Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The performance and calibration of WFPC2 on the Huble Space Telescope

The Wide Field Planetary Camera 2 (WFPC2) was installed in the Hubble Space Telescope (HST) in 1993 December. Since then, the instrument has been providing high-quality images. A significant among of calibration data has been collected to aid in the understanding of the on-orbit performance of the instrument. Generally, the behavior of the camera is similar to its performance during the system-level thermal vacuum test at JPL in 1993 May. Surprises were a significant charge-transfer-efficiency (CTE) problem and a significant growth rate in hot pixels at the original operating temperature of the CCDs (-76 deg C). The operating temperature of the WFPC2 CCDs was changed to -88 deg C on 1994 April 23, and significant improvements in CTE and hot pixels are seen at this temperature. In this paper we describe the on-orbit performance of the WFPC2. We discuss the optical and thermal history, the instrument throughput and stability, the Point Spread Function (PSF), the effects of undersampling on photometry, the properties of cosmic rays observed on-orbit, and the geometric distortion in the camera. We present the best techniques for the reduction of WFPC2 data, and describe the construction of calibration products including superbiases, superdarks, and flat fields.

Holtzman, Jon↗

Simplified thermal analyzer

Simplified Shuttle Payload Thermal Analyzer (SSPTA) aids in evaluating thermal design of instruments to be flown in Space Shuttle cargo bay. It is collection of programs that are currently used in thermal analysis of spacecraft, modified for quick, preliminary analysis of payloads. Although designed primarily to analyze Shuttle payloads, it can be easily used for thermal analysis in other situations.

Coyle, M. J.↗

Analytical Determination of Radioactive Strontium and Cesium by Thermal Ionization Mass Spectrometry

Thermal ionization mass spectrometry (TIMS) has been evaluated for the detection of the radioactive isotopes of strontium and cesium. The instrument was investigated for the analysis of isotopic ratios of 89Sr to 90Sr and 135Cs to 137Cs in the presence of atomic isobars (Y and Zr for Sr analysis and Ba for Cs analysis). Signicant discrimination using TIMS was found for both Sr and Cs through evaluation using stable isotopes. Fusion procedures with different flux were evaluated for preparation of sample matrices. Chemical separations were developed and used after fusion to isolate the Sr and Cs from a prepared background matrix (i.e., Montana Soil). A graded approach, increasing in stable background isotopes, was performed to monitor the chemistry and instrument response. A thermal neutron irradiation was performed to produce a sample that contained the radioisotopes of Sr and Cs. Even though the irradiated sample was not a certified standard it does provide accurate expectation values via published, well understood cumulative fission yield data. The results presented in this work correlate extremely well with the published data. Furthermore, a significant decrease in uncertainty (by a factor of 5 { 10) was found for the isotopic ratios measured with TIMS compared to the published values.

TIMS, environmental contamination, radiostrontium,↗

Simplified Thermal Analyzer --VAX Version

DEC VAX 11/780 version of the Simplified Shuttle Payload Thermal Analyzer (SSPTA) aids in evaluating thermal design of instruments to be flown in the Space Shuttle cargo bay. SSPTA is a collection of programs that are currently used in thermal analysis of spacecraft, modified for quick, preliminary analysis of payloads.

Skladany, J. T.↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Starprobe thermal shield system design concepts

The mission goals, flight trajectory, and material durability requirements for the NASA Starprobe spacecraft are reviewed. The spacecraft will use a Jovian gravity assist to pass within four solar radii of the sun to study fields and particles near the sun, perform experiments dealing with relativity and gravity, and observe the structure of the solar atmosphere from the photosphere to the corona. Constraints on the system size and mass design are given, and the system is noted to be required to withstand 2500 K at perihelion, thermally insulate the instrument payload, have a tube for optical measurements, and provide protection from meteorite damage. A secondary shield is also required to dispense thermal radiation that passes the primary shield and could endanger the payload. Design options are discussed, along with temperature control requirements and a conical carbon-carbon primary shield with mass-loss rate characteristics sufficient to meet a 2.5 mg/sec criterion.

Maag, C. R.↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing of a 40-kWth Counterflow Particle-Supercritical Carbon Dioxide Narrow-Channel, Fluidized Bed Heat Exchanger

Particle-based primary heat exchangers (HXs) must deliver sCO2 fluid temperatures above 700°C to couple particle-based concentrating solar receivers and thermal energy storage (TES) sub-systems with efficient sCO2 power cycles. Particle-sCO2 HX designs have struggled to meet DOE cost targets (≤ $150/kWth) due to the amount of expensive nickel alloys necessary for manufacturing full-scale, particle-sCO2 HXs. Our team has demonstrated that mild bubbling fluidization of falling particles in a counterflow narrow-channel fluidized bed can reduce required HX surface area and thus, costs by increasing particle-wall heat transfer coefficients hT,w > 800 W m-2 K-1. This paper reports on the fabrication and testing of a stainless steel, particle-sCO2 HX with 12 fluidized-bed channels approximately 10.5 mm deep spaced between diffusion-bonded, micro-channel sCO2 plates. The HX with a core length of ≈0.56 m is fed with CARBOBEAD HSP particles through a short, fluidized freeboard zone just above the core. Testing to date in the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories has shown that parallel bed fluidization maintains uniform particle inventory across the instrumented channels. Heat transfer thermal duty between the particle and sCO2 flows exceeds 30 kWth with sCO2 inlet temperatures of 200ºC and particle inlet temperatures up to 440ºC and mass flow rates of 0.2 kg s-1 fluidized by counterflowing gas flow rates of 0.005 kg s-1. Tests at higher particle and sCO2 inlet temperatures (600ºC and 400ºC respectively) are targeted to achieve > 40 kWth with model-predicted overall heat transfer coefficients U > 400 W m-2 K-1.

14 SOLAR ENERGY↗

Thermoelectric temperature control system for the pushbroom microwave radiometer (PBMR)

A closed loop thermoelectric temperature control system is developed for stabilizing sensitive RF integrated circuits within a microwave radiometer to an accuracy of + or - 0.1 C over a range of ambient conditions from -20 C to +45 C. The dual mode (heating and cooling) control concept utilizes partial thermal isolation of the RF units from an instrument deck which is thermally controlled by thermoelectric coolers and thin film heaters. The temperature control concept is simulated with a thermal analyzer program (MITAS) which consists of 37 nodes and 61 conductors. A full scale thermal mockup is tested in the laboratory at temperatures of 0 C, 21 C, and 45 C to confirm the validity of the control concept. A flight radiometer and temperature control system is successfully flight tested on the NASA Skyvan aircraft.

Dillon-Townes, L. A.↗

Graphite/polyimide laminates with near-zero thermal expansion

Composite structures can be laminated to have very low coefficients of thermal expansion. Such structures are light and strong and have many uses where expansion or contraction with temperature change is undesirable. One application is with instruments that measure thermal expansion.

Reynolds, W. N.↗

Water-Repellency Probe

Instrument yielding presence or absence of waterproofing agent at any given depth in blanket developed. In original application, blankets in question part of space shuttle thermal protection system. Instrument utilized to determine extent of waterproofing "burnout" due to re-entry heating and adverse environment exposure.

Rosen, Charles D.↗

Operations Concept for Responding to Urgent Requests for NASA-ISRO Synthetic Aperture Radar (NISAR)

The NASA-ISRO Synthetic Aperture Radar, or NISAR, mission is an Earth-mapping radar observatory to be launched from Sriharikota (India) in 2022. This mission is a collaboration between the National Aeronautics and Space Administration (NASA) and the Indian Space Research Organization (ISRO). This spacecraft will carry two instruments that will operate at radar wavelengths (L and Sband) and will provide data for understanding changes in the Earth’s land surface. The scientific data from this mission will revolutionize our understanding of the causes and consequences of land surface changes on Earth, ranging from Solid Earth Deformation in the form of natural hazards like earthquakes, volcanic eruptions and landslides, to ecosystem disturbances, to changes in the cryosphere (measurements of polar ice caps, ice sheets and sea ice). A nominal Reference Observation Plan, that repeats roughly every 12-24 days, developed prior to launch by the NISAR Mission Planning team, in consultation with the Science Team, will form the basis of science data collection by the payload instruments onboard the NISAR observatory after launch. Scheduling of science observations for the mission requires accounting for limited spacecraft resources like onboard data storage, downlink capacity, energy/power, thermal limits and instrument duty cycles. In addition to nominal science data collection, the project has a Level 1 requirement to respond to requests for urgent data acquisition over disaster sites (natural or anthropogenic) by scheduling new acquisitions within 24 hrs of notification and delivering science data within 5 hours of data acquisition. This capability is to be exercised on a ‘best-efforts basis’. While the definition of what constitutes an ‘urgent request’, and how such requests would be submitted to the project, is within the domain of the Science Team, the Mission System team is responsible for developing the baseline operations concept and implementation approach for responding to such requests. Given the ‘best-efforts’ nature of this requirement, a few highlevel guidelines have been developed to help guide the formulation of the operations concept, and are presented in this paper. Requests for urgent response data will be accommodated following the guiding principle of minimal to no impact on nominal science and planned engineering activities. No change in satellite orbit or attitude will be made for urgent response. Restricting response approaches to only changing the downlink and/or ground processing priority for existing observations, and adding new observations only in areas where NISAR will not be nominally imaging, allows for minimal impact on the Reference science Observation Plan. No instrument mode changes will be allowed for urgent response (except for high-priority requests), and no new observations that impact either planned science or engineering activities will be scheduled. Additionally, data requests must fit within the available project resource margins (both spacecraft and ground resources are to be evaluated). Both JPL and ISRO will be involved at various steps of the implementation, irrespective of whether the urgent request is for L-SAR (NASA instrument) or S-SAR (ISRO instrument) or a joint dataset.

Sharma, Priyanka↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Progress Update on the In Situ Load Retention Aging Vessel

To improve upon our conventional thermally accelerated aging study methods which require periodic interruption of aging to perform load testing in an Instron machine, a new aging system is being developed to: (1) automate/facilitate data acquisition/analysis, (2) improve data quality, and (3) enable uninterrupted aging conditions (compression, temperature, atmosphere) which represents the service condition. In FY24, a thermal aging vessel instrumented with load cells was fabricated and tested. That unit demonstrated the primary function of the vessel: to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary objective, not realized in the unit due to inadequate sealing, was to enable a single initial nitrogen backfill (as opposed to a continuous purge) and gas sampling of the vessel headspace during thermal aging. Heating of the vessel was achieved using a custom heater jacket.

36 MATERIALS SCIENCE↗

In-Situ Focusing Inside a Thermal Vacuum Chamber

Traditionally, infrared (IR) space instruments have been focused by iterating with a number of different thickness shim rings in a thermal vacuum chamber until the focus meets requirements. This has required a number of thermal cycles that are very expensive as they tie up many integration and test (I&T)/ environmental technicians/engi neers work ing three shifts for weeks. Rather than creating a test shim for each iteration, this innovation replaces the test shim and can focus the instrument while in the thermal vacuum chamber. The focus tool consists of three small, piezo-actuated motors that drive two sets of mechanical interface flanges between the instrument optics and the focal- plane assembly, and three optical-displacement metrology sensors that can be read from outside the thermal vacuum chamber. The motors are used to drive the focal planes to different focal distances and acquire images, from which it is possible to determine the best focus. At the best focus position, the three optical displacement metrology sensors are used to determine the shim thickness needed. After the instrument leaves the thermal vacuum chamber, the focus tool is replaced with the precision-ground shim ring. The focus tool consists of two sets of collars, one that mounts to the backside of the interface flange of the instrument optics, and one that mounts to the backside of the interface flange of the focal plane modules. The collars on the instrument optics side have the three small piezo-actuated motors and the three optical displacement metrology systems. Before the instrument is focused, there is no shim ring in place and, therefore, no fasteners holding the focal plane modules to the cameras. Two focus tooling collars are held together by three strong springs. The Orbiting Carbon Observatory (OCO) mission spectrometer was focused this way (see figure). The motor described here had to be moved five times to reach an acceptable focus, all during the same thermal cycle, which was verified using pupil slicing techniques. A focus accuracy of .20.100 microns was achieved.

Liebe, Carl Christian↗

Fabrication of a Thermally Isolated and Pre-amplified Transistor Module with Polyimide Micro-wires for Cryogenic Detectors

For use in cryogenic applications such as bolometer and x-ray microcalorimeter arrays, pre-amplifying Junction Field Effect Transistors (JFETs) are often required for the readout electronics. The optimum operating temperature of the JFETs is 130 Kelvin while the cryogenic detectors operate in the milli-Kelvin range. Thus, the JFETs must be heated up but thermally isolated from the surrounding cryogenic instruments. In the past, the thermal isolation was accomplished by suspending the JFETs with low conductance wires such as manganium or stainless steel on a Kevlar support platform [I]. This also achieved electrical connections. However, this assembly required manual soldering work, which could raise a reliability issue for the cryogenic applications. In order to eliminate the manual work, polyimide micro-wires were developed [2]. The wires must be of sufficient length to decrease the heat load and in tension to prevent microphonic noise from vibration of the wires: the polyimide wires were patterned into llS"shaped curves over a thin metal wires such as aluminum, titanium, or niobium. The bilayer of the films were then suspended by etching silicon substrate thus to make freestanding air bridges (enough explanation?). In this paper, we present a method to fabricate micromachined JFET mechanical modules suspended by polyimide Pyraline micro-wires and heated up with built-in aluminum micro-heaters.

Oh, L. H.↗