Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fault-tolerant grid frequency measurement algorithm during transients

A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.

Zhan, Lingwei↗

Estimating Spatial Distribution Impacts of Rooftops Solar PV on Dynamic Hosting Capacity Evaluation for a Real Distribution Feeder

This paper models the sensitivity of dynamic hosting capacity analysis to the spatial distribution of distributed PV scenarios, random, close and far from substation deployments, at various penetration levels on a real distribution feeder, in a quasi-static time series (QSTS) power flow simulation using high resolution time-aware metrics. These spatial distribution scenarios were chosen to capture a wide range of potential operation impacts of these deployments using a set of thermaland voltage-based metrics such as instantaneous violations and moving averages for both thermal and voltage constraints. This study uses actual load and PV data up-scaled from 1-hour time step to 1-minute resolution to fully characterize the interaction between the daily changes in load and PV output, and their impacts on distribution system operations.

distribution system↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States, proposing, assessing, justifying, and illustrating a major infrastructure change involving two of the worlds largest power grids. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.5, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thin-film chemical expansion of ceria based solid solutions: laser vibrometry study

The chemical expansion of Pr 0.1 Ce 0.9 O 2-δ (PCO) and CeO 2-δ thin films is investigated in the temperature range between 600 °C and 800 °C by laser Doppler vibrometry (LDV). It enables non-contact determination of nanometer scale changes in film thickness at high temperatures. The present study is the first systematic and detailed investigation of chemical expansion of doped and undoped ceria thin films at temperatures above 650 °C. The thin films were deposited on yttria stabilized zirconia substrates (YSZ), operated as an electrochemical oxygen pump, to periodically adjust the oxygen activity in the films, leading to reversible expansion and contraction of the film. This further leads to stresses in the underlying YSZ substrates, accompanied by bending of the overall devices. Film thickness changes and sample bending are found to reach up to 10 and several hundred nanometers, respectively, at excitation frequencies from 0.1 to 10 Hz and applied voltages from 0–0.75 V for PCO and 0–1 V for ceria. At low frequencies, equilibrium conditions are approached. As a consequence maximum thin-film expansion of PCO is expected due to full reduction of the Pr ions. The lower detection limit for displacements is found to be in the subnanometer range. At 800 °C and an excitation frequency of 1 Hz, the LDV shows a remarkable resolution of 0.3 nm which allows, for example, the characterization of materials with small levels of expansion, such as undoped ceria at high oxygen partial pressure. As the correlation between film expansion and sample bending is obtained through this study, a dimensional change of a free body consisting of the same material can be calculated using the high resolution characteristics of this system. A minimum detectable dimensional change of 5 pm is estimated even under challenging high-temperature conditions at 800 °C opening up opportunities to investigate electro-chemo-mechanical phenomena heretofore impossible to investigate. The expansion data are correlated with previous results on the oxygen nonstoichiometry of PCO thin films, and a defect model for bulk ceria solid solutions is adopted to calculate the cation and anion radii changes in the constrained films during chemical expansion. The constrained films exhibit anisotropic volume expansion with displacements perpendicular to the substrate plane nearly double that of bulk samples. The PCO films used here generate high total displacements of several 100 nm’s with high reproducibility. Consequently, PCO films are identified to be a potential core component of high-temperature actuators. They benefit not only from high displacements at temperatures where most piezoelectric materials no longer operate while exhibiting, low voltage operation and low energy consumption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ARPA-E PNDIODES "PN Junctions by Ion Implantation" Project (Final Report)

Electricity accounts for nearly 40% of the energy generated in the United States, of which 65% is lost to electrical system inefficiency before reaching end-use sectors. Power electronics will play a growing role in this distribution and end-use, with up to 80% of electricity estimated to pass through power electronics from generation to consumption by 2030. This gives technical improvements in power electronics enormous potential to drive efficiency gains throughout the U.S. economy. Current Si-based power architectures including MOSFETs and IGBTs are limited by high losses, low switching frequency, and poor high-temperature performance. Given the material properties of GaN, devices can exhibit a given turn-on resistance and breakdown voltage with a minute fraction of the area of a Si device—all with higher switching speeds. While n-type doping of III-nitrides has reached a high level of maturity and integration into commercialized products, p-type doping presents distinct challenges that requires continued research. The success of the next generation of GaN-based power devices depends in large part on the ability to form selective-area p-type regions, which can be accomplished by ion implantation of the prevailing acceptor dopant, Mg. This approach is relatively inexpensive and is a fab-ready processing step for creation of current-generation power electronic devices including BJTs, IGBTs, and diode rectifiers. However, ion implantation induces lattice damage and creates point defects within the material, which negatively impacts dopant activation annealing. These forms of damage may be removed by high-temperature annealing, however short annealing time and higher pressures are required to prevent decomposition of the material. We approach this challenge through an innovative combination of approaches toward obtaining high-conductivity p-type GaN. By the novel employment of a gyrotron, a microwave source that can be shaped into a highly localized beam to dissipate very high power in a semiconductor target, a wafer of GaN can be annealed in short (<2 s) ‘pulses’ at temperatures of 1450 °C (2640 °F) to achieve p-type activation without appreciable surface degradation. The p-type activation of Mg-implanted GaN can be further aided by co-implantation with N, believed to enhance the removal of point defects that compensate the acceptors dopant. Elevation to such high temperatures for even a short time induces degradation of GaN-to overcome, we have implemented additional measures to retain high-quality crystalline GaN while removing implant damage and activating Mg dopant. A bilayer cap of AlN is deposited by a combination of chemical and physical vapor deposition to protect the GaN surface. To prevent decomposition of GaN loss of N during annealing, a custom vessel—to contain pressurized N while allowing injection of microwave energy—is employed. By detailed study of the interaction of various measures that are implemented to protect the sample surface (GaN), activate the implanted dopants, and mitigate damage of the lattice heating damage during annealing, we are able to achieve p-type GaN and observe recovery of the crystal and removal of substantial density of defects created during the implantation process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost estimates of production scale semitransparent organic photovoltaic modules for building integrated photovoltaics

Building integrated photovoltaics (BIPVs) are attached to commercial and residential structures to enable solar energy harvesting. While conventional Si photovoltaics (PVs) are dominant in the current market, second and third generation thin film solar cells based on amorphous Si, CdTe, CIGS, perovskites or organic photovoltaics (OPVs) are often considered as an alternative for BIPV applications since they may offer reduced costs compared to Si PVs. Indeed, recent advances in performance suggest that lightweight, flexible and visibly transparent OPVs can potentially be integrated into windows or other applications to which Si PVs are less well suited. Here, we estimate the cost of high efficiency, semitransparent OPVs (ST-OPVs) based on solution processing in a roll-to-roll (R2R) manufacturing line. Assuming modules with 10% power conversion efficiency (PCE), a 70% geometric fill factor (GFF), and 95% inverter efficiency, we anticipate a %1.6 per Wp module manufacturing cost that includes the cost of the microinverter to condition the OPV dc output to be compatible with the ac line voltage of the building. The materials and inverter cost comprise ~90% of the total module cost. Hence, with simplified material synthesis and a lower inverter cost, including marginally improved PCE and GFF, we expect the cost can be as low as $0.47 per Wp. Here, while the module costs ~60% of the average (uninstalled) double-pane window, we expect the payback period can be as short as 2 to 6 years, suggesting that OPVs can be an economic and attractive candidate for BIPV applications.

14 SOLAR ENERGY↗

Portable Soft X-Ray Diagnostics for Transformative Fusion-Energy Concepts (Final Scientific/Technical Report)

A time-gated extreme-ultraviolet spectrometer was fielded on a transformative fusion-energy device, FuZE-Q at Zap Energy, Inc. (ZEI), a sheared-flow-stabilized z-pinch. Plasma emission spectra were collected in the 5–40 nm wavelength (30–250 eV) range. This was the first time a direct-vacuum-coupled, high-voltage, deposition-sensitive diagnostic was fielded on this type of dense-plasma fusion device. To overcome the special challenges of such a coupling, a unique, highly effective implementation was developed, with fast (10-ns risetime) pulsed high-voltage electronics and a multi-stage differential pumping system. This enabled the UNR spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identified oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). Spectral databases and collisional-radiative modeling have been used to identify impurities and estimate edge-plasma temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applying Particle Swarm Optimization and Extended Kalman Filtering to Model Kaplan Generation Dynamics for Hydropower Systems

Variable renewable generation is increasing the need for hydropower plants to provide fast and flexible grid support, which places new demands on plant-level dynamic models used for monitoring, control, and operational decision-making. This need is especially important for hydroelectric systems, where turbine and generator dynamics are strongly coupled, nonlinear, and time-varying, making accurate real-time representation difficult. To address this problem, this paper develops a digital twin (DT) framework for a synchronous generator–Kaplan turbine system using an explicit separation of slow turbine dynamics and fast generator dynamics. The turbine subsystem is represented by a six-coefficient model, whose parameters are identified offline using particle swarm optimization, while the generator subsystem is updated online through an extended Kalman filter for real-time state and parameter estimation. These models are integrated within a closed-loop simulation that includes a proportional–integral–derivative–double-derivative governor and excitation system, allowing the DT to track plant behavior under realistic operating conditions. Unlike prior studies that treat turbine and generator modeling separately or rely mainly on simulated inputs, the proposed framework is validated using real operational data from a hydropower plant. Results show that the DT reproduces terminal voltage, active power, and reactive power with a normalized root mean square error of approximately 5%. This hybrid offline–online formulation constitutes the main contribution of the work, providing an adaptive and practically deployable DT for hydropower systems with direct relevance to control improvement, performance monitoring, and grid-support applications under high renewable penetration.

13 HYDRO ENERGY↗

Experimental Aging and Lifetime Prediction in Grid Applications for Large-Format Commercial Li-Ion Batteries

Due to the growth of electric vehicle and stationary energy storage markets, the production and use of lithium-ion batteries has grown exponentially in recent years. For many of these applications, large-format lithium-ion batteries are being utilized, as large cells have less inactive material relative to their energy capacity and require fewer electrical connections to assemble into packs. And especially for stationary energy storage systems, where energy delivered is the only revenue source, the economics of these battery systems is highly dependent on cell lifetime. However, testing of large-format lithium-ion batteries is time consuming and requires high current channels and large testing chambers, making information on the performance of commercial, large-format lithium-ion batteries hard to come by. Here, accelerated aging test data from four commercial large-format lithium-ion batteries is reported. These batteries span both NMC-Gr and LFP-Gr cell chemistries, pouch and prismatic formats, and a range of cell designs with varying power capabilities. Accelerated aging test results are analyzed to examine both cell performance, in terms of efficiency and thermal response under load, as well as cell lifetime. Cell thermal response is characterized by measuring temperature during cycle aging, which is used to calculated a normalized thermal resistance value that may help estimate both cell cooling needs or to help extrapolate aging test results to different thermal environments. Cell lifetime is evaluated qualitatively, considering simply the average calendar and cycle life across a range of conditions, as well as quantitatively, using statistical modeling and machine-learning methods to identify predictive aging models from the accelerated aging data. These predictive aging models are then used to investigate cell sensitivities to stressors, such as cycling temperature, voltage window, and C-rate, as well as to predict cell lifetime in various stationary storage applications. Results from this work show that cell lifetime and sensitivity to aging conditions varies substantially across commercial cells, necessitating testing for specific cell formats to make quantitative lifetime predictions. That being said, all commercial cells tested here are predicted to reach at least 10-year lifetimes for stationary storage applications. Based on the aging test results and modeling, some cells are expected to be relatively insensitive to temperature and use-case, making them suited for simple use cases with little or no thermal management and simple controls, while the lifetime of other cells could be extended to 20+ years if operated with thermal management and degradation-aware controls.

battery↗

Construction of Cryogen-Free 4.3T Superconducting Wiggler for NSLS-II Ring

With the 3 GeV electron beam energy for the National Synchrotron Light Source II (NSLS-II) ring, only superconducting wigglers (SCW) producing greater than 4T peak field can cover the photon energy range of 20 keV and 200 keV with sufficient number of photons. The High energy Engineering X-ray (HEX) Diffraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70 mm period length and 4.3 T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aperture of 8 mm is made from 316LN stainless steel and copper plating is applied both surface and +-12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10 W/m. Here, we describe the design principles and engineering challenges for the device.

36 MATERIALS SCIENCE↗

Generalized and Mechanistic PV Module Performance Prediction From Computer Vision and Machine Learning on Electroluminescence Images

Electroluminescence (EL) imaging of photovoltiac (PV) modules offers high-speed, high-resolution information about device performance, affording opportunities for greater insight and efficiency in module characterization across manufacturing, research and development, and power plant operations and management. Predicting module electrical properties from EL image features is a critical step toward these applications. In this article, we demonstrate quantification of both generalized and performance mechanism-specific EL image features, using pixel intensity-based and machine learning classification algorithms. From EL image features, we build predictive models for PV module power and series resistance, using time-series current-voltage (I-V) and EL data obtained stepwise on five brands of modules spanning three Si cell types through two accelerated exposures: damp heat (DH) (85°C/85% RH) and thermal cycling (TC) (IEC 61215). Overall, 195 pairs of EL images and I-V characteristics were analyzed, yielding 11700 individual PV cell images. A convolutional neural network was built to classify cells by the severity of busbar corrosion with high accuracy (95%). Generalized power predictive models estimated the maximum power of PV modules from EL images with high confidence and an adjusted-R 2 of 0.88, across all module brands and cell types in extended DH and TC exposures. Mechanistic degradation prediction was demonstrated by quantification of busbar corrosion in EL images of three module brands in DH, and subsequent modeling of series resistance using these mechanism-specific EL image features. For modules exhibiting busbar corrosion, we demonstrated series resistance predictive models with adjusted-R 2 of up to 0.73.

14 SOLAR ENERGY↗

Estimating the impact of tariff-driven behind-the-meter storage operation on distribution grid investments

Increasing growth of distributed solar photovoltaics (PV) and electric vehicles (EV) can strain local distribution networks and require costly upgrades. Distributed battery storage, often deployed alongside PV, can be used to mitigate those costs, depending on how batteries are operated. This study evaluates the potential deferral value of distributed battery storage across a range of tariff structures, focusing on the rate structures most commonly available to residential customers today and related variants. Deferrals are evaluated with a least-cost distribution grid expansion optimization model to identify requirements on line reconductoring, transformer upgrades, and voltage regulator installations under each tariff. Results show that TOU rates and net billing tariffs can yield meaningful deferral value, depending on specific tariff structure features. Under the best performing tariff structure tested, storage produced a median annualized deferral value of $7.18 per kW of storage capacity ( kW S ) across all feeders in the sample, though deferral values were considerably larger for feeders with peak loads that coincide with utility system peak, i.e., timing of TOU peak period. In contrast, under an unrestricted TOU design with no restrictions on grid charging or discharging, the median deferral value was $0/ kW S illustrating the critical importance of tariff structure details.

Rodriguez-Garcia, Luis↗

Simulating Discharge Curves of an All-Aqueous TRAB to Identify Pathways for Improving System Performance

Thermally regenerative ammonia batteries (TRABs) are an emerging technology that use low temperature heat (T < 150 °C) to recharge a flow battery that produces electrical power on demand. The all-aqueous copper TRAB can provide high power densities and thermal energy efficiencies relative to other devices that harvest energy from waste heat, but its performance is adversely impacted by the crossover of undesired species through the membrane and lower cell voltages compared to conventional batteries. In this work, we developed a numerical model to simulate discharge curves while accounting for crossover inefficiencies without tracking all electrolyte species through the membrane. The model was able to successfully reproduce discharge curves across a diverse range of battery conditions using a single fitting parameter to account for decay of electrode standard potential due to species crossover with minimal error (< 5%). The model was then used to simulate different design scenarios to estimate changes in energy output from alterations to the aspects of the battery electrolyte chemistry. Results from this study are used to identify pathways for improving future TRAB designs with respect to energy capacity and cost-effectiveness of the technology.

25 ENERGY STORAGE↗

Multiple Operando Fields Can Identify a Predictive Mass Transport Theory in Electrolytes

An electrolyte transport theory connects its transport properties, evolution of spatiotemporal fields (e.g., concentration), and corresponding macroscopic current and voltage responses. Given this interconnection, the transport properties are typically inferred by analyzing the macroscopic response through the lens of a chosen electrolyte transport theory. Unfortunately, the same macroscopic measurements can be analyzed by using different theories to arrive at seemingly dissimilar properties that are inconsistent with each other. Here, we offer a resolution to this dilemma by analyzing multiple spatiotemporal (i.e., operando) fields for a given electrolyte. We show that predictive transport theory can analyze operando fields to estimate underlying transport properties and subsequently predict another operando field. A theory passing this test identifies meaningful transport properties such that the electrolyte behavior can be accurately predicted over a wide range of excitations, and is critical to property-based electrolyte screening and electrolyte discovery efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗