A novel photonic oscillator

We report a novel oscillator for photonic RF systems. This oscillator is capable of generating high-frequency signals up to 70 GHz in both electrical and optical domains and is a special voltage-controlled oscillator with an optical output port. It can be used to make a phase-locked loop (PLL) and perform all functions that a PLL is capable of for photonic systems. It can be synchronized to a reference source by means of optical injection locking, electrical injection locking, and PLL. It can also be self-phase locked and self-injection locked to generate a high-stability photonic RF reference. Its applications include high-frequency reference regeneration and distribution, high-gain frequency multiplication, comb-frequecy and square-wave generation, carrier recovery, and clock recovery. We anticipate that such photonic voltage-controlled oscillators (VCOs) will be as important to photonic RF systems as electrical VCOs are to electrical RF systems.

Yao, X. S.↗

Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators

Two modern cryogenic variants of the Pound circuit have been devised to increase the frequency stability of microwave oscillators that include cryogenic sapphire-filled cavity resonators. The original Pound circuit is a microwave frequency discriminator that provides feedback to stabilize a voltage-controlled microwave oscillator with respect to an associated cavity resonator. In the present cryogenic Pound circuits, the active microwave devices are implemented by use of state-of-the-art commercially available tunnel diodes that exhibit low flicker noise (required for high frequency stability) and function well at low temperatures and at frequencies up to several tens of gigahertz. While tunnel diodes are inherently operable as amplitude detectors and amplitude modulators, they cannot, by themselves, induce significant phase modulation. Therefore, each of the present cryogenic Pound circuits includes passive circuitry that transforms the AM into the required PM. Each circuit also contains an AM detector that is used to sample the microwave signal at the input terminal of the high-Q resonator for the purpose of verifying the desired AM null at this point. Finally, each circuit contains a Pound signal detector that puts out a signal, at the modulation frequency, having an amplitude proportional to the frequency error in the input signal. High frequency stability is obtained by processing this output signal into feedback to a voltage-controlled oscillator to continuously correct the frequency error in the input signal.

Dick, G. John↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE↗

Graph Convolutional Network-Based Topology Embedded Deep Reinforcement Learning for Voltage Stability Control

Topological variations in power system is a common phenomenon and can impose significant challenges to traditional controllers of power system. Recent study revealed the strength of deep reinforcement learning (DRL) based approaches in power system preventive and corrective control. But topological variations are difficult to capture using classical fully connected neural network (FCN) model and has not been explicitly modeled in previous work. Hence, we develop a Graph Convolutional Network (GCN) based DRL framework to tackle topology changes in control design of power system. The GCN model exploits the graph structure of the power network and helps the DRL agent to embed the topology information during learning process. Our GCN based approach is evaluated using the IEEE-39 bus system and it outperforms the FCN-based DRL scheme in terms of training convergence and control performance considering grid topology changes.

Hossain, Ramij Raja↗

Voltage-programed control of turboalternator load

A power source and load-control concept was designed and tested for use with a Brayton cycle turboalternator. The concept provides power that adjusts to a range of loads while controlling alternator speed and isolating load-switching transients. The concept is also applicable to power-generating sources other than the Brayton cycle.

Young, R. N.↗

Controllable high voltage source having fast settling time

A high voltage dc stepping power supply for sampling a utilization device such as an electrostatic analyzer has a relatively fast settling time for voltage steps. The supply includes a waveform generator for deriving a low voltage staircase waveform that feeds a relatively long response time power supply, deriving a high output voltage generally equal to a predetermined multiple of the input voltage. In the power supply, an ac voltage modulated by the staircase waveform is applied to a step-up transformer and then to a voltage multiplier stack to form a high voltage, relatively poor replica of the input waveform at an intermediate output terminal. A constant dc source, applied to the input of the power supply, biases the voltage at the intermediate output terminal to be in excess of the predetermined multiple of the input voltage.

Doong, H.↗

Network-cognizant voltage droop control

The present disclosure provides techniques for network-cognizant droop control in power systems, such as a power distribution system. An example device includes a processor configured to determine, based on (i) a model representing a structure of a power system that includes a plurality of energy resources and (ii) an indication of predicted uncontrollable power injections in the power system, for each controllable energy resource in the plurality of energy resources, a respective value of a first droop coefficient and a respective value of a second droop coefficient. The processor may be further configured to cause at least one controllable energy resource in the plurality of energy resources to modify an output power of the at least one energy resource based on the respective value of the first droop coefficient and the respective value of the second droop coefficient.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Side Voltage and PQ Control with Inverter-based Photovoltaic Systems

Distributed energy resources (DER) are small generators located close to the load centers. The DERs that are integrated to the grid with the power electronic converter interfaces are capable of providing nonactive power in addition to active power. Hence, they are capable of regulating the voltages of the weak buses in the distribution systems. This paper discusses the voltage control capability of photovoltaic (PV) systems as compared to the traditional capacitor banks. The simulation results prove the effectiveness of dynamic voltage control capability of inverter-based PV. With the proper control algorithm, the active and nonactive power from the DERs like battery banks or solar photovoltaic can be controlled independently. This paper also presents the scenario of controlling the active and nonactive power from the PV array to track and supply the local load.

99 GENERAL AND MISCELLANEOUS↗

Tabletop Testing for EV Charging Ecosystem PKI (Project T34PKI Final Report)

To test the communications and cybersecurity functionality, Electric Vehicle and charging station vendors have had to ship their products to in-person testing events. This is cumbersome, expensive, inefficient, and an impediment to rapid time-to-deployment. In this project Sandia used COTS hardware and Open-Source Software to develop and demonstrate a more agile, productive approach: testing low-voltage controllers independently from high-voltage power delivery sub-systems. This approach allows communications controllers to be transported easily (e.g. shipped at low cost, checked as airline baggage); set up on a table-top (“bench testing”); and use ordinary 120 VAC outlets to conduct agile testing. Table-top platforms become end nodes that can connect to laboratory and cloud-based servers to test communications and cybersecurity, specifically Public Key Infrastructure (PKI) functionality and interoperability, separately from EV battery charging (power/energy transfer) functionality.

33 ADVANCED PROPULSION SYSTEMS↗

A VSM-Based DER Dispatch MINLP for Volt-VAR Control in Unbalanced Power Distribution Systems

This paper presents an optimal dispatch algorithm to coordinate customer-owned controllable loads and smart solar inverters with utility-owned voltage regulators and capacitors to meet voltage control objectives. The optimization problem is formulated as a mixed-integer nonlinear programming (MINLP) problem. A voltage sensitivity matrix (VSM) is used to linearize the effect of control actions on the voltage at customer nodes when solving the MINLP. The VSM is recalculated at each time step to improve the computational accuracy. Both discrete switching actions of the capacitor and VRs and the continuous adjustment of real and reactive power from load and smart inverters are considered in the MINLP volt-var problem formulation. The objective function minimizes the cost of all control actions and the magnitude of voltage fluctuations from the previous time period. Constraints ensure that the voltage at each node is maintained within ANSI limits and the feeder power factor is controlled within the desired range. The algorithm is tested using an actual 3-phase unbalanced distribution feeder model. Simulation results demonstrate that the proposed algorithm is computationally feasible on real circuits and improves voltage control while minimizing operational costs.

McEntee, Catie↗