Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Application of airborne infrared technology to monitor building heat loss

The application of airborne infrared technology to the requirements for energy conservation in buildings was studied. Quantitative airborne data of the City of Ypsilanti, Michigan, were collected and processed to identify roof temperatures. A thermal scanner was flown at an altitude of 1,200 feet with two thermal bands 8.2-9.3 micrometers and 10.4-12.5 micrometers recorded by an analog system. Calibration was achieved by standard hot and cold plates. Using a thermal model to interpret ceiling insulation status, environmental factors were found to influence the relation between roof temperature and insulation. These include interior and sky temperatures, roofing materials, and the pitch and orientation of the roof. A follow-up mail survey established the ability to identify insulated and uninsulated houses from the airborne infrared data.

Tanis, F. J.↗

Large Antenna Multifrequency Microwave Radiometer (LAMMR) system design

The large Antenna Multifrequency Microwave Radiometer (LAMMR) is a high resolution 4 meter aperture scanning radiometer system designed to determine sea surface temperature and wind speed, atmospheric water vapor and liquid water, precipitation, and various sea ice parameters by interpreting brightness temperature images from low Earth orbiting satellites. The LAMMR with dual linear horizontal and vertical polarization radiometer channels from 1.4 to 91 GHZ can provide multidiscipline data with resolutions from 105 to 7 km. The LAMMR baseline radiometer system uses total power radiometers to achieve delta T's in the 0.5 to 1.7 K range and system calibration accuracies in the 1 to 2 deg range. A cold sky horn/ambient load two point calibration technique is used in this baseline concept and the second detector output uses an integrated and dump circuit to sample the scanning cross-tract resolution cells.

King, J. L.↗

On the design of a postprocessor for a search for extraterrestrial intelligence /SETI/ system

The design of an on-line postprocessor for a search for extraterrestrial intelligence (SETI) system is described. Signal processing tasks of the postprocessor include: (1) analysis of power level, phase coherence, and state of polarization of single-channel signals in a search for significant signals; (2) grouping or aggregation of adjacent channel data, time averaging of data; and (3) the detection of drifting and modulated signals. Control functions include multichannel spectrum analyzer frequency and clock control, system calibration and selfdiagnostic, control of data flow to and from short-term and long-term (archival) memories, and operation of detection subsystems, such as a visual display and a tunable receiver.

Healy, T. J.↗

The MSFC vector magnetograph

The NASA/Marshall Space Flight Center's solar vector magnetograph system allows measurements of all components of the Sun's photospheric magnetic field over a 5 x 5 or 2.5 x 2.5 arc min square field of view with an optimum time resolution of approximately 100 sec and an optimum signal-to-noise of approximately 1000. The basic system components are described, including the optics, detector, digital system, and associated electronics. Automatic sequencing and control functions are outlined as well as manual selections of system parameters which afford unique system flexibility. Results of system calibration and performance are presented, including linearity, dynamic range, uniformity, spatial and spectral resolutions, signal-to-noise, electro-optical retardation and polarization calibration.

Hagyard, M. J.↗

A high precision Solar Ultraviolet Spectral Irradiance Monitor for the wavelength region 120-400 nm

There exists a growing need to improve the accuracy of measurement of the absolute solar flux within the wavelength range 120-400 nm. Although full-disk solar fluxes and variations thereof in the 120-400 nm region are required to model the solar atmosphere, current increased interest in the measurements arises from their importance in modeling the terrestrial atmosphere. The Solar Ultraviolet Spectral Irradiance Monitor (SUSIM) experiment under development for flight aboard the Space Shuttle and the Upper Atmospheric Research Satellite is described. SUSIM will monitor the solar flux in the 120-144 nm region with high precision, using an in-flight calibration system to reduce absolute error to less than 10%, and error relative to the 400 nm continuum to less than 1%.

Vanhoosier, M. E.↗

Four frequency ground scatterometer

The FM-CW Radar, used as a microwave scatterometer is described. Scatterometer system design, scatterometer system calibration, parameter calculation and correction for data acquisition, ground scatterometer data acquistion at Jornada Experimental Range, and Kansas radar cross-calibration test are discussed.

Dickerson, E. T.↗

Sensor-induced temporal variability of Landsat MSS data

Landsat-1 and Landsat-2 multispectral scanner (MSS) data were studied to determine the consistency of the calculated reflectance values over time. Data from six spectrally stable targets were collected over a 3-year period (1975-1977). Reflectance values calculated from the digital numbers were regressed against time to note any long term changes. Results indicate that, over a 1000-day period beginning 1 January 1975, MSS 2 reflectances were stable. MSS 1 reflectances over that same period decreased approximately 25-32 percent. The observed decreases are most likely due to a deterioration of the transmissive qualities of the Landsat-1 scanner's internal optical path. Although MSS temporal variation may be unique to MSS 1, time (days in orbit) should be considered as an independent variable when intersatellite calibration equations are computed. A case is made for a stable, monitored calibration system which would permit the calculation of true top-of-the-atmosphere reflectance measures.

Nelson, R. F.↗

International Ultraviolet Explorer Observatory operations

This volume contains the final report for the International Ultraviolet Explorer IUE Observatory Operations contract. The fundamental operational objective of the International Ultraviolet Explorer (IUE) program is to translate competitively selected observing programs into IUE observations, to reduce these observations into meaningful scientific data, and then to present these data to the Guest Observer in a form amenable to the pursuit of scientific research. The IUE Observatory is the key to this objective since it is the central control and support facility for all science operations functions within the IUE Project. In carrying out the operation of this facility, a number of complex functions were provided beginning with telescope scheduling and operation, proceeding to data processing, and ending with data distribution and scientific data analysis. In support of these critical-path functions, a number of other significant activities were also provided, including scientific instrument calibration, systems analysis, and software support. Routine activities have been summarized briefly whenever possible.

Source record↗

The Orbital Acceleration Research Experiment

The hardware and software of NASA's proposed Orbital Acceleration Research Experiment (OARE) are described. The OARE is to provide aerodynamic acceleration measurements along the Orbiter's principal axis in the free-molecular flow-flight regime at orbital attitude and in the transition regime during reentry. Models considering the effects of electromagnetic effects, solar radiation pressure, orbiter mass attraction, gravity gradient, orbital centripetal acceleration, out-of-orbital-plane effects, orbiter angular velocity, structural noise, mass expulsion signal sources, crew motion, and bias on acceleration are examined. The experiment contains an electrostatically balanced cylindrical proofmass accelerometer sensor with three orthogonal sensing axis outputs. The components and functions of the experimental calibration system and signal processor and control subsystem are analyzed. The development of the OARE software is discussed. The experimental equipment will be enclosed in a cover assembly that will be mounted in the Orbiter close to the center of gravity.

Blanchard, R. C.↗

Flow field measurements in a 90 degree turning duct

The objective of this investigation is the experimental evaluation of the influence of inlet turbulence intensity on secondary flow development in a turning duct. The existing 25.4 cm square turning duct (90) facility is being utilized to investigate of bulk turbulence levels on secondary flow development. The large scale duct flow facility allows detailed mean velocity and turbulence quantities to be measured at several streamwise planes in the curved duct. Non-intrusive laser velocimetry is being used to measure the mean and fluctuating components of velocity in all three orthogonal directions. To assure that the turbulence measurements are unbiased by particle lag and other effects, comparison hot wire data will be taken to validate the laser velocimetry system calibration.

Crawford, Roger A.↗

Remote sensing from space; Proceedings of Symposium 3, Workshop V, and Topical Meeting A2 of the Twenty-sixth COSPAR Plenary Meeting, Toulouse, France, June 30-July 11, 1986

Various papers on remote sensing from space are presented. The use of such remote sensing to study terrestrial patterns and processes is examined, including the relevant processes and theories, observed vegetation and surface climate parameters, derived terrestrial processes, atmospheric effects, and new sensors. Quantitative radar remote sensing of land and oceanic surface features is addressed, including systems, calibration, simulation, data evaluation for vegetational studies, altimetry, sea ice monitoring, and oil slick detection. The use of satellite observations for weather prediction is discussed.

Goward, S. N.↗

Digital control of wind tunnel magnetic suspension and balance systems

Digital controllers are being developed for wind tunnel magnetic suspension and balance systems, which in turn permit wind tunnel testing of aircraft models free from support interference. Hardware and software features of two existing digital control systems are reviewed. Some aspects of model position sensing and system calibration are also discussed.

Britcher, Colin P.↗

A flow-transfer device with nonmetallic diaphragms for propulsion wind tunnel models

The Langley Research Center has developed a new flow-transfer device for powered wind tunnel models in which the traditional metal bellows have been replaced with nonmetallic diaphragms. Two complete flow transfer assemblies have been fabricated and installed within a twin-jet propulsion simulation system. Calibrations of the force balance have been performed over a range of nozzle mass flow rates up to 15 lbs/sec in order to validate the nonmetallic diaphragm design concept. Results from these calibrations are compared to those obtained with flow-transfer devices utilizing metal bellows.

Capone, Francis J.↗

Design and simulated performance of a CARS spectrometer for dynamic temperature measurements using electronic heterodyning

A new design for generating CARS signals and for the detection and processing of these signals is presented and evaluated. The design is based on electronic heterodyning of the CARS spectrum of nitrogen at two selected narrowband frequencies, ratioing the resulting signal strengths, and comparing this ratio with a theoretically derived temperature scale. A reference cell is incorporated into the design for system calibration and for accurate temperature measurements. The spectrometer is found capable of measuring temperature in the submillisecond time scale with an accuracy of 10 percent in the 1000-2000 K temperature range. A typical result using the Hg(x)Cd(1-x)Te photomixer for T = 1500 K, Delta T = 50 K is a SNR of 21 dB and a data collection rate of 300 Hz.

Deen, M. Jamal↗

Characterizations of the Earth Radiation Budget Experiment (ERBE) scanning radiometers

NASA's Earth Radiation Budget Experiment employs the Earth Radiation Budget Satellite and the NOAA 9 and 10 spacecraft to obtain absolute measurements of incoming solar radiation, shortwave earth-reflected solar radiation, and longwave earth-emitted radiation, using both scanning and nonscanning radiometers. Each of the three remote-sensing spacecraft carry narrow FOV scanning radiometers whose detection sensors are thermistor bolometers. Attention is presently given to the calibration models and methods employed in characterizing the scanning radiometers' output signals; the design features of the scanners and flight calibration systems are presented.

Lee, Robert B., III↗

Report of the panel on international programs

The panel recommends that NASA participate and take an active role in the continuous monitoring of existing regional networks, the realization of high resolution geopotential and topographic missions, the establishment of interconnection of the reference frames as defined by different space techniques, the development and implementation of automation for all ground-to-space observing systems, calibration and validation experiments for measuring techniques and data, the establishment of international space-based networks for real-time transmission of high density space data in standardized formats, tracking and support for non-NASA missions, and the extension of state-of-the art observing and analysis techniques to developing nations.

Anderson, Allen Joel↗

Recent results from the InP homojunction cell module on the LIPS III spacecraft

The flight performance of the NASA Lewis Research Center's indium phosphide homojunction cell module on the LIPs III spacecraft is presented. Four n+-p diffused junction cells, an early product of an InP development program, were flown. The voltage range of the data prohibits determination of the open-circuit voltage or the maximum power point. However, analysis of the 32 months of short-circuit current data reveals a slight increase, not the 4 percent decrease expected from radiation tolerance studies. This increase may be due to continual cleaning of possible prelaunch dust contamination or changes in data acquisition system calibration. For all cells, the average short-circuit current remains below prelaunch values.

Brinker, David J.↗

Characterization of the Earth Radiation Budget Experiment radiometers

The Earth Radiation Budget Experiment (ERBE) scanning radiometers were used to measure the earth's radiation fields during the period November 1984 through February 1990. The ERBE radiometric packages were placed into orbit aboard the Earth Radiation Budget Satellite (ERBS) and the NOAA-9 and NOAA-10 spacecraft platforms. In each radiometric package, thermistor bolometers were used as detection elements for the broadband total (0,2 - 50,0 microns), shortwave (0,2 - 5,0 microns), and longwave (5,0 - 50,0 microns) spectral regions. Flight calibration facilities were built into each of the spacecraft radiometric packages. The flight facilities consisted of black bodies, tungsten lamps, and silicon photodiodes. The black bodies and tungsten lamps were found to be reliable at precision levels approaching 0,5 percent over a five-year period. The photodiodes were found to degrade more than 2 percent during the first year in orbit. In this paper, the flight calibration systems for the ERBE scanning radiometers are described along with the resultant measurements.

Lee, R. B., III↗