Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “signal analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Algorithm Reveals Sinusoidal Component Of Noisy Signal

Algorithm performs simple statistical analysis of noisy signal to yield preliminary indication of whether or not signal contains sinusoidal component. Suitable for preprocessing or preliminary analysis of vibrations, fluctuations in pressure, and other signals that include large random components. Implemented on personal computer by easy-to-use program.

Kwok, Lloyd C.↗

Asymmetry In Biphase Data Signals

Report presents analysis of some effects of asymmetry in Manchester (biphase) binary data signal transmitted by phase modulation of sinusoidal carrier signal. Report extends analysis described in article, "Effects of Asymmetry of NRZ Data Signals on Performance" (NPO-18261), to include case where data biphase-modulated directly on residual carrier.

Nguyen, Tien M.↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This work seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the biosensors. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as exposure to radiation. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), and reporting agents. The reporting will be accomplished through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation. These nanosensors could facilitate the success and increase the safety of extended space flight. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. This period, synthesis of the test-bed biosensors continued. Studies were performed on the candidate fluorescent dyes to determine which might be suitable for the biosensor under development. Development continued on producing an artificial capillary bed as a tool for the use in the production of the fluorescence signal monitor. Work was also done on the in vitro multispectral analysis system, which uses the robotic microscope.

Baker, James R.↗

Control Parameter Sensitivity Study for Inverter-Based-Resource Dominated Grids: A Small Signal Stability Approach and Framework

The growing adoption of renewable energy is driving the prevalence of inverter-based resources (IBRs) within power grids. Future power grids will integrate both grid-following IBRs (GFM-IBRs) and grid-forming IBRs (GFL-IBRs) alongside synchronous generators. Therefore, it is crucial to perform stability studies that account for all components and especially control interactions related to IBRs. Extensive research has performed to study the IBR-related stability, however, the sensitivity study of IBRs' control parameters on system stability has not been adequately studied yet, especially from a systematic way. Therefore, this paper conducts a small signal stability analysis for a generic grid with multiple types of resources and develops an analytical framework for assessing the sensitivity of control parameters affecting stability margins. To achieve that, the non-autonomous reduced-order non-linear dynamic model is developed for a generic power system with multiple synchronous generator-based resources (SGBRs), GFM-IBRs, and GFL-IBRs. Based on the analytic model, a systematic framework for parametric sensitivity on systems' asymptotic stability is developed. A parameter sensitivity analysis based on eigenvalue methods is proposed. The impact of the droop controllers of GFM-IBRs, PQ-dispatch and the PLL controller of GFL-IBR on the system asymptotic stability is discussed. This sensitivity study is aiming to provide deep insights on control parameters' impact on system stability, and gives direction for parameter tuning in case of instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The detection and analysis of point processes in biological signals

A pragmatic approach to the detection and analysis of discrete events in biomedical signals is taken. Examples from both clinical and basic research are provided. Introductory sections discuss not only discrete events which are easily extracted from recordings by conventional threshold detectors but also events embedded in other information carrying signals. The primary considerations are factors governing event-time resolution and the effects limits to this resolution have on the subsequent analysis of the underlying process. The analysis portion describes tests for qualifying the records as stationary point processes and procedures for providing meaningful information about the biological signals under investigation. All of these procedures are designed to be implemented on laboratory computers of modest computational capacity.

Anderson, D. J.↗

ThunderDOEME: A Seismoacoustic Deployment at Langmuir Observatory

This report documents a two-month deployment of seismoacoustic instrumentation at the Langmuir Observatory, located outside Socorro, New Mexico. A total of eleven Fairfield Nodal Seismometers and fifteen GEM infrasound loggers were deployed from June 2 to August 5, 2025. The nodal seismometers recorded data for an average of 34 days, while the GEMs had variable operational durations throughout the deployment period. The primary objective was to capture thunder signals using seismoacoustic instrumentation, contributing to a better understanding of the acoustic and seismic phenomena associated with thunder. Coinciding with this deployment, optical and electric field sensors were present, providing information regarding the timing and location of lightning strikes in the region. Additionally, triggered lightning strikes were conducted, serving as a ground truth for validating the captured thunder signals. Preliminary analysis of the data reveals clear thunder signals in both the seismic and infrasound recordings, with peak frequencies observed across a range of 4 to 40 Hz, depending on the event.

47 OTHER INSTRUMENTATION↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This proposal seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the sensor/actuators. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as the exposure to radiation or infectious agents. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), magnetic particles and metals, and imaging agents. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. These molecules would also be able to administer therapeutics in response to the needs of the astronaut, and act as actuators to remotely manipulate an astronaut as necessary to ensure their safety. The reporting will be accomplished either through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation, or through functional MRI. These nanosensors coupled to NEMS devices could facilitate the success and increase the safety of extended space flight.

Baker, James R., Jr.↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable bandpass filter channel for signal spectrum analysis and signal discrimination is presented, including performance improvements to stability and precise matching between filter stages. The 8 th -order filter channel achieves an effective Q-factor of 4.5 and dynamic range of 60 dB, has an operational frequency range from 2 kHz to 100 kHz, and consumes 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology is selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2 nd -order filter cells and is fabricated in 130-nm 1.2-V CMOS technology, making it suitable for use in monolithic integrated spectral analysis (MISA) applications.

Long, Gavin↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications, while maintaining high dynamic range and a wide operational frequency range. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable analog filter channel for signal spectrum analysis and signal discrimination is presented. Project specifications required a programmable, high-order, monolithic bandpass filter channel with small chip area, low power consumption, high dynamic range, and wide operational frequency range. The 8th-order filter channel presented in this work provides an effective Q-factor of 4.5 and a minimum dynamic range (DR) of approximately 85 dB, while allowing for tuning across a range of center frequencies from 2 kHz to 100 kHz, with power consumption of a single 8th-order filter channel measured at 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology was selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2nd-order filter cells, resulting in a single 8th-order filter channel, fabricated in 130-nm 1.2-V CMOS technology, suitable for use in monolithic integrated spectral analysis (MISA1) applications.

Long, Gavin B.↗

Analysis of Cygnus Electrical Signals

The United States initiated the Subcritical Experiment (SCE) program to support a stockpile stewardship mission shortly after the 1992 moratorium on underground nuclear testing was established. Many SCE’s are conducted at the Nevada National Security Site (NNSS) in Nevada. Cygnus is a high-energy radiation generating device (RGD) located and operated at the NNSS and is a primary diagnostic for the SCE program. The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2. From creation of the high power V-I drive to energy transport and X-ray conversion at the rod-pinch diode, the Cygnus machines utilize the following components: oil-filled Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line (CTL), three-cell vacuum induction voltage adder (IVA), and rod-pinch diode. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. Each source has the following X-ray specifications: 1 mm diameter, 4 rad at 1 m, and 50 ns radiation pulse. SCEs are both single-event and high-value; therefore, a high level of performance in reliability and reproducibility are key issues of Cygnus. Prior to executing such a SCE, there are a formidable number of shots (e.g., each of the two Cygnus RGDs charging and discharging properly into the rod-pinch diode load) that must be executed to determine reliability and reproducibility of the Cygnus RGDs. For every shot on Cygnus, voltages and currents along the machine are recorded and analyzed. In this paper we summarize attributes of the voltage and current waveforms at different locations using distribution plots. These distribution plots are used to quantify the reliability and reproducibility for Cygnus. This analysis methodology will provide a standard to trouble shoot results of individual Cygnus shots, and also to monitor long term Cygnus performance. Accordingly, this type of extensive analysis will contribute to optimized Cygnus performance on SCEs.

42 ENGINEERING↗

Analysis of Lunar Seismic Signals: Determination of Instrumental Parameters and Seismic Velocity Distributions

Inverse filters were designed to correct the effect of instrumental response, coupling of the seismometer to the ground, and near surface structures. The least squares technique was used to determine the instrumental constants and the transfer functions of the long period lunar seismographs. The influence of noise and the results of these calculations are discussed.

Horvath, P.↗

A note on the use of coherent integration in periodogram analysis of MST radar signals

The effect of coherent integration on the periodogram method to estimate the power spectra of MST radar signals is examined. The spectrum estimate usually is biased, even when care is taken to reduce the aliasing effects. Due to this bias, the signal power for Doppler shifted signals is underestimated by as much as 4 dB. The use of coherent integration in reducing the effect of aliased power line harmonics is pointed out.

Rastogi, P. K.↗

Noncoherent sampling technique for communications parameter estimations

This paper presents a method of noncoherent demodulation of the PSK signal for signal distortion analysis at the RF interface. The received RF signal is downconverted and noncoherently sampled for further off-line processing. Any mismatch in phase and frequency is then compensated for by the software using the estimation techniques to extract the baseband waveform, which is needed in measuring various signal parameters. In this way, various kinds of modulated signals can be treated uniformly, independent of modulation format, and additional distortions introduced by the receiver or the hardware measurement instruments can thus be eliminated. Quantization errors incurred by digital sampling and ensuing software manipulations are analyzed and related numerical results are presented also.

Su, Y. T.↗