Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Sandia NRT Blade-0 Laboratory Modal Survey

Modal testing was performed on the Sandia NRT Blade-0 in building A-60 at NREL/NWTC. Modal testing was intended to identify the fundamental frequencies of the blade. The blade was cantilevered to the A-60 test stand. Fundamental frequencies were identified using impact modal testing. Additional tests included free-decay testing to quantify damping at small displacements. Small-displacement modal testing aims to minimize the influence of aerodynamic damping; roaming accelerometer impact testing with the development of a dynamic frame model enabled visualization of mode shapes.

17 WIND ENERGY↗

In-flight positional and energy use data set of a DJI Matrice 100 quadcopter for small package delivery

Abstract We autonomously directed a small quadcopter package delivery Uncrewed Aerial Vehicle (UAV) or “drone” to take off, fly a specified route, and land for a total of 209 flights while varying a set of operational parameters. The vehicle was equipped with onboard sensors, including GPS, IMU, voltage and current sensors, and an ultrasonic anemometer, to collect high-resolution data on the inertial states, wind speed, and power consumption. Operational parameters, such as commanded ground speed, payload, and cruise altitude, were varied for each flight. This large data set has a total flight time of 10 hours and 45 minutes and was collected from April to October of 2019 covering a total distance of approximately 65 kilometers. The data collected were validated by comparing flights with similar operational parameters. We believe these data will be of great interest to the research and industrial communities, who can use the data to improve UAV designs, safety, and energy efficiency, as well as advance the physical understanding of in-flight operations for package delivery drones.

42 ENGINEERING↗

Design, Manufacturing, and Validation of an Optimized Electric Machine Enabled by 3D Printing

The collaboration between the National Laboratory of the Rockies (NLR) and LaunchPoint Electric Propulsion Solutions, Inc. (LaunchPoint) focuses on manufacturing and additive design of electric machines enabled by DOE’s program for three-dimensional printing (MADE3D) as applied to advanced drivetrains and their impact on turbine capital cost and lifetime energy production. Initial efforts will focus on the rotor structure and rotor core of the drivetrain including the active materials (electrical steel and magnets) and could later expand to the stator. The verification activities will be conducted with an instrumented electric machine and a small dynamometer.

17 WIND ENERGY↗

AmeriFlux FLUXNET-1F US-Me2 Metolius mature ponderosa pine

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Me2 Metolius mature ponderosa pine. This is the FLUXNET version of the carbon flux data for the site US-Me2 Metolius mature ponderosa pine produced by applying the standard ONEFlux (1F) software. Site Description - Site Description before Fire (January, 2002 - August, 2020): The mean stand age is 71 years old and the stand age of the oldest 10% of trees is about 108 years old. This site is one of the Metolius core cluster sites with different age and disturbance classes and part of the AmeriFlux network. The overstory is almost exclusively composed of ponderosa pine trees (Pinus ponderosa Doug. Ex P. Laws) with a few scattered incense cedars (Calocedrus decurrens (Torr.) Florin) and has a peak leaf area index (LAI) of 2.1 m2 m-2. Tree height is relatively homogeneous at about 18 m, and the mean tree density is approximately 339 trees ha-1 (Irvine et al., 2008). The understory is sparse with an LAI of 0.2 m2 m-2 and primarily composed of bitterbrush (Purshia tridentata (Push) DC.) and greenleaf manzanita (Arctostaphylos patula Greene). Soils at the site are sandy (69%/24%/7% sand/silt/clay at 0–0.2 m depth and 66%/27%/7% at 0.2–0.5 m depth, and 54%/ 35%/11% at 0.5–1.0 m depth), freely draining with a soil depth of approximately 1.5 m (Irvine et al., 2008; Law et al., 2001b; Schwarz et al., 2004). Green Ridge Fire: On August 20, 2020, the Green Ridge Fire burned through Us-Me2. The fire was ignited by lightning on August 16th, and grew rapidly to the east over the first few days driven by strong, downslope (westerly) afternoon winds. Fire behavior and observed fire effects were highly heterogeneous due to the localized wind pattern carrying the flaming head of the fire forward, and the efforts being made by suppression resources to contain the fire. The site experienced the full range of fire effects, from <1 m high surface fire that charred litter and duff and only consumed shrubs and herbaceous material to full tree (>15 m) crown fire that consumed 100% of needles, small limbs, and surface fuels at high intensity, leaving only ash and bare soil post-fire. Salvage Logging: From late March to late April 2021, salvage logging by the landowner occurred at the site. Almost all trees within the flux footprint were logged except a small area with lower burn severity, where sap flow and automatic soil respiration measurements are continued since the fire. In August 2022 the primary flux system was moved from the top of the damaged tall tower to a nearby shorter tower centering on the salvage/regenerating footprint.

Hanson, Chad↗

Comprehensive assessment of deep reinforcement learning approaches for economic dispatch in nuclear-driven microgrids

As the electrical grid integrates more variable renewable energy sources such as wind and solar, the demand for distributed and flexible systems to address this increased variability becomes critical. Nuclear-driven microgrids provide a promising solution by offering stable generation to complement intermittent renewables, ensuring grid reliability and operating efficiency. This paper proposes a recurrent deep reinforcement learning framework for optimal economic dispatch in a nuclear-powered microgrid integrating renewable energy sources, small modular reactors, battery storage systems, and balance-of-plant dynamics. A three-agent control architecture is developed, where demand and renewable energy agents act as forecasters, and a reinforcement learning-based dispatch agent performs real-time energy allocation. A nonlinear programming formulation is first used to generate an optimal baseline for benchmarking. The proposed dispatch controller, based on Proximal Policy Optimization enhanced with Long Short-Term Memory networks, exploits temporal correlations in system dynamics by taking advantage of the time series used as inputs to improve policy robustness under uncertainty. Comparative analysis against established deep reinforcement learning methods, including Proximal Policy Optimization with a feedforward architecture, Soft Actor-Critic, and Twin Delayed Deep Deterministic Policy Gradient, demonstrates superior performance. Numerical results indicate that the proposed controller achieves a 0.39% cost reduction relative to the nonlinear programming benchmark and outperforms other learning-based methods by generating additional revenue of up to 0.35%. All reinforcement learning controllers compute dispatch actions in less than 0.3 s, resulting in a computational speedup of more than three orders of magnitude over the nonlinear programming baseline. The findings of this paper highlight their applicability for real-time operation and control in nuclear-integrated microgrids under volatile operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Unprecedented Beaufort Sea ice loss in late summer 2021 and its relationship to an extended period of unusually stormy weather

Previous case studies have linked cyclone-induced atmospheric forcing and/or upper-ocean processes to notable Arctic sea ice loss events in the summers of 2012 and 2016. This study examines a more recent and noteworthy case in late summer 2021 in which substantial sea ice loss followed a period of surface meteorological extremes in the Beaufort Sea region of the Arctic. We focus on the period from mid-August to mid-September 2021 that coincided with the Office of Naval Research THINICE Pilot Field Campaign and investigate stormy and windy conditions with respect to air-sea processes impacting sea ice conditions. We find that during the stormy first half of the campaign, cyclone-induced energy fluxes into the marginal ice zone and surrounding waters preconditioned the ice pack for more rapid melt later in the campaign. The second half of the campaign, in contrast, was marked by non-cyclone wind events that enhanced turbulent (namely sensible) heat fluxes into the ice and upper ocean that increased melt. Moreover, this latter period had enhanced advection of the Beaufort Sea ice pack into above-freezing waters, increasing bottom melt to >1 cm d −1 over the remainder of the campaign. While findings are shown to vary by surface type and at relatively small (i.e. ice-floe) scales, insights are offered on the roles of late summer coupled processes on rapid ice loss events in today’s Arctic environment.

54 ENVIRONMENTAL SCIENCES↗

Spatial patterns of snow distribution in the sub-Arctic

Abstract. The spatial distribution of snow plays a vital role in sub-Arctic and Arctic climate, hydrology, and ecology due to its fundamental influence on the water balance, thermal regimes, vegetation, and carbon flux. However, the spatial distribution of snow is not well understood, and therefore, it is not well modeled, which can lead to substantial uncertainties in snow cover representations. To capture key hydro-ecological controls on snow spatial distribution, we carried out intensive field studies over multiple years for two small (2017–2019; ∼ 2.5 km2) sub-Arctic study sites located on the Seward Peninsula of Alaska. Using an intensive suite of field observations (> 22 000 data points), we developed simple models of the spatial distribution of snow water equivalent (SWE) using factors such as topographic characteristics, vegetation characteristics based on greenness (normalized different vegetation index, NDVI), and a simple metric for approximating winds. The most successful model was random forest, using both study sites and all years, which was able to accurately capture the complexity and variability of snow characteristics across the sites. Approximately 86 % of the SWE distribution could be accounted for, on average, by the random forest model at the study sites. Factors that impacted year-to-year snow distribution included NDVI, elevation, and a metric to represent coarse microtopography (topographic position index, TPI), while slope, wind, and fine microtopography factors were less important. The characterization of the SWE spatial distribution patterns will be used to validate and improve snow distribution modeling in the Department of Energy's Earth system model and for improved understanding of hydrology, topography, and vegetation dynamics in the sub-Arctic and Arctic regions of the globe.

54 ENVIRONMENTAL SCIENCES↗

MLBS field profiling lidar

The field profiling lidar #ZX300-1945 was deployed in a small open clearing at the Mountain Lake Biological Station and is co-located with the University of Virginia scanning lidar. The zip files contain high frequency data. The Excel files are 10-min averages.

17 WIND ENERGY↗

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

Land of Opportunity: Potential for Renewable Energy on Federal Lands

Renewable energy (RE) in the United States has historically been deployed primarily on private lands, but the growing interest in RE development, generally across the country and specifically on federal lands, raises questions about the potential for RE on public lands. This study seeks to estimate RE technical potential on federal lands and project the amount of RE to be developed on federal lands under decarbonization scenarios for the contiguous United States. The study applied a combination of high-resolution geospatial analysis and power sector modeling and relied on multiple partner federal agencies and land administrators from the Bureau of Land Management, the U.S. Fish and Wildlife Service, the U.S. Forest Service, the U.S. Department of Defense, and the U.S. Department of Energy. In our reference siting access case, we estimate 44 million acres of federal land across the contiguous United States is potentially suitable for UPV development, which corresponds to a capacity technical potential of 5,750 gigawatts (GW) (Figure ES-1). Federal land area available for wind development is similar to UPV but wind’s generating capacity technical potential is lower (875 GW). The technical potential is estimated for two geothermal technologies, hydrothermal and enhanced geothermal systems (EGS), both of which have a smaller amount of federal land available for development (12 and 27 million acres, respectively). However, in terms of capacity, the technical potential for EGS (975 GW) is approximately equal to wind’s technical potential and there is an estimated 130 GW of hydrothermal potential. We also developed cases with more-limited land available for UPV and wind (for federal and non-federal lands) resulting in 96% reduction of wind capacity potential and 70% reduction for UPV. In a case with additional constraints applied to non-federal lands only (Limited Private), the overall (federal and non-federal) technical potential declines but the share of that technical potential on federal lands is higher than in the other siting cases. The technical potential is the maximum amount that could be developed, but only a small fraction would be developed or needed in the future. Across seven scenarios that achieve 100% carbon-free electricity by 2035, we estimate 26 GW to 270 GW of RE capacity could be deployed on federal lands by 2035. The three central scenarios have 51–84 GW of RE deployed by 2035 and requiring about 500,000 to 1,000,000 acres of total land area. Direct land consumption is less than total land use required, thus enabling co-use opportunities. The large technical potential estimates and the increasing deployment projections from the collection of scenarios show the opportunities for RE development on federal lands. Capturing these opportunities-while minimizing conflicts with other land uses, federal department or agency missions, and public interest, and simultaneously maximizing the economic, grid, and social value of the projects-would require collaborative planning among federal land administrators, grid planners, project developers, the public, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Drop C: The Drop-In, Ring-of-Power Heliostat (Final Report)

This report summarizes the work performed within the Drop-C: The Drop-In, Ring-of-Power Heliostat project. The Drop-C project aimed to develop a novel heliostat with an installed cost of $\$50$/m 2 ($\$2015$) which is a drastic cost reduction compared to the state-of-the-art. The resulting 27m 2 SunRing TM heliostat’s relative small size necessitates the parallel development of a wireless solar field network and a rapid calibration system. The SunRing heliostat is an evolution of the Ring-of-Power (ROP) design from Abengoa Solar LLC which had a reported installed cost of $114/m 2 . Cost savings relative to the ROP were sought by increasing the mirror area, improving the structural efficiency, a more accurate assessment of wind loads, and an improved assembly and installation procedure. The project spanned three Budget Periods (BP) where a digital heliostat was developed in BP1 using wind tunnel testing to define load conditions.

14 SOLAR ENERGY↗

Why Are There so Few Reports of High-Energy Electron Drift Resonances? Role of Radial Phase Space Density Gradients

Models of monochromatic Pc5 (2–7 mHz) ultralow frequency (ULF) wave interactions with high energy (greater than ~1 MeV) electrons predict drift resonant interactions that can cause rapid radial transport and acceleration. There are few reports of electron drift resonance at energies greater than ~1 MeV, in contrast to lower energies; moreover, all previous reports occur in the aftermath of interplanetary shocks. These two facts are difficult to reconcile with theory and numerical simulations predicting that greater than ~1 MeV drift resonances should occur more often and in a wider variety of driving conditions. In this study, we show that a combination of observational sampling biases and nominal radial phase space density gradients is one explanation for this discrepancy between theory and observations. In particular, we examine electron dynamics in two case studies with very similar satellite coverage, solar wind conditions, and Pc5 wave properties, yet with different radial phase space density profiles. Using global wave and particle observations, we show that the events have vastly different particle responses despite having similar wave properties. Placing these results in context with past studies, we further show here that nominal radial PSD gradients near geostationary orbit can mask the expected drift resonance particle response and explain (1) the small number of past greater than ~1 MeV drift resonance reports and (2) the restriction of these reports to interplanetary shock events. We argue that future observational studies characterizing radial transport via drift resonance should examine global particle dynamics, including observations of the radial phase space density profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Case Studies of Forest Windthrows and Mesoscale Convective Systems in Amazonia

Abstract This study identifies 38 cases of windthrows in the Amazonia to explore the relationship between windthrows and the characteristics (storm passing time, cloud top temperature, and maximum precipitation) of mesoscale convective systems (MCSs) that produced them. Most of windthrow cases in this study occurred in August and September. The storm passing time is positively correlated with the size of windthrows. MCSs with colder cloud top temperature (with a mean at 206 K)—indicating deeper convection—resulted in large windthrows, while those with warm cloud top (with a mean above 230 K) resulted in relatively small windthrows except for windthrows in the western Amazonia. No significant relationship is found between maximum precipitation intensity and the area of windthrows.

54 ENVIRONMENTAL SCIENCES↗

Electrical Validation Testing for ORPC MHK Generator, Modification 6: ORPC SBV for MHK Generator System (CRADA Final Report)

For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.

17 WIND ENERGY↗

Profiling the molecular destruction rates of temperature and humidity as well as the turbulent kinetic energy dissipation in the convective boundary layer

A simultaneous deployment of Doppler, temperature, and water-vapor lidars is able to provide profiles of molecular destruction rates and turbulent kinetic energy (TKE) dissipation in the convective boundary layer (CBL). Horizontal wind profiles and profiles of vertical wind, temperature, and moisture fluctuations are combined, and transversal temporal autocovariance functions (ACFs) are determined for deriving the dissipation and molecular destruction rates. These are fundamental loss terms in the TKE as well as the potential temperature and mixing ratio variance equations. These ACFs are fitted to their theoretical shapes and coefficients in the inertial subrange. Error bars are estimated by a propagation of noise errors. Sophisticated analyses of the ACFs are performed in order to choose the correct range of lags of the fits for fitting their theoretical shapes in the inertial subrange as well as for minimizing systematic errors due to temporal and spatial averaging and micro- and mesoscale circulations. We demonstrate that we achieve very consistent results of the derived profiles of turbulent variables regardless of whether 1 or 10 s time resolutions are used. We also show that the temporal and spatial length scales of the fluctuations in vertical wind, moisture, and potential temperature are similar with a spatial integral scale of ≈160 m at least in the mixed layer (ML). The profiles of the molecular destruction rates show a maximum in the interfacial layer (IL) and reach values of ϵ m ≃ 7 x 10 -4 g 2 kg −2 s −1 for mixing ratio and ϵ θ ≃ 1.6 x 10 -3 K 2 s −1 for potential temperature. In contrast, the maximum of the TKE dissipation is reached in the ML and amounts to ≃ 10 -2 m 2 s −3 . We also demonstrate that the vertical wind ACF coefficient k w ∝ $\overline{w'^{2}}$ and the TKE dissipation ϵ ∝ ($\overline{w'^{2}}$) 3/2 . For the molecular destruction rates, we show that ϵ m ∝ $\overline{m'^{2}}$ ($\overline{w'^{2}}$) 1/2 and ϵ θ ∝ $\overline{θ'^{2}}$ ($\overline{w'^{2}}$) 1/2 . These equations can be used for parameterizations of ϵ, ϵ m , and ϵ θ . All noise error bars are derived by error propagation and are small enough to compare the results with previous observations and large-eddy simulations. The results agree well with previous observations but show more detailed structures in the IL. Consequently, the synergy resulting from this new combination of active remote sensors enables the profiling of turbulent variables such as integral scales, variances, TKE dissipation, and the molecular destruction rates as well as deriving relationships between them. The results can be used for the parameterization of turbulent variables, TKE budget analyses, and the verification of large-eddy simulations.

dissipation rate↗

Modeling and Harmonic Stability of MMC-HVDC With Passive Circulating Current Filters

A modular multilevel converter (MMC) is an emerging converter technology widely used in wind power applications using high-voltage direct current (HVDC) transmission, and it has been largely investigated in medium-voltage solar harvesting as well as electric motor drives. Different from studies dealing with active circulating current control loops, this paper focuses on impedance modeling and harmonic stability studies for MMCs with passive circulating current filters (PCCFs). A power stage circuit including a PCCF is transformed and remodeled to obtain small-signal formulations. This transformation leads to additional high-order matrix computing complexity due to the added impedance subnetwork matrix from the PCCF as well as relevant crossed-frequency impacts. To simplify the computational burden, the proposed model aims to solve one arm equation instead of all six MMC arm equations. To achieve this result, additional challenges occur when the MMC is connected to a renewable energy source instead of the grid voltage, where low-level zero-sequence components might exist in the neutral point of three phases, especially in the case of no integrated advanced modular voltage balancing control, which prevents computational simplification. To overcome this challenge, further impedance matrix adjustments are conducted in this paper to theoretically suppress the impact of zero-sequence harmonics when obtaining small-signal impedance, taking into account the frequency coupling effect. Finally, simulations are carried out to validate the developed impedance model under different operating scenarios. Harmonic stability case studies of MMCs with PCCFs connected to renewable energy current sources are also presented, where frequency-domain stability analyses based on Bode diagrams are compared to time-domain simulation waveforms and FFTs, which validate the effectiveness of the proposed impedance model.

24 POWER TRANSMISSION AND DISTRIBUTION↗