Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

320 records · Page 18

The 3-Dimensional Inner and Outer Structure of Ejecta Around Eta Carinae as Detected by the STIS

The HST/STIS instrument was used successfully to perform a complete mapping of the Homunculus nebula at two wavelength ranges including H-alpha and H-beta with a spectral resolving power of about 5000 and a spatial resolution of 0.1". The individual spectra were merged to synthesize three-dimensional data cubes that contain a set of images of Eta Car with spatial resolution of 0.10 to 0.251, sliced at velocity increment of 10 -- 30 km/s. For the first time this unique method allows us to diagnose the origin of intrinsic narrow emission structure of the nebula with high spatial and velocity resolution. Our initial analysis revealed the inner emission structure appeared to trace an elongated bipolar shell (possibly other shells as well) with a scale size of an arcsecond (i.e., "little homunculus in the Homunculus"). Furthermore, the mapping data cube revealed that the "fan" or "paddle" -- often referred as the source of peculiar blue-shifted intrinsic emissions including the Strontium cloud -- is not the source of intrinsic emissions. The fan is not even a part of the equatorial disk, but is spatially separated from the peculiar emission structure. Indeed we suggest that the fan is a surface of the Northwest lobe, possibly revealed by a blowout of the equatorial disk. We will use a number of visualization techniques (tomographic animations and simple 3-D models) to show these structures. These new results have strong impact upon future numerical modelings of the Homunculus nebula and of understanding of the evolution of the ejecta powered by the central source(s).

Ishibashi, Kazunori↗

Accelerated radiation transport modeling techniques for pencil beam computed tomography using gamma rays

Monte Carlo radiation transport modeling studies were performed for a compact, and high-resolution gamma-ray computed tomography system designed for imaging irradiated nuclear fuel. The system comprises a 60 Co source – chosen for its highly penetrating 1173 keV and 1332 keV gamma rays – a pair of high-aspect-ratio pencil beam collimators, and an inorganic scintillator detector. Here two acceleration methods are proposed to rapidly model a transmission type gamma-ray tomography system. The first, a variance reduction technique, is based on performing Monte Carlo simulations with a monodirectionally-biased source, sampled from a characteristic sub-volume of the full source volume. The second acceleration method is based on the deterministic calculations using the Beer–Lambert law and detector response characteristics. Comparison of simulations using acceleration approaches with analog simulations of the fully isotropic, full-volume equivalent, show that the Monte Carlo variance reduction technique gives quantitatively accurate predictions for large collimator aspect ratios while the deterministic calculations are semi-quantitative but converge close to the correct result as the collimator aspect ratio increases. As such, these techniques can be used to reduce the computational cost in generating simulated radiographs and tomographs by several orders of magnitude. Experimental validation efforts are currently underway and will be demonstrated in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

A Fast Hybrid (3-D/1-D) Model for Thermal Radiative Transfer in Cirrus via Successive Orders of Scattering

We investigate the impact of cirrus cloud heterogeneity on the direct emission by cloud or surface and on the scattering by ice particles in the thermal infrared (TIR). Realistic 3-D cirri are modeled with the 3DCLOUD code, and top-of-atmosphere radiances are simulated by the 3-D Monte Carlo radiative transfer (RT) algorithm 3DMCPOL for two (8.65 micrometers and 12.05 micrometers) channels of the Imaging Infrared Radiometer on CALIPSO. At nadir, comparisons of 1-D and 3-D RT show that 3-D radiances are larger than their 1-D counterparts for direct emission but smaller for scattered radiation. For our cirrus cases, 99% of the 3-D total radiance is computed by the third scattering order, which corresponds to 90% of the total computational effort, but larger optical thicknesses need more scattering orders. To radically accelerate the 3-D RT computations (using only few percent of 3-D RT time with a Monte Carlo code), even in the presence of large optical depths, we develop a hybrid model based on exact 3-D direct emission, the first scattering order from 1-D in each homogenized column, and an empirical adjustment linearly dependent on the optical thickness to account for higher scattering orders. Good agreement is found between the hybrid model and the exact 3-D radiances for two very different cirrus models without changing the empirical parameters. We anticipate that a future deterministic implementation of the hybrid model will be fast enough to process multiangle thermal imagery in a practical tomographic reconstruction of 3-D cirrus fields.

radiative transfer↗

Three-Dimensional Morphological Analysis of ALH84001 Magnetite Using Electron Tomography

We report here the crystal morphologies of MV-1 and ALH84001 magnetites as calculated by back-projection using electron tomography. In the present study, we used a 300 keV TEM with a field emission gun (Tecnai F-30 from FEI Inc.), equipped with a 2048 x 2048 pixel CCD camera from Gatan Inc. to image magnetite crystals over tilt ranges of approx. +/- 72 deg in 2 deg tilt intervals. The images were aligned for back-projection, either manually, or through the use of fiducial 5 nm Au spheres affixed to the specimen prior to microscopy. Three-dimensional (3-D) reconstructions were computed using weighted back-projection of the tilted views. The tomograms were viewed and analyzed as a series of slices 1.0 nm thick, taken parallel to the specimen-supporting grid, using the IMOD software package. The shape of each magnetite crystal was determined by defining the external contour of a given magnetite in each slice and assembling a stack of these contours in 3-D. To aid in visualization, the stacked contour array was reduced to an optimal mesh by Delaunay triangulation. The surface normal to each of the triangles in the mesh was calculated and the triangle faces colored according to the orientation of that surface normal relative to the principal crystallographic axis of magnetite. Green surfaces correspond to {111} orientations, blue surfaces to {100} orientations, and red surfaces to {110} orientations. Triangles whose surface normal did not correspond to one of the principal axes were colored gray. Within the experimental and numerical uncertainties of the deconvolution, the tomographic reconstruction of both MV-1 and ALH84001 magnetites are equivalent and correspond to a truncated hexa-octahedral morphology.

Thomas-Keprta, Kathie L.↗

Bubble Mapping with the Square Kilometre Array - I. Detecting Galaxies with Euclid, JWST, WFIRST, and ELT within Ionized Bubbles in the Intergalactic medium at z > 6

The Square Kilometre Array (SKA) is expected to provide the first tomographic observations of the neutral intergalactic medium at redshifts z > 6 and pinpoint the locations of individual ionized bubbles during early stages of cosmic reionization. In scenarios where star-forming galaxies provide most of the ionizing photons required for cosmic reionization, one expects the first ionized bubbles to be centred on overdensities of such galaxies. Here, we model the properties of galaxy populations within isolated, ionized bubbles that SKA-1 should be able to resolve at z ≈ 7–10, and explore the prospects for galaxy counts within such structures with various upcoming near-infrared telescopes. We find that, for the bubbles that are within reach of SKA-1 tomography, the bubble volume is closely tied to the number of ionizing photons that have escaped from the galaxies within. In the case of galaxy-dominated reionization, galaxies are expected to turn up above the spectroscopic detection threshold of JWST and ELT in even the smallest resolvable bubbles at z ≤ 10. The prospects of detecting galaxies within these structures in purely photometric surveys with Euclid, WFIRST, JWST, or ELT are also discussed. While spectroscopy is preferable towards the end of reionization to provide a robust sample of bubble members, multiband imaging may be a competitive option for bubbles at z ≈ 10, due to the very small number of line-of-sight interlopers expected at these redshifts.

Erik Zackrisson↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Heterogeneous mantle effects on the behavior of SmKS waves and outermost core imaging

Seismic traveltime anomalies of waves that traverse the uppermost 100–200 km of the outer core have been interpreted as evidence of reduced seismic velocities (relative to radial reference models) just below the core–mantle boundary (CMB). These studies typically investigate differential traveltimes of SmKS waves, which propagate as P waves through the shallowest outer core and reflect from the underside of the CMB m times. The use of SmKS and S(m-1)KS differential traveltimes for core imaging are often assumed to suppress contributions from earthquake location errors and unknown and unmodelled seismic velocity heterogeneity in the mantle. The goal of this study is to understand the extent to which differential SmKS traveltimes are, in fact, affected by anomalous mantle structure, potentially including both velocity heterogeneity and anisotropy. Velocity variations affect not only a wave's traveltime, but also the path of a wave, which can be observed in deviations of the wave's incoming direction. Since radial velocity variations in the outer core will only minimally affect the wave path, in contrast to other potential effects, measuring the incoming direction of SmKS waves provides an additional diagnostic as to the origin of traveltime anomalies. Here we use arrays of seismometers to measure traveltime and direction anomalies of SmKS waves that sample the uppermost outer core. We form subarrays of EarthScope's regional Transportable Array stations, thus measuring local variations in traveltime and direction. We observe systematic lateral variations in both traveltime and incoming wave direction, which cannot be explained by changes to the radial seismic velocity profile of the outer core. Moreover, we find a correlation between incoming wave direction and traveltime anomaly, suggesting that observed traveltime anomalies may be caused, at least in part, by changes to the wave path and not solely by perturbations in outer core velocity. Modelling of 1-D ray and 3-D wave propagation in global 3-D tomographic models of mantle velocity anomalies match the trend of the observed traveltime anomalies. Overall, we demonstrate that observed SmKS traveltime anomalies may have a significant contribution from 3-D mantle structure, and not solely from outer core structure.

58 GEOSCIENCES↗

Heterogeneous mantle effects on the behavior of SmKS waves and outermost core imaging

Seismic traveltime anomalies of waves that traverse the uppermost 100–200 km of the outer core have been interpreted as evidence of reduced seismic velocities (relative to radial reference models) just below the core–mantle boundary (CMB). These studies typically investigate differential traveltimes of SmKS waves, which propagate as P waves through the shallowest outer core and reflect from the underside of the CMB m times. The use of SmKS and S(m- 1)KS differential traveltimes for core imaging are often assumed to suppress contributions from earthquake location errors and unknown and unmodelled seismic velocity heterogeneity in the mantle. The goal of this study is to understand the extent to which differential SmKS traveltimes are, in fact, affected by anomalous mantle structure, potentially including both velocity heterogeneity and anisotropy. Velocity variations affect not only a wave’s traveltime, but also the path of a wave, which can be observed in deviations of the wave’s incoming direction. Since radial velocity variations in the outer core will only minimally affect the wave path, in contrast to other potential effects, measuring the incoming direction of SmKS waves provides an additional diagnostic as to the origin of traveltime anomalies. Here we use arrays of seismometers to measure traveltime and direction anomalies of SmKS waves that sample the uppermost outer core. We form subarrays of EarthScope’s regional Transportable Array stations, thus measuring local variations in traveltime and direction. We observe systematic lateral variations in both traveltime and incoming wave direction, which cannot be explained by changes to the radial seismic velocity profile of the outer core. Moreover, we find a correlation between incoming wave direction and traveltime anomaly, suggesting that observed traveltime anomalies may be caused, at least in part, by changes to the wave path and not solely by perturbations in outer core velocity. Modelling of 1-D ray and 3-D wave propagation in global 3-D tomographic models of mantle velocity anomalies match the trend of the observed traveltime anomalies. Overall, we demonstrate that observed SmKS traveltime anomalies may have a significant contribution from 3-D mantle structure, and not solely from outer core structure.

58 GEOSCIENCES↗

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

Coronal Reconstruction using LASCO and UVCS Observations

The main goal of the research described in the original proposal was to develop methods to quantify coronal and inner-heliospheric velocity fields of the 'quiet' solar wind. For this we planned to use several sources of observations:(1) SOHO/UVCS velocity information in the range 1.5-3 Solar Radii obtained from Doppler dimming observations; (2) projected solar wind velocities (into the plane of the sky) obtained from SOHO/ LASCO images (1.1-30 Solar Radii), primarily derived from two-dimensional correlation tracking techniques; (3) Interplanetary scintillation observations of the heliospheric (> 26 Solar Radii) solar wind velocity from the Solar-Terrestrial Environment Laboratory (STELab) in Nagoya, Japan; (4) Ecliptic in situ observations: data for the ecliptic solar wind are available from the MIT and Los Alamos plasma experiments on the Earth-orbiting IMP-8 spacecraft, from the Cellas instrument on SOHO near the LI Lagrange point, and from the WIND spacecraft; (5) Out-of-ecliptic in situ observations: these data are available primarily from the Los Alamos SWOOPS instrument on Ulysses, which passed over the solar north pole in August 1995, about one year prior to the Whole Sun Month period. Where ever possible we planned to use the first Whole Sun Month as the main time period for the analysis, since we expected that for this period it would be easiest to obtain adequate coverage over the extended period of time required to analyze 'quiet' solar wind patterns. Beyond the observations mentioned above (primarily SOHO data) we extended our selection of data to several events identified in the Yohkoh/SXT data base which directly promised to provide us with clues about the connection between the slow solar wind observed by IPS in the inner heliosphere and their sources in the low corona, in particular active regions. We also obtained valuable results using SWOOPS ill situ observations from the pole-to-pole passage of Ulysses in a comparison with solar wind velocities derived from a tomographic reconstruction of Nagoya IPS observations.

Hick, P. P.↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Investigation of Sooting in Microgravity Droplet Combustion: Fuel-Dependent Effects

Kumagai and coworkers first performed microgravity droplet combustion experiments [Kumagai, 1957]. The primary goal of these early experiments were to validate simple 'd(sup 2)-law models [Spalding, 1954, Godsave, 1954] Inherent in the 'd(sup 2) -law' formulation and in the scope of the experimental observation is the neglect of sooting behavior. In fact, the influence of sooting has not received much attention until more recent works [Choi et al., 1990; Jackson et al., 1991; Jackson and Avedisian, 1994; Choi and Lee, 1996; Jackson and Avedisian, 1996; Lee et al., 1998]:. Choi and Lee measured soot volume fraction for microgravity droplet flames using full-field light extinction and subsequent tomographic inversion [Choi and Lee, 1996]. In this investigation, soot concentrations were measured for heptane droplets and it was reported that soot concentrations were considerably higher in microgravity compared to the normal gravity flame. It was reasoned that the absence of buoyancy and the effects of thermophoresis resulted in the higher soot concentrations. Lee et al. [1998] performed soot measurement experiments by varying the initial droplet diameter and found marked influence of sooting on the droplet burning behavior. There is growing sentiment that sooting in droplet combustion must no longer be neglected and that "perhaps one of the most important outstanding contributions of (micro)g droplet combustion is the observation that in the absence of asymmetrical forced and natural convection, a soot shell is formed between the droplet surface and the flame, exerting an influence on the droplet combustion response far greater than previously recognized." [Law and Faeth, 1994]. One of the methods that we are exploring to control the degree of sooting in microgravity is to use different fuels. The effect of fuel structure on sooting propensity has been investigated for over-ventilated concentric coflowing buoyant diffusion flames. (Glassman, 1996]. In these investigations, the fuel flowrate was increased until smoke was observed to escape from the "luminous visible flame" [Glassman, 1996]. A total of 29 fuels were used in order to characterize relative sooting propensity. The sooting propensity of a particular fuel was assessed by comparing the flowrates for soot emission from the tip of the flame. It was reported that the sooting tendency for diffusion flames increased for fuels with higher rates of pyrolysis. Randolph and Law [1986 and not 1994] also examined the effect of fuel structure on droplet sooting behavior. In their experiments the droplets were separated from the bulk gas stream and quenched with nitrogen prior to gravimetric measurements. A variety of fuels were studied, namely aromatics, phenyl-alkanes and alkanes. The results were in qualitative agreement with the work of Glassman [1986]. Vander Wal et al. [1994] performed relative soot concentration measurements using laser-induced incandescence for heptane and decane fuel droplets burning under normal-gravity conditions. It was found that soot volume fractions for decane was more than a factor of two larger than that for heptane. Although the normal-gravity investigations have provided some important insights regarding the influence of fuel structure on the sooting behavior of droplet flames, results cannot be easily extrapolated for microgravity studies since increased residence times and thermophoretic effects must be considered in greater detail. Several studies have compared sooting behavior of different fuel droplets burning under microgravity conditions [Card and Choi, 1990; Jackson et al., 1991; Jackson and Avedisian, 1994], however, detailed quantitative results were not provided. In all of these previous studies, the degree of sooting was only visually assessed from an incandescent backlighted image of the soot containing region. Such techniques can provide misleading results regarding sooting behavior [Choi, 1996].

Manzello, Samuel L.↗