Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Magnetocaloric refrigerator

The invention is for an apparatus and method for a refrigerator and a heat pump based on the magnetocaloric effect (MCE) offering a simpler, lighter, robust, more compact, environmentally compatible, and energy efficient alternative to traditional vapor-compression devices. The subject magnetocaloric apparatus alternately exposes a magnetocaloric material to strong and weak magnetic field while switching heat to and from the material. Action of the heat switches is coordinated with the magnetic field strength to move heat up the thermal gradient. The invention may be practiced with multiple magnetocaloric stages to attain large differences in temperature. Key applications include thermal management of electronics, as well as industrial and home refrigeration, heating, and air conditioning. The invention offers a simpler, lighter, compact, and robust apparatus compared to magnetocaloric devices of prior art. Furthermore, the invention may be run in reverse as a thermodynamic engine, receiving low-level heat and producing mechanical energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

Solid-state optical refrigerator for cryogenic cooling of payloads

A solid-state optical refrigerator for cryogenic cooling of a payload, the solid-state optical refrigerator including a laser cooling crystal including a first material and a dopant material; a thermal link including a second material, the thermal link being bonded to the laser cooling crystal and the thermal link being configured to be thermally linked to the payload to transfer heat conductively from the payload to the laser cooling crystal via the thermal link; and a vacuum chamber housing the laser cooling crystal and the thermal link, the vacuum chamber and thermal link having a combination of shape and coating such that laser and fluorescence light reflected off a wall of the vacuum chamber and laser and fluorescence light propagating within the thermal link are not incident on the payload.

Hehlen, Markus Peter↗

A Numerical Modelling Study on Submerged Condensers for Heat Pump Water Heaters Using Low-GWP Refrigerants

Challenges to global warming require reduction of GHG emissions, and increased use of renewable energy. Heat pumps extract energy from renewable sources and convert them to more useable forms for space conditioning, space heating and for water heating. They can be powered by renewable sources of electricity and must be engineered to use low global warming potentials (GWP) refrigerants (e.g., propane, GWP = 3) for a sustainable economy. Therefore, an electric heat pump water heaters (HPWH) using propane as refrigerant are developed in Oak Ridge National Laboratory to replace water heaters using all electric resistance and natural gas. A submerged condenser directly contacting with water is employed in the HPWH, which eliminates heat transfer barrier of the tank wall, and also prevents heat loss from the condenser tubes to the surrounding air. In present work, a numerical model is developed to model the submerged condenser. A dynamic temperature distribution on the condenser tubes from experimental data is applied to the model to enhance the accuracy of the numerical model. The model is essential to guide the design of the submerged condenser to achieve the performance required by the HPWH.

Zhang, Mingkan↗

Process for delivering liquid H 2 from an active magnetic regenerative refrigerator H 2 liquefier to a liquid H 2 vehicle dispenser

A process that includes pre-cooling a H 2 gas feedstock with a compressed liquid natural gas via a heat exchanger, introducing the pre-cooled H 2 gas feedstock into an active magnetic regenerative refrigerator H 2 liquefier module, and delivering liquid H 2 from the active magnetic regenerative refrigerator H 2 liquefier module to a liquid H 2 vehicle dispenser.

Holladay, Jamie D.↗

Magnetocaloric refrigerator

The invention is for an apparatus and method for a refrigerator and a heat pump based on the magnetocaloric effect (MCE) offering a simpler, lighter, robust, more compact, environmentally compatible, and energy efficient alternative to traditional vapor-compression devices. The subject magnetocaloric apparatus alternately exposes portions of an MCE material to strong and weak magnetic field while coordinating the heat flow between the exposed portions by heat bridges to move the heat up the thermal gradient. The invention may be practiced with multiple MCE material portions or segments to attain large differences in temperature. Key applications include thermal management of electronics, as well as industrial and home refrigeration, heating, and air conditioning. The invention offers a simpler, lighter, compact, and robust apparatus compared to magnetocaloric devices of prior art. Furthermore, the invention may be run in reverse as a thermodynamic engine, receiving low-level heat and producing mechanical energy.

Vetrovec, Jan↗

Magnetocaloric alloys useful for magnetic refrigeration applications

This invention relates to magnetocaloric materials comprising alloys useful for magnetic refrigeration applications. In some embodiments, the disclosed alloys may be Cerium, Neodymium, and/or Gadolinium based compositions that are fairly inexpensive, and in some cases exhibit only 2nd order magnetic phase transitions near their curie temperature, thus there are limited thermal and structural hysteresis losses. This makes these compositions attractive candidates for use in magnetic refrigeration applications. Surprisingly, the performance of the disclosed materials is similar or better to many of the known expensive rare-earth based magnetocaloric materials.

Ihnfeldt, Robin↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Design of the PIXIE Adiabatic Demagnetization Refrigerators

The Primordial Inflation Explorer (PIXIE) is a proposed mission to densely map the polarization of the cosmic microwave background. It will operate in a scanning mode from a sun-synchronous orbit, using low temperature detectors (at 0.1 K) and located inside a teslescope that is cooled to approximately 2.73 K - to match the background temperature. A mechanical cryocooler operating at 4.5 K establishes a low base temperature from which two adiabatic demagnetization refrigerator (ADR) assemblies will cool the telescope and detectors. To achieve continuous scanning capability, the ADRs must operate continuously. Complicating the design are two factors: 1) the need to systematically vary the temperature of various telescope components in order to separate the small polarization signal variations from those that may arise from temperature drifts and changing gradients within the telescope, and 2) the orbital and monthly variations in lunar irradiance into the telescope barrels. These factors require the telescope ADR to reject quasi-continuous heat loads of 2-3 millwatts, while maintaining a peak heat reject rate of less than 12 milliwatts. The detector heat load at 0.1 K is comparatively small at 1-2 microwatts. This paper will describe the 3-stage and 2-stage continuous ADRs that will be used to meet the cooling power and temperature stability requirements of the PIXIE detectors and telescope.

adiabatic demagnetization refrigerator↗

On-Orbit Operation of the Adiabatic Demagnetization Refrigerator on the Astro-H/Hitomi Soft X-ray Spectrometer Instrument

The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters, which is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADRs stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to cool both the helium tank (to about 1.5 K) and the detectors (to 50 mK) using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR.

sub-kelvin refrigeration↗

Characterization of Two Fast-Turnaround Dry Dilution Refrigerators for Scanning Probe Microscopy

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they typically suffer from comparatively worse vibrations than cryogen-based systems, necessitating the understanding and mitigation of vibrations for SPM applications. Here, in this work, we demonstrate the construction of two cryogen-free dilution refrigerator SPMs with minimal modifications to the factory default and we systematically characterize their vibrational performance. We measure the absolute vibrations at the microscope stage with geophones and use both microwave impedance microscopy and a scanning single-electron transistor to independently measure tip-sample vibrations. Additionally, we implement customized filtering and thermal anchoring schemes and characterize the cooling power at the scanning stage and the tip electron temperature. This work serves as a reference to researchers interested in cryogen-free SPMs, as such characterization is not standardized in the literature or available from manufacturers.

36 MATERIALS SCIENCE↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Autonomous quantum absorption refrigerators

Here, we propose a quantum absorption refrigerator using the quantum physics of resonant tunneling through quantum dots. The cold and hot reservoirs are fermionic leads, tunnel coupled via quantum dots to a central fermionic cavity, and we propose configurations in which the heat absorbed from the (very hot) central cavity is used as a resource to selectively transfer heat from the cold reservoir on the left to the hot reservoir on the right. Heat transport in the device is particle-hole symmetric; we find two regimes of cooling as a function of the dot energies—symmetric with respect to the Fermi energy of the reservoirs—and we associate them with heat transfer by electrons above the Fermi level and holes below the Fermi level. We also discuss optimizing the cooling effect by fine-tuning the energy of the dots as well as their linewidth and characterize regimes where the transport is thermodynamically reversible such that the Carnot coefficient of performance is achieved with zero cooling power delivered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pressure Exchanger for Energy Recovery in a Trans-Critical CO2 Refrigeration System

Trans-critical CO2 vapor compression (VC) refrigeration cycles require a high compression ratio, which is associated with high expansion losses. To recover these expansion losses, a pressure exchange process between the low- and high-pressure sides of the VC cycle is proposed and examined in this study. The proposed pressure exchange system is an open type constant volume process where the high- and low-pressure flows mix inside the system. This prototype is inspired by the pressure exchangers used in reverse-osmosis (RO) desalination systems. In this system, a 2D model was generated and modeled using the computational fluid dynamics (CFD) technique. The numerical model ignored any losses due to leakage or hydraulic friction and the process is considered adiabatic. For the modeling, it was assumed that the inlet conditions for the two pressure exchanger flows are similar to the flow conditions at the evaporator and gas cooler outlets in a VC cycle. Two parameters are examined to test the validity of the system and understand their effect on the performance, including the inlet flow rate represented by the inlet velocity and the process time represented by the speed of rotation. A total of nine cases were simulated and analyzed in this study.

30 DIRECT ENERGY CONVERSION↗