Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Time-resolved multiple probe spectroscopy

Time-resolved multiple probe spectroscopy combines optical, electronic, and data acquisition capabilities to enable measurement of picosecond to millisecond time-resolved spectra within a single experiment, using a single activation pulse. This technology enables a wide range of dynamic processes to be studied on a single laser and sample system. The technique includes a 1 kHz pump, 10 kHz probe flash photolysis-like mode of acquisition (pump-probe-probe-probe, etc.), increasing the amount of information from each experiment. We demonstrate the capability of the instrument by measuring the photolysis of tungsten hexacarbonyl (W(CO){sub 6}) monitored by IR absorption spectroscopy, following picosecond vibrational cooling of product formation through to slower bimolecular diffusion reactions on the microsecond time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects of charmonium studies in the Belle-II experiment

TheBelle-II experiment at the SuperKEKB super-B factorywill begin data acquisition in 2016, the expected integrated luminosity being 50 ab{sup -1}. A statistical data sample of record volume 50 times as large as that of the statistical data sample accumulated earlier at the Belle detector will make it possible to measure precisely the parameters of new exotic states discovered recently at B factories and to clarify the origin of these states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Maximum-based Timing Acquisition for Spread-Spectrum Communications

This paper proposes and analyzes a new packet detection and timing acquisition method for spread spectrum systems. The proposed method provides an enhancement over the typical thresholding techniques that have been proposed for direct sequence spread spectrum (DS-SS). The effective implementation of thresholding methods typically require accurate knowledge of the received signal-to-noise ratio (SNR), which is particularly difficult to estimate in spread spectrum systems. Instead, we propose a method which utilizes a consistency metric of the location of maximum samples at the output of a filter matched to the spread spectrum waveform to achieve acquisition, and does not require knowledge of the received SNR. Through theoretical study, we show that the proposed method offers a low probability of missed detection over a large range of SNR with a corresponding probability of false alarm far lower than other methods. Computer simulations that corroborate our theoretical results are also presented. Although our work here has been motivated by our previous study of a filter bank multicarrier spread-spectrum (FB-MC-SS) system, the proposed method is applicable to DS-SS systems as well.

99 GENERAL AND MISCELLANEOUS↗

MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction

Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical applications. Learning Objectives: Learn the general methodologies associated with model-based 3D image reconstruction. Learn the potential advantages in image quality and dose associated with model-based image reconstruction. Learn the challenges associated with computational load and image quality assessment for such reconstruction methods. Learn how imaging task can be incorporated as a means to drive optimal image acquisition and reconstruction techniques. Learn how model-based reconstruction methods can incorporate prior information to improve image quality, ease sampling requirements, and reduce dose.

60 APPLIED LIFE SCIENCES↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Challenges in the Use of AI-Driven Non-Destructive Spectroscopic Tools for Rapid Food Analysis

Routine, remote, and process analysis for foodstuffs is gaining attention and can provide more confidence for the food supply chain. A new generation of rapid methods is emerging both in the literature and in industry based on spectroscopy coupled with AI-driven modelling methods. Current published studies using these advanced methods are plagued by weaknesses, including sample size, abuse of advanced modelling techniques, and the process of validation for both the acquisition method and modelling. This paper aims to give a comprehensive overview of the analytical challenges faced in research and industrial settings where screening analysis is performed while providing practical solutions in the form of guidelines for a range of scenarios. After extended literature analysis, we conclude that there is no easy way to enhance the accuracy of the methods by using state-of-the-art modelling methods and the key remains that capturing good quality raw data from authentic samples in sufficient volume is very important along with robust validation. A comprehensive methodology involving suitable analytical techniques and interpretive modelling methods needs to be considered under a tailored experimental design whenever conducting rapid food analysis.

59 BASIC BIOLOGICAL SCIENCES↗

A rapid methods development workflow for high-throughput quantitative proteomic applications

Recent improvements in the speed and sensitivity of liquid chromatography-mass spectrometry systems have driven significant progress toward system-wide characterization of the proteome of many species. These efforts create large proteomic datasets that provide insight into biological processes and identify diagnostic proteins whose abundance changes significantly under different experimental conditions. Yet, these system-wide experiments are typically the starting point for hypothesis-driven, follow-up experiments to elucidate the extent of the phenomenon or the utility of the diagnostic marker, wherein many samples must be analyzed. Transitioning from a few discovery experiments to quantitative analyses on hundreds of samples requires significant resources both to develop sensitive and specific methods as well as analyze them in a high-throughput manner. To aid these efforts, we developed a workflow using data acquired from discovery proteomic experiments, retention time prediction, and standard-flow chromatography to rapidly develop targeted proteomic assays. We demonstrated this workflow by developing MRM assays to quantify proteins of multiple metabolic pathways from multiple microbes under different experimental conditions. With this workflow, one can also target peptides in scheduled/dynamic acquisition methods from a shotgun proteomic dataset downloaded from online repositories, validate with appropriate control samples or standard peptides, and begin analyzing hundreds of samples in only a few minutes.

02 PETROLEUM↗

A Laser-Based Method for On-Site Analysis of UF6 at Enrichment Plants

The International Atomic Energy Agency’s (IAEA’s) long-term research and development plan calls for more cost-effective and efficient safeguard methods to detect and deter misuse of gaseous centrifuge enrichment plants (GCEPs). The IAEA’s current safeguards approaches at GCEPs are based on a combination of routine and random inspections that include environmental sampling and destructive assay (DA) sample collection from UF6 in-process material and selected cylinders. Samples are then shipped offsite for subsequent laboratory analysis. In this paper, a new DA sample collection and onsite analysis approach that could help to meet challenges in transportation and chain of custody for UF6 DA samples is introduced. This approach uses a handheld sampler concept and a Laser Ablation, Laser Absorbance Spectrometry (LAARS) analysis instrument, both currently under development at the Pacific Northwest National Laboratory. A LAARS analysis instrument could be temporarily or permanently deployed in the IAEA control room of the facility, in the IAEA data acquisition cabinet, for example. The handheld PNNL DA sampler design collects and stabilizes a much smaller DA sample mass compared to current sampling methods. The significantly lower uranium mass reduces the sample radioactivity and the stabilization approach diminishes the risk of uranium and hydrogen fluoride release. These attributes enable safe sample handling needed during onsite LAARS assay and may help ease shipping challenges for samples to be processed at the IAEA’s offsite laboratory. The LAARS and DA sampler implementation concepts will be described and preliminary technical viability results presented.

LAARS↗

Active Learning‐Driven Inkless Additive Nanomanufacturing for Printed Electronics

Inkless additive nanomanufacturing for printed electronics promises broad material and substrate versatility, yet the high-dimensional print parameter space makes tuning print parameters time-intensive. We present a Bayesian optimization study that constructs a digital twin from printed-silver data to benchmark surrogate models, acquisition functions, and batch sizes head-to-head to achieve user-specified target resistance. Tested surrogate models included Gaussian process, random forest, and Bayesian neural network surrogates with expected improvement and confidence bound acquisition functions. In total, we evaluate 48 unique model configurations alongside a random sampling baseline for comparison. For printed silver, the Bayesian neural network with a batch size of one achieved the lowest average cumulative regret, approximately four times more efficient on average than random sampling. To balance performance and substrate space, a random forest model with expected improvement and a batch size of four was chosen as the model for validation testing. Applying this chosen configuration to copper with an additional print parameter, the model achieved a resistance within 0.15 Ω of a 1 Ω target in fewer than 30 printed lines across five validation sets. Altogether, the workflow yields a tuned and validated model that efficiently guides experiments toward the target while simultaneously learning the parameter space.

Bevel, Colton [Auburn University, AL (United State↗

Data-Efficient Generation of Protein Conformational Ensembles with Backbone-to-Side-Chain Transformers

Excitement at the prospect of using data-driven generative models to sample configurational ensembles of biomolecular systems stems from the extraordinary success of these models on a diverse set of high-dimensional sampling tasks. Unlike image generation or even the closely related problem of protein structure prediction, there are currently no data sources with sufficient breadth to parametrize generative models for conformational ensembles. To enable discovery, a fundamentally different approach to building generative models is required: models should be able to propose rare, albeit physical, conformations that may not arise in even the largest data sets. Here, in this work, we introduce a modular strategy to generate conformations based on “backmapping” from a fixed protein backbone that (1) maintains conformational diversity of the side chains and (2) couples the side-chain fluctuations using global information about the protein conformation. Our model combines simple statistical models of side-chain conformations based on rotamer libraries with the now ubiquitous transformer architecture to sample with atomistic accuracy. Together, these ingredients provide a strategy for rapid data acquisition and hence a crucial ingredient for scalable physical simulation with generative neural networks.

36 MATERIALS SCIENCE↗

A New {sup 14}C-AMS Facility at UFF- Niteroi, Brazil

We report a new Accelerator Mass Spectrometry facility at the Physics Institute of Fluminense Federal University in Brazil, the Nuclear Chronology Laboratory - LACRON. The sample preparation laboratory is ready to perform chemical treatment through graphitization and the acquisition of a Single Stage Accelerator Mass Spectrometry System is in progress. LACRON will be the first independent laboratory to perform the {sup 14}C-AMS technique not only in Brazil but in Latin America.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel von Hamos spectrometer for efficient X-ray emission spectroscopy in the laboratory

We present a novel, highly efficient von Hamos spectrometer for X-ray emission spectroscopy (XES) in the laboratory using highly annealed pyrolitic graphite crystals as the dispersive element. The spectrometer covers an energy range from 2.5 keV to 15 keV giving access to chemical speciation and information about the electronic configuration of 3d transition metals by means of the Kβ multiplet. XES spectra of Ti compounds are presented to demonstrate the speciation capabilities of the instrument. A spectral resolving power of E/ΔE = 2000 at 8 keV was achieved. Typical acquisition times range from 10 min for bulk material to hours for thin samples below 1 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background

Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300–1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10{sup −5}M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Hybrid-Learning Algorithm for Online Dynamic State Estimation in Multimachine Power Systems

With the increasing penetration of distributed generators in the smart grids, having knowledge of rapid real-time electromechanical dynamic states has become crucial to system stability control. Conventional Supervisory Control and Data Acquisition (SCADA)-based dynamic state estimation (DSE) techniques are limited by the slow sampling rates, while the emerging phasor measurement units (PMUs) technology enables rapid real-time measurements at network nodes. Using generator bus terminal voltages, we propose a hybrid-learning DSE (HL-DSE) algorithm to estimate the synchronous machine rotor angle and speed in real time. The HL-DSE takes the power system model into account and trains neuroestimators with real-time data in an online manner. Compared with traditional DSE methods, the HL-DSE overcomes limitations by using a data-driven approach in conjunction with the physical power system model. The time efficiency, accuracy, convergence, and robustness of the proposed algorithm are tested under noises and fault conditions in both small- and large-scale test systems. Simulation results show that the proposed HL-DSE is much more computationally efficient than widely used Kalman filter (KF)-based methods while maintaining comparable accuracy and robustness. In particular, HL-DSE is over 100 times faster than square-root unscented KF (SR-UKF) and 80 times faster than extended KF (EKF). The advantages and challenges of the HL-DSE are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-AB-BRA-06: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An MRI Compatible Externally and Internally Deformable Lung Motion Phantom for Multi-Modality IGRT

Purpose: MRI has become an attractive tool for tumor motion management. Current MR-compatible phantoms are only capable of reproducing translational motion. This study describes the construction and validation of a more realistic, MRI-compatible lung phantom that is deformable internally as well as externally. We demonstrate a radiotherapy application of this phantom by validating the geometric accuracy of the open-source deformable image registration software NiftyReg (UCL, UK). Methods: The outer shell of a commercially-available dynamic breathing torso phantom was filled with natural latex foam with eleven water tubes. A rigid foam cut-out served as the diaphragm. A high-precision programmable, in-house, MRI-compatible motion platform was used to drive the diaphragm. The phantom was imaged on a 3T scanner (Philips, Ingenia). Twenty seven tumor traces previously recorded from lung cancer patients were programmed into the phantom and 2D+t image sequences were acquired using a sparse-sampling sequence k-t BLAST (accn=3, resolution=0.66×0.66×5mm3; acquisition-time=110ms/slice). The geometric fidelity of the MRI-derived trajectories was validated against those obtained via fluoroscopy using the on board kV imager on a Truebeam linac. NiftyReg was used to perform frame by frame deformable image registration. The location of each marker predicted by using NiftyReg was compared with the values calculated by intensity-based segmentation on each frame. Results: In all cases, MR trajectories were within 1 mm of corresponding fluoroscopy trajectories. RMSE between centroid positions obtained from segmentation with those obtained by NiftyReg varies from 0.1 to 0.21 mm in the SI direction and 0.08 to 0.13 mm in the LR direction showing the high accuracy of deformable registration. Conclusion: We have successfully designed and demonstrated a phantom that can accurately reproduce deformable motion under a variety of imaging modalities including MRI, CT and x-ray fluodoscopy, making it an invaluable research tool for validating novel motion management strategies. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

The High-Pressure Characterization of Energetic Materials: 2-Methyl-5-Nitramino-2H-Tetrazole

The isothermal structural properties, equation of state, and vibrational dynamics of 2MNT were studied under high-pressure using synchrotron XRD and optical Raman and IR microspectroscopy. Analysis of the XRD patterns revealed no indication of a phase transition to near 15 GPa and the pressure-volume isotherm remained smooth to 15 GPa. Near 15 GPa, significant sample damage was observed from the X-ray beam which precluded the acquisition of patterns above this pressure. XRD and Raman spectroscopic measurements showed the monoclinic ambient condition phase of 2MNT remains the dominant phase to near 20 GPa, although a shift of the NO{sub 2} IR active vibrational modes to lower frequencies suggested a subtle geometry modification not reflected in the XRD data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

Structure and Thermal Expansion of YSZ and La 2 Zr 2 O 7 Above 1500°C from Neutron Diffraction on Levitated Samples

High-temperature time-of-flight neutron diffraction experiments were performed in this paper on cubic yttria-stabilized zirconia (YSZ, 10 mol% YO 1.5 ) and lanthanum zirconate (LZ) prepared by laser melting. Three spheroids of each composition were aerodynamically levitated and rotated in argon flow and heated with a CO 2 laser. Unit cell, positional and atomic displacement parameters were obtained by Rietveld analysis. Below ~1650°C the mean thermal expansion coefficient (TEC) for YSZ is higher than for LZ (13 ± 1 vs. 10.3 ± 0.6) × 10 -6 /K. From ~1650°C to the onset of melting of LZ at ~2250°C, TEC for YSZ and LZ are similar and within (7 ± 2) × 10 -6 /K. LZ retains the pyrochlore structure up to the melting temperature with Zr coordination becoming closer to perfectly octahedral. Congruently melting LZ is La deficient. The occurrence of thermal disordering of oxygen sublattice (Bredig transition) in defect fluorite structure was deduced from the rise in YSZ TEC to ~25 × 10 -6 /K at 2350°C–2550°C with oxygen displacement parameters (U iso ) reaching 0.1 Å 2 , similar to behavior observed in UO 2 . Acquisition of powder-like high-temperature neutron diffraction data from solid-levitated samples is feasible and possible improvements are outlined. Finally, this methodology should be applicable to a wide range of materials for high-temperature applications.

36 MATERIALS SCIENCE↗