Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

High-Performance Computing Based EMT Simulation: Power Grid with IBRs

Electromagnetic transient (EMT) simulation of power grids with high-fidelity models of inverter-based resources (IBRs) is time-consuming and difficult to scale. The necessity for high-fidelity models of IBRs that incorporate the dynamics of individual inverters within IBRs has been showcased in recent studies. These studies focused on events with partial power reduction in each IBR during a transmission line fault in the power grid. These types of events have been documented in multiple North American Electric Reliability Council (NERC) reports in the past decade. It is imperative then to find solutions to speed-up EMT simulations and scale the size of the region with IBRs studied in EMT simulations. In this paper, a combination of numerical simulation algorithms with high-performance computing techniques are employed in discretization and linear solvers employed in the proposed RE-INTEGRATE EMT simulation platform for power grid with IBRs. For ease of scalability, modular and object-oriented programming is used as these techniques are implemented. Additionally, automation software is developed to convert legacy software codes to the proposed RE-INTEGRATE EMT simulation platform. Thereafter, this platform is evaluated on multi-core central processing units (CPUs). Finally, scale-up tests are performed to showcase the scalability that is possible.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Failure analysis of a cooling pump using modal and vibration analysis

Four pumps redundantly supply cooling water to a system. All four pumps underwent maintenance during a recently scheduled downtime. During preliminary evaluation following maintenance, one pump, the subject of this document, exhibited higher vibration levels compared to the other three pumps. The pump underwent further performance testing to rule out potential damage resulting from the higher vibration. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up transients, and modal impact have been utilized to identify dynamic characteristics that could contribute to the increased vibration levels. This article will cover the testing setup, methodology, analysis results, and recommendations.

42 ENGINEERING↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗

Operational resilience metrics for power systems with penetration of renewable resources

Abstract Modern power grid is evolving towards carbon neutrality by deploying increasing amount of renewable energy resources. However, the impact of renewable generation on power system planning and operation is not sufficiently investigated, especially the capability of renewable penetrated power systems to resist and recover from major disturbances, which is a critical concern for system operators. Novel metrics and evaluation methodologies are needed to depict systems’ ability in response to events caused by natural disasters, and quantitatively evaluate system performance in various time scales. In this paper, operational resilience metrics are proposed for power systems with penetration of renewable energy resources based on transient stability principles. A systematic methodology is proposed to quantitatively assess the evolution of system performance during various stages of the disaster process. Based on the proposed metrics, a resilience‐oriented disaster management strategy is designed and validated using the modified IEEE 39‐bus test system. The simulation results demonstrate the validity of the proposed metrics and strategy, and show that the system resilience is enhanced during the mitigation of fault conditions.

Gui, Jianzhong↗

Potential damage to DC superconducting magnets due to the high frequency electromagnetic waves

Experimental data are presented in support of the hypothesis that a dc superconducting magnet coil does not behave strictly as an inductor, but as a complicated electrodynamic device capable of supporting electromagnetic waves. Travel times of nanosecond pulses and evidence of sinusoidal standing waves were observed on a prototype four-layer solenoidal coil at room temperature. Ringing observed during switching transients appears as a sequence of multiple reflected square pulses whose durations are related to the layer lengths. With sinusoidal excitation of the coil, the voltage amplitude between a pair of points on the coil exhibits maxima at those frequencies such that the distance between these points is an odd multiple of half wavelength in free space. Evidence indicates that any disturbance, such as that resulting from switching or sudden fault, initiates multiple reflections between layers, thus raising the possibility for sufficiently high voltages to cause breakdown.

Gabriel, G. J.↗

Transient upset models in computer systems

Essential factors for the design of transient upset monitors for computers are discussed. The upset is a system level event that is software dependent. It can occur in the program flow, the opcode set, the opcode address domain, the read address domain, and the write address domain. Most upsets are in the program flow. It is shown that simple, external monitors functioning transparently relative to the system operations can be built if a detailed accounting is made of the characteristics of the faults that can happen. Sample applications are provided for different states of the Z-80 and 8085 based system.

Mason, G. M.↗

Modeling Distributed Energy Resources for Analyzing Distribution Systems with High Renewable Penetration: Preprint

Increasing levels of inverter-based distributed energy resources (IBDERs) impact the legacy overcurrent distribution protection systems. The fault current injections of IBDERs are limited to between 1-2 p.u. of the rated current. The combination of the limited fault current and varying system load makes it increasingly difficult to reliably set the overcurrent protection. To address this challenge, researchers are proposing adaptive overcurrent protection mechanisms that can adapt to changing system conditions. Accurate modeling of IBDERs is required to develop reliable protection schemes. This paper presents a photovoltaics-based IBDER model in OpenDSS for adaptive overcurrent protection. The paper presents the validation of the proposed IBDER model against a detailed model in electromagnetic transient programs. Protection analysis of the Electric Power Research Institute J1 feeder with the proposed IBDER model is also presented.

adaptive↗

Solar Dynamic Power System Stability Analysis and Control

The objective of this research is to conduct dynamic analysis, control design, and control performance test of solar power system. Solar power system consists of generation system and distribution network system. A bench mark system is used in this research, which includes a generator with excitation system and governor, an ac/dc converter, six DDCU's and forty-eight loads. A detailed model is used for modeling generator. Excitation system is represented by a third order model. DDCU is represented by a seventh order system. The load is modeled by the combination of constant power and constant impedance. Eigen-analysis and eigen-sensitivity analysis are used for system dynamic analysis. The effects of excitation system, governor, ac/dc converter control, and the type of load on system stability are discussed. In order to improve system transient stability, nonlinear ac/dc converter control is introduced. The direct linearization method is used for control design. The dynamic analysis results show that these controls affect system stability in different ways. The parameter coordination of controllers are recommended based on the dynamic analysis. It is concluded from the present studies that system stability is improved by the coordination of control parameters and the nonlinear ac/dc converter control stabilize system oscillation caused by the load change and system fault efficiently.

Momoh, James A.↗

Electrical Systems of Pumped Storage Hydropower Plants: Electrical Generation, Machines, Power Electronics, and Power Systems

Adjustable-speed (AS) pumped storage hydropower (PSH) technology has the potential to become a large, consistent contributor to grid stability enabling higher penetrations of wind and solar energy on the future U.S. power system. AS-PSH has high-value characteristics, such as fast response to provide ancillary services to the grid, because it is a power converter interface with the grid (like battery storage), but at the same time it has the energy content large enough to supply both short-term (seconds-to-minutes) and long-term (minutes-to-hours) of energy needs, like more conventional power plants. However, designs must be optimized to lower the capital expenditure (CapEx) and to provide a high-quality grid interface capability (e.g. power quality, ancillary service provider, fault-tolerant or fault ride-through capability), which is a primary factor in the acceptance of AS-PSH into a utility’s generation mix. This CapEx will be greatly affected by the cost savings associated with the civil structure, turbine design, power electronics, control systems, or unique generator designs. A holistic design must be considered to get a full picture of the benefits of the technology proposed. The AS-PSH can be controlled to reduce the impact of transient disturbance on a power system and at the same time can be controlled to minimized subsequent component fatigue and potential oscillation modes within the plant, with the overall impact in reducing the operational expenditures (OpEx).Generating clean power to meet standards such as Institute of Electrical and Electronics Engineers (IEEE) 519 and International Electrotechnical Commission (IEC) 1000-3-2 will be a continuing challenge. For many technology developers, however, improved AS-PSH technologies will become a key component of generator-storage systems of the future given the prospects of increased performance and decreasing costs, and the ever-increasing penetration of renewables (e.g wind power and solar power).

13 HYDRO ENERGY↗

PASP, a high voltage array/plasma interaction experiment

The author discusses the photovoltaic array space power (PASP) experiment, which is designed to obtain data on the interaction between high-voltage photovoltaic arrays and the polar, low-earth plasma environment. Up to six small test arrays (three each of planar and concentrator designs) can be voltage biased over a range of +/- 500 V. During the bias voltage sequence, the array current leakage is measured and array arc events are monitored. If any arcing occurs the arc characteristics will be measured by a transient pulse monitor. An emitter is included to allow voltage bias to be applied to a plasma-charged or uncharged spacecraft. Similarly, the frames of the concentrator arrays can be left floating or can be tied to the negative array terminal. An environmental data scan is made before each bias voltage sequence. This scan collects information on the plasma, array-current-versus-voltage curves, and neutral particle partial pressure. The requirement for high voltages created problems which were met by circuit isolation and logical fault protection.

Burger, Dale R.↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗

Fundamentals of Digital Engineering: Designing for Reliability

The concept of designing for reliability will be introduced along with a brief overview of reliability, redundancy and traditional methods of fault tolerance is presented, as applied to current logic devices. The fundamentals of advanced circuit design and analysis techniques will be the primary focus. The introduction will cover the definitions of key device parameters and how analysis is used to prove circuit correctness. Basic design techniques such as synchronous vs asynchronous design, metastable state resolution time/arbiter design, and finite state machine structure/implementation will be reviewed. Advanced topics will be explored such as skew-tolerant circuit design, the use of triple-modular redundancy and circuit hazards, device transients and preventative circuit design, lock-up states in finite state machines generated by logic synthesizers, device transient characteristics, radiation mitigation techniques. worst-case analysis, the use of timing analyzer and simulators, and others. Case studies and lessons learned from spaceflight designs will be given as examples

Katz, R.↗

Volcanic arc rigidity variations illuminated by coseismic deformation of the 2011 Tohoku-oki M9

Rock strength has long been linked to lithospheric deformation and seismicity. However, independent constraints on the related elastic heterogeneity are missing, yet could provide key information for solid Earth dynamics. Using coseismic Global Navigation Satellite Systems (GNSS) data for the 2011 M9 Tohoku-oki earthquake in Japan, we apply an inverse method to infer elastic structure and fault slip simultaneously. We find compliant material beneath the volcanic arc and in the mantle wedge within the partial melt generation zone inferred to lie above ~100 km slab depth. We also identify low-rigidity material closer to the trench matching seismicity patterns, likely associated with accretionary wedge structure. Along with traditional seismic and electromagnetic methods, our approach opens up avenues for multiphysics inversions. Those have the potential to advance earthquake and volcano science, and in particular once expanded to InSAR type constraints, may lead to a better understanding of transient lithospheric deformation across scales.

58 GEOSCIENCES↗

A Performance Prediction Model for a Fault-Tolerant Computer During Recovery and Restoration

The modeling and design of a fault-tolerant multiprocessor system is addressed. Of interest is the behavior of the system during recovery and restoration after a fault has occurred. The multiprocessor systems are based on the Algorithm to Architecture Mapping Model (ATAMM) and the fault considered is the death of a processor. The developed model is useful in the determination of performance bounds of the system during recovery and restoration. The performance bounds include time to recover from the fault, time to restore the system, and determination of any permanent delay in the input to output latency after the system has regained steady state. Implementation of an ATAMM based computer was developed for a four-processor generic VHSIC spaceborne computer (GVSC) as the target system. A simulation of the GVSC was also written on the code used in the ATAMM Multicomputer Operating System (AMOS). The simulation is used to verify the new model for tracking the propagation of the delay through the system and predicting the behavior of the transient state of recovery and restoration. The model is shown to accurately predict the transient behavior of an ATAMM based multicomputer during recovery and restoration.

Obando, Rodrigo A.↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

In-field strain and temperature measurements in a (RE)Ba 2 Cu 3 O 7–x coil via Rayleigh-backscattering interrogated optical fibers

(RE)Ba 2 Cu 3 O 7-x (REBCO) conductors have overcome technical challenges related to manufacturing quality, length homogeneity, scale-up of piece-length, and joints. There is one remaining technical challenge, however, which is common to all high temperature superconductors and lies in effective detection of failure to prevent material degradation. An innovative technique based on optical fibers interrogated by Rayleigh backscattering has been shown to have advantages over voltage taps at detecting incipient faults. Prior work has experimentally demonstrated the technique in several implementation scenarios, including direct integration of optical fibers into superconducting conductors and cables to create a class of ‘SMART’ conductors and cables that are able to monitor their own health. In this paper, the magnet monitoring technique based on Rayleigh backscattering interrogated optical fibers has been experimentally studied in a model coil subject to external magnetic field, where different fiber integration methods are used to increase selectivity of the fiber sensor to temperature. Results show that the spectral shift displays different features during strain and thermal transients. The implications of the results in terms of potential and limitations of each sensor as well as strain-temperature decoupling are discussed.

36 MATERIALS SCIENCE↗

A Power-Hardware-in-the-Loop (PHIL) Evaluation of Service Restoration With Networked Microgrids

This paper describes the power-hardware-in-the- loop (PHIL) evaluation of the feasibility of service restoration solutions determined by the PowerModelsONM.jl tool. This tool incorporates microgrids and the networking of microgrids into its determination of an optimal service restoration solution. The paper presents PHIL simulation results for a case study based on a real distribution feeder with multiple microgrids, showcas- ing the effectiveness of networked microgrids in aiding system restoration after an outage. The study leverages high-fidelity, real- time electromagnetic transient models to ensure accuracy in the simulation results. This work is the final output from the Resilient Operation of Networked Microgrids (RONM) project funded by the U.S. Department of Energy Office of Electricity Microgrid Program and led by Los Alamos National Laboratory. RONM focused on the application of PowerModelsONM.jl to enhance the resilience of distribution systems.

fault location isolation and service restoration (↗