Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopic techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Characterization of Deposits on Glass Substrate as a Tool in Failure Analysis: The Orbiter Vehicle Columbia Case Study

In connection with the accident investigation of the space shuttle Columbia, an analysis methodology utilizing well established microscopic and spectroscopic techniques was implemented for evaluating the environment to which the exterior fused silica glass was exposed. Through the implementation of optical microscopy, scanning electron microscopy, energy dispersive spectroscopy, transmission electron microscopy, and electron diffraction, details emerged regarding the manner in which a charred metallic deposited layer formed on top of the exposed glass. Due to nature of the substrate and the materials deposited, the methodology proved to allow for a more detailed analysis of the vehicle breakup. By contrast, similar analytical methodologies on metallic substrates have proven to be challenging due to strong potential for error resulting from substrate contamination. This information proved to be valuable to not only those involved in investigating the break up of Columbia, but also provides a potential guide for investigating future high altitude and high energy accidents.

Olivas, J. D.↗

Exoplanet Transit Spectroscopy Using WFC3: WASP-12b, WASP-17b, and WASP-19b

We report an analysis of transit spectroscopy of the extrasolar planets WASP-12 b, WASP-17 b, and WASP-19 b using the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST). We analyze the data for a single transit for each planet using a strategy similar, in certain aspects, to the techniques used by Berta et al., but we extend their methodology to allow us to correct for channel- or wavelength-dependent instrumental effects by utilizing the band-integrated time series and measurements of the drift of the spectrum on the detector over time. We achieve almost photon-limited results for individual spectral bins, but the uncertainties in the transit depth for the band-integrated data are exacerbated by the uneven sampling of the light curve imposed by the orbital phasing of HST's observations. Our final transit spectra for all three objects are consistent with the presence of a broad absorption feature at 1.4 microns most likely due to water. However, the amplitude of the absorption is less than that expected based on previous observations with Spitzer, possibly due to hazes absorbing in the NIR or non-solar compositions. The degeneracy of models with different compositions and temperature structures combined with the low amplitude of any features in the data preclude our ability to place unambiguous constraints on the atmospheric composition without additional observations with WFC3 to improve the signal-to-noise ratio and/or a comprehensive multi-wavelength analysis. Key words: planetary systems - techniques: photometric - techniques: spectroscopic

HST↗

Uncertainties in Atomic Data and Their Propagation Through Spectral Models. I.

We present a method for computing uncertainties in spectral models, i.e., level populations, line emissivities, and emission line ratios, based upon the propagation of uncertainties originating from atomic data.We provide analytic expressions, in the form of linear sets of algebraic equations, for the coupled uncertainties among all levels. These equations can be solved efficiently for any set of physical conditions and uncertainties in the atomic data. We illustrate our method applied to spectral models of Oiii and Fe ii and discuss the impact of the uncertainties on atomic systems under different physical conditions. As to intrinsic uncertainties in theoretical atomic data, we propose that these uncertainties can be estimated from the dispersion in the results from various independent calculations. This technique provides excellent results for the uncertainties in A-values of forbidden transitions in [Fe ii]. Key words: atomic data - atomic processes - line: formation - methods: data analysis - molecular data - molecular processes - techniques: spectroscopic

linear sets↗

Survival of Organic Materials in Ancient Cryovolcanically-Produced Halite Crystals

Spectroscopic evidence supports the presence of Mg-Na-K salts derived from cryovolcanism on the surface of Europa. Halite (NaCl) is effective at very long-term preservation of organic phases and structures. Collection of salt crystals from Europan plumes would provide solid inclusions of organics, potentially also biomaterials, all suitable for analysis. Two thermally-metamorphosed ordinary chondrite regolith breccias (Monahans 1998 (H5) and Zag (H3-6)) contain fluid and solid inclusion-bearing halite crystals, dated to approximately 4.5 billion years, and thus the trapped aqueous fluids and solids are at least as old. Heating/freezing studies of the aqueous fluid inclusions in these halites demonstrated that they were trapped near 25 degrees Centigrade, and their continued presence in the halite grains requires that their incorporation into the H chondrite asteroid occurred after that body's metamorphism ended, since heating would have dessicated the halite. O and H isotopes of the trapped fluids are consistent with mixing of asteroidal and cometary water. Cryovolcanic Origin of the Halite: We hypothesize that these meteoritic halites derive from ancient cryovolcanism based on the following points. (1) Salts crystals are observed as products of current cryovolcanism on Enceladus. (2) In-situ spacecraft analysis of some of the icy grains associated with the Enceladus salt found minor organic or siliceous components, including methane, also found in the Monahans halite. (3) Cryovolcanic fluids are observed to be in chemical disequilibrium, reflecting incomplete reactions between interior volatiles and rocky materials. The coexistence of N2 and HCN in Enceladus' cryovolcanic fluids requires that the plume consists of a mixture of materials whose sources experienced different degrees of aqueous processing, including primordial material trapped in ice that has not been in contact with liquid water. The observed mineral assemblage within the Monahans and Zag halites is also far from equilibrium. Cryovolcanoes on Ceres are a potential source of our halite, however the processes that form halite should also be operating within Europa. Dissolution of Monahans halite grains has revealed a remarkable variety of organics, which dominate the population of solid inclusions. Thermal alteration of this macromolecular carbon (measured by Raman spectroscopy) shows remarkable diversity. We have identified highly-condensed aromatics, diamond, carbonates and chloromethane. Light organic compounds like methane tend to be water soluble and require cold formation temperatures at high hydrogen fugacity - i.e. require water ice. Another indication that these halites have not been heated is that light organics readily volatilize or aromaticize into PAHs. We are currently analyzing the organics by Raman and C-XANES, and measuring the content and exploring the potential chirality of amino acids in the halite. Implications for Europa Plumes: Organic materials and structures erupted by a Europa cryovolcano should be similarly preserved within halite, and other salts, which will be a convenient form for capture and analysis, since halite will serve to encapsulate and protect the organics from spacecraft contamination. Also, being transparent at many wavelengths halite will permit analysis by spacecraft-mounted spectroscopic techniques. In addition, halite is readily dissolved, permitting further analysis of entrained organics.

Zolensky, M.↗

A D- and N-15-Rich Micrometer-Sized Aggregate of Organic Matter in a Xenolithic Clast from the Zag Ordinary Chondrite

The nature and origin of extraterrestrial organic matter are still under debate despite the significant progress in the analyses and experimental approaches in this field over the last five decades. Xenolithic clasts are often found in a wide variety of meteorite groups, some of which contain exotic organic matter (OM). The Zag meteorite is a thermally-metamorphosed H ordinary chondrite. It contains a primitive xenolithic clast that has been proposed to have originated from Ceres, which was accreted to the Zag host asteroid after metamorphism. The cm-sized clast contains abundant large carbon-rich (mostly organic) grains or aggregates up to 20 microns. Such large OM grains are unique among astromaterials with respect to the size. Here we report organic and isotope analyses of a large (approx.10 microns) aggregate of solid OM in the Zag clast. The X-ray micro-spectroscopic technique revealed that the OM has sp2 bonded carbon with no other functional groups nor graphitic feature (1s-sigma exciton), and thus it is distinguished from most of the OM in carbonaceous meteorites. The apparent absence of functional groups in the OM suggests that it is composed of hydrocarbon networks with less heteroatoms, and therefore the OM aggregate is similar to hydrogenated amorphous carbon (HAC). The OM aggregate has high D/H and 15N/14N ratios, suggesting that it originated in a very cold environment such as the interstellar medium or outer region of the solar nebula, while the OM is embedded in carbonate-bearing matrix resulting from aqueous activities. Thus the high D/H ratio must have survived the extensive late-stage aqueous processing. It is not in the case for OM in carbonaceous chondrites of which the D/H ratio was reduced by the alteration via the D-H exchange of water. It indicates that both the OM precursors and the water had high D/H ratios, similar to the water in Enceladus. Our results support the idea that the clast originated from Ceres, or at least, a hydrovolcanically active body similar to Ceres, and further imply that Ceres originally formed in the outer Solar System and migrated to the main belt asteroid region as suggested by the "Grand tack" scenario.

Kebukawa, Yoko↗

Laser Ablation Surface Treatment of Structural Aerospace Composites and Metal Alloys for Adhesive Bonding

NASA Langley Research Center (LaRC) has been involved over the past decade in the development of laser ablation as a method to surface treat aerospace structural fiber reinforced composites (CFRPs) and metal alloys. [1- 18] Laser surface treatment has been shown to be a rapid, high precision, and reproducible method for surface treatment of these materials, and is amenable to automation. The laser ablation process removes surface contamination such as silicones, creates surface roughness, and chemically activates a surface for bonding. The degree of ablation is controllable by adjusting laser parameters. In the case of CFRPs, ablation can be performed without damage to any underlying carbon fibers. In the case of metal alloys, ablation is possible without surface embrittlement, heat damage or creation of undesirable grain structures or morphologies. The optimum laser treatment conditions are substrate dependent and generally are influenced by laser wavelength and pulse duration (typically fixed for a laser system), and laser power. In the case of metal alloys such as Ti-6Al-4V, the laser ablation process eliminates the need for several steps of the conventional processes, including hydrofluoric (HF) acid and caustic treatment. These steps are often conducted in dip tanks and require costly facilities and environmentally unfriendly liquids. In addition, the laser can create nano-porosity on the Ti-6Al-4V alloy surface allowing for sol-gel penetration and thereby creating a gradient interface with improved temperature and mechanical performance. NASA LaRC has also been involved with the development of in-line characterization methods compatible with the laser treatment process to rapidly determine the presence of key contaminates such as silicones that, even at very low concentrations, are a threat to adhesive bonding. A spectroscopic technique called micro-laser induced breakdown spectroscopy (u-LIBS) has been developed to rapidly detect silicones at concentrations below those known to cause bonding problems. This technique requires no sample preparation, vacuum or inert atmosphere, has no practical size limitations, and provides nearly instantaneous feedback to the operator. This presentation will give an overview and update of these developments with specific examples highlighted.

Connell, John W.↗

A Novel Organic-Rich Meteoritic Clast from the Outer Solar System

The Zag meteorite which is a thermally-metamorphosed H ordinary chondrite contains a primitive xenolithic clast that was accreted to the parent asteroid after metamorphism. The cm-sized clast contains abundant large organic grains or aggregates up to 20 μm in phyllosilicate-rich matrix. Here we report organic and isotope analyses of a large (~10 μm) OM aggregate in the Zag clast. The X-ray micro-spectroscopic technique revealed that the OM aggregate has sp2 dominated hydrocarbon networks with a lower abundance of heteroatoms than in IOM from primitive (CI,CM,CR) carbonaceous chondrites, and thus it is distinguished from most of the OM in carbonaceous meteorites. The OM aggregate has high D/H and (sup 15)N/(sup 14)N ratios (δD = 2,370 ± 74‰ and δ(sup 15)N = 696 ± 100‰), suggesting that it originated in a very cold environment such as the interstellar medium or outer region of the solar nebula, while the OM is embedded in carbonate-bearing matrix resulting from aqueous activities. Thus, the high D/H ratio must have been preserved during the extensive late-stage aqueous processing. It indicates that both the OM precursors and the water had high D/H ratios. Combined with (sup 16)O-poor nature of the clast, the OM aggregate and the clast are unique among known chondrite groups. We further propose that the clast possibly originated from D/P type asteroids or trans-Neptunian Objects.

Yoko Kebukawa↗

Removing Contamination from Genesis Sapphire Collectors by Polishing

The Genesis Solar Wind Sample Re-turn Mission used a variety of materials as solar wind (SW) collectors. “Sapphire”, which is single crystal corundum, was ~6.7% of the collector material flown. But, a much higher percentage of Genesis sapphire collectors (SAP) survived the crash of the sample-return capsule as SAP is chemically inert, physically tough, and hard (MOHS 9, by definition). In fact, 39 sapphire fragments of bulk SW collector having areas ≥60 sq mm are available in JSC’s Genesis online catalog, whereas only 1 similarly sized silicon fragment is available (accessed 1/1/2020). In spite of the ease of accessing larger fragments, sapphire has not been popular among Genesis re-searchers because it is an electrical insulator (making SIMS more difficult) and its chemical inertness, high melting point and high hardness precludes the use of many mass-spectroscopic techniques. Recently, as alternative techniques for measuring Genesis samples are developed (e.g., synchrotron TXRF, INAA, laser ablation mass spectroscopy), more researchers are choosing to analyze sapphire. Thus, a number of researchers are actively studying how to best remove contamination from the Genesis sapphire surfaces. This report extends the task in Schmeling et al. that used polishing compounds to remove contamination from Genesis sapphire and focuses on contaminants (welded silicon, aluminum) that current chemical methods find recalcitrant.

M. Schmeling↗

Probing the Origin of the Open Circuit Voltage in Perovskite Quantum Dot Photovoltaics

Perovskite quantum dots (PQDs) have many properties that make them attractive for optoelectronic applications, including expanded compositional tunability and crystallographic stabilization. While they have not achieved the same photovoltaic (PV) efficiencies of top-performing perovskite thin films, they do reproducibly show high open circuit voltage (VOC) in comparison. Further understanding of the VOC attainable in PQDs as a function of surface passivation, contact layers, and PQD composition will further progress the field and may lend useful lessons for non-QD perovskite solar cells. Here, we use photoluminescence-based spectroscopic techniques to understand and identify the governing physics of the VOC in CsPbI3 PQDs. In particular, we probe the effect of the ligand exchange and contact interfaces on the VOC and free charge carrier concentration. The free charge carrier concentration is orders of magnitude higher than in typical perovskite thin films and could be tunable through ligand chemistry. Tuning the PQD A-site cation composition via replacement of Cs+ with FA+ maintains the background carrier concentration but reduces the trap density by up to a factor of 40, reducing the VOC deficit. These results dictate how to improve PQD optoelectronic properties and PV device performance and explain the reduced interfacial recombination observed by coupling PQDs with thin-film perovskites for a hybrid absorber layer.

perovskite quantum dot↗

Simulated Lunar Surface Hydration Measurements using Multispectral Lidar at 3 µm

Accurately measuring the variability of spectroscopic signatures of hydration (H2O + OH) on the illuminated lunar surface at 3 µm as a function of latitude, lunar time of day, and composition is crucial to determining the generation and destruction mechanisms of OH species and understanding the global water cycle. A prime complication in analysis of the spectroscopic feature is the accurate removal of thermal emission, which can modify or even eliminate the hydration feature depending on the data processing methods used and assumptions made. An orbital multispectral lidar, with laser illumination at key diagnostic wavelengths, would provide uniform, zero-phase geometry, complete latitude and time of day coverage from a circular polar orbit, and is agnostic to the thermal state of the surface. We have performed measurement simulations of a four-wavelength multispectral lidar using spectral mixtures of hydrated mid-ocean ridge basalt (MORB) glasses and lunar regolith endmembers to assess the lidar performance in measuring hydration signatures on the lunar surface. Our results show a feasible system with wavelengths at 1.5 µm, 2.65 µm, 2.8 µm, and 3.1 µm can measure lunar hydration with a precision of 52 ppm (1σ) or better. These results, combined with the uniform measurement capabilities of multispectral lidar make it a valuable spectroscopic technique for elucidating mechanisms of OH/H2O generation, migration, and destruction.

D. R. Cremons↗

Ramdb: The NASA Raman Spectral Database (version 1.00).

Given that, in most instances, minimal sample preparation is required and due to its contactless instrument design, Raman spectroscopy is one of the most versatile vibrational spectroscopic techniques for the chemical analysis of environmental and biological specimens. The diversity of applications of Raman spectroscopy ranges anywhere from art [1] to planetary science missions [2]. The advancement in the use of Raman spectroscopy in Solar System missions, notably in post-mission sample return analysis, requires a spectral library holding the broad range of specimens that could be found in Solar System sources. For this purpose, we have initiated the development of a Raman spectral database (Ramdb) at NASA Ames Research Center. Currently, the database includes experimental and theoretical Raman spectra of PAHs [3, 4], as well as laboratory Raman spectra of amino acids, carbon allotropes, minerals, and analogs relevance to Earth Sciences [5], Exobiology [6], Planetary [7], and Astrochemistry [8] to name just a few examples. Ramdb can be found on the web at www.astrochemistry.org/ramdb, where raw and processed Raman spectra can be downloaded in CSV format. The laboratory Raman spectra are measured using a laser Raman spectrometer (JASCO NRS-5500-532QRI). The Raman instrument is equipped with three excitation lasers, with wavelengths of 405, 532, and 785 nm. A clean silicon substrate is used as the internal standard for wavenumber calibration. Powdered samples were prepared (microscopic >10 um, grounded microscopic < 10 um) on glass slides. Some raw data exhibited a background signal arising as a combination of laser-induced fluorescence from the sample. To correct this background, we developed a Python pipeline that uses open-source Python libraries. Ramdb provides both raw and processed (using Python pipeline) data, which includes tabulated Raman shift transitions and other measurement details. The theoretical Raman band positions of PAHs (pyrene monomers and tetramer clusters) were computed using density functional theory (DFT) with the help of the Gaussian 16 suite of programs [9]. In the near future, Ramdb will serve as a repository of Raman spectral data from Laboratory Astrophysics and Planetary Science experiments involving the irradiation of organic compounds under simulated space and planetary conditions. In addition, online and offline tools will be developed for utilising the database for comparison to the user’s sample.

N Punnakayathil↗

Project 8: Measuring the tritium beta-decay spectrum using Cyclotron Radiation Emission Spectroscopy

Abstract. The goal of the Project 8 experiment is to measure the absolute neutrino mass using tritium beta decays and a new spectroscopic technique, Cyclotron Radiation Emission Spectroscopy (CRES). The first phase of Project 8 demonstrated that CRES could be used to detect single-electron cyclotron radiation and perform precision electron spectroscopy. We are in Phase II of the experiment, performing a 100-day measurement of the endpoint of the tritium spectrum. We will demonstrate the ability to measure the last ~2 keV of the beta-decay spectrum and explore the background rate at energies just above the endpoint; CRES has the potential for extremely low backgrounds. In Phase III we will demonstrate the ability to scale up the volume of the experiment. In Phase IV we will switch the source from molecular tritium to atomic tritium, which will avoid systematic uncertainties from the final states of the molecule. I will present the current status of Project 8 Phase II and the plans for Phases III and IV.

Oblath, Noah↗

Multivariate Linear Models for In Situ Monitoring of Low-Activity Nuclear Waste Using Infrared and Raman Spectroscopy - 20218

This paper presents the use of in situ monitoring tools for molecular analysis of non-radioactive species found in the supernatant liquid and dissolvable salt cake of nuclear waste at Hanford. We have selected two in situ spectroscopic techniques that do not require any sample preparation or consumables: infrared (in the form of attenuated total reflectance Fourier transform infrared or ATR-FTIR) and Raman spectroscopy. This work aims to evaluate their performance for liquid waste simulants representative of the Hanford DFLAW (Direct Feed Low-Activity Waste) feed. In addition, we have evaluated the performance of four multivariate linear models that extract concentrations from spectral measurements for a data set that was designed to include key molecular species found in liquid low-activity waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dissipation Enables Strongly Detuning-Dependent Interference in Pulsed Dynamical Decoupling

One of the defining features of pulsed dynamical decoupling is its suppression of a driven qubit's sensitivity to static detuning errors between the drive field and qubit resonance. In this paper, we show that dissipation, in the form of excited-state decay, can change this behavior entirely, producing an interference signal with a strong detuning dependence. This signal arises from decay during driven evolution and relies on coherence retained by the qubit after such a decay event. We develop analytical and numerical models that capture the underlying mechanism and observe this same dissipation-induced detuning dependence experimentally in both a free-space strontium atom interferometer and a superconducting transmon qubit system. We also use this dissipation-induced detuning dependence as the basis for a new spectroscopic technique called Dissipative Carr-Purcell Spectroscopy (DCPS) and compare it with a traditional Ramsey sequence. Our results establish a regime of pulsed dynamical decoupling in which dissipation reshapes, rather than merely degrades, coherent control, and we expect these dynamics to be relevant to a wide range of quantum systems.

DeRose, Kenneth [Northwestern U.; Fermilab] (ORCID↗

Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

Fluorescence↗

Picosecond lifetime measurements of resonances using a thick-target invariant-mass technique

Here, a new technique is presented for measuring the half-lives of resonances in the picosecond range using presently available invariant-mass apparatus and a thick target. For short-lived resonances, the energy losses of the decay fragments in the target material change their relative velocities giving rise to a poor invariant-mass resolution. However, for longer-lived resonances that travel through the remaining target material before decaying outside of the target, this dominant contribution to the resolution is eliminated. The measured invariant-mass peak will then display a narrow peak from these events which sits on a wider structure associated with the remaining events that decay in the target. The fraction of the events in the narrow peak is related to the probability that the resonance leaves the target before decaying and hence is related to the lifetime. This technique is exercised for the 2.685-MeV resonance in 33 Cl which decays by emitting an f -wave proton. A half-life of T 1/2 =5.7$^{+4.1}_{-2.5}$ ps was measured which is consistent with values inferred from other known properties of this resonance.

lifetimes & widths↗