Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “selected inversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Correlation-driven topological band inversion in VSe 2

Recent spectroscopic studies have uncovered topological surface states and band inversion in 1⁢T−VSe 2 , positioning this material at the intersection of correlated electron physics and nontrivial band topology. While previous interpretations attribute these features to surface strain, the microscopic origin of the topological band structure remains unresolved. Here, we present an alternative explanation based on electronic correlations, showing that a negative effective Hubbard interaction (𝑈 eff < 0) applied to the Se 4p orbitals can reproduce the experimentally observed band inversion at both the Γ and 𝑀 points. Using density functional theory (DFT) calculations with orbital-selective interactions, we demonstrate that this approach naturally gives rise to topological surface states without invoking structural distortions. In conclusion, our results highlight the crucial role of ligand orbital correlations in shaping band topology and provide a novel framework for understanding and engineering topological phases in chalcogenide-based quantum materials.

36 MATERIALS SCIENCE↗

Semimetallicity and electron-hole liquid in two-dimensional C and BN based compounds

Insulating-metallic transition mediated by substitutional atoms is predicted in a series of two-dimensional carbon-based structures. Introducing Si atoms in selected sites of tetrahexcarbon [Carbon 137 (2018) 266] according to rational chemical rules, metallicity by trivial band inversion without band gap opening is induced. Additional substitution of remaining C atoms by BN dimers introduces no changes in the metallic properties. A series of isomorphous two-dimensional materials with isoelectronic structures derived by exchanging group IV elements exhibiting various band gaps is obtained. Dynamical stability is verified with phonon analysis and beyond the harmonic approximation with molecular dynamics up to room temperature. The semi-metallic compounds have well-nested pockets of carriers and are good candidates for the formation of an excitonic insulator.

36 MATERIALS SCIENCE↗

Switchable resolution in soft x-ray tomography of single cells

The diversity of living cells, in both size and internal complexity, calls for imaging methods with adaptable spatial resolution. Soft x-ray tomography (SXT) is a three-dimensional imaging technique ideally suited to visualizing and quantifying the internal organization of single cells of varying sizes in a near-native state. The achievable resolution of the soft x-ray microscope is largely determined by the objective lens, but switching between objectives is extremely time-consuming and typically undertaken only during microscope maintenance procedures. Since the resolution of the optic is inversely proportional to the depth of focus, an optic capable of imaging the thickest cells is routinely selected. This unnecessarily limits the achievable resolution in smaller cells and eliminates the ability to obtain high-resolution images of regions of interest in larger cells. Here, we describe developments to overcome this shortfall and allow selection of microscope optics best suited to the specimen characteristics and data requirements. We demonstrate that switchable objective capability advances the flexibility of SXT to enable imaging cells ranging in size from bacteria to yeast and mammalian cells without physically modifying the microscope, and we demonstrate the use of this technology to image the same specimen with both optics.

59 BASIC BIOLOGICAL SCIENCES↗

Outer planet Pioneer imaging communications system study

The effects of different types of imaging data compression on the elements of the Pioneer end-to-end data system were studied for three imaging transmission methods. These were: no data compression, moderate data compression, and the advanced imaging communications system. It is concluded that: (1) the value of data compression is inversely related to the downlink telemetry bit rate; (2) the rolling characteristics of the spacecraft limit the selection of data compression ratios; and (3) data compression might be used to perform acceptable outer planet mission at reduced downlink telemetry bit rates.

Source record↗

Development of Multi-Sensor Global Cloud and Radiance Composites for Earth Radiation Budget Monitoring from DSCOVR

The Deep Space Climate Observatory (DSCOVR) enables analysis of the daytime Earth radiation budget via the onboard Earth Polychromatic Imaging Camera (EPIC) and National Institute of Standards and Technology Advanced Radiometer (NISTAR). Radiance observations and cloud property retrievals from low earth orbit and geostationary satellite imagers have to be co-located with EPIC pixels to provide scene identification in order to select anisotropic directional models needed to calculate shortwave and longwave fluxes. A new algorithm is proposed for optimal merging of selected radiances and cloud properties derived from multiple satellite imagers to obtain seamless global hourly composites at 5-kilometer resolution. An aggregated rating is employed to incorporate several factors and to select the best observation at the time nearest to the EPIC measurement. Spatial accuracy is improved using inverse mapping with gradient search during reprojection and bicubic interpolation for pixel resampling. The composite data are subsequently remapped into EPIC-view domain by convolving composite pixels with the EPIC point spread function (PSF) defined with a half-pixel accuracy. PSF-weighted average radiances and cloud properties are computed separately for each cloud phase. The algorithm has demonstrated contiguous global coverage for any requested time of day with a temporal lag of under 2 hours in over 95 percent of the globe.

Khlopenkov, Konstantin↗

Chiral Spin Textures in Amorphous Iron–Germanium Thick Films

Topological solitary fields, such as magnetic and polar skyrmions, are envisioned to revolutionize microelectronics. These configurations have been stabilized in solid-state materials with a global inversion symmetry breaking, which translates in magnetic materials into a vector spin exchange known as the Dzyaloshinskii-Moriya interaction (DMI), as well as spin chirality selection and isotropic solitons. This work reports experimental evidence of 3D chiral spin textures, such as helical spins and skyrmions with different chirality and topological charge, stabilized in amorphous Fe-Ge thick films. Overall, these results demonstrate that structurally and chemically disordered materials with a random DMI can resemble inversion symmetry broken systems with similar magnetic properties, moments, and states. Disordered systems are distinguished from systems with global inversion symmetry breaking by their degenerate spin chirality that allows for forming isotropic and anisotropic topological spin textures at remanence, while offering greater flexibility in materials synthesis, voltage, and strain manipulation.

36 MATERIALS SCIENCE↗

Nonlinear time-domain spectroscopy near a band inversion

We develop a theory for the nonlinear time-domain response of a semimetal driven by an ultrafast optical pulse. At quadratic order in the driving field we find that the response near a band inversion transition contains a coherent oscillating component proportional to field intensity with a frequency that can be tuned over a wide range (from terahertz to the near IR) selected by the chemical potential. Finally, we illustrate the effect by calculating the induced current as a function of time for a two-band system with time-reversal symmetry but broken parity symmetry to study semimetals where large Berry curvature near a band inversion transition promotes this nonlinear response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated treatment planning for a dedicated multi-source intracranial radiosurgery treatment unit using projected gradient and grassfire algorithms

Purpose: The purpose of this work is to develop a framework to the inverse problem for radiosurgery treatment planning on the Gamma Knife{sup Registered-Sign} Perfexion Trade-Mark-Sign (PFX) for intracranial targets. Methods: The approach taken in the present study consists of two parts. First, a hybrid grassfire and sphere-packing algorithm is used to obtain shot positions (isocenters) based on the geometry of the target to be treated. For the selected isocenters, a sector duration optimization (SDO) model is used to optimize the duration of radiation delivery from each collimator size from each individual source bank. The SDO model is solved using a projected gradient algorithm. This approach has been retrospectively tested on seven manually planned clinical cases (comprising 11 lesions) including acoustic neuromas and brain metastases. Results: In terms of conformity and organ-at-risk (OAR) sparing, the quality of plans achieved with the inverse planning approach were, on average, improved compared to the manually generated plans. The mean difference in conformity index between inverse and forward plans was -0.12 (range: -0.27 to +0.03) and +0.08 (range: 0.00-0.17) for classic and Paddick definitions, respectively, favoring the inverse plans. The mean difference in volume receiving the prescribed dose (V{sub 100}) between forward and inverse plans was 0.2% (range: -2.4% to +2.0%). After plan renormalization for equivalent coverage (i.e., V{sub 100}), the mean difference in dose to 1 mm{sup 3} of brainstem between forward and inverse plans was -0.24 Gy (range: -2.40 to +2.02 Gy) favoring the inverse plans. Beam-on time varied with the number of isocenters but for the most optimal plans was on average 33 min longer than manual plans (range: -17 to +91 min) when normalized to a calibration dose rate of 3.5 Gy/min. In terms of algorithm performance, the isocenter selection for all the presented plans was performed in less than 3 s, while the SDO was performed in an average of 215 min. Conclusions: PFX inverse planning can be performed using geometric isocenter selection and mathematical modeling and optimization techniques. The obtained treatment plans all meet or exceed clinical guidelines while displaying high conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity of Inferred Subphotospheric Velocity Field to Mode Selection, Analysis Technique and Noise

The horizontal velocity immediately below the photosphere was inferred from observations of high degree solar oscillations by an optimal averaging inversion technique. The sensitivity of the results to various details of both the inversion and the determination of the frequencies are investigated. The results are shown to be quite stable to the choice of most parameters, suggesting that this procedure produces reliable estimates of the subsurface velocity.

Hill, F.↗

Measurement of the top-quark pole mass in dileptonic $t\overline{t}$ + 1-jet events at $\sqrt{s}=13$ TeV with the ATLAS experiment

A measurement of the top-quark pole mass $m$$^{pole}_{t}$ is presented in $t\bar{t}$ events with an additional jet, $t\bar{t}$+ 1-jet, produced in pp collisions at $\sqrt{s} = 13 TeV. The data sample, recorded with the ATLAS experiment during Run 2 of the LHC, corresponds to an integrated luminosity of 140 fb −1 . Events with one electron and one muon of opposite electric charge in the final state are selected to measure the $t\bar{t}$ + 1-jet differential cross-section as a function of the inverse of the invariant mass of the $t\bar{t}$ + 1-jet system. Iterative Bayesian Unfolding is used to correct the data to enable comparison with fixed-order calculations at next-to-leading-order accuracy in the strong coupling. The process pp → $t\bar{t}$j(2 → 3), where top quarks are taken as stable particles, and the process pp → $b\bar{b}$l + vl – $\overline{ν}$j (2 → 7), which includes top-quark decays to the dilepton final state and off-shell effects, are considered. The top-quark mass is extracted using a χ 2 fit of the unfolded normalized differential cross-section distribution. The results obtained with the 2 → 3 and 2 → 7 calculations are compatible within theoretical uncertainties, providing an important consistency check.

Hadron-Hadron Scattering↗

Combined UHV/high-pressure catalysis setup for depth-resolved near-surface spectroscopic characterization and catalytic testing of model catalysts

An ultra-high vacuum (UHV) setup for “real” and “inverse” model catalyst preparation, depth-resolved near-surface spectroscopic characterization, and quantification of catalytic activity and selectivity under technologically relevant conditions is described. Due to the all-quartz reactor attached directly to the UHV-chamber, transfer of the catalyst for in situ testing without intermediate contact to the ambient is possible. The design of the UHV-compatible re-circulating batch reactor setup allows the study of reaction kinetics under close to technically relevant catalytic conditions up to 1273 K without contact to metallic surfaces except those of the catalyst itself. With the attached differentially pumped exchangeable evaporators and the quartz-microbalance thickness monitoring equipment, a reproducible, versatile, and standardised sample preparation is possible. For three-dimensional near-surface sample characterization, the system is equipped with a hemispherical analyser for X-ray photoelectron spectroscopy (XPS), electron-beam or X-ray-excited Auger-electron spectroscopy, and low-energy ion scattering measurements. Due the dedicated geometry of the X-ray gun (54.7°, “magic angle”) and the rotatable sample holder, depth analysis by angle-resolved XPS measurements can be performed. Thus, by the combination of characterisation methods with different information depths, a detailed three-dimensional picture of the electronic and geometric structure of the model catalyst can be obtained. To demonstrate the capability of the described system, comparative results for depth-resolved sample characterization and catalytic testing in methanol steam reforming on PdGa and PdZn near-surface intermetallic phases are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a program of record of inland water quality: Exploiting present and heritage multispectral sensors for maximum information extraction

Degradation of Earth’s inland water resources due to anthropogenic perturbations and climate anomalies at both local and global scales continues to place human health at substantial risk. There is now a growing necessity to develop pragmatic approaches that allow timely and effective extrapolation of local processes, to spatially resolved global products, and to promote operational and sustainable resource policy management. This research exploits recent advancements in bio-optical modeling, cloud computing, and machine learning to enhance our capacity to leverage present and heritage satellite data. Recent research suggests that sensors with low spectral resolution, such as Sentinel 2 and Landsat missions, contain enough hidden spectral variation which can be exploited using data-driven approaches. The availability of three decades of archival imagery will open doors to discover global trends of eutrophication and increased cyanobacteria dominance and provide valuable insight to the development of predictive methodologies. Preliminary efforts in synthetic emulation of global natural inland waters will be discussed and contextualized against satellite radiometric measurement uncertainty, satellite data product uncertainties and causal signal ambiguity over the visible wavelength range, supported by high quality field and image data for selected inland aquatic sites. Insights on water quality estimation via data-driven machine learning models versus matrix inversions will be discussed, and how we can exploit spectral-spatial relationships in high spatial resolution data. A cross-sensor synergistic approach with detailed uncertainty analysis based on optical water types, will allow for unprecedented global snapshots of fine scale ecological dynamics of inland waters.

Inland↗

Influence of non-solvent chemistry on polybenzimidazole hollow fiber membrane preparation

Polybenzimidazole membrane materials have attractive H 2 /CO 2 separation characteristics and high thermo-chemical stability for elevated temperature synthesis (syn) gas separations. The development of PBI membranes with a thin defect-free selective layer and porous support morphology is vital to achieving industrially attractive separation performance. This work is focused on developing a fundamental understanding of the liquid-liquid demixing-based phase inversion process for asymmetric PBI hollow fiber membrane (HFM) formation. The development of industrially attractive HFMs is a challenging process due to the complex interplay between phase equilibria, phase inversion kinetics, and interfacial mass transfer that exist during the liquid-liquid demixing process. Numerous parameters including the dope, bore, and outer coagulant chemistries and compositions significantly influence the HFM morphologies produced. Here, a systematic study is conducted to investigate the phase inversion process parameters including the roles of the non-solvent solubility and diffusivity parameters with respect to the solvent and PBI on the phase inversion process. Furthermore, the influence of dope, bore and coagulant chemistries and compositions on PBI HFM morphology are investigated. As a result, the fabricated PBI HFMs are evaluated for their ideal H 2 and CO 2 permeance and H 2 /CO 2 selectivity at 250 °C to benchmark their separation performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous Planck, Swift, and Fermi Observations of X-ray and Gamma-ray Selected Blazars

We present simultaneous Planck, Swift, Fermi, and ground-based data for 105 blazars belonging to three samples with flux limits in the soft X-ray, hard X-ray, and gamma-ray bands, with additional 5 GHz flux-density limits to ensure a good probability of a Planck detection. We compare our results to those of a companion paper presenting simultaneous Planck and multi-frequency observations of 104 radio-loud northern active galactic nuclei selected at radio frequencies. While we confirm several previous results, our unique data set allows us to demonstrate that the selection method strongly influences the results, producing biases that cannot be ignored. Almost all the BL Lac objects have been detected by the Fermi Large Area Telescope (LAT), whereas 30% to 40% of the flat-spectrum radio quasars (FSRQs) in the radio, soft X-ray, and hard X-ray selected samples are still below the gamma-ray detection limit even after integrating 27 months of Fermi-LAT data. The radio to sub-millimetre spectral slope of blazars is quite flat, with (alpha) approx 0 up to about 70GHz, above which it steepens to (alpha) approx -0.65. The BL Lacs have significantly flatter spectra than FSRQs at higher frequencies. The distribution of the rest-frame synchrotron peak frequency (nu(sup s)(sub peak)) in the spectral energy distribution (SED) of FSRQs is the same in all the blazar samples with (nu(sup s)(sub peak)) = 10(exp 13.1 +/- 0.1) Hz, while the mean inverse Compton peak frequency, (nu(sup IC)(sub peak)), ranges from 10(exp 21) to 10(exp 22) Hz. The distributions of nu(sup s)(sub peak) and nu(sup IC)(sub peak) of BL Lacs are much broader and are shifted to higher energies than those of FSRQs; their shapes strongly depend on the selection method. The Compton dominance of blazars. defined as the ratio of the inverse Compton to synchrotron peak luminosities, ranges from less than 0.2 to nearly 100, with only FSRQs reaching values larger than about 3. Its distribution is broad and depends strongly on the selection method, with gamma-ray selected blazars peaking at approx 7 or more, and radio-selected blazars at values close to 1, thus implying that the common assumption that the blazar power budget is largely dominated by high-energy emission is a selection effect. A comparison of our multi-frequency data with theoretical predictions shows that simple homogeneous SSC models cannot explain the simultaneous SEDs of most of the gamma-ray detected blazars in all samples. The SED of the blazars that were not detected by Fermi~LAT may instead be consistent with SSC emission. Our data challenge the correlation between bolometric luminosity and nu(sup s)(sub peak) predicted by the blazar sequence.

Giommi, P.↗

Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

60 APPLIED LIFE SCIENCES↗

Parallel multiple-chain DRAM MCMC for large-scale geosteering inversion and uncertainty quantification

Geosteering is the proactive control of a wellbore placement based on the downhole measurements, aiming at maximizing economic production from the well. We report the recent development of azimuthal resistivity logging-whiledrilling (LWD) tools have a much larger depth of detection, thus sets higher demands for geosteering inversion as more unknown parameters need to be taken into account in the earth model to be inverted. For complicated nonlinear problems, traditional deterministic inversion methods are more likely to be trapped near local optima. In general, Markov chain Monte Carlo (MCMC) inversion methods are more capable of finding the global optimal solution and providing additional uncertainty analyses by sampling from the target distribution. However, MCMC methods usually have the problem of slow convergence. Even though optimization methods like delayed rejection (DR) and adaptive Metropolis (AM) were proposed to speed up the convergence, using MCMC methods to solve geosteering inversion problems may still incur unacceptable time cost. To reduce the sampling cost of MCMC methods, we use parallel multiple-chain DRAM MCMC methods to solve geosteering inverse problems and estimate the corresponding uncertainty. A clustering method, density-based spatial clustering of applications with noise (DBSCAN), is applied to select the best solution among many results. Lastly, the simulation results show that running many relatively short MCMC chains for one problem can obtain a similar result as running a long single chain. Besides, avoiding communications between multiple Markov chains during the sampling process yields almost linear scalability.

97 MATHEMATICS AND COMPUTING↗

Modification of Bi:YIG film properties by substrate surface ion pre-treatment

Highlights: • Effects of substrates ion beam treatment on magnetoptical properties Bi:YIG films. • Substrate surface damage results in sign inversion of the magneto-optical effects. • Atomically smooth films growth takes place on low energy ions treated substrates. • High energy ions treatment results in selective nucleation mechanism of the growth. - Abstract: The effect of a controlled ion beam pre-treatment of (1 1 1)-oriented Gd{sub 3}Ga{sub 5}O{sub 12} substrates on the magneto-optical properties and surface morphology of the ultrathin bismuth-substituted yttrium–iron garnet films with a composition Bi{sub 2.8}Y{sub 0.2}Fe{sub 5}O{sub 12} was studied. It has been shown that the observed sign inversion of magneto-optical effects (Faraday rotation and magnetic circular dichroism) observed in films that were deposited on the GGG substrate pre-treated by 1 keV and 4 keV Ar{sup +} ion beams is a result of the substrate surface amorphization caused by the ion bombardment.

36 MATERIALS SCIENCE↗

Multicriteria Optimization in Intensity-Modulated Radiation Therapy Treatment Planning for Locally Advanced Cancer of the Pancreatic Head

Purpose: Intensity-modulated radiation therapy (IMRT) affords the potential to decrease radiation therapy-associated toxicity by creating highly conformal dose distributions. However, the inverse planning process can create a suboptimal plan despite meeting all constraints. Multicriteria optimization (MCO) may reduce the time-consuming iteration loop necessary to develop a satisfactory plan while providing information regarding trade-offs between different treatment planning goals. In this exploratory study, we examine the feasibility and utility of MCO in physician plan selection in patients with locally advanced pancreatic cancer (LAPC). Methods and Materials: The first 10 consecutive patients with LAPC treated with IMRT were evaluated. A database of plans (Pareto surface) was created that met the inverse planning goals. The physician then navigated to an 'optimal' plan from the point on the Pareto surface at which kidney dose was minimized. Results: Pareto surfaces were created for all 10 patients. A physician was able to select a plan from the Pareto surface within 10 minutes for all cases. Compared with the original (treated) IMRT plans, the plan selected from the Pareto surface had a lower stomach mean dose in 9 of 10 patients, although often at the expense of higher kidney dose than with the treated plan. Conclusion: The MCO is feasible in patients with LAPC and allows the physician to choose a satisfactory plan quickly. Generally, when given the opportunity, the physician will choose a plan with a lower stomach dose. The MCO enables a physician to provide greater active clinical input into the IMRT planning process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗