Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “validation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Novel Selectivity-Based Forensic Toxicological Validation of a Paper Spray Mass Spectrometry Method for the Quantitative Determination of Eight Amphetamines in Whole Blood

Paper spray tandem mass spectrometry is used to identify and quantify eight individual amphetamines in whole blood in 1.3 min. The method has been optimized and fully validated according to forensic toxicology guidelines, for the quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-methylamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), para-methoxyamphetamine (PMA), para-methoxymethamphetamine (PMMA), and 4-fluoroamphetamine (4-FA). Additionally, a new concept of intrinsic and application-based selectivity is discussed, featuring increased confidence in the power to discriminate the amphetamines from other chemically similar compounds when applying an ambient mass spectrometric method without chromatographic separation. Accuracy was within ±15% and average precision was better than 15%, and better than 20% at the LLOQ. Detection limits between 15 and 50 ng/mL were obtained using only 12 μL of whole blood. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast permeability measurement for tight reservoir cores using only initial data of the one chamber pressure pulse decay test

Here, in this study, a mathematical model for fast determination of the permeabilities of tight rocks using measurements taken from the initial period of the One Chamber Pressure Pulse Decay (OC-PPD) test is presented. The model applies to measurements taken both before and after the pressure pulse front has reached the downstream end of the specimen. The analytical solutions for the pressure decay in the upstream chamber are derived based on a parabolic arc approximation of pore pressure distribution along the test specimen. This approximation allows converting the initial–boundary value problem of fluid diffusion in the specimen, governed by partial differential equations, to a system of ordinary differential equations that can be easily solved by explicit formulae. Thus, an explicit formula for the pressure decay rate is obtained, which enables inverse analysis of the initial experimental data to estimate the rock permeability. The proposed method expedites the pulse decay test as it does not require the system to reach equilibrium. The method is validated with three sets of experimental data of the OC-PPD test using helium as the diffusing fluid, for which the relative error of the permeability is found to be less than 6%. This method is particularly useful if the equilibrium time of the pulse decay test for rock specimens with permeabilities in the range of nano-Darcy takes hours or days.

early-time solution↗

Effect of Nucleation Heterogeneity on Mineral Precipitation in Confined Environments

Abstract The formation of new mineral phases in confined environments, especially in porous media, is crucial for various geological processes like mineralization and diagenesis. The nucleation and precipitation of minerals are initiated at the microscale through fluid‐rock interaction, where dissolution of primary phases leads to supersaturated conditions and nucleation and growth of secondary ones. Previous research has focused primarily on either precipitation or nucleation, without fully exploring their combined impact. Our study introduces a computational framework that integrates classical nucleation theory with the micro‐continuum method. We validated our model by comparing with experiments, and discovered that different surface nucleation rate changes the mode of precipitation from a preferential to uniform precipitate textures. Furthermore, our study uncovered that the conventional deterministic precipitation method tends to underestimate the permeability of the porous matrix. In contrast, the new framework significantly improves model accuracy by incorporating preferential precipitation and heterogeneous nucleation.

58 GEOSCIENCES↗

Automatic Loss Factor Modeling and Attribution on Unlabeled PV Energy Data

We present a novel approach for modeling the loss factors of photovoltaic power generation systems (PV systems). This method is a white-box machine learning model built on convex optimization that is fast, interpretable, and auditable. It takes as an input the measured daily energy produced by the system, over a multi-year period, and returns a multiplicative decomposition model of the daily energy signal and full attribution of the total energy loss to each feature. The methods section of this paper has two major components: (1) the description of the signal decomposition (SD) model, expressed in the SD framework, and (2) the attribution of total energy losses via Shapley values. We validate the method on synthetic and open-source data sets and compare to similar methods from the literature.

artificial intelligence↗

What Questions Would a Systems Engineer Ask to Assess Systems Engineering Models as Credible

Digital Systems Engineering strategies typically call for digital Systems Engineering models to be retained in repositories and certified as an authoritative source of truth (enabling model reuse, qualification, and collaboration). In order for digital Systems Engineering models to be certified as authoritative (credible), they need to be assessed - verified and validated - and with the amount of uncertainty in the model quantified (consider reusing someone else's model without knowing the author). Due to this increasing model complexity, the authors assert that traditional human-based methods for validating, verifying, and uncertainty quantification - such as human-based peer-review sessions - cannot sufficiently establish that a digital Systems Engineering model of a complex system is credible. Digital Systems Engineering models of complex systems can contain millions of nodes and edges. The authors assert that this level of detail is beyond the ability of any group of humans - even working for weeks at a time - to discern and catch every minor model infraction. In contrast, computers are highly effective at discerning infractions with massive amounts of information. The authors suggest that a better approach might be to focus the humans at what model patterns should be assessed and enable the computer to assess the massive details in accordance with those patterns - by running through perhaps 100,000 test loops. In anticipation of future projects to implement and automate the assessment of models at Sandia National Laboratories, a study was initiated to elicit input from a group of 25 Systems Engineering experts. The authors positioning query began with - 'What questions would a Systems Engineer ask to assess Systems Engineering models for credibility?" This report documents the results of that survey.

42 ENGINEERING↗

Preparing Fermions via Classical Sampling and Linear Combinations of Unitaries

We present an extension of the Evolving density matrices on Qubits (E$ρ$OQ) framework that enables efficient fault-tolerant preparation of fermionic quantum states. The original method circumvents state preparation by stochastic sampling, but faces a sign problem in fermionic systems leading to a large number of circuits necessary. We resolve this by combining classical stochastic sampling with a linear combination of unitaries method that avoids the exponential circuit scaling that plagued naïve implementations. The resulting algorithm requires $\mathcal{O}(M^2)$$R_Z$ rotations for circuit preparation, where $M$ is the number of retained basis states. We validate the method for ground and excited states in the Thirring model, including by computing two-point correlation functions relevant to scattering. In this model for fixed accuracy $\varepsilon$, $M$ is found to scale empirically as $M \propto \frac{1}{mg}\log(1/g)\log(1/m)$.

Gustafson, Erik J. [RIACS, Mtn. View] (ORCID:00000↗

Electron Spin Resonance (ESR) for the study of Reactive Oxygen Species (ROS) on the isolated frog skin (Pelophylax bergeri): A non-invasive method for environmental monitoring

Highlights: • ROS levels in frog skin biopsy were determined by spin-trapping ESR spectroscopy. • Skin of frogs collected in polluted areas contains higher ROS concentration. • ROS levels determined in skin biopsy follow the same trend of those from liver samples. • Immunohistochemical analyses and enzymatic activity tests validate the method. • ROS concentration determined by ESR in biosentinel biopsy is an effective biomarker. Reactive oxygen species (ROS) in biological tissues of elected biosentinels represent an optimal biomarker for eco-monitoring of polluted areas. Electron spin resonance (ESR) is the most definitive method for detecting, quantifying and possibly identifying radicals in complex systems.

54 ENVIRONMENTAL SCIENCES↗

PV Performance Modeling and Stakeholder Engagement (Final Technical Report)

This core capability project’s objective is to increase the value of photovoltaic (PV) performance models by improving their functionality, demonstrating, and quantifying their validity, and offering a wide range of stakeholder engagement opportunities. In FY22-24, we developed new and improved modeling algorithms and functions to represent PV performance more accurately in a variety of environments and conditions. The “Model parameter toolkit” was developed and includes functions to translate between different module temperature models, incidence angle modifier models, and single-diode models. A new modeling capability named “PV Atlas” was also developed leveraging Sandia’s High Performance Computing resources. This capability allows us to investigate several questions and provide climate-specific best practices and geographic data files; all these are hosted on an interactive website on Sandia’s GitHub and can be used for training, system optimization, or to provide best practices for uncertainty reduction. For model validation, we published high-quality PV performance, and weather data; these data are well documented, filtered, and processed for quality and include examples on how to run PV simulations. We also developed well documented, standardized methods for validating PV models and ran independent model validation and 2 blind modeling intercomparisons engaging with 49 organizations from 17 countries. We co-led and contributed to a growing, well documented and maintained suite of open-source functions for PV modeling (i.e., the pvlib-python) and we outreached to the PV modeling stakeholders via the PVPMC workshops and web resources. In addition, this project supported US representation and leadership for the International Energy Agency (IEA) PVPS Task 13; specifically, members of our team led and supported 3 subtasks on: 1) Best practices for the optimization of bifacial photovoltaic tracking, 2) Extreme weather events and their multiple impact on PV power plants: Risks, failure mechanisms and mitigation strategies, and 3) Best practice guidelines for the use of economic and technical Key Performance Indicators (KPIs). This project resulted in the publications of 14 peer reviewed journal papers, 37 conference presentations, 6 SAND reports, 5 public datasets and 6 new webpages on the PVPMC website. It supported the release of 13 pvlib-python versions where 28 enhancements were from this PV Performance Modeling project. We co-organized 5 PVPMC workshops in FY22-24 with the participation of 214 unique institutions and around 700 participants. The PVPMC website was redesigned, and its reliability was improved; it receives over 50,000 visitors/year from 202 unique countries.

14 SOLAR ENERGY↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Fast approximate STEM image simulations from a machine learning model

Abstract Accurate quantum mechanical scanning transmission electron microscopy image simulation methods such as the multislice method require computation times that are too large to use in applications in high-resolution materials imaging that require very large numbers of simulated images. However, higher-speed simulation methods based on linear imaging models, such as the convolution method, are often not accurate enough for use in these applications. We present a method that generates an image from the convolution of an object function and the probe intensity, and then uses a multivariate polynomial fit to a dataset of corresponding multislice and convolution images to correct it. We develop and validate this method using simulated images of Pt and Pt–Mo nanoparticles and find that for these systems, once the polynomial is fit, the method runs about six orders of magnitude faster than parallelized CPU implementations of the multislice method while achieving a 1 − R 2 error of 0.010–0.015 and root-mean-square error/standard deviation of dataset being predicted of about 0.1 when compared to full multislice simulations.

47 OTHER INSTRUMENTATION↗

Real-time image denoising of mixed Poisson–Gaussian noise in fluorescence microscopy images using ImageJ

Fluorescence microscopy imaging speed is fundamentally limited by the measurement signal-to-noise ratio (SNR). To improve image SNR for a given image acquisition rate, computational denoising techniques can be used to suppress noise. However, common techniques to estimate a denoised image from a single frame either are computationally expensive or rely on simple noise statistical models. These models assume Poisson or Gaussian noise statistics, which are not appropriate for many fluorescence microscopy applications that contain quantum shot noise and electronic Johnson–Nyquist noise, therefore a mixture of Poisson and Gaussian noise. In this paper, we show convolutional neural networks (CNNs) trained on mixed Poisson and Gaussian noise images to overcome the limitations of existing image denoising methods. The trained CNN is presented as an open-source ImageJ plugin that performs real-time image denoising (within tens of milliseconds) with superior performance (SNR improvement) compared to conventional fluorescence microscopy denoising methods. The method is validated on external datasets with out-of-distribution noise, contrast, structure, and imaging modalities from the training data and consistently achieves high-performance ( > <#comment/> 8 d B ) denoising in less time than other fluorescence microscopy denoising methods.

47 OTHER INSTRUMENTATION↗

An Analysis of Published DAS Studies for Application to SPE Phase III

Distributed Acoustic Sensing (DAS) is an emerging technology capable of recording the acoustic wavefield at unprecedented spatial resolution. However, this new tool requires significant refinements before it becomes operational for explosion monitoring objectives. Recent studies have shown significant development of array processing with DAS data. In this report we explore three such array processing methods including DAS strain-rate data versus geophone measured ground motion, beamforming for event parameters, and machine learning based denoising. Prior to applying these algorithms to the Source Physics Experiment Phase II and Phase III data, we validate these methods through replication analysis.

47 OTHER INSTRUMENTATION↗

Position-specific carbon isotope analysis of serine by gas chromatography/Orbitrap mass spectrometry, and an application to plant metabolism

Position-specific 13 C/ 12 C ratios within amino acids remain largely unexplored in environmental samples due to methodological limitations. We hypothesized that natural-abundance isotope patterns in serine may serve as a proxy for plant metabolic fluxes including photorespiration. Here we describe an Orbitrap method optimized for the position-specific carbon isotope analysis of serine to test our hypothesis and discuss the generalizability of this method to other amino acids. Position-specific carbon isotope ratios of serine were measured using a Thermo Scientific™ Q Exactive™ GC Orbitrap™. Amino acids were hydrolyzed from Arabidopsis biomass, purified from potential matrix interferences, and derivatized alongside standards. Derivatized serine (N,O-bis(trifluoroacetyl)methyl ester) was isolated using gas chromatography, trapped in a reservoir, and purged into the electron ionization source over tens of minutes, producing fragment ions containing different combinations of atoms from the serine-derivative molecule. The 13 C/ 12 C ratios of fragments with monoisotopic masses of 110.0217, 138.0166, and 165.0037 Da were monitored in the mass analyzer and used to calculate position-specific δ 13 C values relative to a working standard. This methodology constrains position-specific δ 13 C values for nanomole amounts of serine isolated from chemically complex mixtures. The δ 13 C values of fragment ions of serine were characterized with ≤1‰ precisions, leading to propagated standard errors of 0.7–5‰ for each carbon position. Position-specific δ 13 C values differed by up to ca 28 ± 5‰ between serine molecules hydrolyzed from plants grown under contrasting pCO 2 , selected to promote different fluxes through photosynthesis and photorespiration. The method was validated using pure serine standards characterized offline. Here this study presents the first Orbitrap-based measurements of natural-abundance, position-specific carbon isotope variation in an amino acid isolated from a biological matrix. We present a method for the precise characterization of isotope ratios in serine and propose applications probing metabolism in plants. We discuss the potential for extending these approaches to other amino acids, paving the way for novel applications.

59 BASIC BIOLOGICAL SCIENCES↗

Estimation of full-field dynamic strains from digital video measurements of output-only beam structures by video motion processing and modal superposition

Strain is an necessary quantity to characterize local structural behaviors and directly correlates with structural damage initiation and development that is within local regions. Strain measurement at high spatial resolution (density) locations is thus required to characterize local structural behaviors and detect potential local damage. Traditional contact-type strain gauges are mostly discrete point-wise sensors that can only be placed in a limited number of positions. Distributed optical fiber sensing techniques can measure strains at spatially dense measurement points, but their instrumentation is a time- and labor-intensive process associated with the issue of the fragility of fibers. Noncontact optical measurement techniques, such as a family of interferometry techniques using laser beams (e.g., laser Doppler vibrometers), can provide vibration measurement at high density spatial points without the need to install sensors on the structure. Yet, these measurement devices are active sensing methods that are relatively expensive and vulnerable to ambient motion. Photogrammetry is an alternative noncontact optical measurement method using (passive) white-light imaging of digital video cameras that are relatively low-cost, agile, and provides simultaneous measurements at high spatial density locations where every pixel becomes a measurement point. Among others, digital image correlation can achieve full-field deformation measurements and subsequently estimate the full-field strains. However, it is computationally extensive. This research develops a new efficient approach to estimate the full-field (as many measurement points as the pixel number of the video frame on the structure) dynamic strains at high-spatial (pixel)-resolution/density location points from the digital video measurement of output-only vibrating structures. The developed approach is based on phase-based video motion estimation and modal superposition of structural dynamic response. Moreover, the method is augmented by a high-fidelity finite element model, which is updated with the full-field experimental modal parameters “blindly” identified from the video measurement of the output-only structure. Laboratory experiments are conducted to validate the method on a bench-scale cantilever beam structure. Results demonstrate that the full-field dynamic strain estimated by the developed approach from the video measurement of the output-only vibrating beam match very well those directly measured by the strain gauges (at discrete measurement points). Some factors associated with the effectiveness of the method are experimentally studied and discussed.

47 OTHER INSTRUMENTATION↗

Accurately measuring the ionic conductivity of membranes via the direct contact method

Accurately measuring the ionic conductivity of membranes is important both for assessing the performance of new membranes as well as for advancing the fundamental understanding of electric field-driven ion transport in membranes. Yet, despite a considerable number of reports on the topic, there is no standardized method for ionic conductivity measurements. One of the main challenges with ionic conductivity measurements is isolating the membrane resistance from the other resistances in the electrochemical cell. In this study, we present a detailed discussion of factors that affect ionic conductivity measurements with the commonly used direct contact method, in which the membrane contacts the electrodes. Such factors include external resistances due to imperfect contact between the membrane and electrodes, residual impedances due to the sample holder and wiring, and fringe effects. Further, we also present and validate simple methods for isolating the true membrane ionic conductivity in both the through-plane and in-plane orientations. These methods can be implemented with virtually any membrane to obtain accurate and reproducible ionic conductivity values. Finally, we outline recommendations for performing ionic conductivity measurements with the direct contact method and a set of parameters to verify when reporting these results.

36 MATERIALS SCIENCE↗

Fault Clearing Operation in Low-Frequency High-Voltage AC Systems

Abstract—Low-frequency high-voltage ac (LF-HVac) system has been proposed as an alternative to HVdc and HVac systems to reduce transmission losses and improve grid flexibility. LF-HVac system employs back-to-back (BTB) converters to interconnect and control the voltage and power interchange between two power grid operating at different frequencies. While there are multiple studies on LF-HVac system in the literature, the fault clearing method in the LF-HVac system has not been analyzed. Therefore, this paper focuses on fault clearing operation in LFHVac system and proposes a novel method to reduce fault current by changing operating frequency of power source and converter. The performance of the proposed method is validated using detailed models of BTB converters developed in PSCAD/EMTDC. The ability to change operating frequency at the onset of a fault condition allows breakers to rapidly clear the fault and recloses. The results obtained by using the proposed method substantially diminish the fault current.

Kim, Woosung↗

Characterizing and Mitigating Intraday Variability: Reconstructing Source Structure in Accreting Black Holes with mm-VLBI

The extraordinary physical resolution afforded by the Event Horizon Telescope has opened a window onto the astrophysical phenomena unfolding on horizon scales in two known black holes, M87* and Sgr A*. However, with this leap in resolution has come a new set of practical complications. Sgr A* exhibits intraday variability that violates the assumptions underlying Earth aperture synthesis, limiting traditional image reconstruction methods to short timescales and data sets with very sparse (u, v) coverage. We present a new set of tools to detect and mitigate this variability. We develop a data-driven, model-agnostic procedure to detect and characterize the spatial structure of intraday variability. This method is calibrated against a large set of mock data sets, producing an empirical estimator of the spatial power spectrum of the brightness fluctuations. We present a novel Bayesian noise modeling algorithm that simultaneously reconstructs an average image and statistical measure of the fluctuations about it using a parameterized form for the excess variance in the complex visibilities not otherwise explained by the statistical errors. These methods are validated using a variety of simulated data, including general relativistic magnetohydrodynamic simulations appropriate for Sgr A* and M87*. We find that the reconstructed source structure and variability are robust to changes in the underlying image model. We apply these methods to the 2017 EHT observations of M87*, finding evidence for variability across the EHT observing campaign. The variability mitigation strategies presented are widely applicable to very long baseline interferometry observations of variable sources generally, for which they provide a data-informed averaging procedure and natural characterization of inter-epoch image consistency.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-CD-201-03: A Real-Time Method to Simultaneously Measure Linear Energy Transfer and Dose for Proton Therapy Using Organic Scintillators

Purpose: The light generated in organic scintillators depends on both the radiation dose and the linear energy transfer (LET). The LET dependence leads to an under-response of the detector in the Bragg peak of proton beams. This phenomenon, called ionization quenching, must be corrected to obtain accurate dose measurements of proton beams. This work exploits the ionization quenching phenomenon to provide a method of measuring LET and auto correcting quenching. Methods: We exposed simultaneously four different organic scintillators (BCF-12, PMMA, PVT, and LSD; 1mm in diameter) and a plane parallel ionization chamber in passively scattered proton beams to doses between 32 and 43 cGy and fluence averaged LET values from 0.47 to 1.26 keV/µm. The LET values for each irradiation condition were determined using a validated Monte Carlo model of the beam line. We determined the quenching parameter in the Birk’s equation for scintillation in BCF-12 for dose measurements. One set of irradiation conditions was used to correlate the scintillation response ratio to the LET values and plot a scintillation response ratio versus LET calibration curve. Irradiation conditions independent from the calibration ones were used to validate this method. Comparisons to the expected values were made on both the basis of dose and LET. Results: Among all the scintillators investigated, the ratio of PMMA to BCF-12 provided the best correlation to LET values and was used as the LET calibration curve. The expected LET values in the validation set were within 2%±6%, which resulted in dose accuracy of 1.5%±5.8% for the range of LET values investigated in this work. Conclusion: We have demonstrated the feasibility of using the ratio between the light output of two organic scintillators to simultaneously measure LET and dose of therapeutic proton beams. Further studies are needed to verify the response in higher LET values.

60 APPLIED LIFE SCIENCES↗