Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Data collection in IMS: It's not as easy as it looks

Data collection in Ion Mobility Spectrometry (IMS) is not as easy an endeavor as it appears. Despite the advent of high speed personal computers and fast analog-to-digital converters (ADC's), care must be taken to ensure that reliable data are obtained in a timely fashion. This is especially true in hyphenated techniques, e.g. GC-IMS, where the amount of data increases dramatically when gas chromatography-ion mobility spectrometry (GC-IMS) data is being collected. Using the Graseby GC-IMS, with a gate repetition rate of 33 Hz, it is theoretically possible to collect 33 spectra per second. This collection rate is not realistically obtained due to a number of factors. Among these factors are inaccuracy of the timing signal from the IMS, the necessity to store the data, disk input/output limitations, disk operating system limitations, and program overhead. Taking these factors into account, we have achieved a data collection rate of 20 spectra per second. This paper will describe these problems, demonstrate the practical effects these problems present, and present methods for minimizing these effects.

Davis, Dennis M.↗

Detecting and Removing Data Artifacts in Hadamard Transform Ion Mobility-Mass Spectrometry Measurements

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that both fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm uses knowledge of the true signal peaks derived from the encoded data and allows for both artifacts and noise to be removed with high confidence, decreasing the likelihood of false identifications in subsequent data processing. The result is that IMS-MS can be applied to increase measurement sensitivity while avoiding artifacts that have previously limited its utility.

47 OTHER INSTRUMENTATION↗

SPRUCE Advanced Molecular Techniques Provide a Rigorous Method for Characterizing Organic Matter Quality in Complex Systems: Supporting Data

This dataset contains Fourier transform ion cyclotron resonance mass spectrometry-based measurements (FTICRMS), gas chromatography, and liquid chromatography data from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA from 2011 to 2016. Measurement results demonstrate that optical characterization of peatland dissolved organic matter (DOM) may not fully capture classically identified chemical characteristics and may, therefore, not be the best measure of organic matter quality. Analyses show poor regression fits between optical characteristics and Fourier transform ion cyclotron resonance mass spectrometry-based measurements (FTICRMS). These data were used in Wilson and Tfaily (2018) and files are organized by which figure they were used to produce. Data underlying those regression analyses, as shown in Figures 1a and 1b of Wilson and Tfaily (2018), are provided in data files ds01 and ds02, respectively. ds01: Optically-derived specific ultraviolet absorbance method at 254 nm (SUVA254) values and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) -derived double bond equivalences. ds02: Optically-derived spectral slopes and FTICRMS-derived average molecular weights. Results of analyses of a representative sample by FTICRMS and additional analytical techniques provide a broader picture of the compounds occurring in peatland dissolved organic matter (DOM) as shown in Figure 2 of Wilson and Tfaily (2018). The data underlying Figure 2 in are provided in data files ds03-ds07, organized by the respective analytical technique used to generate the data. ds03: Nitrogen containing compounds identified via FTICRMS. ds04: Compounds identified via FTICRMS which did not have nitrogen. ds05: Nuclear magnetic resonance (NMR) results. ds06: Gas chromatography mass spectrometry (GCMS) results. ds07: Liquid chromatography mass spectrometry (LCMS) results. This dataset contains seven data files in comma-separate values (*.csv) format. Additional metadata are provided: seven data dictionaries and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format.

54 ENVIRONMENTAL SCIENCES↗

Interactive XCMS Online: Simplifying Advanced Metabolomic Data Processing and Subsequent Statistical Analyses

XCMS Online (xcmsonline.scripps.edu) is a cloud-based informatic platform designed to process and visualize mass-spectrometry-based, untargeted metabolomic data. Initially, the platform was developed for two-group comparisons to match the independent, “control” versus “disease” experimental design. Here, we introduce an enhanced XCMS Online interface that enables users to perform dependent (paired) two-group comparisons, meta-analysis, and multigroup comparisons, with comprehensive statistical output and interactive visualization tools. Newly incorporated statistical tests cover a wide array of univariate analyses. Multigroup comparison allows for the identification of differentially expressed metabolite features across multiple classes of data while higher order meta-analysis facilitates the identification of shared metabolic patterns across multiple two-group comparisons. Given the complexity of these data sets, we have developed an interactive platform where users can monitor the statistical output of univariate (cloud plots) and multivariate (PCA plots) data analysis in real time by adjusting the threshold and range of various parameters. On the interactive cloud plot, metabolite features can be filtered out by their significance level (p-value), fold change, mass-to-charge ratio, retention time, and intensity. The variation pattern of each feature can be visualized on both extracted-ion chromatograms and box plots. The interactive principal component analysis includes scores, loadings, and scree plots that can be adjusted depending on scaling criteria. The utility of XCMS functionalities is demonstrated through the metabolomic analysis of bacterial stress response and the comparison of lymphoblastic leukemia cell lines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Respiration data, microbial community assembly data, and FTICR-MS data associated with: “Disturbance Triggers Non-Linear Microbe-Environment Feedbacks. Sengupta et al., 2021, Biogeosciences”

This data package is associated with the manuscript “Disturbance Triggers Non-Linear Microbe-Environment Feedbacks, in revision in Biogeosciences (Sengupta et al. and 2021;https://bg.copernicus.org/preprints/bg-2021-51/). The study used hyporheic zone sediments as a model system to provide an integrated view of how disturbance modulates linkages among microbial ecology, biogeochemistry, and organic matter thermodynamics. Laboratory experiments exposed hyporheic sediment to varying wetting/drying dynamics. Data types include dissolved oxygen rates used to derive respiration rates, Fourier-transform ion cyclotron resonance mass spectrometry (FTICR-MS) data used to derive thermodynamic properties of organic matter, and microbial community assembly metrics derived from amplicon-sequence data of putatively active (cDNA) and whole community (gDNA). The outcomes of the study are condensed into a broadly applicable conceptual model linking external forcing, internal dynamics, and history. This data package is comprised of a file-level metadata (FLMD) csv, metadata csv, and seven folders that contain csv files, R scripts, xml files, and associated documentation: (1) Rates, (2) bNTI, and (3) FTICR, (4) Statistics_Analyses, (5) Raw OTU Beta dispersion Analysis, (6) bMNTD Randomizations, and (7) Data Dictionaries. The FLMD file has a description of each file included in the data package.

54 ENVIRONMENTAL SCIENCES↗

The incongruity of validating quantitative proteomics using western blots

Similar to the age-old reviewer request for quantitative PCR validation of RNA sequencing data, nearly every researcher using proteomics technologies has, at one time or another, been asked by a reviewer to provide “western blot validation” of their mass spectrometry-based protein abundance data. We believe this request demonstrates a lack of awareness amongst the plant biology community about the extraordinary improvements in cost, sensitivity and reliability the field of mass spectrometry-based proteomics has made in recent years. Here, in this study, as a group of experts in different domains of quantitative plant proteomics, we explain why “western blot validation” of quantitative proteomics data is both unnecessary and invalid. Furthermore, we invite our colleagues in the plant science community to update their perception of quantitative mass spectrometry as a sensitive and reliable method of protein identification and quantitation.

Mehta, Devang↗

A mass graph-based approach for the identification of modified proteoforms using top-down tandem mass spectra

Motivation: Although proteomics has rapidly developed in the past decade, researchers are still in the early stage of exploring the world of complex proteoforms, which are protein products with various primary structure alterations resulting from gene mutations, alternative splicing, post-translational modifications, and other biological processes. Proteoform identification is essential to mapping proteoforms to their biological functions as well as discovering novel proteoforms and new protein functions. Top-down mass spectrometry is the method of choice for identifying complex proteoforms because it provides a “bird’s eye view” of intact proteoforms. The combinatorial explosion of various alterations on a protein may result in billions of possible proteoforms, making proteoform identification a challenging computational problem. Results: We propose a new data structure, called the mass graph, for efficient representation of proteoforms and design mass graph alignment algorithms. We developed TopMG, a mass graph-based software tool for proteoform identification by top-down mass spectrometry. Experiments on top-down mass spectrometry data sets showed that TopMG outperformed existing methods in identifying complex proteoforms.

Dynamic Programming↗

Improved Quantitative Dynamic Range of Time-of-Flight Mass Spectrometry by Simultaneously Waveform-Averaging and Ion-Counting Data Acquisition

Two different types of data acquisition methods, “averaging mode” and “ion-counting mode”, have been used in a time-of-flight (TOF) mass spectrometry. The most common method is an averaging mode that sums waveform signals obtained from each flight cycle. While it is possible to process many ions arriving at the same TOF in one flight cycle, low-abundance ions are difficult to measure because ion signals are overwhelmed by noises from the detection system. An ion-counting mode is suitable for the detection of such low-concentration ions, but counting loss occurs when two or more ions arrive at the detector within the dead time of the acquisition system. In this study, we introduce a technique that combines two methods to measure target ions with a high concentration difference, i.e., averaging mode and ion-counting mode are used simultaneously for high abundant and trace ions, respectively. By processing waveforms concurrently during data acquisition, one can choose to analyze either or both types of data to achieve a highly quantitative mass spectrum over a wide range of sample concentrations. The result of the argon isotope analysis shows that this method provides a more accurate determination of the isotope ratio compared to averaging mode alone at one-twentieth of the analysis time required by ion-counting alone. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic Matter Concentration and Composition in November 2021 and April 2022 from 12 Streams Impacted by the 2020 Holiday Farm Fire (v2)

This dataset represents results from a field study aiming to understand storm induced transport of pyrogenic materials to streams impacted by varying degrees of burn severity. Time series samples were collected at 5 sites within the McKenzie River Watershed (Oregon, USA) whose catchment were each completely engulfed by the 2020 Holiday Farm Fire. An additional 7 sites were sampled once during the storm. The samples were collected during storm events in November 2020, January 2021, November 2021, and April 2022. Samples were characterized for benezenepolycarboxylic acids (BPCA), ultra-high resolution mass spectrometry, dissolved organic carbon and optics (absorbance and fluorescence). Fourier-transform ion cyclotron resonance mass spectrometry (FTICR) and dissolved organic carbon data from the November 2020 (referred to as “EWEB_2020”) sampling can be found in a separate data package (doi: 10.15485/1869708). NOTE: The 2020 samples were run on FTICR-MS in two unique instances. The first run can be found in the previous data package (EWEB_2020). The second run is included in this data package. These samples were run for a second time so that the data were more directly interoperable with the other samples in this data package. We have not done any investigation into the differences/similarities between these datasets and the previously ran/published data in the other data package. This data package was originally published in November 2024. It was updated in April 2025 (v2; new and modified files). See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data; (7) excitation emission matrix (EEM) methods; and (8) a sub-folder with processed EEM data (9) benzene polycarboxylic acid (BPCA) concentration data; (10) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; and (11) folder of high-resolution characterization of organic matter via 12 Tesla FTICR-MS generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The EEMs sub-folder contains two additional folders; the Absorbance and Fluorescence folders which contain the processed EEMs absorbance and fluorescence data respectively. This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

Surface water and groundwater FTICR-MS, NPOC, and TN from nine wetlands and three upland wells at the Tanglewood Biological Station, Alabama

This dataset supports a broader study examining wetland hydrobiogeochemical responses to flood disturbance and the subsequent impacts on watershed nutrient export. The study was designed following ICON (integrated, coordinated, open, and networked) principles. Samples were collected from nine wetlands and three upland wells at the Tanglewood Biological Station, Alabama in August 2024 and February 2025, during the dry and wet season, respectively. The contents include geochemistry (dissolved organic carbon measured as non-purgeable organic carbon; total dissolved nitrogen) and organic matter characterization (FTICR-MS). Related water level data from the same locations can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/2530253. Additional geochemistry will be published in a separate data package. For details on how to navigate this data package, see this infographic from the River Corridor SFA https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions.This dataset is comprised of (1) a folder containing environmental context photos; (2) file-level metadata; (3) data dictionary; (4) field metadata; (5) readme; (6) international generic sample number (IGSN) mapping file; (7) the field protocol; and (8) a subfolder with sample data. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total nitrogen data and averages; (3) methods codes; and (4) a subfolder of 12 Tesla (12T) Fourier-transform ion cyclotron resonance mass spectrometry (FTICR-MS) data. All files are .csv, .pdf, .jpeg, or .jpg.

54 ENVIRONMENTAL SCIENCES↗

Increasing the Scale of the Mass Spectrometry Query Language Compendium with Explainable AI

A significant bottleneck in metabolomics data interpretation is the effective use of domain knowledge to assign structural information based on fragmentation patterns. The mass spectrometry query language (MassQL) aims to make this process accessible and applicable across multiple analysis platforms. While advanced computational methods are capable of predicting compound structures from fragmentation data, AI/ML approaches often rely on complex, opaque criteria that are difficult to interpret or modify. As a result, their predictive patterns cannot be readily translated into human-readable rules, such as those used in MassQL. Here, in this study, we introduce ChemEcho, a machine learning embedding method that converts tandem mass spectrometry data into sparse feature vectors containing peak and neutral mass subformulae to enhance explainable AI/ML-based methods. An advantage of this approach is that decision trees trained using these feature vectors can be directly translated to MassQL. Using a battery of decision trees trained using ChemEcho embeddings to predict molecular attributes, we generated over 1500 MassQL queries for 765 molecular features and evaluated their precision and recall. From these queries, the 50 highest-performing queries were integrated into the MassQL compendium. This set of generated MassQL queries included environmentally and biologically relevant classes such as PFAS and molecules containing phosphate or sulfate substructures. To illustrate the impact these queries would have on a typical metabolomics experiment, these MassQL queries were applied to a public metabolomics data set─resulting in a marked increase in the structural information derived from tandem mass spectra. Access and reuse of these queries is expected to enhance structural annotation in untargeted experiments, leading to more specific claims and advancing many applications in metabolomics.

Harwood, Thomas V. [USDOE Joint Genome Institute (↗

Surface Induced Dissociation Coupled with High Resolution Mass Spectrometry Unveils Heterogeneity of a 211 kDa Multicopper Oxidase Protein Complex

Manganese oxidation is an important biogeochemical process that is largely regulated by bacteria through enzymatic reactions. However, the detailed mechanism is poorly understood due to challenges in isolating and characterizing these unknown enzymes. A manganese oxidase, Mnx, from Bacillus sp. PL-12 has been successfully overexpressed in active form as a protein complex with a molecular mass of 211 kDa. We have recently used surface induced dissociation (SID) and ion mobility-mass spectrometry (IM-MS) to release and detect folded subcomplexes for determining subunit connectivity and quaternary structure. The data from the native mass spectrometry experiments led to a plausible structural model of this multicopper oxidase, which has been difficult to study by conventional structural biology methods. It was also revealed that each Mnx subunit binds a variable number of copper ions. Becasue of the heterogeneity of the protein and limited mass resolution, ambiguities in assigning some of the observed peaks remained as a barrier to fully understanding the role of metals and potential unknown ligands in Mnx. In this study, we performed SID in a modified Fourier transform-ion cyclotron resonance (FTICR) mass spectrometer. The high mass accuracy and resolution offered by FTICR unveiled unexpected artificial modifications on the protein that had been previously thought to be iron bound species based on lower resolution spectra. Additionally, isotopically resolved spectra of the released subcomplexes revealed the metal binding stoichiometry at different structural levels. This method holds great potential for in-depth characterization of metalloproteins and protein–ligand complexes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory time series moisture manipulative experiment from sediment across the contiguous US: time series aerobic respiration and geochemistry (v2)

This dataset supports a broader study examining the effects of wetting and drying on hyporheic zone respiration across the contiguous United States (CONUS). The dataset provides data generated from a laboratory moisture manipulation experiment. The contents include time series aerobic respiration and moisture; dissolved oxygen; sediment geochemistry data; and field metadata (including qualitative information on instream and river corridor characteristics). Samples were collected as part of the WHONDRS CONUS-Scale Model-Sample Study (CM). This study was designed following ICON (integrated, coordinated, open, and networked) principles to facilitate a model-experiment (ModEx) iteration approach, leveraging crowdsourced sampling across the CONUS. The data package associated with the CM study is available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689. CM sampling began in April 2022 and ended in October 2023. This study uses subsamples from a subset of CM samples collected between June 2022 and June 2023. The original field samples were labeled as CM_###. Subsequent subsamples for this study were labeled as EC_###. The labels from the field samples and the EC subsamples can be mapped directly based on the digits following the prefix and underscore (i.e., EC_001 is a subsample from CM_001). See the critical details section below for more details on sample naming. This data package was originally published in August 2024. It was updated in February 2026 (v2; new and modified files). See the change history section in the readme for more details. For details on how to navigate this data package, see this infographic from the River Corridor SFA https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) field protocol; and a (6) a subfolder with sediment sample data from the incubation experiment. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC); (2) total nitrogen (TN); (3) adenosine triphosphate (ATP); (4) percent carbon and nitrogen; (5) effect size; (6) iron (II); (7) gravimetric moisture; (8) respiration rates and raw dissolved oxygen values; (9) specific conductance; (10) pH; (11) temperature; (12) a summary containing median values of each data type for each treatment (wet and dry); (13) methods codes; (14) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla FTICR-MS data. This folder contains three subfolders, one containing the sediment .xml data files, one containing the sediment CoreMS output files, the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .ref, or .xml.

54 ENVIRONMENTAL SCIENCES↗

Bayesian Statistical Analysis for Mass Spectrometric Data Processing

• Thermal ionization mass spectrometry (TIMS) is a “gold standard’ technique for actinide isotope amount ratio and assay measurements. • Ubiquitously used in: • Nuclear Nonproliferation • Nuclear Safeguards • Nuclear Forensics • Basic Science • Savannah River National Laboratory (SRNL) installed a new Thermo Scientific TRITON Plus TIMS in early 2024.

McLarty, Ellis C. [Savannah River National Laborat↗

Bayesian Statistical Analysis for Mass Spectrometric Data Processing

Thermal ionization mass spectrometry (TIMS) is a “gold standard’ technique for actinide isotope amount ratio and assay measurements. • Ubiquitously used in: • Nuclear Nonproliferation • Nuclear Safeguards • Nuclear Forensics • Basic Science • Savannah River National Laboratory (SRNL) installed a new Thermo Scientific TRITON Plus TIMS in early 2024.

McLarty, Ellis C. [Savannah River National Laborat↗

Data and scripts associated with the manuscript "Organic Molecules are Deterministically Assembled in River Sediments"

This data package is associated with the publication "Organic Molecules are Deterministically Assembled in River Sediments" submitted to Scientific Reports (Stegen et al., 2024). The study applies community ecology methods to dissolved organic matter (DOM) chemistry from variably inundated riverbed sediments to uncover principles governing DOM composition at a reach-scale. This data package documents the workflow used to process and generate the main findings in the manuscript. The R scripts reference the raw, unprocessed Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data from another data package, available on ESS-DIVE at https://data.ess-dive.lbl.gov/view/doi:10.15485/1834208. The scripts then process the raw FTICR-MS data and generate the findings and figures presented in the associated manuscript. In brief, this study demonstrates that DOM assemblages in variably inundated sediments are primarily governed by deterministic variable selection, including sediment moisture effecting the degree of deterministic assembly. See the manuscript for more details pertaining to interpretation and implications of the findings. This data package is associated with the GitHub repository found at https://github.com/WHONDRS-Hub/ECA_2020_Sed.This data package is comprised of 6 scripts and 7 folders. The file-level metadata file (file ending in "flmd.csv") lists all files contained in this data package and descriptions for each. The data dictionary (file ending in "dd.csv) describes all tabular data columns and their respective definitions and units. The FTICR_Processing_Scripts produce the outputs found in the "Processed_Data" folder. The remaining scripts (located in the parent directory) produce the outputs found in the following four folders: (1) "MCD_Dendrograms", "MCD_Randomizations", "MCD_bNTI_Outcomes", and "OM_Null_Modeling". The fifth script additionally takes the three comma-separated values (CSV) files found in the parent directory as input ("VGC_texture.csv", "merged_weights.csv", and "ECA2_FTICR_BetaDisp.csv"). The outputs of each of the five scripts serve as the input to the following script, with the final outputs stored in the folder "OM_Null_Modeling".

54 ENVIRONMENTAL SCIENCES↗

Time sequence determination of parent–daughter radionuclides using gamma-spectrometry

The acquisition of time-stamped list (TLIST) data provides additional information useful to gamma-spectrometry analysis. A novel technique is described that uses non-linear least-squares fitting and the Levenberg-Marquardt algorithm to simultaneously determine parent-daughter atoms from time sequence measurements of only the daughter radionuclide. This has been demonstrated for the radioactive decay of short-lived radon progeny (214Pb/214Bi, 212Pb/212Bi) described using the Bateman first-order differential equation. The calculated atoms are in excellent agreement with measured atoms, with a difference of 1.3 – 4.8% for parent atoms and 2.4% - 10.4% for daughter atoms. Measurements are also reported with reduced uncertainty. The technique has potential to redefine gamma-spectrometry analysis.

Burnett, J. L. (ORCID:0000000322586252)↗