Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ventilators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emptying patterns of the lung studied by multiple-breath N2 washout

Changes in the nitrogen concentration seen during the single-breath nitrogen washout reflect changes in relative flow (ventilation) from units with differing ventilation/volume ratios. The multiple-breath washout provides sufficient data on ventilation for units with varying ventilation/volume ratios to be plotted as a function of the volume expired. Flow from the dead space may also be determined. In young normals the emptying patterns are narrow and unimodal throughout the alveolar plateau with little or no flow from the dead space at the end of the breath. Older normals show more flow from the dead space, particularly toward the end of the breath, and some show a high ventilation/volume ratio mode early in the breath. Patients with obstructive lung disease have a high flow from the dead space which is present throughout the breath. A well ventilated mode at the end of the breath is seen in some obstructed subjects. Patients with cystic fibrosis showed a poorly ventilated mode appearing at the end of the breath as well as a very high dead space.

Lewis, S. M.↗

Convective heat transfer from circular cylinders located within perforated cylindrical shrouds

The influence of perforated cylindrical shrouds on the convective heat transfer to circular cylinders in transverse flow has been studied experimentally. Geometries studied were similar to those used in industrial platinum resistance thermometers. The influence of Reynolds number, ventilation factor (ratio of the open area to the total surface area of shroud), radius ratio (ratio of shroud's inside radius to bare cylinder's radius), and shroud orientation with respect to flow were studied. The experiments showed that perforated shrouds with ventilation factors in the range 0.1 to 0.4 and radius ratios in the range 1.1 to 2.1 could enhance the convective heat transfer to bare cylinders up to 50%. The maximum enhancement occurred for a radius ratio of 1.4 and ventilation factors between 0.2 and 0.3. It was found that shroud orientation influenced the heat transfer, with maximum heat transfer generally occurring when the shroud's holes were centered on either side of the stagnation line. However, the hole orientation effect is of second order compared to the influence of ventilation factor and radius ratio.

Daryabeigi, K.↗

Using spacecraft trace contaminant control systems to cure sick building syndrome

Many residential and commercial buildings with centralized, recirculating, heating ventilation and air conditioning systems suffer from 'Sick Building Syndrome.' Ventilation rates are reduced to save energy costs, synthetic building materials off-gas contaminants, and unsafe levels of volatile organic compounds (VOC's) accumulate. These unsafe levels of contaminants can cause irritation of eyes and throat, fatigue and dizziness to building occupants. Increased ventilation, the primary method of treating Sick Building Syndrome is expensive (due to increased energy costs) and recently, the effectiveness of increased ventilation has been questioned. On spacecraft venting is not allowed, so the primary methods of air quality control are; source control, active filtering, and destruction of VOC's. Four non-venting contaminant removal technologies; strict material selection to provide source control, ambient temperature catalytic oxidation, photocatalytic oxidation, and uptake by higher plants, may have potential application for indoor air quality control.

Graf, John C.↗

Hydrodynamic Characteristics of Two Low-Drag Supercavitating Hydrofoils

An experimental investigation has been conducted in Langley tank no. 2 to determine the hydrodynamic characteristics of two low-drag supercavitating hydrofoils operating in a range of cavitation numbers from 0 to approximately 6. The hydrofoils had aspect ratios of 1 and 3, and the sections were derived by assuming five terms in the vorticity-distribution expansion of the equivalent airfoil. The aspect-ratio-1 hydrofoil was also tested at zero cavitation number with two sets of end plates having depths of 3/8 and 1/4 chords. Zero cavitation number was established by operating the hydrofoils near the water surface so that complete ventilation of the upper surfaces could be obtained. For those depths of submersion where complete ventilation was not obtained through vortex ventilation, two probes were used to introduce air to the upper surfaces of the hydrofoils and to induce complete ventilation. Data were obtained for a range of speeds from 20 to 80 fps, angles of attack from 2 to 20 deg, and ratios of depth of submersion to chord from 0 to 0.85. The experimental results obtained from the aspect-ratio-1 and aspect-ratio-3, five-term hydrofoils were compared with a three-dimensional zero-cavitation-number theory. The theoretical and experimental values of lift and center of pressure for the aspect-ratio-1 hydrofoil were in agreement, within engineering accuracy, for the range of lift coefficients investigated. The theoretical drag coefficients were lower, by a constant amount, than the experimental drag coefficients. The theoretical expressions derived for the lift, drag, and center of pressure of the aspect-ratio-3 hydrofoil were in agreement, within engineering accuracy, with the experimental values. The theoretical and experimental drag coefficients of the aspect-ratio-3 five-term hydrofoil were lower than the theoretical drag coefficients computed for a comparable Tulin-Burkart hydrofoil.

McGehee, John R.↗

Hypergravity Alters the Susceptibility of Cells to Anoxia-Reoxygenation Injury

Gravity is a physical force, much like shear stress or mechanical stretch, and should affect organ and cellular function. Researchers have shown that gravity plays a role in ventilation and blood flow distribution, gas exchange, alveolar size and mechanical stresses within the lung. Short exposure to microgravity produced marked alterations in lung blood flow and ventilation distribution while hypergravity exaggerated the regional differences in lung structure and function resulting in reduced ventilation at the base and no ventilation of the upper half of the lung. Microgravity also decreased metabolic activity in cardiac cells, WI-38 embryonic lung cells, and human lymphocytes. Rats, in the tail-suspended head-down tilt model, experienced transient loss of lung water, contrary to an expected increase due to pooling of blood in the pulmonary vasculature. Hypergravity has also been found to increase the proliferation of several different cell lines (e.g., chick embryo fibroblasts) while decreasing cell motility and slowing liver regeneration following partial hepatectomy. These studies show that changes in the gravity environment will affect several aspects of organ and cellular function and produce major change in blood flow and tissue/organ perfusion. However, these past studies have not addressed whether ischemia-reperfusion injury will be exacerbated or ameliorated by changes in the gravity environment, e.g., space flight. Currently, nothing is known about how gravity will affect the susceptibility of different lung and vascular cells to this type of injury. We conducted studies that addressed the following question: Does the susceptibility of lung fibroblasts, vascular smooth muscle, and endothelial cells to anoxia/reoxygenation injury change following exposure to hypergravity conditions?

McCloud, Henry↗

Nonlinear Oscillations and Flow of Gas Within Closed and Open Conical Resonators

A dissonant acoustic resonator with a conical shaped cavity was tested in four configurations: (A) baseline resonator with closed ends and no blockage; (B) closed resonator with internal blockage; (C) ventilated resonator with no blockage; and (D) ventilated resonator with an applied pressure differential. These tests were conducted to investigate the effects of blockage and ventilation holes on dynamic pressurization. Additionally, the investigation was to determine the ability of acoustic pressurization to impede flow through the resonator. In each of the configurations studied, the entire resonator was oscillated at the gas resonant frequency while dynamic pressure, static pressure, and temperature of the fluid were measured. In the final configuration, flow through the resonator was recorded for three oscillation conditions. Ambient condition air was used as the working fluid. The baseline results showed a marked reduction in the amplitude of the dynamic pressure waveforms over previously published studies due to the use of air instead of refrigerant as the working fluid. A change in the resonant frequency was recorded when blockages of differing geometries were used in the closed resonator, while acoustic pressure amplitudes were reduced from baseline measurements. A sharp reduction in the amplitude of the acoustic pressure waves was expected and recorded when ventilation ports were added. With elevated pressure applied to one end of the resonator, flow was reduced by oscillating the cavity at the fluid fundamental resonant frequency compared to cases without oscillation and oscillation off-resonance.

Daniels, Christopher↗

Hypercapnic ventilatory response in humans before, during, and after 23 days of low level CO2 exposure

Alterations in ventilation and the chemoreceptor response to CO2 during 23 d of 1.2% inspired CO2 were studied in four male subjects. Resting ventilation (VE), tidal volume (VT), respiratory frequency (fR), inspired and end tidal O2 and CO2 and the hypercapnic ventilatory response (HCVR) measured by CO2 rebreathing were measured once before entering the chamber, on days 2, 5, 11, and 22 of CO2 exposure, and one day after. Resting VE slightly increased (5%) on day 2 of exposure and significantly increased (22%) by day 5 followed by a progressive decrease to pre-chamber levels by day 22 and on the first day of recovery. Tidal volume and fR were not statistically different. During the exposure PetCO2 was significantly elevated with day 2 having the largest increase (19.6%). PetCO2 returned to normal within 24 h post exposure. The HCVR was characterized by the slope (SHCVR), intercept at zero ventilation (B), and the ventilation at a PCO2 = 60 mmHg (VE60). The SHCVR decreased (14%) on day 2, but was not significant; the SHCVR on the other exposure days were also not different. The SHCVR on the first recovery day significantly increased (37%). The HCVR B was shifted to the right on day 2 by 5.2 mmHg, then progressively returned to the pre-exposure position. On recovery the B significantly shifted 6.9 mmHg to the right of pre-exposure B. The VE60 decreased by approximately 32% and 16% on day 2 and 5, respectively, then returned within pre-exposure range for the remainder of the exposure and during recovery. During the early phase and one day after the exposure the HCVR was right shifted. One day after exposure chemoreceptor sensitivity to elevated CO2 was increased but, the B was right shifted resulting in a reduced HCVR below PCO2 of 60 mmHg and a greater HCVR above 60 mmHg.

NASA Discipline Cardiopulmonary↗

Metabolic Heat Regenerated Temperature Swing Adsorption for CO2 and Heat Removal/Rejection in a Martian PLSS

Two of the fundamental problems facing the development of a Portable Life Support System (PLSS) for use on Mars, are (i) heat rejection (because traditional technologies use sublimation of water, which wastes a scarce resource and contaminates the premises), and (ii) rejection of carbon dioxide (CO2) in an environment with a CO2 partial pressure (ppCO2) of 0.4-0.9 kPa. Patent-pending Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed to address both these challenges. The technology utilizes an adsorbent that when cooled with liquid CO2 to near sublimation temperatures (~195K) removes metabolically-produced CO2 in the ventilation loop. Once fully loaded, the adsorbent is then warmed externally by the ventilation loop (~300K), rejecting the captured CO2 to Mars ambient. Two beds are used to provide a continuous cycle of CO2 removal/rejection as well as facilitate heat exchange out of the ventilation loop. Any cryogenic fluid can be used in the application; however, since CO2 is readily available on Mars and can be easily produced and stored on the Martian surface, the solution is rather elegant and less complicated when employing liquid CO2. As some metabolic heat will need to be rejected anyway, finding a practical use for metabolic heat is also an overall benefit to the PLSS. To investigate the feasibility of the technology, a series of experiments were conducted which lead to the selection and partial characterization of an appropriate adsorbent. The Molsiv Adsorbents 13X 8x12 (also known as NaX zeolite) successfully removed CO2 from a simulated ventilation loop at the prescribed temperature swing anticipated during PLSS operating conditions on Mars using a cryogenic fluid. Thermal conductivity of the adsorbent was also measured to eventually aid in a demonstrator design of the technology. These results provide no show stoppers to the development of MTSA technology and allow its development to focus on other design challenges as listed in the conclusions section of this paper.

Iacomini, Christine↗

Development of a Fan for Future Space Suit Applications

NASA's next generation space suit system will place new demands on the fan used to circulate breathing gas through the ventilation loop of the portable life support system. Long duration missions with frequent extravehicular activities (EVAs), the requirement for significant increases in reliability and durability, and a mission profile that imposes strict limits on weight, volume and power create the basis for a set of requirements that demand more performance than is available from existing fan designs. This paper describes the development of a new fan to meet these needs. A centrifugal fan was designed with a normal operating speed of approximately 39,400 rpm to meet the ventilation flow requirements while also meeting the aggressive minimal packaging, weight and power requirements. The prototype fan also operates at 56,000 rpm to satisfy a second operating condition associated with a single fan providing ventilation flow to two spacesuits connected in series. This fan incorporates a novel nonmetallic "can" to keep the oxygen flow separate from the motor electronics, thus eliminating ignition potential. The nonmetallic can enables a small package size and low power consumption. To keep cost and schedule within project bounds a commercial motor controller was used. The fan design has been detailed and implemented using materials and approaches selected to address anticipated mission needs. Test data is presented to show how this fan performs relative to anticipated ventilation requirements for the EVA portable life support system. Additionally, data is presented to show tolerance to anticipated environmental factors such as acoustics, shock, and vibration. Recommendations for forward work to progress the technology readiness level and prepare the fan for the next EVA space suit system are also discussed.

Paul. Heather L.↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies: Preprint

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants’ chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Smart indoor air venting system

A venting system in accordance with the present disclosure includes a ventilation fan and one or more sensors coupled to the ventilation fan. The ventilation fan is positioned to vent air from an indoor environment. The sensors are positioned to monitor conditions in the indoor environment and selectively operate the ventilation fan to condition air in the indoor environment.

Moore, Mike↗

Modeling and mitigating airborne pathogen risk factors in school buses

Computational fluid dynamics (CFD) models were developed to simulate the impact of different ventilation scenarios on airborne exposure risks in a 72-passenger school bus. Here, scenarios and factors that were investigated included a moving vs. stationary bus, impacts of a heating unit within the bus, and impacts of alternative ventilation scenarios with different combinations of openings (e.g., windows, door, emergency hatch). Results of the simulations showed that when the bus was stationary, use of the heater increased receptor concentrations unless there was another opening. When the bus was moving, simulations with at least two sets of openings separated from each other in the forward and aft directions produced a through-flow condition that reduced concentrations via dilution from outside air by a factor of ten or more. A single opening in a moving bus generally increased concentrations throughout the cabin due to increased mixing with minimal ventilation. The cumulative exposure risk (time-averaged concentrations) was found to be inversely correlated to the air exchange rate. Stationary and moving-bus scenarios that yielded above ~20 air changes per hour resulted in the lowest cumulative exposures. Recommendations from this study were implemented in new safety and operating procedures by the Albuquerque Public Schools Transportation Center.

60 APPLIED LIFE SCIENCES↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗