Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Impedance-Based State-of-Health Estimation for Lithium-Ion Battery Management Systems

This paper discusses an impedance-based state-of-health (SOH) estimation for lithium-ion battery management systems. Features obtained from the Nyquist plot of the electrochemical impedance spectroscopy (EIS) are utilized to estimate the SOH. Two commercial lithium-ion batteries were aged (cycled) in the laboratory to collect aging and impedance data. An algorithm for SOH estimation is presented and evaluated. The performance evaluation results show that the SOH features extracted from the Nyquist plot can be utilized for SOH estimation. Estimated SOH values can be then utilized in various battery management systems (BMS) functions such as for calibrating the available capacity, adjusting charging/discharging strategies, and protection.

Al-Smadi, Mohammad↗

PHIL Validation of Ultracapacitor Storage for Black Start Application

A deck of slides that present the modeling, and calibration to conduct PHIL test of ultracapacitor energy storage system. The PHIL test has been done while preparing for the black start field demonstration with Idaho Falls Power. Presentation is invited to the 6th International Workshop on Grid Simulator Testing of Wind Turbine Power Trains and Other Renewable Technologies.

13 HYDRO ENERGY↗

Mass Spectrometer Transient Analysis

This software implements a complete preprocessing pipeline for transient mass spectrometry (MS) data collected during TAP (Temporal Analysis of Products) experiments. It is designed to extract chemically meaningful fluxes from overlapping ion signals by applying a calibrated defragmentation matrix and solving the resulting linear system using non-negative least squares (NNLS) regression. The core script, preprocess_mass_spec.py, performs the following operations: Gain correction: Applies amplifier gain scalars derived from inert-packed calibration pulses to normalize signal intensities across AMUs and acquisition settings. Background subtraction: Removes experiment baselines using user-defined time windows, ensuring compatibility with slow-diffusing species and preventing negative values that would interfere with NNLS. Options to subtract before and after defragmentation. Defragmentation: Constructs a fragmentation matrix A from zeroth moments of calibration pulses (equal molar gas:inert mixtures) and solves Ax=b at each time point, where b is the raw MS signal and x is the estimated species flux. The matrix is normalized to inert signals and accounts for instrument-specific fragmentation behavior. Pulse-mode handling: Supports both averaged and individual pulse modes, enabling statistical treatment of fluxes and calculation of standard deviations. Integration and output: Computes zeroth moments (integrated fluxes) and exports time-resolved and integrated data in CSV format, suitable for downstream kinetic modeling. The software is validated using both virtual TAP simulations (VTAP) and experimental data from propane dehydrogenation (PDH) on CrOx/Al2O3 catalysts. It preserves temporal resolution by applying NNLS point-by-point across the pulse duration (typically 6,000+ time slices per pulse), leveraging the linear superposition principle to reconstruct full flux profiles. The defragmented outputs are compatible with kinetic extraction methods such as the G and Y procedures, which are used to derive rate–concentration relationships from TAP data. The details of these validations are discussed in detail in the supporting manuscript and supporting information. Example data and output files are also included. The methodology is robust to experimental noise and drift, with calibration protocols that account for pulse size effects, MS aging, and inert gas normalization. The software is modular, reproducible, and tailored for high-throughput TAP-MS workflows in catalysis research.

Kristy, Stephen [Idaho National Laboratory (INL), ↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗

Hypergames and Cyber-Physical Security for Control Systems

The identification of the Stuxnet worm in 2010 provided a highly publicized example of a cyber attack that physically damaged an industrial control system. This raised public awareness about the possibility of similar attacks against other industrial targets—including critical infrastructure. Here, we use hypergames to analyze how strategic perturbations of sensor readings and calibrated parameters can be used to manipulate a system that employs optimal control. Hypergames form an extension of game theory that enables us to model strategic interactions where the players may have significantly different perceptions of the game(s) they are playing. Past work with hypergames has focused on relatively simple interactions consisting of a small set of discrete choices for each player. Here, we apply single-stage hypergames to larger systems with continuous variables. We find that manipulating constraints can be a more effective attacker strategy than manipulating objective function parameters. Moreover, the attacker need not change the underlying system to carry out a successful attack—it may be sufficient to deceive the defender controlling the system. It is possible to scale our approach up to even larger systems, but this will depend on the characteristics of the system in question, and we identify several characteristics that will make those systems amenable to hypergame analysis.

97 MATHEMATICS AND COMPUTING↗

Application of motional Stark effect in situ background correction to a superconducting tokamak

A polychrometer-type motional Stark effect (MSE) diagnostic technique, originally developed for the Alcator C-Mod tokamak, has been extended and applied to the Korea Superconducting Advanced Tokamak Research (KSTAR) device, the long-pulse superconducting tokamak, for the first time. It demonstrates a successful in situ subtraction of the polarized reflections off the vacuum vessel wall, sometimes up to half the total signal in some sightlines. To avoid the secondary neutral beam emission that may contaminate conventional beam-into-gas calibrations, a new approach, where the beam-into-gas measurements are made at various torus pressures with fixed vacuum fields, has been devised, which is possible with the stable superconducting coil systems of KSTAR. The validity of this new calibration scheme has been checked via plasma jog experiments. The experimental evidence of the polarized background light and the necessity of its correction in the MSE measurements made in KSTAR are presented as well.

47 OTHER INSTRUMENTATION↗

INVESTIGATION OF HUMAN RELIABILITY ANALYSIS METHODS FOR ANALYZING PRE-INITIATORS

As a type of human actions defined in human reliability analysis (HRA), pre-initiator refers to the human actions that may lead to the unavailability of systems, typically committed during maintenance, test, or calibration. This paper investigates representative HRA methods used for analyzing pre-initiators. The HRA methods are Technique for Human Error Rate Prediction (THERP), Korean Standard HRA (K-HRA) and Standard Plant Risk HRA (SPAR-H). In this paper, characteristics of each HRA method are compared for qualitative and quantification aspects. Two pre-initiators, i.e., a calibration task and a valve restoration task, are analyzed using the HRA methods to compare human error probabilities. Then, insights from the analysis and additional research requirements are discussed in this paper.

99 GENERAL AND MISCELLANEOUS↗

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Autonomous sensor suite for evaluating fish-turbine interactions and environmental impacts in marine renewable energy and hydropower

Marine renewable energy (MRE) harnesses ocean-based resources such as waves, tides, currents, and thermal or salinity gradients for sustainable power generation. It has the potential to complement existing renewable resources, support remote communities, and contribute to decarbonization efforts. However, understanding the hydrodynamic forces created by MRE devices and their impacts on marine life is critical for responsible deployment. Here, to address these concerns, advanced sensor devices, including the Marine Sensor Fish (MSF), Sensor Fish Mini (SF Mini), and Flexible Sensor Fish (FSF), were developed to measure interactions between aquatic organisms and MRE systems. This paper details the design, manufacturing, calibration, and field deployment of these sensor suites, highlighting their ability to capture key physical stressors such as shear forces, pressure changes, and collision impacts. The MSF successfully evaluated turbine interactions at a tidal turbine in the Salish Sea, capturing data on turbulence, collision impact, and pressure gradients. The SF Mini validated hydrodynamic conditions in scaled hydraulic models, supporting computational fluid dynamics simulations. The FSF, with its flexible silicone body, measured species-specific impacts in turbulent environments. This research demonstrates the potential of Sensor Fish technology to advance sustainable marine energy systems by reducing biological impacts and informing environmentally sustainable designs.

Ecological impacts↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

A multi-wavelength streaked optical pyrometer for dynamic shock compression measurements above 2500 K

This work presents a concept and implementation of a calibrated streaked spectral pyrometer (SSP) temperature diagnostic used in dynamically driven shock experiments on a two-stage gas gun. This system relies upon measuring the total system response using a tunable monochromator, a NIST-traceable calibrated power meter, and a SSP. The diagnostic performance is validated against previously measured temperatures of shock driven z-cut quartz at 99 GPa and 93 GPa. The results are found to agree with the literature to within 5% and are discussed in this manuscript. The experimental setup utilizes measurements from multiple SSP systems per sample, providing several independent measurements and substantially increasing confidence in the extrapolated shock driven sample temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NIF-TAS Miniature Calibration Station

“On Aug. 8, 2021, an experiment at Lawrence Livermore National Laboratory’s (LLNL’s) National Ignition Facility (NIF) made a significant step toward ignition, achieving a yield of more than 1.3 megajoules (MJ). This advancement puts researchers at the threshold of fusion ignition, an important goal of the NIF, and opens access to a new experimental regime.” NIF experiments are conducted by symmetrically focusing 192 laser beams from NIF (three football fields in length) into the Target Chamber (10-meter diameter sphere) onto a target 2mm in size. The reaction produces a hot spot the diameter of a human hair, generating more than 10 quadrillion watts of fusion power for 100 trillionths of a second. These high pressures and temperatures created by the NIF have only been seen on the surface of the sun. To achieve fusion ignition, the target must be compressed to high pressures and temperatures, which requires symmetric compression. This symmetry requires precise alignment of the laser beams to the target. To achieve this precise symmetry a Target Alignment System (TAS) was developed to aid in aligning the beams to the target. The accomplishment on Aug 8 th could not have been accomplished without the TAS. TAS has proven to be a critical contributor to the success of NIF experiments. Each TAS is composed of several Charge Couple Device (CCD) sensors and various support electronics. Unfortunately, these CCDs are no longer available in industry as they have become outdated and obsolete. There is a limited amount of spare CCDs in the facility. As the NIF continues to increase its energy output of its fusion ignition shot experiments (heigh yield shots), more neutrons are being emitted from the Target Chamber. These neutrons are very damaging to the TAS electronics and its sensors, thus degrading and reducing its life expectancy dramatically. The increase of neutrons exceeds the damage threshold of the CCDs. This would increase the demand for more frequent TAS refurbishments and calibrations. The increase in resources to perform these refurbishments and calibrations would not be sustainable. In efforts to prolong the life of each TAS system it was determined that the TAS should be removed for every High Yield Shot and then reinstalled. The high precision fully calibrated TAS can easily be knocked out of alignment during these installs and reinstall exchanges and being transported in and out of the NIF. The Miniature Calibration Station System was developed to verify that the critical calibration parameters have been preserved during every TAS exchange. The Miniature Calibration Station System (Mini-Cal) would need to be a scaled down (in size and scope), portable version of the offline TAS calibration station to verify the critical TAS parameters are still within tolerances.

42 ENGINEERING↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

FY24 Progress Report on Viscosity and Thermal Conductivity Measurements of Nuclear Industry Relevant Chloride Salts: An Experimental and Computational Study

As presented in this report, experimental and computational techniques were performed to assess the viscosity and thermal conductivity of key alkali and actinide chloride mixtures for molten salt reactor developers. These mixtures were pure LiCl, NaCl-KCl, LiCl-NaCl, LiCl-KCl, LiCl-NaCl-KCl, and NaCl-UCl 3 . Experimental measurements of viscosity were performed with a rolling ball viscometer, whereas experimental measurements of thermal conductivity were performed with a variable gap apparatus. Additional benchmarking work was performed using both property measurement systems to prepare for x-ray radiography in stainless-steel crucibles for viscosity and to ensure that calibration methods were accurate for thermal conductivity before assessing the NaCl-UCl 3 system. Validation data for the NaCl-UCl 3 in literature are minimal. Details on the calibration methods, salt measurement processes, and sources of error and uncertainty are discussed in detail for both property measurements. The computational methods described herein involved ab-initio molecular dynamics (AIMD) calculations using CP2K. The calculations were performed for the LiCl-KCl-NaCl and NaCl-UCl 3 systems. These calculations not only provided thermophysical property estimations for comparison to experimental data, but they also allowed for the determination of diffusion coefficients, coordination numbers, and radial distribution functions to provide insight into ion mobility and local coordination environments, which is linked to macroscopic property trends.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Performance Computing Traffic Simulations for Real-Time Traffic Control of Mobility in Chattanooga Region

In 2019, highway congestion wasted over 3 billion gallons of fuel and caused 8.8 billion hours of lost productivity.1 Research has shown that introducing near-real time traffic controls can significantly reduce congestion. Validated and calibrated traffic simulations enable the modeling of transportation systems and the evaluation of different traffic control actions and schemes given a variety of circumstances that represent likely future scenarios. The developed scenarios can inform the deployment of controls in near real-time to improve freight and passenger vehicle congestion and energy use. In this work, we present simulations used to model the traffic in the Chattanooga, Tennessee, metropolitan area. Simulations were constructed and calibrated using a variety of local, data science enhanced, data sources utilizing open source software including the Simulation of Urban Mobility (SUMO) simulator. High-Performance Computing (HPC) provides a scalable platform with enough computing for the high-fidelity simulation of many scenarios and the application of advance data science especially for large-scale systems. Our simulations include microscopic simulations at a corridor level for traffic signal control, and mesoscopic simulations to evaluate regional operational controls and infrastructure.

97 MATHEMATICS AND COMPUTING↗

Hydrous SiO 2 in subducted oceanic crust and H 2 O transport to the core-mantle boundary

Subduction of oceanic lithosphere transports surface H 2 O into the mantle. Recent studies show that dense SiO 2 in the form of stishovite, an abundant mineral in subducted oceanic crust at depths greater than ~270 km, has the potential to host and transport a considerable amount of H 2 O into the lower mantle, but the H 2 O storage capacity of SiO 2 phases at high pressure and temperature remains uncertain. We investigate the hydration of stishovite and its higher-pressure polymorphs, β-stishovite and seifertite, with in situ X-ray diffraction experiments at high pressures and temperatures. The H 2 O contents in SiO 2 phases are quantified based on observed increases in unit cell volume relative to the anhydrous SiO 2 system. Density functional theory (DFT) computations permit calibration of water content as a function of volume change based on interstitial substitution of H 2 O. Regression of our experimental data indicates an H 2 O storage capacity in stishovite of ~3.5 wt% in the transition zone and shallow lower mantle, decreasing to about 0.8 wt% at the base of the mantle. We find that SiO 2 -bearing subducted oceanic crust can accommodate all the H 2 O in slab lithosphere that survives sub-arc dehydration. Hydration of silica phases in subducted oceanic crust and their unparalleled capacity to host significant amounts of H 2 O even at high mantle temperatures provides a unique mechanism for transport and storage of water in the deepest mantle.

58 GEOSCIENCES↗