Gamma spectrometry with semiconductor detectors
Lithium drifted germanium and silicon semiconducting detectors compared with thallium activated sodium iodide crystal scintillation counter for gamma spectrometry
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lithium drifted germanium and silicon semiconducting detectors compared with thallium activated sodium iodide crystal scintillation counter for gamma spectrometry
At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.
The low-temperature performance of silicon diffused junction detectors in the measurement of low energy X-rays is reported. The detectors have an area of 0.04 sq cm and a thickness of 100 microns. The spectral resolutions of these detectors were found to be in close agreement with expected values, indicating that the defects introduced by the high-temperature processing required in the device fabrication were not deleteriously affecting the detection of low-energy X-rays. Device performance over a temperature range of 77 K to 150 K is given. These detectors were designed to detect low-energy X-rays in the presence of minimum ionizing electrons. The successful application of silicon-diffused junction technology to X-ray detector fabrication may facilitate the development of other novel silicon X-ray detector designs.
Low-Gain Avalanche Diodes (LGAD) are a class of silicon sensors developed for the fast detection of Minimum Ionizing Particles (MIPs). The development was motivated by the need of resolving piled-up tracks of charged particles emerging from several vertexes originating from the same bunch-crossing in High-Energy Physics (HEP) collider experiments, which, however, are separated not only in space but also in time by a few tens of picoseconds. Built on thin silicon substrates and featuring an internal moderate gain, they provide fast signals for excellent timing performance, which are therefore useful to distinguish the different tracks. Unfortunately, this comes at the price of poor spatial resolution. To overcome this limitation, other families of LGAD-based silicon sensors which can deliver in the same substrate both excellent timing and spatial information are under development. Such devices are, to name a few, capacitively coupled LGADs (AC-LGAD), deep-junction LGADs (DJ-LGAD) and trench-isolated LGADs (TI-LGADs). These devices can be fabricated by even small-scale research-focused clean rooms for faster development within the scientific community. However, to scale up production, efforts towards integrating these sensor concepts in CMOS substrates, with the obvious advantage of the possibility of integrating part of the read-out electronics in the same substrate, have begun.
Building on the success of the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory, the Gamma Ray Large Area Space Telescope (GLAST) will make a major step in the study of such subjects as blazars, gamma Ray bursts, the search for dark matter, supernova remnants, pulsars, diffuse radiation, and unidentified high energy sources. The instrument will be built on new and mature detector technologies such as silicon strip detectors, low-power low-noise LSI, and a multilevel data acquisition system. GLAST is in the research and development phase, and one full tower (of 25 total) is now being built in collaborating institutes. The prototype tower will be tested thoroughly at Stanford Linear Accelerator Center (SLAC) in the fall of 1999.
Liulin, a dosimetry-radiometry system, was developed to satisfy the requirements for active flux and dose rate measurements for the flight of the second Bulgarian cosmonaut in 1988. The system consists of a compact battery-operated silicon solid state detector unit and a read/write microcomputer and telemetry unit. We describe the pre-flight calibrations with charged particles, using radioactive sources and accelerated 170 MeV/nucleon proton and alpha particles at the Dubna, Russia cyclotron. We discuss comparisons with data obtained on Mir with the French-built tissue equivalent LET spectrometer NAUSICAA. Lastly, we describe post-flight calibrations performed with 1 GeV/nucleon 56Fe ions at the Brookhaven National Laboratory AGS accelerator, where the instrument was mounted in tandem with several thin position-sensitive silicon detectors behind a stopping target. The silicon detectors provided an energy spectrum for the surviving charged nuclear fragments for which the flux and absorbed dose were recorded by Liulin.
Single-photon detectors operating on satellites for use in a quantum communications network can incur large dark-count-rate increases from the natural radiation environment of space. Displacement damage to the material lattice of a detector from the ionizing radiation can result in a permanent dark-count increase in the detector. In this work, we analyze the radiation-induced dark-count rate of a silicon single-photon avalanche diode onboard a satellite at different orbiting altitudes, as well as, the additional radiation from a nuclear-disturbed environment caused by a high-altitude nuclear explosion. For detectors on low Earth orbit satellites, protons are the biggest source of radiation damage and are best mitigated by choosing an orbit that minimizes exposure when passing through the South Atlantic Anomaly and Polar Cusps. Detectors on medium Earth orbit and geostationary orbit satellites, if shielded by more than 10 mm of aluminum, provide the best platform in terms of the least amount of radiation damage to the detectors. In the event of a high-altitude nuclear explosion, the artificial radiation belts produced by the explosion will cause too much damage to silicon single-photon detectors on low Earth orbit satellites and render them unfit for quantum communications in less than a day. Higher orbit satellites will only suffer minor dark-count-rate increases from the artificial radiation belts.
In this article, β - decay studies of neutron-rich isotopes 43,45 S performed at the National Superconducting Cyclotron Laboratory are reported. β -delayed $\gamma$ transitions were detected by an array of 16 clover detectors surrounding the Beta Counting Station, which consists of a 40×40 double-sided silicon strip detector followed by a single-sided silicon strip detector. β -decay half-lives were extracted for 43,45 S by correlating implants and decays in the pixelated implant detector and by considering further coincidences with $\gamma$ transitions in the daughter nuclei. Further, the level structures of 43,45 Cl are expanded by the addition of 20 and 8 new $\gamma$ transitions in 43 Cl and 45 Cl respectively, and core-excited negative-parity states were observed in both nuclei for the first time. For 45 S, a large fraction of the β -decay strength was observed feeding neutron-unbound states in 45 Cl, which, decaying by delayed neutrons, populated excited states in the β 1 n daughter, 44 Cl. Experimental observations were compared to detailed shell-model calculations using the SDPFSDG-MU interaction to highlight the role of the diminished N = 28 neutron shell gap and the near degeneracy of the proton s 1/2 and d 3/2 orbitals in the structure of the neutron-rich Cl isotopes. The current work also provides further support to a ground-state spin-parity assignment of 3/2 + in 45 Cl.
Linear arrays with up to 63 micromachined thermopile infrared detectors on silicon substrates have been constructed and tested. Each detector consists of a suspended silicon nitride membrane with 11 thermocouples of sputtered Bi-Te and Bi-Sb-Te thermoelectric elements films. At room temperature and under vacuum these detectors exhibit response times of 99 ms, zero frequency D* values of 1.4 x 10(exp 9) cmHz(exp 1/2)/W and responsivity values of 1100 V/W when viewing a 1000 K blackbody source. The only measured source of noise above 20 mHz is Johnson noise from the detector resistance. These results represent the best performance reported to date for an array of thermopile detectors. The arrays are well suited for uncooled dispersive point spectrometers. In another embodiment, also with Bi-Te and Bi-Sb-Te thermoelectric materials on micromachined silicon nitride membranes, detector arrays have been produced with D* values as high as 2.2 x 10(exp 9) cm Hz(exp 1/2)/W for 83 ms response times.
The effects of field funneling and range straggling have been quantitatively observed in the measurement of charge collected from alpha-particle tracks in silicon surface-barrier charged-particle detectors. The method described may be used for the straight-forward measurement of charge collection from heavy ions in these and other semiconductor devices.
Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The film's morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.
First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm. This array measures the energies of unconfined energetic 3 MeV protons and 1 MeV tritons mainly produced by beam-thermal DD reactions during neutral beam injection heating. Diamond detectors have the potential to be uniquely suited to detect charged fusion products as they promise to be much more radiation resistant and much less sensitive to temperature variations compared to silicon-based detectors. Using silicon and diamond-based detectors simultaneously allowed us to directly compare the performance of these two detector types. PD particle rates measured during different plasma scenarios are presented and compared to neutron rates measured using the neutron camera upgrade and TRANSP predictions.
The sPHENIX experiment is a state-of-the-art jet and heavy flavor physics detector, which successfully recorded its first Au + Au collision data at 200 GeV at the Relativistic Heavy Ion Collider (RHIC). sPHENIX will provide heavy flavor physics measurements at RHIC, covering an unexplored kinematic region and unprecedented precision, to probe the parton energy loss mechanism, parton transport coefficients in quark–gluon plasma, and the hadronization process under various medium conditions. At the center of sPHENIX, the monolithic active pixel sensor (MAPS)-based VerTeX detector (MVTX) is a high-precision silicon pixel detector. The MVTX provides excellent position resolution and the capability of operating in continuous streaming readout mode, allowing precise vertex determination and recording a large data sample, both of which are particularly crucial for heavy flavor physics measurements. In this work, we will show the general performance of heavy-flavor hadron reconstruction. In addition, we will discuss the commissioning experience with sPHENIX. Finally, we will provide the projection of b-hadron and jet observables and discuss the estimated constraints on theoretical models.
A new focal plane detector system for the Berkeley Gas-filled Separator (BGS) was designed, constructed, and tested offline with various α-decay and conversion-electron sources. The SuperHeavy RECoils (SHREC) detector comprises sets of double-sided silicon strip detectors arranged in an open-faced cuboid geometry. Alongside the detector upgrade new digital data acquisition electronics have been commissioned offline. This setup aims to detect separated recoiling heavy and superheavy nuclei as well as their correlated radioactive decay paths with improved energy resolution and overall sensitivity.
The ATIC balloon-born experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germinate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as charge detector together with silicon matrix. Relative fluxes of nuclei B, C, N, O in the energy region from about 20 GeV/nucleon to 200 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented.
The energy deposition distribution for protons and helium galactic cosmic ray primaries at 0.3, 10, and 25 TeV/nucleon in the ATIC-2 silicon matrix detector are simulated with GEANT4. The GEANT3 geometrical model of ATIC developed by the University of Maryland was combined with a GEANT4 application developed for the Deep Space Test Bed (DSTB) detector package. The new code included relatively minor modifications to completely describe the ATIC materials and a more detailed model of the Silicon Matrix detector. For this analysis all particles were started as a unidirectional beam at a single point near the center of the Silicon Matrix front surface. The point was selected such that each primary passed through at least two of the overlapping silicon pixels.
Theory, fabrication, and electric properties of lithium drifted silicon radiation detector with large sensitive volume
The ATIC balloon-borne experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germanate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was essentially improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as an additional charge detector together with the silicon matrix. The flux ratios of nuclei B/C, O/C, N/C in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented. The results are compared with existing theoretical predictions.