Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

High-heat transfer lithium-ion batteries: A new era in battery thermal management

Despite advances in lithium-ion battery technology, critical challenges remain that must be addressed to accelerate electric vehicle (EV) adoption and global energy transformation. Significantly improved battery thermal management (BTM) is key to overcoming these challenges. BTM approaches focus on increasing heat transfer coefficients via air, liquid, or refrigerant cooling, but less attention is given to reducing the battery's thermal resistance, a major bottleneck for heat transfer. This work introduces a novel approach to reduce battery thermal resistance by integrating in-plane heat transfer with optimized cell geometry, minimized thermal resistances, and reduced interfacial resistances, representing a departure from previous methods. The standard prismatic can cell incorporating this technology is referred to as the high heat transfer (HHT) battery. An equivalent resistance battery thermal model is developed for speed and accuracy, validated against experimental data in the literature, demonstrating strong correlation and ensuring reliable predictions for real-world performance. Thermal performance metrics of the conventional and HHT batteries are compared using a parametric study with air, liquid, and refrigerant boundary conditions across a range of aspect ratios. The HHT battery shows a heat removal rate up to 20 times higher than a conventional battery. These findings suggest that HHT technology could be transformative for EV battery performance, enabling fast charging, mitigating thermal runaway, extending battery life, reducing cold-weather power loss, increasing reliability, lowering costs, and enabling higher energy density, all critical for EV adoption and energy transformation. Future work will focus on prototyping and real-world testing to refine these findings for commercial-scale applications.

25 ENERGY STORAGE↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Designing slippery rough surfaces to enhance dropwise condensation of low surface tension fluid

Enhancing low surface tension liquid condensation is critical for achieving high energy efficiency and reducing the size of thermal energy systems. Extensive research has focused on promoting dropwise condensation of these liquids using state-of-the-art coatings on plain surfaces. However, maintaining dropwise condensation with low surface tension fluids is challenging due to rivulet formation, resulting in wetted tails that transition to filmwise condensation at elevated heat fluxes. Here, to address this issue, we uncover the role of surface structures and surface chemistry in the dropwise condensation of low surface tension ethanol on slippery rough surfaces (SRS). High-performance dropwise condensation has been achieved on slippery microchannels grafted with perfluoropolyether. The SRS uniquely facilitates rapid lateral droplet removal, enabling faster directional droplet shedding without rivulet formation. The resulting higher droplet removal frequency on SRS leads to heat transfer coefficients 100 % and 500 % higher than conventional dropwise and filmwise condensation on plain surfaces, respectively. Our findings uncover the pivotal role of rapid droplet removal through slippery microchannels in sustaining dropwise condensation of low surface tension liquids. This study introduces a new paradigm for promoting dropwise condensation using engineered SRS that incorporates surface structure and surface chemistry. The work will provide fundamental design guidelines to design efficient and compact condensers that use costly or flammable low global warming potential refrigerants in future refrigeration systems.

Dropwise condensation↗

Depicting the roles of CuO secondary phase and heat treatment in driving the magnetic and magnetocaloric features of Pr 2/3 Sr 1/3 MnO 3 manganite

In this work, we report a detailed experimental study regarding the impact of copper oxide (CuO) secondary phase and heat treatments on the structural, magnetic, and magnetocaloric properties of the near-room temperature Pr 2/3 Sr 1/3 MnO 3 (PSMO) magnetic refrigerant. Our investigations are carried out by using structural and microstructural analyses, alongside magnetization measurements. Here, the analysis of X-ray diffraction data of PSMO(95%)-CuO(5%) (PSMO-CuO) samples shows the coexistence of both CuO and PSMO phases. Further, the microstructural analysis of PSMO-CuO reveals that the addition of CuO significantly enhances the grains size. On the other hand, the added secondary phase markedly reduces the Curie temperature (T c ) from 293 K for PSMO to about 273 K for PSMO-CuO composite while increasing the magnetocaloric effect. This decrease in T c is associated with a significant change from 162° to about 156° in the Mn-OII-Mn bond angle respectively. Moreover, performed investigations regarding the role of heat treatments unveil that the observed changes in the structural and magnetic features are mainly driven by the secondary phase that modify grains size and double-exchange interactions in the PSMO compound. Interestingly, our findings demonstrate that the Curie temperature of the PSMO and accordingly its magnetocaloric effect can be tailored by adding small amounts of CuO without need to substitution on cation sites. In the light of obtained results, a multilayered refrigerant composed of PSMO and PSMO-CuO is proposed to cover the magnetic cooling temperature range close to room-temperature. The resulting entropy change remains practically constant between 273 K and 293 K. Such a behavior is highly appreciated from a practical point of view, particularly in cases where the cooling process is carried out by using the AMR and Ericsson cycles.

36 MATERIALS SCIENCE↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecular Insight into Fluorocarbon Adsorption in Pore Expanded Metal–Organic Framework Analogs

The rapid growth in the global energy demand for space cooling requires the development of more efficient environmental chillers for which adsorption-based cooling systems can be utilized. Here, in this contribution, we explore sorbents for chiller use via a pore-engineering concept to construct analogs of the 1-dimensional pore metal–organic framework MOF-74 by using elongated organic linkers and stereochemistry control. The prepared pore-engineered MOFs show remarkable equilibrium adsorption of the selected fluorocarbon refrigerant that is translated to a modeled adsorption-based refrigeration cycle. To probe molecular level interactions at the origin of these unique adsorption properties for this series of Ni-MOFs, we combined in situ synchrotron X-ray powder diffraction, neutron powder diffraction, X-ray absorption spectroscopy, calorimetry, Fourier transform infrared techniques, and molecular simulations. Our results reveal the coordination of fluorine (of CH2F in R134a) to the nickel(II) open metal centers at low pressures for each Ni-MOF analog and provide insight into the pore filling mechanism for the full range of the adsorption isotherms. The newly designed Ni-TPM demonstrates exceptional R134a adsorption uptake compared to its parent microporous Ni-MOF-74 due to larger engineered pore size/volume. The application of this adsorption performance toward established chiller conditions yields a working capacity increase for Ni-TPM of about 400% from that of Ni-MOF-74, which combined with kinetics directly correlates to both a higher coefficient of performance and a higher average cooling capacity generated in a modeled chiller.

Zheng, Jian↗

Magnetocaloric effect in Mn-rich Heusler-derived alloys for room temperature-based applications

Magnetic refrigeration-based technologies rely on the magnetocaloric properties of materials and are crucial for improving energy efficiency and for supporting clean environments. However, materials possessing significant magnetocaloric properties that can be used for room temperature-based applications are still lacking. Heusler alloys (such as Mn–Ni–Ga) show giant magnetocaloric effects, which can be further improved by tuning their composition. Herein, we optimized the ratio of Ni to Ga to achieve an alloy with unique magnetocaloric properties. Here, the alloy demonstrated a substantial magnetocaloric effect, attributed to its narrow temperature range for structural and magnetic phase transitions (near room temperature with minimal hysteresis). Structural phase changes were also observed through high-resolution transmission electron microscopy. Optimum entropy changes, calculated from isothermal magnetization curves (4 Tesla magnetic field), were found to be 24.50 J kg −1 K −1 , which is higher than that of state-of-the-art alloys. Experimental demonstration of the magnetocaloric effect (refrigeration cycle) was also carried out using a thermal imaging camera. Furthermore, first-principles calculations were conducted to validate the experimental findings, specifically focusing on the compositional effects on the structural transitions and magnetic properties of the investigated MNG alloys.

36 MATERIALS SCIENCE↗

Magnetocaloric effect observations near room temperature in few-layered chromium telluride (Cr 2 Te 3 )

Transition metal telluride compositions are explored extensively for their unique magnetic behavior. Few-layered chromium telluride (Cr 2 T e3 ) exhibits a near-room-temperature phase transition, where the material can be effectively used in applications such as magnetic refrigeration. Compared to existing magnetocaloric materials, Heusler alloys, and rare-earth-based alloys, the large-scale synthesis of mechanically exfoliated Cr 2 Te 3 involves less complexity, resulting in a stable composition. Compared to existing tellurides, Cr 2 Te 3 exhibited a large change in magnetic entropy (|ΔS M |) of 1.88 J k g−1 K −1 at a magnetic field of 4 T. A refrigeration capacity (RC) of ∼82 J kg −1 was determined from the change in magnetic entropy versus temperature curve. The results were comparable with those for existing Cr-based compounds. First-principles density functional theory (DFT) confirmed the magnetic properties of Cr 2 Te 3 , including a near-room-temperature Curie temperature, T C , consistent with experimental results. Here, structural transition was also observed using first-principles DFT, which is responsible for the magnetic behavior.

36 MATERIALS SCIENCE↗

Significant enhancement of magnetocaloric effect in a NiMnCuGa Heusler alloy through textural modification

Magnetocaloric materials are of increasing interest to bring magnetic refrigeration to everyday households and drastically impact the energy demands for temperature control devices. In this work, a polycrystalline Heusler alloy of composition Ni2Mn0.76Cu0.24Ga with coinciding structural and magnetic transformation temperatures was subjected to compressive stress assisted thermal cycling (SATC) to enhance the magnetic properties by inducing a preferred orientation in the martensite. Isofield magnetization measurements showed a sharpening of the transformation between ferromagnetic martensite and paramagnetic austenite due to SATC. In isothermal magnetization measurements, SATC was seen to increase the magnetostructural coupling. With a 2 T applied magnetic field, the magnetocaloric effect (MCE) increased from ∼10 to ∼25 J/kg K and the refrigeration capacity (RC) almost doubled due to SATC. Heat capacity measurements were largely unaffected by SATC. The change in adiabatic temperature was estimated by using Cp and change in magnetic entropy (ΔSM) calculations. SATC was seen to increase ΔTad from ∼1.2 K to 2 K for an applied magnetic field of 2 T. Neutron diffraction measurements revealed highly textured martensite in the as received state that rotated to a more ideal preferred orientation after SATC that enhanced the magnetostructural transformation; and thus, improving the MCE and ΔTad.

McLeod, M. V. (ORCID:0000000329883516)↗

A building performance-based approach to determining energy resilience for grocery stores in the event of a power outage

Evaluating progress toward a built environment that is best equipped to serve communities during a regional power outage will require metrics that capture the energy resilience of the unique buildings and businesses most crucial to the well-being of those nearby. We focused on grocery stores as key buildings for which access, and thus energy resilience, is critical during a disaster when power is unavailable. We evaluated the energy resilience of these buildings by offering and testing building-scale metrics that assess business continuity potential during a power outage. Metrics proposed in this study are calculated based on the unique power loads characteristic to grocery stores, primarily refrigeration and maintaining safe indoor environmental conditions. Building simulations based on varying levels of backup power were carried out against occupant safety and comfort parameters to apply these metrics, with additional criteria imposed on grocery stores to capture the inventory and sales loss from food spoilage resulting from a lack of refrigeration power. Findings from this study demonstrate the feasibility of our proposed metrics and methodology to serve as a low-data burden means for stakeholders to evaluate the energy resilience of grocery stores, with greater implications in helping to understand the impact on community-scale energy resilience.

Siegel, Lino Sanchez↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LCLS-II helium cryoplant and cryo distribution system installation

The helium cryoplant and cryo distribution system (CDS) are key elements of the new superconducting Linac Coherent Light Source (LCLS-II) and will provide superfluid helium to the accelerator. The cryoplant consists of two helium refrigerators with an equivalent 4.5 K refrigeration capacity of 18 kW each. The 37 cryomodules of the LINAC will be operated at a temperature of 2.0 K to accelerate a 4 GeV electron beam that will generate extremely bright X-ray laser light. Two five-stage cold compressor cold boxes will be utilized to provide superfluid helium II for the superconducting cavity structures with a total cooling capacity of 8 kW at 2.0 K. This paper describes the installation of the LCLS-II cryoplant and CDS. The LCLS-II cryoplant was designed and contributed by Jefferson Lab. To expedite the project completion the reuse of proven design and technology from the Jefferson Lab CHL-2 cryoplant was the preferred strategy. The CDS consists of ~260 m thermally shielded and vacuum super insulated transfer lines, two distribution boxes and eight feed and end caps, and was designed and contributed by Fermilab. SLAC installed the cryoplant components into a newly erected building and the CDS components into the existing accelerator tunnel and klystron gallery with strong engineering support from both partner labs.

43 PARTICLE ACCELERATORS↗

Tuning the temperature range of superelastic Ni-Ti alloys for elastocaloric cooling via thermal processing

Abstract Caloric cooling enlisting solid-state refrigerants is potentially a promising eco-friendly alternative to conventional cooling based on vapor compression. The most common refrigerant materials for elastocaloric cooling to date are Ni-Ti based superelastic shape memory alloys. Here, we have explored tuning the operation temperature range of Ni 50.8 Ti 49.2 for elastocaloric cooling. In particular, we have studied the effect of thermal treatments (a.k.a. aging) on the transformation temperature, superelasticity, and elastocaloric effects of Ni 50.8 Ti 49.2 shape memory alloy tubes. The isothermal compressive test revealed that the residual strain of thermally-treated Ni-Ti tubes at room temperature approaches zero as aging time is increased. Short-time aging treatment at 400 °C resulted in good superelasticity and elastocaloric cooling performance with a large tunable austenite finish ( A f ) temperature range of 24.7 °C, as determined from the A f temperature of the samples that were aged 5–120 min. The main reason of the property change is the formation of a different amount of Ni 4 Ti 3 precipitates in the NiTi matrix. Our findings show that it is possible to tailor the A f temperature range for development of cascade elastocaloric cooling systems by thermally treating a starting single composition Ni-Ti alloy.

36 MATERIALS SCIENCE↗

High-pressure neutron diffraction at ultra-low temperature

Neutron diffraction is a powerful tool in the study of quantum materials and associated emergent phenomena as it allows for direct detection of magnetic structure even at ultra-low temperatures. As pressure can drive systems across quantum critical points and tune emergent behaviors at the quantum scale, coupling neutron diffraction with extreme conditions of high pressure at (ultra-)low temperatures has been a key research target over decades. This has proven challenging as magnetic neutron diffraction typically requires large sample volumes due to flux limitations, whereas high-pressure studies require small sample volumes due to pressure limitations. Combining these two contradictory requirements poses many difficulties, but also brings opportunities in research and development. Here, we address these shortcomings through the use of a diamond anvil cell equipped with polycrystalline anvils with relatively large sample volumes coupled with the high neutron flux made available by the high-pressure diffractometer of the Spallation Neutron Source. This particular diamond anvil cell configuration has previously proven useful for single-crystal samples and is here coupled with the ultra-low temperatures of a dilution refrigerator for the first time. Our study on a single crystal of Yb 2 ⁢O 3 successfully collected magnetic neutron diffraction data at 5.3 GPa below 200 mK inside a dilution refrigerator. We have performed a detailed analysis of the magnetic diffraction data to investigate the magnetic structure under pressure and observed a subtle shift in the transition temperature. This development will open the door for future studies on magnetic materials with these much-desired coupled extremes of high pressure and ultra-low temperatures.

Wu, Yan [Oak Ridge National Laboratory (ORNL), Oak↗