Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmission deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion↗

Regional Energy Deployment System (ReEDS) Model Documentation: Version 2019

The Regional Energy Deployment System (ReEDS) model is a capacity expansion and dispatch model that is primarily used for the contiguous U.S. electric power sector. The model relies on system-wide least cost optimization to estimate the type and location of future generation and transmission capacity. This document describes details of how the model is formulated, how it functions, and many of the key inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional Energy Deployment System (ReEDS) Model Documentation (Version 2020)

The Regional Energy Deployment System (ReEDS) model is a capacity expansion and dispatch model that is primarily used for the contiguous U.S. electric power sector. The model relies on system-wide least cost optimization to estimate the type and location of future generation and transmission capacity. This document describes details of how the model is formulated, how it functions, and many of the key inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional Energy Deployment System (ReEDS) Model Documentation: 2025

The Regional Energy Deployment System (ReEDS) model is a capacity expansion and dispatch model that is primarily used for the contiguous U.S. electric power sector. The model relies on system-wide least cost optimization to estimate the type and location of future generation and transmission capacity. This document describes details of how the model is formulated, how it functions, and many of the key inputs.

15 GEOTHERMAL ENERGY↗

Revising the Feasibility Study for Solar PV Deployment Conducted for Pueblo of Zia in 2013

The project team comprising ICAST (International Center for Appropriate and Sustainable Technology), a national 501 c3 nonprofit, and Pueblo of Zia worked to determine the feasibility of constructing two different types of solar projects. The first is a 5 MW solar farm on tribal land, adjacent to the Tri-State Generation and Transmission substation, the utility that has exclusive rights to serve the Pueblo of Zia. The second is behind-the-meter solar installations on or near Pueblo of Zia buildings, such as the Zia Enrichment Library, the T'siya Enrichment Center, the Health and Wellness Center, the Tribal Administration Building, and Zia Pueblo Senior Center.

14 SOLAR ENERGY↗

Expanded modelling scenarios to understand the role of offshore wind in decarbonizing the United States

An assessment of decarbonization pathways in energy models reveals fundamental limitations in representing factors that are relevant for practical decision-making. Although these modelling limitations are widely acknowledged, their impact on the deployment of individual power generation types is not well understood. As a result, the societal value from such generation types could be vastly misrepresented. Here we explore a wide spectrum of factors that impact offshore wind deployment in the United States using a detailed capacity expansion model. Many factors prescribe a large future role for offshore wind, yet this diverges from what models often show. We extend the typically narrow modelling context through high spatial resolution, several cost and transmission possibilities and various energy-sector policies. Further, we estimate offshore wind to constitute 1-8% (31-256 gigawatts) of total US generation by 2050. This wide range suggests an uncertain but potentially important regional role. Our expansive scenarios demonstrate how to address many limitations of decarbonization modelling.

17 WIND ENERGY↗

Soot Aerosol Properties in Laminar Soot-Emitting Microgravity Nonpremixed Flames

The spatial distributions and morphological properties of the soot aerosol are examined experimentally in a series of 0-g laminar gas-jet nonpremixed flames. The methodology deploys round jet diffusion flames of nitrogen-diluted acetylene fuel burning in quiescent air at atmospheric pressure. Full-field laser-light extinction is utilized to determine transient soot spatial distributions within the flames. Thermophoretic sampling is employed in conjunction with transmission electron microscopy to define soot microstructure within the soot-emitting 0-g flames. The microgravity tests indicate that the 0-g flames attain a quasi-steady state roughly 0.7 s after ignition, and sustain their annular structure even beyond their luminous flame tip. The measured peak soot volume fractions show a complex dependence on burner exit conditions, and decrease in a nonlinear fashion with decreasing characteristic flow residence times. Fuel preheat by approximately 140 K appears to accelerate the formation of soot near the flame axis via enhanced fuel pyrolysis rates. The increased soot presence caused by the elevated fuel injection temperatures triggers higher flame radiative losses, which may account for the premature suppression of soot growth observed along the annular region of preheated-fuel flames. Electron micrographs of soot aggregates collected in 0-g reveal the presence of soot precursor particles near the symmetry axis at midflame height, The observations also verify that soot primary particle sizes are nearly uniform among aggregates present at the same flame location, but vary considerably with radius at a fixed distance from the burner. The maximum primary size in 0-g is found to be by 40% larger than in 1-g, under the same burner exit conditions. Estimates of the number concentration of primary particles and surface area of soot particulate phase per unit volume of the combustion gases are also made for selected in-flame locations.

Konsur, Bogdan↗

A Science-Focused Artificial Intelligence (AI) Responding in Real-Time to New Information: Capability Demonstration for Ocean World Missions

Introduction: Artificial intelligence (AI) has long been considered a potential mechanism to explore increasingly challenging environments, including those with extreme temperatures and pressures, limited communication capabilities, or those with demanding terrain. We posit that missions in extreme environments could deploy an onboard AI focused on science observations and goals in order to augment a traditional concept(s) of operations (ConOps). An onboard AI capability could perform functions such as data analysis in order to make high-level decisions, including prioritized data transmission for analysis by ground-based teams or autonomously-guided follow-on analyses that maximize science return. Such a capability would empower missions to respond to scientific data of interest in real-time; a mission could make observations and perform a preliminary analysis to alert ground-based scientists to an observation of interest, enabling an informed, rapid response from Earth-based teams. Enceladus Case Study for Onboard AI: We are developing an onboard AI capability for real-time telemetry response that formulates and carries-out informed decisions in service to established mission goals, enabling increased science return of a mission. We focus our AI development for use on a constellation of SmallSats orbiting Enceladus. Our Enceladus case study tests autonomous decision-making capabilities in scenarios with complex orbital dynamics, plume ejecta, extreme cold environments, power restrictions, and a requirement to maximize science return for a potential positive detection of life, while critically evaluating the potential for false positives. Telemetry includes simulated scientific data, spacecraft onboard operational data (e.g., position, velocity, and rotation), and engineering hardware performance data. Enceladus SmallSat Constellation. Our constellation includes eight SmallSat spacecraft in an 8:35 resonant orbit-based formation, leveraging Saturn’s gravitational forces to maintain stable orbits with global coverage around Enceladus. To our knowledge, we simulate the first stable configuration of multiple spacecraft in closed orbits around Enceladus, using a full ephemeris force model (Russell and Lara, 2009). Each spacecraft’s orbit will precess, causing an eastward ground track shift (from an orbiter’s perspective) of each spacecraft for each orbit. However, all spacecraft return to their original positions relative to Enceladus after eight Enceladus revolutions around Saturn. We model communication pathways between SmallSats to understand how information would need to be transmitted across the constellation to enable AI-driven decision-making and resource allocation across the fleet. Capability Demonstration. Our simulated capability demonstration inputs position, velocity, and rotation telemetry from our Enceladus-focused constellation simulations, and mass spectrometry data collected from abiotic and biotic laboratory-analog ocean world experiments (Theiling et al., 2018; Theiling, 2021; Da Poian et al., 2023). Data from these experiments are used to simulate MS measurements and different scenarios of science observations for onboard analysis performed on each of the eight spacecraft. For these demonstrations, we integrate 24 machine learning (ML) algorithms into an onboard intelligence as a ‘knowledge base’, including algorithms evaluating data quality and those predicting (with % confidence) gas composition, ocean aqueous chemistry, and whether the sample was influenced by microbial life. The onboard AI capability is designed to use the knowledge base to come to a consensus-based decision in the interpretation of the observed data in order to request additional action outside of a pre-defined ConOps. Requested actions could include e.g., prioritized downlink to Earth (for analysis by ground-based teams) or follow-on analyses performed across the constellation. The spacecraft’s intelligent onboard planner must then determine whether sufficient resources (e.g., time, power, etc.) are available and weigh the request with mission priorities. In our simulation, the constellation is able to identify potential biosignatures using onboard ML algorithms, evaluate the confidence of that prediction, and perform follow-on analyses across the fleet to confirm the detection, in order to best prepare a transmission of these data to Earth-based teams.

astrobiology↗

Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT)

Module-OT is a bump- in- the- wire solution acting as a secure conduit for data between devices or systems across a network. Using the latest in open-source cryptographic libraries, all defined communications undergo authentication, authorization, and encryption. The core system can be easily installed through industry standard processes, and the use of popular open-source packages allows for it to be customizable customized by the developer community or deployed in unique embedded environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation: Preprint

As the modern power systems are experiencing exceptional changes with increasing penetration of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system would obtain high system resilience, by not relying on the bulk power system restoration requiring significant human intervention and procedure to restore. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and start-up behaviors as well as network dynamics. In addition, active involvement of grid-following distributed energy resources (DER) is also studied to facilitate the black start process. It is shown that, by allowing multiple GFM inverters to collectively black start without master-slave coordination, a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Deploying a Route Optimization EFB Application for Commercial Airline Operational Trials

The Traffic Aware Planner (TAP), developed for NASA Langley Research Center to support the Traffic Aware Strategic Aircrew Requests (TASAR) project, is a flight-efficiency software application developed for an Electronic Flight Bag (EFB). Tested in two flight trials and planned for operational testing by two commercial airlines, TAP is a real-time trajectory optimization application that leverages connectivity with onboard avionics and broadband Internet sources to compute and recommend route modifications to flight crews to improve fuel and time performance. The application utilizes a wide range of data, including Automatic Dependent Surveillance Broadcast (ADS-B) traffic, Flight Management System (FMS) guidance and intent, on-board sensors, published winds and weather, and Special Use Airspace (SUA) schedules. This paper discusses the challenges of developing and deploying TAP to various EFB platforms, our solutions to some of these challenges, and lessons learned, to assist commercial software developers and hardware manufacturers in their efforts to implement and extend TAP functionality in their environments. EFB applications (such as TAP) typically access avionics data via an ARINC 834 Simple Text Avionics Protocol (STAP) server hosted by an Aircraft Interface Device (AID) or other installed hardware. While the protocol is standardized, the data sources, content, and transmission rates can vary from aircraft to aircraft. Additionally, the method of communicating with the AID may vary depending on EFB hardware and/or the availability of onboard networking services, such as Ethernet, WIFI, Bluetooth, or other mechanisms. EFBs with portable and installed components can be implemented using a variety of operating systems, and cockpits are increasingly incorporating tablet-based technologies, further expanding the number of platforms the application may need to support. Supporting multiple EFB platforms, AIDs, avionics datasets, and user interfaces presents a challenge for software developers and the management of their code baselines. Maintaining multiple baselines to support all deployment targets can be extremely cumbersome and expensive. Certification also needs to be considered when developing the application. Regardless of whether the software is itself destined to be certified, data requirements in support of the application and user interface elements may introduce certification requirements for EFB manufacturers and the airlines. The example of TAP, the challenges faced, solutions implemented, and lessons learned will give EFB application and hardware developers insight into future potential requirements in deploying TAP or similar flight-deck EFB applications.

Roscoe, David A.↗

Climate Influences on Capacity Expansion Planning with Application to the Western U.S

Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.

13 HYDRO ENERGY↗

Data and Tools for Exploring New Pumped Storage Hydropower Deployment Opportunities

Pumped storage hydropower (PSH) is a flexible energy storage technology with the potential to facilitate variable renewable energy integration into the decarbonized electric grid of the future. NREL is developing new data and tools to help understand opportunities for new PSH deployment, including nationwide resource assessment data, a bottom-up component-level cost model, and a lifecycle greenhouse gas emissions calculator. These datasets lay the foundation for better-informed grid planning decisions about how PSH fits into a future portfolio of generation, transmission, and storage assets.

CEM↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Understanding Recoverable vs Unrecoverable Voltage Losses and Long-Term Degradation Mechanisms in Anion Exchange Membrane Fuel Cells

Anion exchange membrane fuel cells (AEMFCs) have recently shown excellent progress in terms of their performance – e.g., achievable power and current density. However, very few AEMFCs have been demonstrated with the ability to operate for a long duration (>1000 h). In addition, it is unknown whether performance losses observed during operation are reversible, irreversible, or a combination of the two. In this study, a high-performance AEMFC operated continuously at 600 mA/cm 2 for 3600 h (150 days) at 80 °C with H 2 /O 2 reacting gases was demonstrated. Throughout testing, the electrochemical properties of the AEMFC were probed to provide information about performance degradation pathways and their degree of reversibility. It was found that a portion of the performance loss that occurs during AEMFC operation was due to suboptimal reaction conditions and can be recovered. At the end of the experiment, the cell was disassembled, and its structure and composition were evaluated at the nanoscale by aberration-corrected scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy. The structure and composition of the electrode were compared to cells at the beginning of their operational life. It was found that the primary mechanism for long-term AEMFC performance loss was catalyst agglomeration. During the operational time, there was no evidence of significant polymer degradation, likely due to the high hydration state of the cell. By documenting the long-term changes in high-performing AEMFCs, this work provides important information for the systematic design of cell components and demonstrates the importance of controlling cell operation, which can aid in the commercialization and widespread deployment of low-cost, long-life AEMFCs.

30 DIRECT ENERGY CONVERSION↗

Effective Communication of Energy Science and Technology

Although research, development, and deployment of advanced energy technologies are essential for the clean energy transition, communication about these technologies is equally important to their success. Energy is part of everyday life; therefore, changes in energy systems should be accepted by communities and industries. Yet details about energy generation, transmission, and environmental impacts are complex. The combination of commonality and complexity requires communications to use visualization, localization, narrative, and understandable terminology to reach a range of stakeholders. Collaboration between technology experts and communications professionals builds integrity and accessibility of energy information that enables community-based solutions for energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

How good are learning-based control v.s. model-based control for load shifting? Investigations on a single zone building energy system

Both model predictive control (MPC) and deep reinforcement learning control (DRL) have been presented as a way to approximate the true optimality of a dynamic programming problem, and these two have shown significant operational cost saving potentials for building energy systems. Furthermore, there is still a lack of in-depth quantitative studies on their approximation levels to the true optimality, especially in the building energy domain. To fill in the gap, this paper provides a numerical framework that enables the evaluation of the optimality levels of different controllers for building energy systems. This framework is then used to comprehensively compare the optimal control performance of both MPC and DRL controllers with given computation budgets for a single zone fan coil unit system. Note the optimality is estimated based on a user-specific selection of trade-off weights among energy costs, thermal comfort and control slew rates. Compared with the best optimality we can find through expensive optimization simulations, the best DRL agent can maximally approximate the optimality by 96.54%, which outperforms the best MPC whose optimality level is 90.11%. However, due to the stochasticity, the DRL agent is only expected to approximate the optimality by 90.42%, which is almost equivalent to the best MPC. Except for Proximal Policy Optimization (PPO), all DRL agents can have a better approximation to the optimality than the best MPC, and are expected to have better approximation than the MPC with a prediction horizon of 32 steps (15 min per step). In terms of reducing energy cost and thermal discomfort, MPC can outperform the rule-based control (RBC) by 18.47%–25.44%. DRL can be expected to outperform RBC by 18.95%–25.65% ,and the best DRL control policy can outperform RBC by 20.29%–29.72%. Although the comparison of the optimality level is performed in a perfect setting, e.g., MPC assumes perfect models, and DRL assumes a perfect offline training process and online deployment process, this can shed insight on their capabilities of approximating to the original dynamic programming problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗