Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “traceable calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

REFSafE: A RAG-Enabled Framework for Predictive Risk Analysis and Automated Safety Report Generation in Mission-Critical Environments

Operational safety in mission-critical environments requires AI systems that are accurate, interpretable, and resistant to hallucination. We present an agentic Retrieval-Augmented Generation (RAG) framework, REFSafe, for grounded hazard analysis and automated safety report generation. The system integrates Large Language Models (LLMs) with structured operational data, historical incident repositories, policy documents, and external authoritative sources. Through iterative agentic reasoning, the framework retrieves, verifies, and synthesizes evidence prior to generation, enforcing citation-backed outputs with explicit source attribution (documents, links, and prior events) to ensure traceability and trust. To mitigate hallucinations and unsupported claims, all risk assessments and forecasts are constrained to retrieved evidence, with confidence signals derived from retrieval relevance and source consistency. A transparent pipeline enables subject matter experts (SMEs) to validate predictions, and provide structured feedback, forming a continuous performance calibration loop. Preliminary deployment demonstrates improved reliability in hazard detection and safety/vulnerability report generation. This work advances trustworthy, evidence-grounded AI for predictive safety intelligence in mission-critical operations.

Das, Sanjay [ORNL] (ORCID:0009000542591915)↗

Improving the longest SI traceable hyperspectral infrared record from space from the AIRS

The Atmospheric Infrared Sounder (AIRS) is a “facility” instrument developed by NASA as an experimental demonstration of advanced technology for remote sensing and the benefits of high resolution infrared spectra to weather forecasting and science investigations . It was launched into a 1:30 am/pm polar orbit on May 4, 2002 on the EOS Aqua Spacecraft, and is expected to provide highly calibrated data beyond 2024. AIRS has 2378 infrared channels ranging from 3.7 um to 15.4 um and a 13.5 km footprint. The AIRS data are used for weather forecasting, climate process studies and validating climate models. AIRS is a vital IR reference sensor for GSICS and is used by JMA for comparison to Himawari AHI , KMA for comparison to COMS , NOAA for comparison to CrIS and GOES , and EUMETSAT for comparison to IASI .

Strow, Larrabee↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

Quantitative spectroscopy for the analysis of GOME data

Accurate analysis of the global ozone monitoring experiment (GOME) data to obtain atmospheric constituents requires reliable, traceable spectroscopic parameters for atmospheric absorption and scattering. Results are summarized for research that includes: the re-determination of Rayleigh scattering cross sections and phase functions for the 200 nm to 1000 nm range; the analysis of solar spectra to obtain a high-resolution reference spectrum with excellent absolute vacuum wavelength calibration; Ring effect cross sections and phase functions determined directly from accurate molecular parameters of N2 and O2; O2 A band line intensities and pressure broadening coefficients; and the analysis of absolute accuracies for ultraviolet and visible absorption cross sections of O3 and other trace species measurable by GOME.

Chance, K.↗

Evaluations of University of Wisconsin Silicon Carbide Temperature Monitors 300 LO and 400 LO B

Silicon carbide (SiC) temperature monitors 05R4-02-A KG1403 (300 LO) and 05R4-01-A KG1415 (400 LO B) were evaluated at the High Temperature Test Lab (HTTL) to determine their peak irradiation temperatures. HTTL measurements indicate that the peak irradiation temperature for the 300 LO monitor was 295 {+-} 20 °C and the peak irradiation temperature for the 400 LO B monitor was 294 {+-} 25 °C. Two silicon carbide (SiC) temperature monitors irradiated in the Advanced Test Reactor (ATR) were evaluated at the High Temperature Test Lab (HTTL) to determine their peak temperature during irradiation. These monitors were irradiated as part of the University of Wisconsin Pilot Project with a target dose of 3 dpa. Temperature monitors were fabricated from high density (3.203 g/cm 3 ) SiC manufactured by Rohm Haas with a nominal size of 12.5 mm x 1.0 mm x 0.75 mm (see Attachment A). Table 1 provides identification for each monitor with an expected peak irradiation temperature range based on preliminary thermal analysis (see Attachment B). Post irradiation calculations are planned to reduce uncertainties in these calculated temperatures. Since the early 1960s, SiC has been used as a post-irradiation temperature monitor. As noted in Reference 2, several researchers have observed that neutron irradiation induced lattice expansion of SiC annealed out when the post-irradiation annealing temperature exceeds the peak irradiation temperature. As noted in Reference 3, INL uses resistivity measurements to infer peak irradiation temperature from SiC monitors. Figure 1 depicts the equipment at the HTTL used to evaluate the SiC monitors. The SiC monitors are heated in the annealing furnace using isochronal temperature steps that, depending on customer needs, can range from 50 to 800 °C. This furnace is located under a ventilation hood within the stainless steel enclosure. The ventilation system is activated during heating so that any released vapors are vented through this system. Annealing temperatures are recorded using a National Institute of Standards and Technology (NIST) traceable thermocouple inserted into an alumina tube in the furnace. After each isochronal annealing, the specimens are placed in a specialized fixture located in the constant temperature chamber (maintained at 30 °C) for a minimum of 30 minutes. After the 30 minute wait time, each specimen's resistance is measured using the specialized fixture and a calibrated DC power analyzer. This report discusses the evaluation of the SiC monitors and presents the results. Testing was conducted in accordance with Reference 3. Sections 2 and 3 present the data collected for each monitor and provide interpretation of the data. Section 4 presents the evaluated temperature results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Updates of Moderate Resolution Imaging Spectroradiometer On-Orbit Calibration Uncertainty Assessments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments have successfully operated for more than 18 and 16 years, respectively, on-board the NASA’s Earth Observing System Terra and Aqua spacecraft. Both Terra and Aqua MODIS have significantly contributed to the advance of global Earth remote sensing applications with a broad range of science products that have been continuously produced since the beginning of each mission and freely distributed to users worldwide. MODIS collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB), covering wavelengths from 0.41 to 14.4 μm. Its level 1B (L1B) data products, which provide the input for the MODIS high-level science products, include the top of the atmosphere reflectance factors for the RSB, radiances for both the RSB and TEB, and associated uncertainty indices (UI) at a pixel-by-pixel level. This paper provides a brief review of MODIS L1B calibration algorithms, including a number of improvements made in recent years. It presents an update of sensor calibration uncertainty assessments with a focus on several new contributors resulting from on-orbit changes in sensor characteristics, approaches developed to address these changes, and the impact due to on-orbit changes on the L1B data quality. Also discussed are remaining challenges and potential improvements to be made to continuously maintain sensor calibration and data quality, particularly those related to the quality of MODIS L1B uncertainty.

Spectroradiometer↗

Quality Assessment of Molten Salt Thermochemical Property Data

Recommendations are made to enhance user confidence in property values included in the Molten Salt Thermal Database-Thermochemical Properties (MSTDB-TC). Specifically, it is recommended that all available measured values be included with a transparent assessment of each to arrive at a preferred value for each salt composition in the database. The use of a quality assessment and ranking system is recommended for data and property values compiled in the MSTDB-TC that is analogous to the approach developed for data and property values included in the MSTDB-Thermophysical Properties (TP) database. The approach includes assessments of five features of data collection: the method used to measure the property value, calibration of devices used to make the measurements, the quantified uncertainty of the results, control of the environmental conditions, and determination of the salt composition. The quality of each facet is ranked as High, Moderate, or Incomplete based on objective metrics. The overall quality of the dataset is ranked based on rankings of the five data features and traceability of the reported property value, with rankings of A and B indicating the data and property value are deemed suitable for quantitative use, C indicating the value is computed and not validated and U indicating uncertainties restrict the recommended use to qualitative purposes. Sufficient information should be provided or cited within each data set included in the database to verify the reported property value. The recommended approach is suitable for assessing data already in the MSTDB-TC and screening new entries.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Method to Estimate Uncertainty in Radiometric Measurement Using the Guide to the Expression of Uncertainty in Measurement (GUM) Method; NREL (National Renewable Energy Laboratory)

Radiometric data with known and traceable uncertainty is essential for climate change studies to better understand cloud radiation interactions and the earth radiation budget. Further, adopting a known and traceable method of estimating uncertainty with respect to SI ensures that the uncertainty quoted for radiometric measurements can be compared based on documented methods of derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM). derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design techniques for developing a computerized instrumentation test plan

The development of a computerized instrumentation test plan (ITP) for the NASA/Ames Research Center National Full Scale Aerodynamics Complex (NFAC) is discussed. The objective of the ITP program was to aid the instrumentation engineer in documenting the configuration and calibration of data acquisition systems for a given test at any of four low speed wind tunnel facilities (Outdoor Aerodynamic Research Facility, 7 x 10, 40 x 80, and 80 x 120) at the NFAC. It is noted that automation of the ITP has decreased errors, engineering hours, and setup time while adding a higher level of consistency and traceability.

Burnett, S. Kay↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 26-October 7, 2022

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 26 to October 7, 2022. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS varied from -0.80 W/m2 to 0.29 W/m2 and standard deviation (sd) from 0.98 W/m2 to 1.78 W/m2. The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 2.07 to 5.03 W/m2 with sd from 2.64 W/m2 to 2.67 W/m2.

14 SOLAR ENERGY↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 25-October 6, 2023

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 25 to October 6, 2023. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS9 varied from -0.75 W/m 2 to 0.76 W/m 2 , standard deviation (sd) from 0.78 W/m 2 to 1.04 W/m 2 , and uncertainty U95 from 1.96 W/m 2 to 2.07 W/m 2 . The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 1.64 to 3.96 W/m 2 , sd from 1.70 W/m 2 to 1.86 W/m 2 , and uncertainty U 95 from 3.78 W/m 2 to 5.42W/m 2 . Note that from September 25th at 18:31 to September 29 th at 5:30 ACP96F3 irradiance is calculated using Bruce, et al 2023 method.

47 OTHER INSTRUMENTATION↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 23-October 4, 2024

The comparison of the absolute cavity pyrgeometers (ACPs) with the CG4 FT005 pyrgeometer traceable to the InfraRed Integrating Sphere (IRIS) referred to by FT005(IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 23 to October 4, 2024. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. Two methods described in and were used for the comparison based on original Reda et. al and proposed Forgan et. al.

47 OTHER INSTRUMENTATION↗

Dosimetric Characteristics for Brachytherapy Sources

Brachytherapy sources are characterized by the dosimetric parameters in a protocol such as the American Association of Physicists in Medicine Task Group 43. The air-kerma strength is measured and traceable to a primary standard. Then the parameters such as dose-rate constant, radial dose function, and anisotropy function are measured and related back to the primary standard. This is normally accomplished with thermoluminescent dosimeters (TLDs). Since radial dose function and anisotropy function are relative parameters, some of the dosimetric corrections are negligible. For the dose-rate constant, parameters such as the energy dependence compared with a calibration beam such as {sup 60}Co need to be accounted for. A description of the primary standard measurements and TLD measurements will be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Reference Ocean Surface Emission and Backscatter Model from Microwaves to Infrared

Satellite observations are vital for the initialization of Numerical Weather Prediction models, and very important for climate monitoring and prediction, as well as other applications such as hydrology and flood awareness prediction. Knowledge of radiative contributions from the Earth's surface is needed to sound the lower troposphere from space. The lack of a reference quality ocean emission and backscatter model is a major gap in our ability to provide absolute calibration of the satellite based observing system. Uncertainty in emissivity models is not well characterized and different models are used for different spectral bands, for active and passive instruments. An International Space Science Institute (ISSI) team was put together [4] to address these issues. The objectives of the team are to provide a reference model as a community software (i.e., documented and freely available code), that is maintained and supported, has traceable uncertainty estimations, and that enables new science from microwaves to infrared with bidirectional reflectance distribution function (BRDF) capability. We will present the model and its various components, discussing the choices between various parameterizations, building on the LOCEAN model of [2]. The model predictions will be evaluated at various frequencies, including comparisons to radiometric observations by SMAP, AMSR2 and GMI (e.g., [5]). We will discuss early model evaluation in the infrared and for active microwave sensors. Areas of ongoing research include improving the foam parametrization (coverage and emissivity) to provide consistent performances across frequencies, building on [1], and the azimuthal dependence of the active and passive signals. The model will be used to generate training data for fast models e.g., Fastem, [3], that are used in operational data assimilation and climate re-analysis.

Emmanuel Dinnat↗

Vector Calibration for Vertical Tests of Superconducting RF Cavities

We propose procedure for vector calibration of Q 0 vs E acc curve measurement for superconducting resonators. The proposed vector calibration procedure and hardware has several advantages over the techniques currently used for vertical cavity tests. It provides high level of automation and reduces manpower and preparation time for the test; it provides in situ, real time control of hardware parameters and allows to detect hardware failure and operator's errors; it allows to control and exclude the most significant systematic uncertainties, measured values of Q 0 (E acc ) can be made traceable to national standards.

43 PARTICLE ACCELERATORS↗

Invited Article: Expanded and improved traceability of vibration measurements by laser interferometry

Traceability to the International System of Units has been established for vibration and shock measurements as specified in international document standards, recommendations, and regulations to ensure product quality, health, and safety. New and upgraded laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods in the ISO 16063 series of international document standards. In ISO 16063-11:1999, three interferometric methods are specified for the primary calibration of vibration transducers (reference standard accelerometers) in a frequency range from 1 Hz to 10 kHz. In order to specify the same (modified) methods for the calibration of laser vibrometers (ISO 16063-41:2011), their applicability in an expanded frequency range was investigated. Steady-state sinusoidal vibrations were generated by piezoelectric actuators at specific frequencies up to 347 kHz (acceleration amplitudes up to 376 km/s{sup 2}). The displacement amplitude, adjusted by the special interferometric method of coincidence to 158.2 nm (quarter the wavelength of the He-Ne laser light), was measured by the standardized interferometric methods of fringe counting and sine-approximation. The deviations between the measurement results of the three interferometric methods applied simultaneously were smaller than 1 %. The limits of measurement uncertainty specified in ISO 16063-11 between 1 Hz to 10 kHz were kept up to frequencies, which are orders of magnitude greater; the uncertainty limit 0.5 % specified at the reference frequency 160 Hz was not exceeded at 160 kHz. The reported results were considered during the development of ISO 16063-41 by specifying the instrumentation and procedures for performing calibrations of rectilinear laser vibrometers in the frequency range typically between 0.4 Hz and 50 kHz—the interferometric methods may be applied within expanded frequency ranges using refined techniques and procedures. It is concluded that calibration frequencies up to 0.5 MHz are attainable in compliance with the first international document standard for the calibration of laser vibrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements to the operational efficiency of the Portsmouth 'Blue Box' Assay system - 15162

The 'Blue Box' in Building 326 at Portsmouth comprises a dual cargo container lined with high density polyethylene with 5% (elemental) boron that acts as a neutron shield. This construction provides a low environmental neutron background to support the capability to attain low values of minimal detectable activity (MDA). A Non-destructive Assay (NDA) measurement platform known as the Fluor B and W Portsmouth Slab Counter (FBPSC) is housed inside the Blue Box. This comprises four neutron slab detectors supported with an electronic system supplying power and associated signal processing. The system is operated by a laptop computer which has data acquisition and analysis capabilities. Each slab contains five {sup 3}He proportional counters embedded in polyethylene. The system is designed to measure the mass of U-235 in coolers from the Portsmouth site using passive neutron counting. The system was calibrated by taking measurements with {sup 252}Cf sources attached to various positions on the outside surfaces of a surrogate cooler. In addition, Monte-Carlo N-Particle (MCNP) simulations were performed to extend the baseline calibration for coolers of various sizes used in the gaseous-diffusion process. The basic principle of operation is to measure the total neutron emission from the item and determine the mass of {sup 235}U using the system efficiency (determined from MCNP calculations combined with the calibration measurements) combined with known isotopic information ({sup 235}U enrichment and U-235/U-234 ratio), assumed chemical composition, and gross cooler mass. The FBPSC analysis program calculates the mass of U-235 within the cooler being assayed, together with the associated Total Measurement Uncertainty (TMU). A background correction is performed that accounts for the measured environmental background with a cosmic-ray spallation correction (based on the cooler's gross weight). The software suite developed for the system also includes the capability to track and trend measurement control data in order to quickly identify conditions where the system has drifted outside of its quality control envelope. The MDA of the system has been determined to be less the 15 g of U-235 for count times that are typically less than 5 minutes (depending on the uranium isotopics). This is primarily the result of the low neutron background rate inside the Blue Box (approximately 3 times lower than at nearby locations outside the box). Additionally, various software features have been designed to yield optimum counting performance for the system including count time adjustment and interval filtering to reject statistical outliers that are usually associated with cosmic spallation events. The operation of the system has proven to be very efficient, with the short measurement time providing a high throughput rate of coolers through the Blue Box NDA system. Significant operational benefits and improved data traceability have been yielded compared to the previous measurement process, which involved operators taking measurement with counter/scalers and manually entering data into spreadsheets. As of August 2014, this system successfully measured all coolers required to support completion of a contractually-required Performance Milestone. There are approximately 1900 coolers available for measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

California coast nearshore processes study

The author has identified the following significant results. Large scale sediment plumes from intermittent streams and rivers form detectable seasonal patterns on ERTS-1 imagery. The ocean current systems, as plotted from three California coast ERTS mosaics, were identified. Offshore patterns of sediment in areas such as the Santa Barbara Channel are traceable. These patterns extend offshore to heretofore unanticipated ranges as shown on the ERTS-1 imagery. Flying spot scanner enhancements of NASA tapes resulted in details of subtle and often invisible (to the eye) nearshore features. The suspended sediments off San Francisco and in Monterey Bay are emphasized in detail. These are areas of extremely changeable offshore sediment transport patterns. Computer generated contouring of radiance levels resulted in maps that can be used in determining surface and nearsurface suspended sediment distribution. Tentative calibrations of ERTS-1 spectral brightness against sediment load have been made using shipboard measurements. Information from the combined enhancement and interpretation techniques is applicable to operational coastal engineering programs.

Pirie, D. M.↗