Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development of a Reference Model for Molten-Salt-Cooled Pebble-Bed Reactor Using SAM

To support the development and utilization of the SAM code for fluoride-salt-cooled high-temperature pebble-bed reactor (PB-FHR) safety analysis and licensing, an effort was devoted to developing reference models for PB-FHR primary loop and the reactor cavity cooling system (RCCS). A reference standard problem of a prototypical reactor design is foundational to NRC and industry to verify the adequacy of computer codes and evaluation models for a specific reactor type. The SAM code was enhanced for the reference PB-FHR model development, including a 1D-3D flow coupling scheme and conjugate heat transfer between porous media and solid structures. The reference FHR primary loop model was developed based on the UC Berkeley Mk1 FHR design with additional design features from the Kairos Power’s KP-FHR core. The PB-FHR core is modeled by a two-dimensional porous medium while the rest of the primary loop is represented by a SAM one-dimensional model. A SAM one-dimensional primary loop model was also developed for comparison using a single channel approach for the reactor core. Furthermore, the water-based NSTF cavity was modeled using SAM multi-dimensional flow module, to assist in evaluating SAM capabilities of modeling the emergency heat removal systems relying on RCCS concepts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impacts of rising air temperatures and emissions mitigation on electricity demand and supply in the United States: a multi-model comparison

The electric power sector both affects and is affected by climate change. Numerous studies highlight the potential of the power sector to reduce greenhouse gas emissions. Yet fewer studies have explored the physical impacts of climate change on the power sector. The present analysis examines how projected rising temperatures affect the demand for and supply of electricity. We apply a common set of temperature projections to three well-known electric sector models in the United States: the US version of the Global Change Assessment Model (GCAM-USA), the Regional Electricity Deployment System model (ReEDS), and the Integrated Planning Model (IPM®). Incorporating the effects of rising temperatures from a control scenario without emission mitigation into the models raises electricity demand by 1.6 to 6.5 % in 2050 with similar changes in emissions. The increase in system costs in the reference scenario to meet this additional demand is comparable to the change in system costs associated with decreasing power sector emissions by approximately 50 % in 2050. This result underscores the importance of adequately incorporating the effects of long-run temperature change in climate policy analysis.

McFarland, James↗

Benchmarking Non-Hardware Balance-of-System (Soft) Costs for U.S. Photovoltaic Systems Using a Bottom-Up Approach and Installer Survey

This report presents results from the first U.S. Department of Energy (DOE) sponsored, bottom-up data-collection and analysis of non-hardware balance-of-system costs—often referred to as “business process” or “soft” costs—for residential and commercial photovoltaic (PV) systems. Annual expenditure and labor-hour-productivity data are analyzed to benchmark 2010 soft costs related to the DOE priority areas of (1) customer acquisition; (2) permitting, inspection, and interconnection; (3) installation labor; and (4) installer labor for arranging third-party financing. Annual expenditure and labor-hour data were collected from 87 PV installers. After eliminating outliers, the survey sample consists of 75 installers, representing approximately 13% of all residential PV installations and 4% of all commercial installations added in 2010. Including assumed permitting fees, in 2010 the average soft costs benchmarked in this analysis total $1.50/W for residential systems (ranging from $0.66/W to $1.66/W between the 20th and 80th percentiles). For commercial systems, the median 2010 benchmarked soft costs (including assumed permitting fees) are $0.99/W for systems smaller than 250 kW (ranging from $0.51/W to $1.45/W between the 20th and 80th percentiles) and $0.25/W for systems larger than 250 kW (ranging from $0.17/W to $0.78/W between the 20th and 80th percentiles). Additional soft costs not benchmarked in the present analysis (e.g., installer profit, overhead, financing, and contracting) are significant and would add to these figures. The survey results provide a benchmark for measuring—and helping to accelerate—progress over the next decade toward achieving the DOE SunShot Initiative’s soft-cost-reduction targets. We conclude that the selected non-hardware business processes add considerable cost to U.S. PV systems, constituting 23% of residential PV system price, 17% of small commercial system price, and 5% of large commercial system price (in 2010). These processes present significant opportunities for further cost reductions and labor-productivity gains.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Discussion Regarding Aqueous Homogeneous Reactor (AHR) Benchmarks

“Characteristics of Fissile Solution Systems”, LA-UR-14-21513, published by the same authors, detailed the behavior of the subject systems that distinguishes them from those employing solid fuels. This Report, a companion to the presentation by the same name published by the authors as LA-UR-14- 21529, extends that discussion to illustrate this behavior with reference to the operation of historic aqueous homogeneous reactors (AHR). In this report the term “benchmark” refers to those systems for which it is judged that sufficient experimental data exists to serve as a reference for the behavior of the class of fissile solution systems called AHR. As has been discussed in the previous report, AHR exhibit a range of modes of operation generally determined by the amount of excess reactivity inserted into the system from a steady-state condition, such as sub-critical startup, and the rate of that insertion. The amount of reactivity inserted may fall in the range of $\$0.00$ < Reactivity ≤ $\$1.00$, in the usual units of “dollars” and “cents” or > $\$1.00$. The initial region is called “delayed critical” while the latter is referenced as “super prompt critical”. Excess reactivity may be inserted in rates ranging from slow ramp to step, which drives system dynamics; however, regardless of either of these factors, amplitude or rate of insertion, the ultimate result will be steady-state operation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmarking Non-Hardware Balance-of-System (Soft) Costs for U.S. Photovoltaic Systems, Using a Bottom-Up Approach and Installer Survey – Second Edition

This report presents results from the second U.S. Department of Energy (DOE) sponsored, bottom-up data-collection and analysis of non-hardware balance-of-system costs -- often referred to as 'business process' or 'soft' costs -- for U.S. residential and commercial photovoltaic (PV) systems. In service to DOE's SunShot Initiative, annual expenditure and labor-hour-productivity data are analyzed to benchmark 2012 soft costs related to (1) customer acquisition and system design (2) permitting, inspection, and interconnection (PII). We also include an in-depth analysis of costs related to financing, overhead, and profit. Soft costs are both a major challenge and a major opportunity for reducing PV system prices and stimulating SunShot-level PV deployment in the United States. The data and analysis in this series of benchmarking reports are a step toward the more detailed understanding of PV soft costs required to track and accelerate these price reductions.

14 SOLAR ENERGY↗

Data and Insights for the KRUSTY Nuclear-Powered Tests

This document, and the associated files, describe all of the data from the KRUSTY warm criticals and the KRUSTY nuclear system test. The warm criticals were a group of tests where fission power heated the core and the feedback response was studied. There were 3 experiments, the 15-cent run (which was a true “free run”), followed by 30-cent and 60-cent runs, where reactivity was added to heat the core to higher temperatures. The nuclear system test (often referred to as the full-run or the final-run), engaged the power conversion system and evaluated system performance. These experiments are described in a pair of NUCLEAR TECHNOLOGY papers, which includes plots of the data that this document-set includes. Note that a lot of information in this document is based on my interpretation and could be wrong, but I’ve included it to potentially save some people a lot of time and headaches by trying to figure out which instrumentation to believe, but beware treating anything I say as fact. I’ve also included several post-irradiation photos, to show some thermocouple locations and indicate possible changes in emissivity and/or geometry (although no changes in geometry were indicated).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantum mechanics in noninertial reference frames: Relativistic accelerations and fictitious forces

One-particle systems in relativistically accelerating reference frames can be associated with a class of unitary representations of the group of arbitrary coordinate transformations, an extension of the Wigner–Bargmann definition of particles as the physical realization of unitary irreducible representations of the Poincaré group. Representations of the group of arbitrary coordinate transformations become necessary to define unitary operators implementing relativistic acceleration transformations in quantum theory because, unlike in the Galilean case, the relativistic acceleration transformations do not themselves form a group. The momentum operators that follow from these representations show how the fictitious forces in noninertial reference frames are generated in quantum theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60 gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.

07 ISOTOPE AND RADIATION SOURCES↗

Adapting algebraic diagrammatic construction schemes for the polarization propagator to problems with multi-reference electronic ground states exploiting the spin-flip ansatz

For the investigation of molecular systems with electronic ground states exhibiting multi-reference character, a spin-flip (SF) version of the algebraic diagrammatic construction (ADC) scheme for the polarization propagator up to third order perturbation theory (SF-ADC(3)) is derived via the intermediate state representation and implemented into our existing ADC computer program adcman. The accuracy of these new SF-ADC(n) approaches is tested on typical situations, in which the ground state acquires multi-reference character, like bond breaking of H{sub 2} and HF, the torsional motion of ethylene, and the excited states of rectangular and square-planar cyclobutadiene. Overall, the results of SF-ADC(n) reveal an accurate description of these systems in comparison with standard multi-reference methods. Thus, the spin-flip versions of ADC are easy-to-use methods for the calculation of “few-reference” systems, which possess a stable single-reference triplet ground state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Failure mode analysis of the FFTF heating and ventilation system 25

This document was prepared as a supplemental study to Chapter 9.4 of the FFTF Final Safety Analysis Report and is included as a Category A reference in FFTF System Design Description 25, Heating and Ventilation System. It contains the single failure mode analysis on all the heating and ventilation systems that are essential to the safety of the plant, and confirms the adequacy of the system design to accommodate single failures without jeopardizing overall plant safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MFANS 2024 - Formally Proving Characteristics of Cyber-Physical Systems

Cyber-physical systems (CPS) are engineered systems that rely on the smooth integration of computational algorithms and physical elements. This integration presents new challenges for verifying that systems will behave as expected. The goal of this presentation is to present current challenges and potential solutions for the formal verification of cyber-physical systems. For cyber systems, formal methods refer to systematically rigorous mathematical techniques employed in the specification, development, analysis, and verification of both software and hardware systems. Recent advancements in computer science have yielded sophisticated tools specifically designed to address challenges associated with formal methods in complex systems. These tools leverage various foundational concepts such as logic, formal languages, program semantics, type systems, type theory, and automata theory. A notable achievement in the application of formal methods is the seL4 microkernel, claimed to be the first general-purpose operating-system kernel to be verified. Its proof implies the absence of bugs and guarantees that the kernel meets specifications. For physical systems, dynamic and control theory has a history of using rigorous analytic techniques to prove functional correctness. Lyapunov, optimal, classical, modern, and robust control theories all provide rigorous mathematical methods both to analyze system performance and to design controller that can be guaranteed to meet certain objectives. Recent computational techniques like level set theory and reachability analysis provide assertions that a system's state will avoid unsafe regions. Even though success has been independently achieved for cyber systems and physical systems, the integration of such systems creates new challenges. In particular, there is an obvious discrepancy between finite-state machines and infinite-state systems, resulting in different approaches for modeling and analyzing these system. While it is possible to simulate hybrid systems, this provides only a demonstration of a performance and not proof. For hybrid systems, current formal methods and system analysis approaches typically require a workarounds to work on hybrid systems like CPS. This paper will outline the state of the art and limits of current practice for formally verifying CPS and will identify possible research directions that require attention.

97 MATHEMATICS AND COMPUTING↗

Upgrade and Operation of the ATLAS Radiation Interlock System (ARIS)

ATLAS (the Argonne Tandem Linac Accelerator Sys-tem) is a superconducting heavy ion accelerator which can accelerate nearly all stable, and some unstable, iso-topes between hydrogen and uranium. Prompt radiation fields from gamma and or neutron are typically below 1 rem/hr at 30 cm, but are permitted up to 300 rem/hr at 30 cm. The original ATLAS Radiation Interlock System (ARIS), hereafter referred to as ARIS 1.0 was installed 30 years ago. While it has been a functional critical safe-ty system, its age has exposed the facility to high risk of temporary shutdown due to failure of obsolete compo-nents. Topics discussed will be architecture, hardware improvements, functional improvements, and operation permitting personnel access to areas with low levels of radiation.

Blomberg, B. R.↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-156: Can Sr-90 Check Sources Replace Co-60 Measurements for Monitoring of Reference Chamber Stability?

Purpose: To determine the ultimate precision of a system for monitoring reference-class ion chamber stability using a commercial Sr-90 check source. Methods: A detailed investigation of a commercial Sr-90 check source (PTW48002) was carried out using a series of Farmer-type ionization chambers. Investigations included: positioning repeatability (angular variation as chamber is rotated in source, variation in ionization current with vertical alignment); chamber settling; short and long term repeatability Results: i) Measurement precision – the ionization current was typically 10 pA, and therefore a high-precision electrometer is required to prevent electrometer noise/resolution/leakage biaising the results. ii) Chamber settling - the chamber response stabilizes after approximately 10 minutes, which is longer than reported for linac beams and is likely due to the low doserate of the source.iii) The measured response depended at the 1 % level on the orientation of the chamber with respect to the source. However, consistent positioning resulted in repeatability at the 0.05 % level. Care was also required to ensure that the chamber was consistently positioned vertically with respect to the source. The sensitivity to vertical position was found to be > 1 % per mm.iv)With a uniform procedure the long-term (> 6 month) repeatability was found to be better than 0.1 % for multiple chamber types and potentially a precision of 0.05 % is achievable. Conclusion: A Sr-90 check source is easy to use and is a viable alternative to Co-60 for monitoring reference chamber stability.

60 APPLIED LIFE SCIENCES↗

Microbial community composition and diversity in Caspian Sea sediments

The Caspian Sea is heavily polluted due to industrial and agricultural effluents as well as extraction of oil and gas reserves. Microbial communities can influence the fate of contaminants and nutrients. However, insight into the microbial ecology of the Caspian Sea significantly lags behind other marine systems. Here we describe microbial biomass, diversity and composition in sediments collected from three sampling stations in the Caspian Sea. Illumina sequencing of 16S rRNA genes revealed the presence of a number of known bacterial and archaeal heterotrophs suggesting that organic carbon is a primary factor shaping microbial communities. Surface sediments collected from bottom waters with low oxygen levels were dominated by Gammaproteobacteria while surface sediments collected from bottom waters under hypoxic conditions were dominated by Deltaproteobacteria , specifically sulfate-reducing bacteria. Thaumarchaeota was dominant across all surface sediments indicating that nitrogen cycling in this system is strongly influenced by ammonia-oxidizing archaea. This study provides a baseline assessment that may serve as a point of reference as this system changes or as the efficacy of new remediation efforts are implemented.

54 ENVIRONMENTAL SCIENCES↗