin, James J.↗