Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Real-Tme Boron Nitride Erosion Measurements of the HiVHAc Thruster via Cavity Ring-Down Spectroscopy

Cavity ring-down spectroscopy was used to make real-time erosion measurements from the NASA High Voltage Hall Accelerator thruster. The optical sensor uses 250 nm light to measure absorption of atomic boron in the plume of an operating Hall thruster. Theerosion rate of the High Voltage Hall Accelerator thruster was measured for discharge voltages ranging from 330 to 600 V and discharge powers ranging from 1 to 3 kW. Boron densities as high as 6.5 x 10(exp 15) per cubic meter were found within the channel. Using a very simple boronvelocity model, approximate volumetric erosion rates between 5.0 x 10(exp -12) and 8.2 x 10(exp -12) cubic meter per second were found.

Hall thruster↗

Design Guidelines of a Double-Gap Microwave Rebuncher Cavity for a 400 MHz, 2.5 MeV Energy Light Ion Accelerator with Lower Gap Voltage and Field

Here, a detailed electromagnetic model of a double-gap microwave rebuncher cavity proposed for 400-MHz, 2.5 MeV energy of the front end section in 1 GeV energy H- ion linear accelerator, is presented and validated by extensive simulations. This design is intended to decrease both the utilized gap voltage and peak electric field of the rebunching cavity, henceforth may decrease X-ray radiation. A low cost 1/2 scaled aluminum cavity double gap model was built and tested for model validation. Mode frequencies and quality factors of the model were measured and compared to simulation. Additionally, bead perturbation method was used to measure the para-axial electric field. Simulation of the single and double gap cavities were compared to measurements and were in very good agreement. Subsequently, design guidelines have been developed to design the double gap rebuncher, optimize its gap size for lower electric fields and reduced X-ray radiation.

43 PARTICLE ACCELERATORS↗

Compact, high-efficiency accelerators driven by low-voltage solid-state amplifiers

A compact particle accelerator can include two or more cavities disposed along an axis of the particle accelerator, each of which is coupled to two or more drivers. The accelerator can also include a power supply coupled to the two or more drivers such that a particle beam traveling along the axis is accelerated. The power supply can be an interface with a commercial power outlet, battery power, or a combination thereof depending upon the use case. Example configurations of the accelerator include hand held or mobile devices that are capable of delivering up to and greater than a 1 MeV electron beam.

42 ENGINEERING↗

Compact, high-efficiency accelerators driven by low-voltage solid-state amplifiers

A compact particle accelerator can include two or more cavities disposed along an axis of the particle accelerator, each of which is coupled to two or more drivers. The accelerator can also include a power supply coupled to the two or more drivers such that a particle beam traveling along the axis is accelerated. The power supply can be an interface with a commercial power outlet, battery power, or a combination thereof depending upon the use case. Example configurations of the accelerator include hand held or mobile devices that are capable of delivering up to and greater than a 1 MeV electron beam.

Nguyen, Dinh Cong↗

Correlations of Capacitance-Voltage Hysteresis with Thin-Film CdTe Solar Cell Performance During Accelerated Lifetime Testing

In this paper we present the correlation of CdTe solar cell performance with capacitance-voltage hysteresis, defined presently as the difference in capacitance measured at zero-volt bias when collecting such data with different pre-measurement bias conditions. These correlations were obtained on CdTe cells stressed under conditions of 1-sun illumination, open-circuit bias, and an accelerationtemperature of approximately 100 degrees C.

14 SOLAR ENERGY↗

Accelerator System Development at High Voltage Engineering

Throughout the years, HVE has continuously extended the capabilities of its accelerator systems to meet the rising demands from a diverse field of applications, among which are deep level ion implantation, micro-machining, neutron production for biomedical research, isotope production or accelerator mass spectrometry. Characteristic for HVE accelerators is the coaxial construction of the all solid state power supply around the acceleration tubes. With the use of solid state technology, the accelerators feature high stability and very low ripple. Terminal voltages range from 1 to 6 MV for HVE Singletrons and Tandetrons. The high-current versions of these accelerators can provide ion beams with powers of several kW. In the last years, several systems have been built with terminal voltages of 1.25 MV, 2 MV and 5 MV. Recently, the first system based on a 6 MV Tandetron has passed the factory tests. In this paper we describe the characteristics of the HVE accelerator systems and present as example recent systems.

43 PARTICLE ACCELERATORS↗

Characterization of ion accelerating systems on NASA LeRC's ion thrusters

An investigation is conducted regarding ion-accelerating systems for two NASA thrusters to study the limits of ion-extraction capability or perveance. A total of nine two-grid ion-accelerating systems are tested with the 30- and 50-cm-diam ring-cusp inert-gas ion thrusters emphasizing the extension of ion-extraction. The vacuum-tank testing is described using xenon, krypton, and argon propellants, and thruster performance is computed with attention given to theoretical design considerations. Reductions in perveance are noted with decreasing accelerator-hole-to-screen-hole diameter ratios. Perveance values vary indirectly with the ratio of discharge voltage to total accelerating voltage, and screen/accelerator electrode hole-pair alignment is also found to contribute to perveance values.

Rawlin, Vincent K.↗

Degradation of Leakage Currents and Reliability Prediction for Tantalum Capacitors

Two types of failures in solid tantalum capacitors, catastrophic and parametric, and their mechanisms are described. Analysis of voltage and temperature reliability acceleration factors reported in literature shows a wide spread of results and requires more investigation. In this work, leakage currents in two types of chip tantalum capacitors were monitored during highly accelerated life testing (HALT) at different temperatures and voltages. Distributions of degradation rates were approximated using a general log-linear Weibull model and yielded voltage acceleration constants B = 9.8 +/- 0.5 and 5.5. The activation energies were Ea = 1.65 eV and 1.42 eV. The model allows for conservative estimations of times to failure and was validated by long-term life test data. Parametric degradation and failures are reversible and can be annealed at high temperatures. The process is attributed to migration of charged oxygen vacancies that reduce the barrier height at the MnO2/Ta2O5 interface and increase injection of electrons from the MnO2 cathode. Analysis showed that the activation energy of the vacancies' migration is ~ 1.1 eV.

acceleration factors↗

Resistive foil edge grading for accelerator and other high voltage structures

In a structure or device having a pair of electrical conductors separated by an insulator across which a voltage is placed, resistive layers are formed around the conductors to force the electric potential within the insulator to distribute more uniformly so as to decrease or eliminate electric field enhancement at the conductor edges. This is done by utilizing the properties of resistive layers to allow the voltage on the electrode to diffuse outwards, reducing the field stress at the conductor edge. Preferably, the resistive layer has a tapered resistivity, with a lower resistivity adjacent to the conductor and a higher resistivity away from the conductor. Generally, a resistive path across the insulator is provided, preferably by providing a resistive region in the bulk of the insulator, with the resistive layer extending over the resistive region.

42 ENGINEERING↗

The Degradation Mitigation Effect of Cerium Oxide in Polymer Electrolyte Membranes in Extended Fuel Cell Durability Tests

In this work, two formulations of single-crystal cerium oxide nanoparticles of varying particle sizes were incorporated into perfluorosulfonic acid membrane electrode assemblies (MEAs) and their ability to improve the in-situ membrane durability was studied by subjecting them to 94 and 500 hours open-circuit voltage hold accelerated durability tests . In the shorter test the open circuit voltage decay rate was reduced by half and the fluoride emission by at least one order of magnitude, though no effect on hydrogen crossover or performance of the baseline MEAs was measured. The presence of the additive increased the particle size but decreased the number of platinum catalyst particles that were deposited in the membrane. The main Pt band was found at the predicted location; however, the incorporation of ceria caused a broadening with particles reaching further into the membrane. In 500 h tests, ceria-containing MEAs demonstrated a seven-fold decrease in open-circuit voltage decay and three order of magnitude reduction in fluoride emission rates with unchanged performance and hydrogen crossover, remaining effectively pristine whilst the baseline MEA underwent catastrophic failure.

Pearman, Benjamin P↗

Voltage stress effects on microcircuit accelerated life test failure rates

The applicability of Arrhenius and Eyring reaction rate models for describing microcircuit aging characteristics as a function of junction temperature and applied voltage was evaluated. The results of a matrix of accelerated life tests with a single metal oxide semiconductor microcircuit operated at six different combinations of temperature and voltage were used to evaluate the models. A total of 450 devices from two different lots were tested at ambient temperatures between 200 C and 250 C and applied voltages between 5 Vdc and 15 Vdc. A statistical analysis of the surface related failure data resulted in bimodal failure distributions comprising two lognormal distributions; a 'freak' distribution observed early in time, and a 'main' distribution observed later in time. The Arrhenius model was shown to provide a good description of device aging as a function of temperature at a fixed voltage. The Eyring model also appeared to provide a reasonable description of main distribution device aging as a function of temperature and voltage. Circuit diagrams are shown.

Johnson, G. M.↗

Testing and Analysis for Lifetime Prediction of Crystalline Silicon PV Modules Undergoing Degradation by System Voltage Stress: Preprint

Acceleration factors are calculated for crystalline silicon PV modules under system voltage stress by comparing the module power during degradation outdoors to that in accelerated testing at three temperatures and 85% relative humidity. A lognormal analysis is applied to the accelerated lifetime test data considering failure at 80% of the initial module power. Activation energy of 0.73 eV for therate of failure is determined, and the probability of module failure at an arbitrary temperature is predicted. To obtain statistical data for multiple modules over the course of degradation in-situ of the test chamber, dark I-V measurements are obtained and transformed using superposition, which is found well suited for rapid and quantitative evaluation of potential-induced degradation. It isdetermined that shunt resistance measurements alone do not represent the extent of power degradation. This is explained with a two-diode model analysis that shows an increasing second diode recombination current and ideality factor as the degradation in module power progresses. Failure modes of the modules stressed outdoors are examined and compared to those stressed in accelerated tests.

14 SOLAR ENERGY↗

Electron Backstreaming Mitigation via a Magnetic Grid

Electron backstreaming due to accelerator grid hole enlargement has been identified as a failure mechanism that will limit ion thruster service lifetime. Over extended periods of time as accelerator grid apertures enlarge due to erosion, ion thrusters are required to operate at increasingly higher accelerator grid voltages in order to prevent electron backstreaming. These higher voltages give rise to higher grid erosion rates, which in turn accelerates aperture enlargement. Presented here is an approach to mitigate the backflow of electrons into the engine by using a transverse magnetic field.

Foster, John F.↗

Theory of an Electromagnetic Mass Accelerator for Achieving Hypervelocities

It is shown that for any electromagnetic accelerator which employs an electromagnetic force for driving the projectile and uses the projectile as the heat sink for the energy dissipated in it by ohmic heating, the maximum velocity attainable without melting is a function of the mass of the projectile. Therefore, for hypervelocities a large projectile mass is required and thus a power supply of very large capacity is necessary. It is shown that the only means for reducing the power requirement is maximizing the gradient of the mutual inductance. In the scheme of the sliding-coil accelerator investigated herein, the gradient of the mutual inductance is continuously maintained at a high value. It is also shown that for minimum length of the accelerator, the current must be kept constant despite the rise in induced voltage during acceleration. The use of a capacitor bank as an energy source with the condition that the current be kept constant is investigated. Experiments at low velocities are described.

Thom, Karlheinz↗